首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 62 毫秒
1.
A simple, sensitive, and specific method with gas chromatography-mass spectrometry was developed for simultaneous extraction and derivatization of amphetamines (APs) and 3,4-methylenedioxyamphetamines (MDAs) in human urine by using a monolithic silica spin column. All the procedures, such as sample loading, washing, and elution were performed by centrifugation. APs and MDAs in urine were adsorbed on the monolithic silica and derivatized with propyl chloroformate in the column. Methamphetamine-d5 was used as an internal standard. The linear ranges were 0.01-5.0 μg mL−1 for methamphetamine (MA) and 3,4-methylenedioxymethamphetamine (MDMA) and 0.02-5.0 μg mL−1 for amphetamine (AP) and 3,4-methylenedioxyamphetamine (MDA) (coefficient of correlation ≧0.995). The recovery of APs and MDAs in urine was 84-94%, and the relative standard deviation of the intra- and interday reproducibility for urine samples containing 0.1, 1.0, and 4.0 μg mL−1 of APs and MDAs ranged from 1.4% to 13.6%. The lowest detection limit (signal-to-noise ratio ≧ 3) in urine was 5 ng mL−1 for MA and MDMA and 10 ng mL−1 for AP and MDA. The proposed method can be used to perform simultaneous extraction and derivatization on spin columns that have been loaded with a small quantity of solvent by using centrifugation.  相似文献   

2.
Ternary mixtures of fluoroquinolones, with a 7-piperazinyl substituted group have been simultaneously determined in human urine samples by application of a multivariate calibration partial least squares (PLS) model. The calibration set was designed with 15 urine samples containing different concentrations of the three fluoroquinolones and 16 blank urine samples. The concentration range for the fluoroquinolones were up to 25 ng ml−1 for norfloxacin (NOR), 80 ng ml−1 for ofloxacin (OFLO) and 300 ng ml−1 for enoxacin (ENO). The method is based on the native fluorescence emission of these compounds in sodium dodecyl sulfate (SDS) medium, at pH 4.0, when exciting at 277 nm. A selection of the emission wavelength range used for the analysis was made for each component. Intraday and interday precision values were determined. Figures of merit as selectivity, sensitivity, limit of detection (LOD) and analytical sensitivity were also calculated. Using the standard addition methodology, five urine samples from five different persons, fortified with three concentration levels of the fluoroquinolones, were analyzed. The limits of detection in urine were 10.0, 0.5 and 0.8 ng ml−1 for ENO, NOR and OFLO, respectively.  相似文献   

3.
Based on direct hapten coated format a competitive indirect enzyme-linked immunosorbent assay (ciELISA) for bisphenol A (BPA) was developed. Polystyrene surface was modified by 3-Aminopropyltriethoxysilane (APTES) to produce amino groups after H2SO4/HNO3-pre-treatment. 4,4-bis (4-hydroxyphenyl) valeric acid (BVA) which is analogue of BPA, was successfully immobilized on the surface of microtiter plates by N,N′-dicyclohexylcarbodiimide (DCC) method. The essential steps of the assay were optimized, especially blocking procedure which is key step to prevent unspecific binding of antibody. The results indicated that compared with hapten-protein coated format (IC50 = 176.67 ng ml−1, LOD = 15.90 ng ml−1), the direct hapten coated format (IC50 = 23.50 ng ml−1, LOD = 0.27 ng ml−1) could improve assay sensitivity and the detection ranges were 2.30 ng∼157.60 ng ml−1 with good signal reproducibility (P value > 0.05) after careful optimization of assay conditions. Tap water samples and seawater samples were spiked with a known amount of BPA and measured by ciELISA. The average recoveries were between 70 and 142%. As far as we are aware this is the most sensitive ELISA for BPA yet reported.  相似文献   

