首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Xia Chu  Daxue Duan  Guoli Shen  Ruqin Yu 《Talanta》2007,71(5):2040-2047
A new amperometric biosensor for glucose was developed based on adsorption of glucose oxidase (GOx) at the gold and platinum nanoparticles-modified carbon nanotube (CNT) electrode. CNTs were covalently immobilized on gold electrode via carbodiimide chemistry by forming amide linkages between carboxylic acid groups on the CNTs and amine residues of cysteamine self-assembled monolayer (SAM). The fabricated GOx/Aunano/Ptnano/CNT electrode was covered with a thin layer of Nafion to avoid the loss of GOx in determination and to improve the anti-interferent ability. The immobilization of CNTs on the gold electrode was characterized by quartz crystal microbalance technique. The morphologies of the CNT/gold and Ptnano/CNT/gold electrodes have been investigated by scanning electron microscopy (SEM), and the electrochemical performance of the gold, CNT/gold, Ptnano/gold and Ptnano/CNT/gold electrodes has also been studied by amperometric method. In addition, effects of electrodeposition time of Pt nanoparticles, pH value, applied potential and electroactive interferents on the amperometric response of the sensor were discussed.

The enzyme electrode exhibited excellent electrocatalytic activity and rapid response for glucose in the absence of a mediator. The linear range was from 0.5 to 17.5 mM with correction coefficient of 0.996. The biosensor had good reproducibility and stability for the determination of glucose.  相似文献   


2.
A novel base-mismatched oligonucleotide assay method based on label-free electrochemical biosensor was developed, in which the L-cysteine (Cys)-dihydroartemisinin (DHA) complex was used as a new electroactive indicator. In DNA sensor, Cys-DHA complex was initially formed on electrode surface by cathodic scanning, and target oligonucleotide was conjugated with Cys-terminated DHA indicator through electrostatic interaction under optimal pH. The subsequent sequence assay was responsive to hybridization recognition, which target oligonucleotide was captured by the surface-anchored DNA/Cys-DHA probe. The electrochemical signals of biosensor before and after hybridization were compared basing the measurements of semi-derivative linear scan voltammetry (SDLSV) and electrochemical impedance spectroscopy (EIS). On the basis of signal amplification of electroactive indicator and specific recognition of DNA probe, five target oligonucleotides with different mismatched bases were assayed, and a detection limit reached 0.3 nM. Furthermore, atomic force microscopy (AFM) was used to visually characterize specific recognition spots of biosensor at nanoscale. This study demonstrated a new electroactive molecule-based, biomolecule-involved electroactive indicator and its application in recognition and detection of complementary and base-mismatched oligonucleotide.  相似文献   

3.
《Analytical letters》2012,45(11):1698-1706
Titanium(IV) oxide nanotube arrays (TiO2) prepared by electrochemical oxidation were used as a sensor for the catalytic reduction of hydrogen peroxide. The effects of pH, applied voltage, interferences, and linear dynamic range were characterized. The electrode showed rapid response and a linear dynamic range from 5.0 micromolar to 12.0 millimolar in phosphate buffer at pH 6.5 at a working voltage of ?0.8 volt. The maximum sensitivity was 474 milliamperes per molar per square centimeter with good reproducibility and reusability. The electrode was also employed for the electrochemical determination of glucose without a mediator by the immobilization of glucose oxidase on the electroactive surface. The resulting biosensor exhibited good activity and rapid response toward glucose and allowed the determination of glucose from 20 micromolar to 1 millimolar and 1–10 millimolar.  相似文献   

4.
《Electroanalysis》2005,17(17):1578-1582
The results presented here demonstrate the important catalytic effect of a carbon paste electrode modified by dispersion of gold nanoparticles towards different electroactive compounds. The oxidation of hydrogen peroxide starts at potentials 400 mV less positive than at bare carbon paste, while the reduction, almost negligible at bare carbon paste, starts at 0.100 V. The influence of the size and amount of gold nanoparticles in the composite matrix on the response of the electrode is discussed. The incorporation of albumin within the carbon paste facilitates the dispersion of gold nanoparticles, improving substantially the catalytic effects. At carbon paste modified with gold nanoparticles and albumin, the peak potential separation for hydroquinone decreases from 0.385 V to 0.209 V while the reduction current increases from 16.6 to 75.2 μA. The immobilization of polyphenol oxidase within the carbon paste electrode modified with nanoparticles has allowed us to obtain a very sensitive biosensor for dopamine even in the presence of large excess of ascorbic acid.  相似文献   

