共查询到20条相似文献,搜索用时 0 毫秒
1.
Mandrioli R Mercolini L Ferranti A Furlanetto S Boncompagni G Raggi MA 《Analytica chimica acta》2007,591(2):141-147
A high-performance liquid chromatographic method has been developed for the determination in human plasma of the specific serotonin reuptake inhibitor (SSRI) antidepressant paroxetine and its three main metabolites (M1, M2, M3). Fluorescence detection was used, exciting at λ = 294 nm and monitoring emission at λ = 330 nm for paroxetine (λexc = 280 nm, λem = 330 nm for M1 and M2; λexc = 268 nm, λem = 290 nm for M3). Separation was obtained on a reversed-phase C18 column using a mobile phase composed of 66.7% aqueous phosphate at pH 2.5 and 33.3% acetonitrile. Imipramine (λexc = 252 nm, λem = 390 nm) was used as the internal standard. A careful pre-treatment of plasma samples was developed, using solid-phase extraction with C8 cartridges (50 mg, 1 mL). The calibration curves were linear over a working range of 2.5-100 ng mL−1 for paroxetine and of 5-100 ng mL−1 for all metabolites. The limit of detection (LOD) was 1.2 ng mL−1 for PRX and 2.0 ng mL−1 for the metabolites. The method was applied with success to plasma samples from depressed patients undergoing treatment with paroxetine. Hence, the method seems to be suitable for the therapeutic drug monitoring of paroxetine and its main metabolites in depressed patients’ plasma. 相似文献
2.
Summary A new sensitive HPLC-FLD method has been developed and validated for the determination of cisapride in human plasma for a
bioequivalence study. A gradient method was used to remove late-eluting plasma components of no interest. The separation was
performed on a Li-ChroCART 250-4 Purospher RP-18 (5 μm particle) analytical column fitted with a LiChroCART 4-4 Purospher
RP-18 endcapped (5 μm particle) guard column. The excitation and emission wavelengths were 295 and 350 nm during fluorescence
detection. The calibration plot was linear in the range of 5–200 ng mL−1. A demethoxy analogue of cisapride was used as internal standard. 相似文献
3.
Summary A reliable and sensitive high-performance liquid chromatographic method for the determination of the recent antidepressant
citalopram and two metabolites in human plasma has been developed. Fluorescence detection at 300 nm was used, exciting at
238 nm. Separation was obtained using a reversed-phase column (C18, 250 × 3.0 mm i.d., 5 μm) and a mobile phase. 40% acetonitrile:
60% aqueous tetramethylammonium perchlorate (pH 1.9). Calibration curves were linear over a working range: 5–300 ng mL−1 for citalopram, 2.5–150.0 ng mL−1 for desmethylcitalopram and 2.5–50.0 ng mL−1 for didesmethylcitalopram. The limits of quantitation (LOQ) were 1.5 ng mL−1 for citalopram and desmethylcitalopram and 2.0 ng mL−1 for didesmethylcitalopram. Precision data, as well as accuracy, were satisfactory and no interference from different psychotropic
drugs was found. The method was therefore suitable for therapeutic drug monitoring of citalopram and its active metabolites
in plasma of depressed patients. 相似文献
4.
Summary A sensitive and selective high-performance liquid chromatographic method has been developed for monitoring clozapine levels
in human plasma. Chromatography was performed on a reversed-phase column (C8, 150 mm×4.6 mm i.d., 5 μm) with acetonitrile-aqueous sodium acetate solution, 88∶12 (v/v), as mobile phase; the flow rate was 1 mL min−1. Clozapine oxidation at +800 mV was detected amperometrically. Response was linearly dependent on concentration over the
range 50–1500 ng mL−1 clozapine in plasma. Sample preparation by solid-phase extraction before HPLC analysis gave high extraction yield (94%).
The accuracy and precision of the method were both very good (recovery: 97%;RSD<3.3%). 相似文献
5.