4.
This paper presents two easy and selective methods for determining the active principles nafronyl (NFL) and naproxen (NAP), using a flow-through fluorescence optosensor based on the on-line immobilization on a nonionic-exchanger (Silica Gel, Davisil™ and Amberlite XAD 7, respectively) solid support. The determination was performed in 5×10−3 M HAc/NaAc buffer solution at pH 5 for NFL and 15×10−3 M glycine/HCl buffer solution at pH 2.5 for NAP at a working temperature of 20 °C. The fluorescence intensities were measured at λex/em=294/336 nm and λex/em=332/354 nm for NFL and NAP, respectively. The response time for these optosensors were practically instant, obtaining a linear concentration range between 0 and 700.0 ng ml−1 with a detection limit of 20.8 ng ml−1, an analytical sensitivity of 10.1 ng ml−1 and a standard deviation of 1.27% at a 500 ng ml−1 concentration level for NFL and a linear concentration range between 0 and 200.0 ng ml−1 with the detection limit of 13.3 ng ml−1, an analytical sensitivity of 6.0 ng ml−1 and a standard deviation of 3.52% at a 100 ng ml−1 concentration level for NAP. The proposed methods were satisfactorily applied to real samples (three commercial formulations and urine samples). The effects of the possible interferences were evaluated in all cases.  相似文献   

5.
Six polyclonal antisera to chloramphenicol (CAP) were successfully raised in camels, donkeys and goats. As a comparison of sensitivity, IC50 values ranged from 0.3 ng mL−1 to 5.5 ng mL−1 by enzyme-linked immunosorbent assay (ELISA) and from 0.7 ng mL−1 to 1.7 ng mL−1 by biosensor assay. The introduction of bovine milk extract improved the sensitivity of four of the antisera by ELISA and two by biosensor assay; a reduction in sensitivity of the remaining antisera ranged by a factor of 1.1-2.6. Porcine kidney extract reduced the sensitivity of all the antisera by a factor ranging from 1.1 to 7 by ELISA and a factor of 1.5 to 4 by biosensor. A low cross-reactivity with thiamphenicol (TAP) and florfenicol (FF) was displayed by antiserum G2 (1.2% and 18%, respectively) when a homologous ELISA assay format was employed. No cross-reactivity was displayed by any of the antisera when a homologous biosensor assay format was employed. Switching to a heterologous ELISA format prompted three of the antisera to display more significant cross-reactivity with TAP and FF (53% and 82%, respectively, using D1). The heterologous biosensor assay also increased the cross-reactivity of D1 for TAP and FF (56% and 129%, respectively) and of one other antiserum (G1) to a lesser degree. However, unlike the ELISA, the heterologous biosensor assay produced a substantial reduction in sensitivity (by a factor of 6 for D1).  相似文献   

6.
Three immunoassay systems: indirect, direct competitive enzyme-linked immunosorbent assay (IC-ELISA and DC-ELISA), fluorescence polarization immunoassay (FPIA) based on monoclonal antibodies for the detection of parathion-methyl (PM) were developed and optimized. Several PM derivatives (haptens) were conjugated to proteins and fluoresceinthiocarbamyl ethylenediamine (EDF) to obtain immunogens and competitors. The influence of immunogen and competitor structures on the assay performance was investigated. IC-ELISA was the most sensitive of all techniques developed, with a detection limit of 0.08 ng ml−1, but assay time was the longest (3.5 h per 96-well microtitre plate). DC-ELISA was easier to perform and quicker (1.5 h per 96-well microtitre plate) but less sensitive than IC-ELISA (detection limit was 0.5 ng ml−1). FPIA was the fastest and simplest (7 min per 10 samples) but the least sensitive (detection limit was 15 ng ml−1) technique. The methods were characterized by high specificity and reproducibility. The cross-reactivity for parathion-ethyl was around 30-40% for IC-ELISA and FPIA, but significantly higher (125%) for DC-ELISA. The immunoassays were applied to the analysis of PM residues in different food and environmental matrices. Methanol extracts of vegetable, fruit and soil samples were used for the analysis. Recoveries for most spiked samples averaged between 85 and 110%. The methods developed can be used for screening of food and environmental samples for PM residues without complicated clean-up.  相似文献   

