首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
In the present paper, a system for on-line preconcentration and determination of copper by flame atomic absorption spectrometry (FAAS) was developed. It was based on solid phase extraction of copper(II) ions on a minicolumn of Amberlite XAD-2 loaded with 2-(2-thiazolylazo)-5-dimethylaminophenol (TAM). The optimisation process was carried out using Doehlert designs. Four variables (sampling flow rate, SR; elution flow rate, buffer concentration, BC; and pH) were regarded as factors in the optimisation. The parameter “sensitivity efficiency (SE)” proposed in this paper, and defined as the analytical signal obtained for an on-line enrichment system for a preconcentration time of 1 min was used as analytical response in the optimisation process. Using the established experimental conditions, the proposed on-line system allowed determination of copper with detection limit (3σ/S) of 0.23 μg l−1, and a precision (repeatability), calculated as relative standard deviation (R.S.D.) of 3.9 and 3.7% for copper concentration of 5.00 and 20.00 μg l−1, respectively. The preconcentration factor obtained is 62. The recovery achieved for copper determination in presence of several cations demonstrated that this has enough selectivity for analysis of food samples. The robustness of the proposed system was also evaluated. The accuracy was confirmed by analysis of the following certified reference materials (CRMs): Rice flour NIES 10a, Spinach leaves NIST 1570a, Apples leaves NIST 1515 and Orchard leaves NBS 1571. This procedure was applied for copper determination in natural food samples.  相似文献   

2.
用自制的蒸气发生装置,在强还原剂存在下,对铜蒸气的生成进行了详细研究,并通过该装置测定非蒸气发生元素镁和在络合剂掩蔽下测铜两种不同的方法进行了验证。对酸的种类及浓度、NaBH4溶液流速及浓度、反应管道长度的影响等实验参数和干扰情况进行了研究。用该方法测定了面粉中铜的质量分数,检出限为6μg L。  相似文献   

3.
本文讨论了用火焰原子吸收法测定粗锡中的铜含量的方法。试料用盐酸、硝酸、酒石酸溶解。在5%盐酸介质中,使用空气-乙炔火焰,波长选用324.7 nm,用原子吸收光谱法测量铜的吸光度。以工作曲线法计算铜含量。研究了仪器的最佳测量条件,元素测定的质量数以及酸度的影响等实验。方法测定结果准确、可靠,样品加标回收率在97.20%~102.00%。能满足日常检测应用。  相似文献   

4.
浊点萃取-火焰原子吸收光谱法测定水样中痕量铜的研究   总被引:19,自引:0,他引:19  
提出了浊点萃取火焰原子吸收光谱法测定痕量铜的新方法。详细探讨了溶液pH,试剂浓度等实验条件对浊点萃取及测定灵敏度的影响,在最佳下,富集50mL样品溶液,用火焰原子吸收光谱法测定,铜的检测限为0.35μg/L,铜的富集倍率为71倍。方法用于自来水、河水及海水中痕量铜的测定。  相似文献   

5.
Castro MT  Baccan N 《Talanta》2005,65(5):1264-1269
In the present paper, a procedure for preconcentration and determination of copper in soft drink using flame atomic absorption spectrometry (FAAS) is proposed, which is based on solid-phase extraction of copper(II) ions as its ion pair of 1,10-phenanthroline complexes with the anionic surfactant sodium dodecil sulphate (SDS), by Amberlite XAD-2 resin. The optimization process was carried out using 24–1 factorial and 22 factorial with a center point designs. Four variables (XAD-2 mass, copper mass, sample flow rate and elution flow rate) were regarded as factors in the optimization. Student's t-test on the results of the 24–1 factorial design with eight runs for copper extraction, demonstrated that the factors XAD-2 mass and sample flow rate in the levels studied are statistically significant. The 22 factorial with a center point design was applied in order to determine the optimum conditions for extraction. The procedure proposed allowed the determination of copper with detection limits (3/S) of 3.9 μg l−1. The precision, calculated as relative standard deviation (R.S.D.) was 1.8% for 20.0 μg l−1 of copper. The preconcentration factor was 100. The robustness of this procedure is demonstrated by the recovery achieved for determination of copper in the presence of several cations. This procedure was applied to the determination of copper in soft drink samples collected in Campinas, SP, Brazil.  相似文献   