固相萃取-高效液相色谱电化学法检测大鼠血浆儿茶酚胺 总被引:2,自引:3,他引:2
建立了一种Oasis HLB固相萃取-高效液相色谱(HPLC)电化学检测大鼠血浆儿茶酚胺(CAs)的方法。血浆样本在形成二苯基硼酸-儿荼酚胺复合物后经优化的固相提取技术,得到较高样本回收率。以Atlantis C18色谱柱为固定相,确定了各种影响色谱的参数,如流动相组成、pH范围及检测器的设定。儿茶酚胺所有组分肾上腺素(E)、去甲肾上腺素(NE)和多巴胺(DA)的平均提取回收率在90%~95%之间。E、NE和DA的质量浓度在0.25~30ng/mL时与峰面积呈良好的线性关系(r值分别为0.9989,0.9992和0.9984);检出限为0.4pg。该法灵敏、准确、重现性好、结果可靠。 相似文献
6.
固相萃取-高效液相色谱法测定鱼/虾生物体中甲苯咪唑及代谢物的残留 总被引:1,自引:0,他引:1
建立了同时测定鱼、虾生物体中甲苯咪唑及代谢物-氨基甲苯咪唑和羟基甲苯咪唑残留的分析方法。样品以水和乙酸乙酯提取,正己烷去脂、MCX固相萃取柱净化,高效液相色谱-紫外检测器测定。重点研究了样品前处理方法,并对各种不同的固相萃取柱的净化效果和准确度进行了研究。甲苯咪唑及代谢物在5~200μg/kg的添加水平下回收率为81.4%~95.3%,相对标准偏差为1.9%~8.6%,方法线性范围为10~2000ng/mL。方法检测限为甲苯咪唑:5μg/kg,羟基甲苯咪唑:5μg/kg,氨基甲苯咪唑:10μg/kg。 相似文献
7.
Sensitive determination of cinnarizine in human plasma by high performance liquid chromatography and fluorescence detection 总被引:2,自引:0,他引:2
Summary A sensitive high performance liquid chromatographic method has been developed for the determination of cinnarizine in human plasma. Cinnarizine and clocinizine (internal standard) were extracted from acidified plasma (pH 4.7) into carbon tetrachloride and the organic layer was evaporated. The products were separated on a Microspher C18 (3 m) column, using a mixture of 0.04 % triethylamine in 0.01 M ammonium dihydrogen phosphate (NH4H2PO4), pH adjusted to 4.2 with orthophosphoric acid (H3PO4), and acetonitrile (2080, v/v) as mobile phase, at a flow rate of 1 ml/min at 40°C. Fluorescence detection (ex = 245 nm, em = 310 nm) was used; the detection limit was 0.5 ng/ml under the conditions used, and the calibration curve linear in the concentration range evaluated (1–60 ng/ml). The assay has been used to measure cinnarizine concentrations in plasma after oral administration to volunteers. 相似文献
8.
建立了一种柱前衍生高效液相色谱-荧光检测法用于测定血浆中同型半胱氨酸(Hcy)。使用三(2-羧乙基)膦盐酸盐(TCEP)为还原剂,N-(1-芘)马来酰亚胺(NPM)为衍生剂进行样品预处理,Agilent Hypersil C-18柱(250 mm×4.0 mm, 5 μm)进行分离,流动相为15 mmol/L醋酸钠-乙腈-混合酸(300 mL水中含1 mL醋酸和1 mL磷酸)混合溶液,采用梯度洗脱,荧光检测激发波长为330 nm,发射波长为380 nm。Hcy的回收率为(102.08±4.94)%。线性范围为0.500~100 μmol/L,检出限(以信噪比为3计)为0.016 μmol/L。日内与日间相对标准偏差均小于5%。利用该方法对7例高血压患者和7例健康志愿者的血浆进行了测定,结果表明两组间的Hcy含量存在显著的差异(p<0.05)。本方法简单、快速、灵敏、特异,适用于血浆Hcy的临床定量测定。 相似文献
9.
Determination of phenazopyridine in human plasma by high performance liquid chromatography 总被引:1,自引:0,他引:1
Summary A simple, low-cost, sensitive and selective HPLC method was developed for the determination of phenazopyridine in human plasma.
The method employs UV detection of phenazopyridine and of the internal Standard at 2 different wavelengths. Calibration curves
were linear over a large dynamic range, i.e., within 0.05–10.0 μg mL−1 with limit of quantification of 0.05 μg mL−1, and a limit of detection of 0.01 μg mL−1. 相似文献
10.