7.
Yongqiang Cheng  Yuqin Su 《Talanta》2007,71(4):1757-1761
A novel assay of DNA has been proposed by using ferric nanoparticles as probes coupled with resonance light scattering (RLS) detection. At pH 7.40, the RLS intensity of ferric nanoparticles can be greatly enhanced by the aggregation of positively charged ferric nanoparticles through electrostatic interaction with negatively charged DNA. The enhanced intensity of RLS at 452 nm is proportional to the concentration of DNA in the range of 0.01-0.8 μg ml−1 for calf thymus and salmon sperm DNA and in the range of 0.005-0.3 μg ml−1 for E. coli K12 genomic DNA. Detection limits are 3.6 ng ml−1 for calf thymus DNA, 4.4 ng ml−1 for salmon sperm DNA, and 1.9 ng ml−1 for E. coli K12 genomic DNA, respectively. Compared with the chromophores previously used in RLS assay, the ferric nanoparticles have offered several advantages in easy preparation, good photostability and high sensitivity without being modified or functionalized.  相似文献   

8.
Liu R  Jia Y  Cheng W  Ling J  Liu L  Bi K  Li Q 《Talanta》2011,83(3):751-756
A simple and sensitive HPLC/Q-TOF MS method for simultaneous determination of 1,3-diaminopropane, putrescine, cadaverine, spermidine, spermine and acetyl-spermine in human urine was developed in electrospray-ionization source by positive ion mode. The samples were firstly pretreated by 10% HClO4 and then derivatized by benzoyl chloride with 1,6-diaminohexane as internal standard. The derived polyamines were separated on a C18 column by a gradient elution with methanol-water, and then sensitively detected with Q-TOF MS. The limits of detection for polyamines ranged from 0.02 to 1.0 ng ml−1 with excellent linearity within the range from 1 to 1000 ng ml−1 except acetyl-spermine from 5 to 1000 ng ml−1. The intra- and inter-day R.S.D. for all polyamines were 2.0-14.7% and 3.9-12.9%, respectively. The method was applied to determine the polyamines in human urine from 10 cancer patients and 15 healthy volunteers. Results showed that the mean levels of polyamines in urine of patients were all higher than those in healthy volunteers. The cluster analysis was used to establish the distinction mode between cancer sufferers and healthy individuals.  相似文献   

9.
Fenitrooxon [O,O-dimethyl-O-(4-nitro-m-tolyl)phosphate] is the major metabolite of the organophosphorus insecticide fenitrothion, and 3-methyl-4-nitrophenol is its major degradation product. In the present study, we describe the development of an indirect competitive enzyme-linked immunosorbent assay (ELISA) for the detection of these compounds in water samples based on a group-specific polyclonal antiserum generated with a “bifunctional hapten”, which has two functions: the conventional function of producing an antibody against an antigen and a unique function of promoting the production of the antibodies in rabbit. For application to water samples, the influence of several factors such as organic solvent, pH, and detergent was studied. Under optimized conditions, the quantitative working range of the fenitrooxon ELISA was 0.71-27 ng ml−1 with a limit of detection (LOD) of 0.32 ng ml−1, and the fenitrooxon concentration giving 50% reduction of the maximum signal (IC50) was 4.2 ng ml−1. The quantitative working range of the 3-methyl-4-nitrophenol ELISA was 0.67-27 ng ml−1 with a LOD of 0.38 ng ml−1 and an IC50 of 3.7 ng ml−1. No significant matrix effect originating from the water sample (river water, tap water, purified water, and bottled water) was shown by addition of Tween 20 to the assay buffer. Water samples spiked with each of these compounds at 1, 5, 10, and 20 ng ml−1 were directly analyzed without extraction and clean-up by the proposed ELISA. The mean recovery was 100.9%, and the mean coefficient of variation (CV) was 7.7% for the fenitrooxon ELISA and for the 3-methyl-4-nitrophenol ELISA, the mean recovery was 97.6%, and the mean CV was 7.2%. The proposed ELISA allows precise and accurate determination of these compounds in water at such low levels.  相似文献   