6.
A flow injection wetting-film extraction system without segmentor and phase separator has been coupled to flame atomic absorption spectrometry for the determination of trace copper. Isobutyl methyl ketone (MIBK) was selected as coating solvent and 8-hydroxyquinoline (oxine) as the chelating reagent. By switching of a 8-channel valve and alternative initiation of two peristaltic pumps, MIBK, sample solution containing copper chelate of oxine, and air-segment sandwiched eluting solution (1.0 mol l−1 nitric acid) were sequentially aspirated into an extraction coil made of PTFE tubing of 360 cm length and 0.5 mm i.d. The formation of organic film in the wall of the extraction coil, extraction of the copper chelate into the organic film and back-extraction of the analyte into the eluting solution occurred consecutively when these zones aspirated into the extraction coil were propelled down the extraction coil by a carrier solution at a flow rate of 2 ml min−1. After leaving the extraction coil, the concentrated zone was transported to the nebulizer at its free uptake rate for atomization. Under the optimized conditions, an enrichment factor of 43 and a detection limit of 0.2 μg l−1 copper were achieved at a sample throughput rate of 30 h−1. Eleven determinations of a standard copper solution of 60 μg l−1 gave a relative standard deviation of 1.5%. Foreign ions possibly present in tap water and natural water did not interfere with the copper determination. The developed method has been successfully used to the determination of copper content of tap water and river water.  相似文献   

7.
In this study, flow injection-cloud point extraction (FI-CPE) of iron and copper in food samples by flame atomic absorption spectrometric determination was described. Triton X-114 non-ionic surfactant and Eriochrome Cyanine R (ECR) have been used as an extraction medium and a chelating agent, respectively. The amounts of Triton X-114, ECR and the pH value necessary for extraction were carefully optimized. In addition, several parameters of the FI-CPE system, including sample loading rate, column dimension, type of packing material, eluent flow rate were investigated and analytical characteristics of the method were evaluated. Under optimum conditions, detection limits of 0.33 ng/mL and 0.57 ng/mL and quantification limits of 1.1 ng/mL and 1.9 ng/mL for iron and copper along with enrichment factors of 141 and 99 were obtained, respectively. The calibration was linear over the range 1.5-25 ng/mL and 1.0-35 ng/mL for iron and copper, respectively. The proposed CPE technique has been successfully applied for the determination of iron and copper ions in certified reference materials (NCS DC 73349—bush, branches and leaves; and TM-23.2—fortified water), water samples (mineral and sea water) and food samples (vegetables, bread and hazelnut) with high efficiency.  相似文献   

8.
A flow analysis method with on-line sample digestion/minicolumn preconcentration/flame atomic absorption spectrometry is described for the determination of trace metals in urine. First, urine sample was on-line ultrasound-assisted digested exploiting the stopped-flow mode, and then the metals were preconcentrated passing the pre-treated sample through a minicolumn containing a chelating resin. A home-made minicolumn of commercially available imminodiacetic functional group resin, Chelite Che was used to preconcentrate trace metals (Cu, Fe, Mn and Ni) from urine. The proposed procedure allowed the determination of the metals with detection limits of 0.5, 1.1, 0.8 and 0.8 μg L−1, for Cu, Fe, Mn and Ni, respectively. The precision based on replicate analysis was less than ±10.0%, and the enrichment factor obtained was between 21.3 (Mn) and 44.1 (Ni), for sample volumes between 2.5 and 5.0 mL, and an eluent volume of 110 μL. This procedure was applied for determination of metals in urine of workers exposed to welding fumes and urine of unexposed persons (urine control).  相似文献   