5.
This paper investigates the electrochemical behavior of p-aminophenol (PAP) on commercially available carbon screen-printed electrodes (CSPEs) and gold screen-printed electrodes (GSPEs) at neutral and basic pHs for the development of inexpensive immunoassays. The electrochemical oxidative signal from PAP results from its adsorption to the electrode. The formation of self-assembled monolayers on gold electrodes prevented PAP adsorption but also reduced its oxidative current, confirming that adsorption increases signal production. On bare electrodes, PAP adsorption results in oxidative current variability depending on the electroactive surface area of the screen-printed electrode. This variability could not be remedied by cleaning and reusing the same GSPE. Decreasing the PAP concentration to 3.8 μM greatly improved the consistency of the measurements, suggesting that the adsorption of PAP is concentration-dependent. Multiple PAP oxidations on the same electrode caused polymerization, limiting PAP in continuous monitoring applications. Infrared and Raman spectroscopy allow the distinction between adsorbed PAP and electropolymerized PAP on the surface of a gold wafer. The results from this study suggest that the use of PAP production in immunoassays with SPEs must be fine-tuned, and electrodes must be cleaned or disposed of between measurements.  相似文献   

6.
We have developed an enzymatic glucose biosensor that is based on a flat platinum electrode which was covered with electrophoretically deposited rhodium (Rh) nanoparticles and then sintered to form a large surface area. The biosensor was obtained by depositing glucose oxidase (GOx), Nafion, and gold nanoparticles (AuNPs) on the Rh electrode. The electrical potential and the fractions of Nafion and GOx were optimized. The resulting biosensor has a very high sensitivity (68.1 μA mM?1 cm?2) and good linearity in the range from 0.05 to 15 mM (r?=?0.989). The limit of detection is as low as 0.03 mM (at an SNR of 3). The glucose biosensor also is quite selective and is not interfered by electroactive substances including ascorbic acid, uric acid and acetaminophen. The lifespan is up to 90 days. It was applied to the determination of glucose in blood serum, and the results compare very well with those obtained with a clinical analyzer.
Figure
An enzymatic glucose biosensor was prepared based on rhodium nanoparticle modified Pt electrode and glucose oxidase immobilized in gold nanoparticles and Nafion composite film. The electrode showed a good response to glucose. The sensor was applied to the determination of glucose in blood serum.  相似文献   

7.
An amperometric biosensor for nitrite was prepared by immobilizing cytochrome c (Cyt c) on a gold electrode that was modified with Nafion and a Cu-Mg-Al layered double hydroxide (Cu-LDH). The Cu-LDH was characterized by Fourier transform infrared spectroscopy and powder X-ray diffraction. The UV-visible spectrum suggests that Cyt c retains its native conformation in the modified film. The direct electrochemical investigation indicated that the composite film represents a good platform for the immobilization of Cyt c as well as an excellent promoter for the electron transfer between Cyt c and the gold electrode. Moreover, the biosensor showed a remarkable bioelectrocatalytic activity for the oxidation of nitrite with a linear range from 0.75 to 123 μM. The detection limit is 2?×?10?7 M (S/N?=?3). The biosensor was successfully applied to the determination of nitrite in food samples.  相似文献   

8.
A label-free and sensitive electrochemical biosensing strategy for a hepatocellular carcinoma biomarker of miRNA-122 has been proposed based on hybridization induced ion-barrier effect on the electroactive sensing interface.First,a bifunctional electroactive electrode with the nanocomposite of Prussian blue(PB) and gold nanoparticles(AuNPs) was prepared through a two-step electrodeposition process.The PB endows the electrode excellent K~+-dependent voltammetric signal and the AuNPs act as the matrix for the self-assembly immobilization of the thiolated probe DNA.Upon specific hybridization of probe DNA with the target miRNA-122,the formed double duplex induced the ion-barrier effect,which blocked the diffusion of the K~+ from the bulk solution to the electrode surface.As a result,the voltammetric signal of the PB on the electrode was surpressed,and thus the target miRNA-122 was monitored.The sensing assay showed that the miRNA-122 could be analyzed in the concentration range from 0.1 fmol/L to 1.0 nmol/L,with a detection limit of 0.021 fmol/L.The practical applicability of the biosensor was also verified by the spiking serum assay.  相似文献   