Summary A high performance liquid chromatographic method for the determination of flecainide in serum has been developed. The analysis is performed on a microparticulate silica column. The eluate is monitored by fluorescence detection at an excitation wavelength of 300nm and an emission wavelength of 370nm. No sources of interference were identified and a coefficient of variation of less than 8% was observed on repeated flecainide determinations. The method has a good reproducibility, specificity and accuracy, and can be applied in therapeutic drug monitoring of flecainide in patients. 相似文献
11.
B. Dalmadi Kiss K. Balogh Nemes I. Ürmös J. Szúnyog I. Klebovich 《Chromatographia》2000,51(1):S217-S220
Summary A new sensitive HPLC-UV method has been developed and validated for the determination of amboroxol in dog plasma enabling
the investigation of a newly developed 75 mg ambroxol-containing retard capsule of EGIS Pharmaceuticals Ltd., Budapest, Hungary.
A gradient method was used for removing the longer retained plasma components of no interest. The separation was performed
on a BDS Hypersil C18 (5 μm, 250×2.1 mm) analytical column, supplied with a 10 mm guard column containing the same packing
material. The detection was performed at 210 nm. The calibration curve was linear in the range 25–2000 ng·mL−1. Nerisopam (EGIS-6775) was used as internal standard.
Presented at Balaton Symposium on High Performance Separation Methods, Siófok, Hungary, September 1–3, 1999 相似文献
12.
Hui-Juan Jia 《Analytica chimica acta》2006,562(2):171-175
In the present work, an analytical method for determination of risedronate, a member of bisphosphonates, is described for the routine analysis in rat plasma. Sample pre-treatment involves protein precipitation, co-precipitation with calcium at alkaline pH, hydrolysis of possible derivatives of pyrophosphate and reprecipitation. A good separation was obtained by using a reversed-phase column (Hypersil ODS-2 C18, 4.6 mm × 250 mm, 5 μm). The mobile phase was an aqueous solution of buffer (contained 1.5 mM EDTA-2Na, 1 mM sodium etidronate, 11 mM sodium phosphate and 5 mM tetrabutylammonium bromide as ion-pair reagent) - methanol (88:12, v/v) adjusted to pH 6.75 using 1 M NaOH. The flow rate was 1 ml min−1. UV detection (λ = 262 nm) was used to quantitate risedronate in the concentration range of 10-500 ng ml−1. The limit of detection and quantitation for risedronate were 7 and 10 ng ml−1, respectively. The method was applied successfully to plasma samples from Wistar rats undergoing oral administration of risedronate mini-pills. Precision, extraction recoveries, as well as accuracy results, were satisfactory and no interference was found at the retention time of risedronate. Hence, the method is suitable for monitoring risedronate in rat plasma. 相似文献
13.
A novel, highly sensitive, simple, and rapid strategy was designed and developed for simultaneous determination of cabozantinib (CBZ) as an anticancer agent and its main metabolites including monohydroxy sulfate (EXEL-1646), N-oxide (EXEL-5162(, amide cleavage product (EXEL-5366), and 6-desmethyl amide cleavage product sulfate) EXEL-1644). Measurements were done through a micellar liquid chromatography (MLC) method coupled with fluorescence detection. The high-performance liquid chromatography (HPLC) was performed using a Kinetex C18 100 Å column as well as acetonitrile, cetyltrimethylammonium bromide (CTAB; 0.2 mol.L?1), and tris buffer (pH 8.5) solutions as the mobile phase at a 40:50:10 (v/v) ratio. The method’s linearity (20 to 700 ng.mL?1), limit of detection (LOD; 2.11 to 3.69 ng.mL?1), limit of quantification (LOQ; 20 to 30 ng.mL?1), intra- and inter-day precisions (RSD < 4.00%), selectivity, recovery, and robustness were fully evaluated. According to the obtained results, the developed method can be used for simple and rapid (~35 min) quantification of CBZ as an anticancer drug and its major metabolites in human serum samples with high sensitivity and low cost. 相似文献
14.