9.
A sensitive and selective method was developed for the determination of traces of manganese in urine using on-line electrochemical preconcentration followed by flame atomic absorption spectrometry detection. A home made flow-through polypropylene cell (4.5 cm long × 0.8 cm diameter filled with glass marbles) with an effective inner volume of 0.5 ml containing a working and a counter electrode, both of glassy carbon and a Pt pseudo reference electrode was located in a flow injection manifold specially designed for the purpose of this work. The manganese was deposited from buffer solution of NH3/NH4Cl at pH 9.00 through an oxidizing process at a current of 400 mA during 7 min. A flow of HCl 0.1 mol l−1 at 4 ml min−1 through the cell, chemically dissolved the deposit. A small portion (15 μl) of the concentrate was introduced in a continuously flowing system by means of a timing device and was then carried to the detector for the manganese quantification. All electrochemical and spectroscopic variables as well as possible interferences in both systems were systematically studied. The relative standard deviations for ten consecutive measurements of manganese solutions of 2.0 and 20 μg l−1 were of 2.3 and 1.5%, respectively, while for a sample processed five times was less then 5%. The accuracy of the developed procedure was evaluated by adding known amounts of manganese standard to urine samples and following the whole procedure. Recoveries within the range 97.2-102.8% were obtained. To further prove the accuracy, a Seronorm Trace Elements in Urine, Batch 403125 sample with a reported concentration of 13 μg Mn l−1 was also analyzed. The experimental value obtained was of 12.7 ± 0.1 μg l−1, which does not differ significantly from the reported amount (p < 0.05). A preconcentration factor of 40, a linear range between 0.015 and 60 μg l−1 and a limit of detection of 15 ng l−1 permitted the determination of manganese in real urine samples from non-exposed subjects in the range 0.5-2.8 μg l−1.  相似文献   

10.
Manganese is extracted on-line from solid seafood samples by a simple continuous ultrasound-assisted extraction system (CUES). This system is connected to an on-line manifold, which permits the flow-injection flame atomic absorption spectrometric determination of manganese. Optimisation of the continuous leaching procedure is performed by an experimental design. The proposed method allows the determination of manganese with a relative standard deviation of 0.9% for a sample containing 23.4 μg g−1 manganese (dry mass). The detection limit is 0.4 μg g−1 (dry mass) for 30 mg of sample and the sample throughput is ca. 60 samples per hour. Accurate results are obtained by measuring TORT-1 certified reference material. The procedure is finally applied to mussel, tuna, sardine and clams samples.  相似文献   

11.
A calibration method has been developed which is realised in the flow injection analysis (FIA) by the gradient technique. According to this method two transient peaks, one for a sample and the other for a sample with standard addition, are recorded and compared point by point in the entire defined time range. The analytical result is estimated on the basis of information gained about the local analyte concentrations in the sample zone. The method allows the results to be reliable when both the non-linear calibration dependence and the interference effect occur. As an example, calcium in synthetic samples containing silicon, phosphate, aluminium, vanadium and titanium, and also in iron ore sample, were determined by flame atomic absorption spectrometry (FAAS). It has been proved, that the method can be effective in overcoming even extremely strong interferences, providing analytical results with average accuracy equal to ca. 5% and with precision 2–3 times inferior to that obtained by conventional FI calibration.  相似文献   

12.
Yu HM  Song H  Chen ML 《Talanta》2011,85(1):625-630
A novel adsorbent-silica gel bound dithizone (H2Dz-SG) was prepared and used as solid-phase extraction of copper from complex matrix. The H2Dz-SG is investigated by means of FT-IR spectra and the SEM images, demonstrating the bonding of dithizone. The H2Dz-SG quantitatively adsorb copper ions, and the retained copper is afterwards collected by elution of 10% (v/v) nitric acid. An on-line flow injection solid-phase extraction procedure was developed for trace copper separation and preconcentration with detection by flame atomic spectrometry. By loading 5.4 mL of sample solution, a liner range of 0.5-120 μg L−1, an enrichment factor of 42.6, a detection limit of 0.2 μg L−1 and a precision of 1.7% RSD at the 40 μg L−1 level (n = 11) were obtained, along with a sampling frequency of 47 h−1. The dynamic sorption capacity of H2Dz-SG to Cu2+ was 0.76 mg g−1. The accuracy of the proposed procedure was evaluated by determination of copper in reference water sample. The potential applications of the procedure for extraction of trace copper were successfully accomplished in water samples (tap, rain, snow, sea and river). The spiking recoveries within 91-107% are achieved.  相似文献   