9.
《Analytical letters》2012,45(17):3159-3169
Abstract

The nanocomposites of gold nanoparticles and multi‐walled carbon nanotubes (MWCNTs) have been applied in the enhanced electrochemical detection of DNA hybridization. Gold nanoparticles coated on MWCNTs uniformly were synthesized by simply one step reaction. Target DNA was detected by the peak current difference of differential pulse voltammetry (DPV) signals of the electroactive indicator methylene blue (MB) before and after hybridization on the Au/MWCNTs modified glass carbon electrode (GCE). Due to the excellent electrical conductivity of the novel matrix, the biosensor revealed high sensitivity with the detection level down to 1.0 pM. Excellently selectivity and reproducibility were also discussed.  相似文献   

10.
A sensitive electrochemical biosensor for detecting the sequence of short DNA oligomers is represented. The biosensor is based on a platinum electrode covered a polymerized membrane of conductive monomer N‐[6‐(thien‐3‐yl)acetoxy]‐pyrrolidine‐2, 5‐dione (TAPD). The membrane of TAPD immobilizes a probe DNA on the electrode. The hybridization of the probe with a sequence‐specific DNA in sample solutions is monitored by a self‐synthesized electroactive indicator, which specifically intercalates in the hybrids on the electrode surface. The current signal of the biosensor is proportional to the concentration of the target DNA in samples, and a very low detection limit of 5 × 10?10 mol/L is found. The biosensor has been used to detect the short oligomers containing of HTV‐1 and mycobacterrium nucleotide sequences.  相似文献   

11.
An electrochemical hybridization biosensor based on peptide nucleic acid (PNA) probes is presented. PNA probes were attached covalently through a competition of free amines on the guanine bases and also at the 5 end of the probe, using N-(3-dimethylamino)propyl)-N-ethylcarbodiimide hydrochloride (EDC) and N-hydroxysuccinimide (NHS) onto a carboxylate terminated alkanethiol self-assembled monolayer (SAM) preformed on a gold electrode (AuE). The covalently immobilized probe could selectively hybridize with the target DNA to form a hybrid on the surface despite the bases being attached to the SAM. The changes in the peak currents of methylene blue (3,7-bis(dimethylamino)phenothiazin-5-ium chloride, MB), an electroactive label, were observed upon hybridization of probe with the target. Effective discrimination against point mutation was also obtained. Performance characteristics of the sensor are described, along with future prospects.  相似文献   

12.
以天青Ⅰ为介体的纳米金颗粒增强的葡萄糖传感器   总被引:1,自引:1,他引:1  
采用层层自组装的方法和异种电荷互相吸引的原理,将Nafion修饰在金电极上固载带正电荷的天青Ⅰ,并利用天青Ⅰ中的氨基固载纳米金,再通过纳米金将酶固定在金电极表面,制成了葡萄糖传感器.采用循环伏安法和交流阻抗法,研究了金电极表面组装各层之后的电化学特征,以及电极对葡萄糖的电化学催化作用. 结果表明,天青Ⅰ不仅可以固定酶和纳米金,而且还可以在酶和电极之间有效地传递电子.在优化的实验条件下,该传感器对葡萄糖响应的线性范围为5.1×10-6 ~4.0×10-3 mol/L,检出限(S/N=3)为1.0 μmol/L.该生物传感器显示出较好的稳定性和抗干扰能力,将其用于人体血清中葡萄糖的测定,结果令人满意.  相似文献   