10.
A solid-phase microextraction (SPME) method for the determination of five amphetamine type stimulants (ATSs) in water and urine samples is presented. Analytes were simultaneously derivatized with iso-butyl chloroformate (iBCF) in the aqueous sample while being extracted, improving in this way the extractability of ATSs and permitting their determination by gas chromatography–mass spectrometry (GC–MS). The SPME procedure was carefully optimized in order to achieve adequate limits of detection (LODs) for environmental concentrations. Hence, different operational parameters were considered: type of SPME coating, ionic strength, basic catalyzer and derivatizing agent amount, extraction time and temperature. The final SPME procedure consists into the extraction of 100 mL of sample containing 2 g of dipotassium monohydrogen phosphate trihydrate and 100 μL of iBCF (1:1 in acetonitrile), for 40 min at 60 °C with a polydimethylsiloxane-divinylbenzene (PDMS-DVB) fiber. Under these conditions, LODs in wastewater ranged from 0.4 to 2 ng L−1, relative recoveries in the 84–114% range and relative standard deviations (RSD) lower than 15% were obtained. The application of the method to wastewater and river water samples showed the ecstasy ATS, 3,4-methylenedioxymethamphetamine (MDMA), as the most frequently detected, followed by methamphetamine, in concentrations around 20 ng L−1. Finally, the method was downscaled and also validated with urine samples, proving its good performance with this matrix too: RSD < 11%, recoveries in the 98–110% range and LODs lower than 0.1 μg L−1.  相似文献   

11.
A sensitive procedure has been developed for selenium and tellurium determination in milk by hydride generation atomic fluorescence spectrometry (HG-AFS) after microwave-assisted sample digestion. The method provides sensitivity values of 1591 and 997 fluorescence units ng−1 ml−1 with detection limits of 0.005 and 0.015 ng ml−1 for Se and Te, respectively. The application of the developed methodology to the analysis of cow milk samples of the Spanish market evidenced the presence of concentration ranges from 11.1 to 26.0 ng ml−1 for Se, and from 1.04 to 9.7 ng ml−1 for Te having found a good comparability with data obtained after dry-ashing of samples.  相似文献   

12.
《Analytica chimica acta》2003,491(1):47-56
We simultaneously determined carbendazim, fuberidazole and thiabendazole by excitation-emission matrix (EEM) fluorescence in combination with parallel factor analysis (PARAFAC). Three-way deconvolution provided the pure analyte spectra from which we estimated the selectivity and sensitivity of the pesticides, and the relative concentration in the mixtures from which we established a linear calibration. Special attention was given calculating such figures of merit as precision, sensitivity and limit of detection (LOD), derived from the univariate calibration curve. The method, which had a relative precision of around 2-3% for the three pesticides, provided limits of detection of 20 ng ml−1 for carbendazim, 4.7 ng ml−1 for thiabendazole and 0.15 ng ml−1 for fuberidazole. The accuracy of the method, evaluated through the root mean square error of prediction (RMSEP), was 27.5, 1.4, and 0.03 ng ml−1, respectively, for each of the pesticides.  相似文献   

13.
Sun Y  Tang Y  Yao H  Zheng X 《Talanta》2004,64(1):156-159
A sensitive flow injection chemiluminescence (FL-CL) method for the determination of cephalosporin antibiotics, was developed. The method was based on that cephalosporin antibiotics could enhance the CL reaction of glyoxal and KMnO4 in sulfuric acid. Method development included the optimization of reagent concentrations and flow-rate. Under the optimized conditions, three cephalosporin antibiotics: cefalexin, cefadroxil, and cefazolin sodium, were determined. The detection limits of the method are 10 ng ml−1 cefalexin, 2 ng ml−1 cefadroxil, and 2 ng ml−1 cefazolin sodium. The method was successfully applied to the determination of three cephalosporin antibiotics in pharmaceutical preparations.  相似文献   