Malli D Gikas E Vavagiannis A Kazanis M Daniilides K Gennimata D Panderi I 《Analytica chimica acta》2007,599(1):143-150
A sensitive and selective high-performance liquid chromatographic method has been developed and validated for the determination of nateglinide in human plasma. Nateglinide and the internal standard, undecylenic acid, were extracted from plasma by liquid-liquid extraction using a mixture of ethyl acetate-diethyl ether, 50:50 (v/v). Pre-column derivatization reaction was performed using a coumarin-type fluorescent reagent, N-(7-methoxy-4-methyl-2-oxo-2H-6-chromenyl)-2-bromoacetamide. The derivatization proceeded in acetone in the presence of potassium carbonate and catalyzed by 18-crown-6 ether. The fluorescent derivatives were separated under isocratic conditions on a Hypersil BDS-C8 analytical column (250.0 mm × 2.1 mm i.d., particle size 5 μm) with a mobile phase that consisted of 65% acetonitrile in water and pumped at a flow rate of 0.50 mL min−1. The excitation and emission wavelengths were set at 345 and 435 nm, respectively. The assay was linear over a concentration range of 0.05-16.00 μg mL−1 for nateglinide with a limit of quantitation of 0.05 μg mL−1. Quality control samples (0.05, 4.50 and 16.00 μg mL−1) in five replicates from five different runs of analysis demonstrated intra-assay precision (%coefficient of variation <6.8%), inter-assay precision (%coefficient of variation <1.6%) and an overall accuracy (%relative error) less than −3.4%. The method can be used to quantify nateglinide in human plasma covering a variety of pharmacokinetic or bioequivalence studies. 相似文献
15.
A fast and sensitive high-performance liquid chromatographic method has been developed for the determination in human plasma of MHPG (3-methoxy-4-hydroxyphenylethylenglycol) and VMA (vanillyl mandelic acid), the main metabolites of epinephrine and norepinephrine. Analyses were carried out at 325 nm while exciting at 285 nm on a reversed-phase column (Atlantis C18, 150 mm × 4.6 mm I.D., 5 μm) using a mobile phase composed of 2% methanol and 98% aqueous citrate buffer at pH 3.0. A careful solid-phase extraction procedure, based on mixed-mode reversed-phase - strong anion exchange Oasis cartridges (MAX, 30 mg, 1 mL), was developed for the pre-treatment of plasma samples. Extraction yields were satisfactory, always higher than 90%. Calibration curves were linear over the 0.2-40.0 ng mL−1 concentration range for MHPG and over the 0.5-40.0 ng mL−1 concentration range for VMA. The method was successfully applied to plasma samples of former drug users undergoing detoxification therapy and subjects “at risk” of developing drug addiction. 相似文献
16.
Wang Y Zhang W Dong Y Fan R Sheng G Fu J 《Analytical and bioanalytical chemistry》2005,383(5):804-809
A high-performance liquid chromatographic method with fluorescence detection has been developed to determine the urinary polycyclic
aromatic hydrocarbon metabolites 2-hydroxynaphthalene, 2-hydroxyfluorene, 9-hydroxyphenanthrene, 1-hydroxypyrene and 3-hydroxybenz[a]pyrene.
Solid phase extraction (SPE) was used to clean up the samples, and washing with 30% methanol was found to be the best way
to remove interferences in the matrix. The method detection limits ranged from 0.044 μg/L for 1-hydroxypyrene to 1.615 μg/L
for 3-hydroxybenz[a]pyrene, and the recoveries ranged between 40% for 3-hydroxybenz[a]pyrene and 99% for 2-hydroxynaphthalene.
The within-day relative standard deviation was lowest for 2-hydroxynaphthalene at 0.67% and went up to 2.42% for 3-hydroxybenz[a]pyrene,
and the between-day relative standard deviation ranged from 3.84% for 9-hydroxyphenanthrene to 10.42% for 2-hydroxyfluorene.
The correlation coefficients were between 0.9962 and 0.9998. The developed method was successfully used to analyze samples
from student volunteers in a high school. 相似文献
17.