13.
本文构建了一种基于分子信标自由末端现场标记电活性信号分子的新型DNA传感器.首先将3′修饰巯基的分子信标通过Au–S键自组装到金电极表面,然后在修饰有羧基的5′自由末端通过共价偶合和配位作用依次组装上三聚氰胺(Mel)和铜离子(Cu2+),得到以Mel-Cu2+配合物为电活性信号源的分子信标.该方法简单实现了电活性分子信标的标记、分离和纯化.以[Fe(CN)6]3-/4-为电化学探针,采用循环伏安和电化学阻抗法对层层自组装过程进行了表征.杂交实验表明,Mel-Cu2+信号源所对应的峰电流强度随着杂交液浓度的增大逐渐降低,且氧化峰电流与互补序列浓度对数在1.0×10-15~1.0×10-9 mol/L范围内呈良好的线性关系.根据3σ计算得到检测限为2.4×10-16 mol/L.另外,由于分子信标特殊的茎环结构特征和Mel-Cu2+信号源稳定的无机配位组成,传感器显示了很高的特异性、再生性和稳定性.  相似文献   

14.
The electrochemical oxidation of thrombin on the surface of carbon screen printed electrodes was studied. The electrochemical activity of thrombin was predicted, using bioinformation analysis, based on the data about the electrochemical properties of amino acids. The number of potentially electroactive amino acid residues, namely, tyrosine (Tyr), tryptophan (Trp), cysteine (Cys), histidine (His), methionine (Met), and cystine (Cys-Cys) located on the protein surface and orientated by their electroactive groups toward the electrode surface, i.e., accessible for electrochemical oxidation was calculated. The theoretical data were confirmed experimentally by cyclic and square-wave voltammetry. The available data on the protein structure allowed us to attribute the recorded electrochemical signals of thrombin oxidation to certain types of amino acid residue: the oxidation peak with a potential maximum at 0.7–0.8 V (vs. Ag/AgCl) was attributed to the oxidation of the Trp and Tyr residues; the wave in the range 1.0–1.2 V, to the oxidation of His; and the wave at 1.2–1.5 V, to the oxidation of Met and Cys-Cys. The electroanalysis based on the oxidation peak of the Tyr and Trp amino acid residues allowed to detect thrombin up to the concentration of 10–7 M. The suggested strategy for predicting the electrochemical activity can be used for investigating the properties of many other proteins and peptides and serve as a basis for their quantitative determination when developing various sensor and biosensor devices.  相似文献   

15.
An electrochemical DNA biosensor was established for the determination of actin-assembly inducing protein (actA) gene sequences from Listeria monocytogenes and its polymerase chain reaction (PCR) product. The actA gene probe sequences were covalently immobilized on the surface of the mercaptoacetic acid self-assembled gold electrode with the help of N-(3-dimethylaminopropyl)-N′-ethylcarbodiimide hydrochloride (EDC) and N-hydroxysuccinimide (NHS), which was further used to hybridize with the target sequence. Toluidine blue (TB) was used as an effective electrochemical indicator for the discrimination of the hybridization reaction on the electrode surface, which had stronger interaction with double-stranded DNA (dsDNA) than single-stranded DNA (ssDNA). The electrochemical parameters of TB on DNA modified electrodes were carefully calculated. Based on the different electrochemical responses of TB on DNA modified electrodes, the actA gene sequences can be detected in the concentration range from 1.0 × 10-7 to 8.0 × 10-5 M. The PCR product of Listeria monocytogenes was successfully detected by the proposed electrochemical biosensor.  相似文献   

16.
A wealth of research has been available discussing nanogap devices for detecting very small quantities of biomolecules by observing their electrical behavior generally performed in dry conditions. We report that a gold nanogapped electrode with tunable gap length for ultra-sensitive detection of streptavidin based on electrochemical impedance technique. The gold nanogap is fabricated using simple monolayer film deposition and in-situ growth of gold nanoparticles in a traditional interdigitated array (IDA) microelectrode. The electrochemical impedance biosensor with a 25-nm nanogap is found to be ultra-sensitive to the specific binding of streptavidin to biotin. The binding of the streptavidin hinder the electron transfer between two electrodes, resulting in a large increase in electron-transfer resistance (Ret) for operating the impedance. A linear relation between the relative Ret and the logarithmic value of streptavidin concentration is observed in the concentration range from 1 pM (picomolar) to 100 nM (nanomolar). The lowest detectable concentration actually measured reaches 1 pM. We believe that such an electrochemical impedance nanogap biosensor provides a useful approach towards biomolecular detection that could be extended to a number of other systems.  相似文献   