14.
In the presented work, a disposable immunosensor for the detection of testosterone, an endogenous steroid hormone, in bovine urine has been developed using screen-printed electrodes (SPEs). Due to concerns over the use of steroid hormones as growth promoters, the EU prohibits their use in food producing animals. Consequently, rigorous screening procedures have been implemented in all member states to detect the illegal administration of such compounds. Competitive immunoassays were developed, initially by enzyme linked immunosorbent assay (ELISA), and subsequently transferred to an electrochemical immunosensor format using disposable screen-printed carbon electrodes. Horseradish peroxidase (HRP) was the enzyme label of choice and chronoamperometric detection was carried out using a tetramethylbenzidine/hydrogen peroxide (TMB/H2O2) substrate system, at +100 mV. The EC50 values obtained for the assay in buffer and urine gave relatively comparable results, 710 pg mL−1 and 960 pg mL−1, respectively. The linear range obtained for the assay in buffer extended from 0.03 ng mL−1 to 40 ng mL−1; while that in urine ranged from 0.03 ng mL−1 to 1.6 ng mL−1. The corresponding limits of detection (LOD) in buffer and urine were 26 pg mL−1 and 1.8 pg mL−1. Cross reactivity profiles of the antibody have been examined, with notable cross reactivities with 19-nortestosterone (11.6%) and boldenone (9.86%). Precision studies for the sensor demonstrated adequate reproducibility (CV < 13%, n = 3) and repeatability (CV < 9%, n = 3). Recovery data obtained showed good agreement between spiking studies and known concentrations of analyte. Sensors showed stability for 4 days at +4 °C. A sensitive, highly specific, inexpensive, disposable immunosensor, showing excellent overall performance for the detection of testosterone in bovine urine, has been developed.  相似文献   

15.
A simple and sensitive kinetic method for the determination of traces of mercury (70-760 ng ml−1) based on its inhibitory effect on the addition reaction between methyl green and sulfite ion is proposed. The reaction was monitored spectrophotometrically by measuring the decrease in absorbance of methyl green at 596 nm between 2 and 4 min using a fixed time method. Artificial neural networks with back propagation algorithm coupled with an orthogonal array design were applied to the modeling of the proposed kinetic system and optimization of experimental conditions. An orthogonal design was utilized to design the experimental protocol, in which pH, concentration of sulfite, temperature, and concentration of methyl green were varied simultaneously. Optimum experimental conditions in term of sensitivity were generated by using ANNs. The rate of decrease in absorbance is inversely proportional to the concentration of Hg(II) over entire concentration range tested (100-550 ng ml−1) with a detection limit of 45 ng ml−1 and a relative standard deviation at 200-400 ng ml−1 Hg(II) of 3.2% (n=5). A simple preconcentration step improved the limit of detection and linear dynamic range of the method to about 8 and 12-760 ng ml−1, respectively, by about 10 times enrichment of mercury between 12 and 75 ng ml−1. The method was based on enrichment of Hg(II) from dilute samples on an anionic ion exchanger fixed on a plastic strip and was applied to the determination of Hg(II) in environmental samples with satisfactory results.  相似文献   

16.
A novel kinetic chemiluminescent method using the stopped-flow mixing technique has been investigated for the rapid and sensitive determination of citrate and pyruvate. The method is based on a tris(2,2′-bipyridiyl)ruthenium(III) (Ru(bpy)33+) chemiluminescence (CL) reaction. Ru(bpy)33+ was generated in the mixing chamber by oxidising tris(2,2′-bipyridyl)ruthenium(II) with cerium(IV). After selecting the best operating parameters, calibration graphs were obtained over the concentration ranges 0.38-38 μg ml−1 and 8.7-1300 ng ml−1 for citrate and pyruvate, respectively. The limits of detection were 0.1 μg ml−1 for citrate and 0.3 ng ml−1 for pyruvate. Based on the differential rate of the chemiluminescent reaction corresponding to citrate and pyruvate, a very simple kinetic procedure was developed for the simultaneous determination of both compounds. Mixtures of citrate and pyruvate in ratios between 15:1 and 1.5:1 were satisfactorily resolved. The proposed method was successfully applied to the determination of citrate in pharmaceutical formulations, pyruvate in animal blood serum and both compounds in human urine.  相似文献   