A three-phase liquid-phase microextraction (LPME) method using porous polypropylene hollow fibre membrane with a sealed end was developed for the extraction of mirtazapine (MRT) and its two major metabolites, 8-hydroxymirtazapine (8-OHM) and demethylmirtazapine (DMR), from human plasma. The analytes were extracted from 1.0 mL of plasma, previously diluted and alkalinized with 3.0 mL 0.5 mol L−1 pH 8 phosphate buffer solution and supplemented with 15% sodium chloride (NaCl), using n-hexyl ether as organic solvent and 0.01 moL L−1 acetic acid solution as the acceptor phase. Haloperidol was used as internal standard. The chromatographic analyses were carried out on a chiral column, using acetonitrile-methanol-ethanol (98:1:1, v/v/v) plus 0.2% diethylamine as mobile phase, at a flow rate of 1.0 mL min−1. Multi-reaction monitoring (MRM) detection was performed by mass spectrometry (MS-MS) using a triple-stage quadrupole and electrospray ionization interface operating in the positive ion mode. The mean recoveries were in 18.3-45.5% range with linear responses over the 1.25-125 ng mL−1 concentration range for all enantiomers evaluated. The quantification limit (LOQ) was 1.25 ng mL−1. Within-day and between-day assay precision and accuracy (2.5, 50 and 100 ng mL−1) showed relative standard deviation and the relative error lower than 11.9% for all enantiomers evaluated. Finally, the method was successfully used for the determination of mirtazapine and its metabolite enantiomers in plasma samples obtained after single drug administration of mirtazapine to a healthy volunteer. 相似文献
18.
Determination of glutathione content in grape juice and wine by high-performance liquid chromatography with fluorescence detection 总被引:2,自引:0,他引:2
A modified preparation of sample was developed for the determination of glutathione content in grape juice and wine by high-performance liquid chromatography with fluorescence detection, using on-line pre-column derivatization. Ice-cold deoxygenated methanol was used to deactivate the oxidation enzymes in juices or wines and keep the glutathione stable. The optimum recovery of glutathione content in grape juice and wine was obtained when either the sample of grape juice or wine was mixed in ice-cold deoxygenated methanol in the ratio 10:90 (v:v) and further diluted in sodium acetate buffer in the ratio 1:1 (v:v). The optimized method was validated for linearity, limit of detection, limit of quantification, precision and uncertainty. According to the validation data the method is appropriate for the determination of glutathione content in grape juice and wine. Glutathione contents in grape juices made from White Muscat grapes and Sauvignon Blanc wines were analysed. The average glutathione content in 28 young Sauvignon Blanc wines was 12.5 mg L−1. 相似文献
19.
M. A. Garcia C. Solans A. Calvo M. Royo E. Hernandez R. Rey M. A. Bregante 《Chromatographia》2002,55(7-8):431-434
Summary A sensitive HPLC method has been developed for determination of ofloxacin (OFL) in biological fluids. Sample preparation was
performed by adding phosphate buffer (pH 7.4, 0.1m) then extraction with trichloromethane. OFL and the internal standard, sarafloxacin (SAR), were separated on a reversed-phase
column with aqueous phosphate solution-acetonitrile, 80∶20, as mobile phase. The fluorescence of the column effluent was monitored
at λex 338 and λem 425 nm. The retention times were 2.66 and 4.24 min for OFL and SAR, respectively, and the detection and quantitation limits
were 8 and 15 ng mL−1, respectively. Plots of response against ofloxacin concentration were linear in the range 8 to 2000 ng mL−1. Recovery was 92.9% for OFL. 相似文献
20.
建立了基于微乳液相色谱(MELC)的人血浆中丙泊酚浓度的测定方法。采用Hypersil BDS C18色谱柱分离,并考察了微乳流动相中各组分对溶质洗脱的影响。优化的色谱条件: 以0.5%醋酸(含有3.0%十二烷基硫酸钠(SDS),0.8%正庚烷,6.0%正丁醇)微乳为流动相,流速为1.0 mL/min,荧光检测器激发波长(λex)为274 nm、发射波长(λem)为312 nm,柱温为室温。人血浆样品用流动相稀释并离心后,直接进样分析。丙泊酚在0.25~10 μg/mL质量浓度范围内呈良好的线性关系,方法的回收率为(98.2±1.9)%~(104.6±2.2)%;日内测定峰面积的相对标准偏差(RSD)为1.42%~2.43%,日间测定峰面积的RSD为2.75%~4.79%。该方法简便可行、重复性好,可用于人血浆中丙泊酚浓度的测定。 相似文献