17.
Song MJ  Kim JH  Lee SK  Lim DS 《Analytical sciences》2011,27(10):985-989
An electrochemical biosensor was developed using boron-doped diamond (BDD) as an electrode material. To enhance the electrical performance of the electrode, the BDD electrode was decorated with Pt-nanoparticles (Pt-NPs) by electrochemical deposition. Their morphology according to the applied potentials for the synthesis of Pt-NPs was characterized by SEM. To identify the performance of the electrode modified with Pt-NPs, glucose detection was used as a sample sensing process, and the results were compared with those of a gold electrode and a bare BDD electrode. The electrochemical characteristics of the modified electrode were examined by cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS). The BDD electrode with the Pt-NPs showed higher sensitivity and a lower detection limit than the Au electrode and BDD electrode. The proposed biosensor based on the Pt-NPs decorated BDD electrode showed high sensitivity, a low detection limit, fast direct electron transfer and good stability.  相似文献   

18.
The fabrication of a thermolysin-based biosensor capable of detecting ochratoxin A (OTA) from food samples is described. The electrochemical deposition of calcium cross-linked cellulose film (CCLC) and gold nanoparticles (AuNPs) on graphene (GR) for modification of a glassy carbon electrode (GCE) is the first step. Then the thermolysin (TLN) enzyme in a polyvinyl alcohol (PVA)/polyethylenimine (PEI) matrix is immobilized. The impedimetric biosensor response is linear from 0.2 nM to 100 nM with a detection limit of 0.2 nM. The obtained stable and reproducible biosensor is then applied for the detection of OTA in spiked extracts from coffee beans.  相似文献   

19.
以聚乙烯不干胶掩膜版法结合金属溅射沉积技术在FR-4玻璃纤维版上制作了由6个金膜工作电极(1 mm×2 mm)、1个大面积金膜对电极(2 mm×13 mm)和1个厚膜Ag/AgCl参比电极构成的集成化金膜阵列电极系统,并利用电化学手段对阵列电极系统进行了考察。研究结果表明,K3Fe(CN)6在厚膜Ag/AgCl/1.0 mol/L NaCl参比电极上的式电位与商业Ag/AgCl/3.0 mol/L NaCl参比电极相差0.067 V;参比电极放置1个月后,测量电位未发生明显变化。利用扫描电化学显微镜对工作电极表面平整度进行考察,结果表明工作电极表面具有较好的平整度。通过测量H2SO4还原峰面积评价了工作电极电化学面积的批内、批间一致性;通过K3Fe(CN)6在电极上的Ipa/Ipc比值评价了工作电极电化学特性的批内、批间一致性。结果表明,阵列电极面积和电化学特性具有良好的批内和批间一致性。对集成化金膜阵列电极系统的研究结果表明,聚乙烯不干胶掩膜版法结合金属溅射沉积技术制作的阵列电极能够满足电化学电极的要求,可作为电化学生物传感器的基础电极。  相似文献   

20.
A feasible method to fabricate glucose biosensor was developed by covalent attachment of glucose oxidase (GOx) to a gold nanoparticle monolayer modified Au electrode. Cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS) of ferrocyanide followed and confirmed the assemble process of biosensor, and indicated that the gold nanoparticles in the biosensing interface efficiently improved the electron transfer between analyte and electrode surface. CV performed in the presence of excess glucose and artificial redox mediator, ferrocenemethanol, allowed to quantify the surface concentration of electrically wired enzyme (Gamma(E)(0)) on the basis of kinetic models reported in literature. The Gamma(E)(0) on proposed electrode was high to 4.1 x 10(-12) mol.cm(-2), which was more than four times of that on electrode direct immobilization of enzyme by cystamine without intermediate layer of gold nanoparticles and 2.4 times of a saturated monolayer of GOx on electrode surface. The analytical performance of this biosensor was investigated by amperometry. The sensor provided a linear response to glucose over the concentration range of 2.0 x 10(-5)-5.7 x 10(-3) M with a sensitivity of 8.8 microA.mM(-1).cm(-2) and a detection limit of 8.2 microM. The apparent Michaelis-Menten constant (K(m)(app)) for the sensor was found to be 4.3 mM. In addition, the sensor has good reproducibility, and can remain stable over 30 days.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号