17.
Hollow fiber membrane solvent microextraction (HFMSME) has been applied as a simple and efficient means of sample preparation for the screening of drugs of abuse in saliva. Extraction of cocaine and its metabolites from a 2 ml saliva solution was achieved in 10 min. This was followed by fast GC separation allowing complete analysis to be achieved in 15 min. Using HFMSME, detection limits ranged between 6 and 28 ng ml−1 with average relative standard deviations of 9.0%. The effect of the presence of various foodstuffs was also investigated.  相似文献   

18.
A novel immunochromatographic assay (ICA) was proposed for rapid and multiple assay of β2-agonists, by utilizing ractopamine (RAC) and salbutamol (SAL) as the models. Owing to the introduction of chemiluminescent (CL) approach, the proposed protocol shows much higher sensitivity. In this work, the described ICA was based on a competitive format, and horseradish peroxidase-tagged antibodies were used as highly sensitive CL probes. Quantitative analysis of β2-agonists was achieved by recording the CL signals of the probes captured on the two test zones of the nitrocellulose membrane. Under the optimum conditions, RAC and SAL could be detected within the linear ranges of 0.50–40 and 0.10–50 ng mL−1, with the detection limits of 0.20 and 0.040 ng mL−1 (S/N = 3), respectively. The whole process for multianalyte immunoassay of RAC and SAL can be completed within 20 min. Furthermore, the test strip was validated with spiked swine urine samples and the results showed that this method was reliable in measuring β2-agonists in swine urine. This CL-based multianalyte test strip shows a series of advantages such as high sensitivity, ideal selectivity, simple manipulation, high assay efficiency and low cost. Thus, it opens up new pathway for rapid screening and field analysis, and shows a promising prospect in food safety.  相似文献   

19.
Two novel enzyme immunoassays of fentanyl have been developed using Horseradish Peroxidase (HRP) as an enzyme, 3,3′,5,5′tetramethylbenzidine (TMB) and luminol as its colorimetric and its chemiluminescence substrate, respectively. A fentanyl polyclonal antibody was used as a capture antibody for fentanyl and fentanyl-bovine serum albumin (BSA) conjugate. The latter was first biotinylated and then bound by streptavidin labeled with HRP, resulting in the development of two novel competitive immunoassays. The detection limits were 0.045 and 0.0048 ng ml−1 for spectrophotometric and chemiluminescence detection, respectively, and were much lower than existing HRP-fentanyl based kits. Intra- and inter-assay CVs were 2.6-4.5 and 5.4-11.2%, respectively, at concentrations of 0.050-5.000 ng ml−1 for the colorimetric assay, whilst for the chemiluminescent assay intra- and inter-assay CVs were 3.7-6.2 and 6.2-12.3%, respectively, for the linear range of the assay at concentrations of 0.008-0.800 ng ml−1. The methods in this study were developed in order to measure maternal and neonatal fentanyl plasma samples during cesarean section, after the application of a novel subarachnoid analgesia technique. The 28 maternal and neonatal plasma samples were measured by both assays, providing data for subarachnoid administration of fentanyl that had never been presented before.  相似文献   

20.
A highly sensitive and relatively interference-free spectrophotometric method for determination of calcium is described. The method is based on the reaction between calcium ions and carboxyazo-p-CH3 in aqueous citrate medium of pH 7, to form a blue complex with maximum absorption at 716 nm. The calibration is linear up to 0.12 μg ml−1 calcium with a repeatability (R.S.D.) of 1.0% at a concentration of 0.04 μg ml−1 (n=5). The molar absorptivity of the complex and Sandell’s sensitivity are 3.5×105 l mol−1 cm−1 and 0.11 ng cm−2, its 10σ limit of quantification and the 3σ limit of detection were found to be 0.3 ng ml−1 and 0.09 ng ml−1 respectively. The influence of reaction variables and the effect of interfering ions are studied; no interference was observed in clinical samples. The proposed method has been applied directly to the determination of calcium in clinical samples without the need for pre-concentration, masking metal ions and digesting samples.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号