13.
Derya Kara 《Talanta》2009,79(2):429-545
Micelle-mediated extraction/preconcentration is incorporated on-line into a flow injection system used to determine low levels of Cd(II), Co(II), Cu(II), Mn(II), Ni(II), Pb(II) and Zn(II) present in various samples. The analyte is complexed with HBDAP (N,N′-bis(2-hydroxy-5-bromo-benzyl)1,2-diaminopropane). Under optimal conditions, a solution of 30% (m/v) NaCl and a sample solution containing 2.5 mL of 1% (m/v) sodium dodecyl sulfate (SDS), 0.5 mL of 1.8 × 10−3 M HBDAP and 2.5 mL of pH 8.5 borate buffer solution in 25 mL were pumped through the cotton filled mini-column; onto which the surfactant-rich phase containing the complex is collected. A solution of 0.5 M HNO3 in 50% acetone is used as the eluent. The limits of detection are (ng mL−1) Cd = 0.39, Cu = 3.2, Co = 7.5, Mn = 3.0, Ni = 3.4, Pb = 17.9 and Zn = 0.89 if the sample is allowed to flow for 30 s, but improved for extended preconcentration periods. Analysis of liquid and solid reference materials showed good agreement with the certified values. Complex formation constants between HBDAP and these metal ions were also determined potentiometrically.  相似文献   

14.
Determination of cadmium in urine by ETAAS suffers from severe interferences deteriorating the precision and accuracy of the analysis. Electrodeposition step prior to ETAAS allows to avoid interferences and makes cadmium determination possible even at ultratrace levels. The proposed procedures involve electrolytic deposition of cadmium from acidified urine on previously electrolytically deposited palladium film on a graphite atomizer tube, followed by removal of residual solution, pyrolysis and atomization. Both electrodeposition processes take place in a drop of the respective solution (palladium nitrate modifier and acidified urine, respectively), when Pt/Ir dosing capillary serves as an anode and the graphite tube represents a cathode. The voltage is held at −3.0 V. Matrix removal is then accomplished by withdrawal of the depleted sample solution from the tube (procedure A) or the same but followed by rinsing of the deposit with 0.2 mol l−1 HNO3 (procedure B). The accuracy of both procedures was verified by recovery test. Detection limits 0.025 and 0.030 μg Cd/l of urine were achieved for A and B procedures, respectively. Both procedures are time consuming. The measurement cycle represents 5 and 7 min for A and B procedures, respectively.  相似文献   

15.
Kaya M  Volkan M 《Talanta》2011,84(1):122-126
A new chloride generation system was designed for the direct, sensitive, rapid and accurate determination of the total germanium in complex matrices. It was aimed to improve the detection limit of chloride generation technique by increasing the vapor pressure of germanium tetrachloride (GeCl4). In order to do so, a novel joint vapor production and gas-liquid separation unit equipped with a home-made oven was incorporated to an ordinary nitrous oxide-acetylene flame atomic absorption spectrometer. Several variables such as reaction time, temperature and acid concentration have been investigated. The linear range for germanium determination was 0.1-10 ng mL−1 for 1 mL sampling volume with a detection limit (3 s) of 0.01 ng mL−1. The relative standard deviation (RSD) was 2.4% for nine replicates of a 1 ng mL−1 germanium solution. The method was validated by the analysis of one non-certified and two certified geochemical reference materials, respectively, CRM GSJ-JR-2 (Rhyolite), and GSJ-JR-1 (Rhyolite), and GBW 07107 (Chinese Rock). Selectivity of the method was investigated for Cd2+, Co2+, Cu2+, Fe3+, Ga3+, Hg2+, Ni2+, Pb2+, Sn2+, and Zn2+ ions and ionic species of As(III), Sb(III), Te(IV), and Se(IV).  相似文献   

16.
The present work proposes a direct method based on slurry sampling for the determination of zinc and copper in human hair samples by multi-element sequential flame atomic absorption spectrometry. The slurries were prepared by cryogenic grinding and sonication of the samples. The optimization step was performed using univariate methodology and the factors studied were: nature and concentration of the acid solution, amount sample/slurry volume, sonication time, and particle size. The established experimental conditions are the use of a sample mass of 50 mg, 2 mol L− 1 nitric acid solution, sonication time of 20 min and slurry volume of 10 mL. Adopting the optimized conditions, this method allows the determination of zinc and copper with detection limits of 88.3 and 53.3 ng g− 1, respectively, and precision expressed as relative standard deviation (RSD) of 1.7% and 1.6% (both, n = 10) for contents of zinc and copper of 100.0 and 33.3 μg g− 1, respectively. The accuracy was checked and confirmed by analysis of two certified reference materials of human hair. The procedure was applied for the determination of zinc and copper in two human hair samples. The zinc and copper contents varied from 100.0 to 175.6 and from 3.2 to 32.8 μg g− 1, respectively. These samples were also analyzed after complete digestion in a closed system and determination by FAAS. The statistical comparison by t-test (95% confidence level) showed no significant difference between these results.  相似文献   

17.
G. Doner  A. Ege 《Analytica chimica acta》2004,520(1-2):217-222
An evaluation is made of different digestion methods for the determination of iron and zinc in biscuits prior to flame atomic absorption analysis. For the initial studies, microwave digestion was enough (using hydrogen chloride and nitric acid 3:1, v/v, at 180 °C and 600 W) to provide comparable accuracy, precision, digestion time and non-critical handling of reagents to dry-ashing and wet digestion (using different acid mixtures) and also to a simple acid treatment at room temperature. Although, after a simple microwave digestion, the spiked recoveries were found around 96–102%, to reduce the digestion time and for simplicity we worked on wet acid treatments. The results showed that acid-only treatment is not enough to digest the samples without adding ethanol, which was found necessary to digest organic residue at room temperature. The method was validated by comparison of the data found for commercial biscuit samples through using the proposed procedure and the AOAC official reference spectrophotometric method. Fe concentration in the different biscuits (such as petit beurre, baby biscuits, etc.) ranged from 1.21 to 15.96 mg/100 g while Zn concentration ranged from 0.58 to 2.50 mg/100 g depending on biscuit type. The highest concentration of Fe was in baby biscuits and these biscuits were about thirteen times richer in Fe than petit beurre biscuits.  相似文献   

18.
Using octadecyl functional groups (C18) bonded to silica gel as sorbent and methanol as eluent, the flow injection sorbent extraction features of dialkyldithiophosphates (RO)2P(S)S as the chelating agent for cadmium, copper and lead was investigated in respect of the effects of pH, alkyl substituent group, reagent concentration and masking agent, with flame atomic absorption spectrometric detection. The elements are quantitatively extracted with the short-alkyl-chain reagents (R up to propyl) in acidic medium. The extractability decreases with the number of carbon atoms in the alkyl groups of the reagents and with the reagent concentration when the alkyl groups are larger than butyl, but masking agents increase the extractability. An explanation proposed for this effect is the formation of polynuclear chelates. Diethyldithiophosphate can be used for the selective determination of cadmium, copper and lead in digested solid environmental samples. With 20 s sample loading at 8.7 ml min−1, the enhancement factors are 35 for cadmium and copper or 26 for lead; the detection limits (3σ) are 0.8, 1.4 and 10.0 μg 1−1 for cadmium, copper and lead, respectively.  相似文献   

19.
铜原尾矿中硅含量较高,针对这一特性,本文提出了试样采用饱和氟化氢铵、盐酸、硝酸溶解,在5%的硝酸介质中,于原子吸收光谱仪上,使用空气—乙炔火焰进行铅的测定,建立了铜原尾矿中铅的测定方法。研究结果表明铅的质量浓度在0.05~3μg/mL范围内与吸光度A有良好的线性关系,方法的相对标准偏差0.92%到2.39%,加标回收率96.0%到106.0%,方法以三倍的空白溶液11次测定值的标准偏差作为检出限,检出限0.08μg/mL。  相似文献   

20.
A direct solid sampling flame atomic absorption spectrometric procedure for trace determination of cadmium in biological samples has been developed. Test samples (0.05–2.00 mg) were ground and weighed into small polyethylene vials, which were connected to the device for solid sample introduction into a conventional air/acetylene flame. Test samples were carried as a dry aerosol to a quartz cell, placed between the burner and the optical path, which had a perpendicular entrance and a slit in the upper part. The atomic vapor generated in the flame produced a transient signal that was totally integrated within 1 s. The effect of operating conditions and the extent of grinding on the analytical signal were evaluated. Background signals were always low and a characteristic mass of 0.29 ng Cd was obtained. Calibration was performed using different masses of solid certified reference materials. Results obtained for certified and in-house reference materials were typically within the 95% confidence interval of the certified and/or reference value, and the precision, expressed as relative standard deviation, was between 3.8 and 6.7%. The proposed system is simple and it might be adapted to conventional atomic absorption spectrometers allowing the determination of Cd in more than 80 test samples per hour, excluding weighing.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号