首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 890 毫秒
1.
Magnetic resonance imaging (MRI) is very useful spectroscopy to visualize a three-dimensional (3D) real structure inside the sample without physical destruction. The spatial resolution of the readily available MRI spectrometer is, however, limited by a few ten to hundreds of microns due to a technological boundary of generating larger magnetic field gradient and to the insensitivity inherent to the inductive signal detection. Magnetic resonance force microscopy (MRFM) is new alternative MRI spectroscopy which is anticipated to significantly surpass the conventional MRI in both resolution and sensitivity. We report two imaging experiments on our MRFM spectrometer operated at room temperature and in vacuum approximately 10(-3)Pa. One is for approximately 20 microm liposome membrane labeled entirely by a nitroxide imaging agent and the other for approximately 15 microm DPPH particles, both are nearly the same size as that of human cell. The reconstructed images at spatial resolution approximately 1 microm were in satisfactory agreement with the scanning electron microscope images. The potential capability of visualizing intrinsic radicals in the cell is suggested to investigate redox process from a microscopic point of view.  相似文献   

2.
We report on electron paramagnetic resonance (EPR) probing of magnetic fields and magnetic field gradients near the surface of a single crystal of the nanomagnet [Mn12O12(CH3COO)16(H2O)4].2CH3COOH.4H2O (Mn12-Ac). As the EPR probe, we utilized a 0.7 mm x 30 microm x 30 microm fibrous needle of the organic conductor N-methylphenazinium-tetracyanoquinodimethane (NMP-TCNQ), which yields an exceptionally sharp peak, with a 0.2 G (approximately 20 microT) width. In the presence of Mn12-Ac, the probe's peak exhibits splitting on temperature lowering, which depends on the orientation of the Zeeman field relative to the axis of easy magnetization of the employed Mn12-Ac crystal. The shifted peaks yield the magnitude of the magnetic field from Mn12-Ac crystal to which the various fibers of the probe are subjected. In conjunction with electron microscopy, the shifts yield the field gradient at the crystal surface and its change with temperature. For Mn12-Ac at 10 K, the surface magnetic field was measured to be in the mT range and its gradient on the order of 50 T/m.  相似文献   

3.
A new method of surface microscopy is proposed, which combines three-dimensional electron spin resonance imaging by magnetic resonance force microscopy (MRFM) and topographic imaging of the sample surface by scanning force microscopy (SFM). In order to demonstrate its potential for the identification of microscale objects, the individual and combined images are used to provide the locations, shapes and spin density distributions of target phantom objects. We report spatial resolution in MRFM of 2.8 x 2.8 x 2.0 microm(3). This could be improved to the theoretical limit of 0.08 x 0.08 x 0.04 microm(3) through reduction of the thermal noise by cooling to cryogenic temperatures approximately 0.5K. We believe that this type of microscopy will become a very useful tool for the investigation of anomalies induced in surfaces by materials buried below the surface.  相似文献   

4.
We tested the hypothesis that partial volume effects due to poor in-plane resolution and/or low temporal resolution used in clinical dynamic contrast-enhanced magnetic resonance imaging results in erroneous diagnostic information based on inaccurate estimates of tumor contrast agent extravasation and tested whether reduced encoding techniques can correct for dynamic data volume averaging. Image spatial resolution was reduced from 469 x 469 microm2 to those reported below by selecting a subset of k-space data. We then compared the top five K(trans)/V(T) "hot spots" obtained from the original data set, 469 x 469-microm in-plane spatial resolution and an 18-s temporal resolution processed by fast Fourier transform (FFT), with values obtained from data sets having in-plane spatial resolutions of 938 x 938, 1875 x 1875 and 2500 x 2500 microm2 and a temporal resolution of 18 s, or data sets with temporal resolutions of 36, 54 and 72 and a spatial resolution of 469 x 469 microm2, and found them to statistically differ from the parent data sets. We then tested four different post processing methods for improving the spatial resolution without sacrificing temporal resolution: zero-filled FFT, keyhole, reduced-encoding imaging by generalized-series reconstruction (RIGR) and two-reference RIGR (TRIGR). The top five values of K(trans)/V(T) obtained from data sets, the in-plane spatial resolutions of which were improved to 469 x 469 microm2 by zero-filling FFT, Keyhole and RIGR, statistically differed from those obtained from the original 469 x 469 microm2 FFT parent image data set. Only the 938 x 938 and 1875 x 1875 microm2 data sets reconstructed to 469 x 469 microm2 with TRIGR reconstruction method yielded values of the top five K(trans)/V(T) hot spots statistically the same as the original parent data set, 469 x 469 microm2 in-plane spatial and 18-s temporal-resolution FFT. That is, partial volume effects from data sets of different in-plane spatial resolution resulted in statistically different values of the top five K(trans)/V(T) hot spots relative to a high spatial and temporal resolution data set, and TRIGR reconstruction of these low resolution data sets to high resolution images provided statistically similar values with a savings in temporal resolution of 2 to 4 times.  相似文献   

5.
NMR microscopy is routinely employed in fields of science such as biology, botany, and materials science to observe magnetic parameters and transport phenomena in small scale structures. Despite extensive efforts, the resolution of this method is limited (>10 microm for short acquisition times), and thus cannot answer many key questions in these fields. We show, through theoretical prediction and initial experiments, that ESR microscopy, although much less developed, can improve upon the resolution limits of NMR, and successfully undertake the 1 mum resolution challenge. Our theoretical predictions demonstrate that existing ESR technology, along with advanced imaging probe design (resonator and gradient coils), using solutions of narrow linewidth radicals (the trityl family), should yield 64 x 64 pixels 2D images (with z slice selection) with a resolution of 1 x 1 x 10 microm at approximately 60 GHz in less than 1h of acquisition. Our initial imaging results, conducted by CW ESR at X-band, support these theoretical predictions and already improve upon the previously reported state-of-the-art for 2D ESR image resolution achieving approximately 10 x 10 mum, in just several minutes of acquisition time. We analyze how future progress, which includes improved resonators, increased frequency of measurement, and advanced pulsed techniques, should achieve the goal of micron resolution.  相似文献   

6.
The feasibility of in vivo high-resolution magnetic resonance micro-imaging of fine anatomic structures of human toes was tested. Five healthy subjects were investigated on an experimental 3 Tesla whole body scanner, using standard 3D gradient echo sequences. A radio-frequency surface coil was used for signal detection. Feet, toes and surface coil were comfortably fixed using a home built device for positioning and reduction of motion artifacts. The spatial resolution of 117 x 313 x 375 microm(3) allowed detailed visualization of anatomic structures like skin layers, vessels and nerves. In addition, oval structures with diameters ranging from 500 to 1000 microm were observed in all subjects, which could represent the sensory nerve endings of Vater-Pacinian bodies. Thus, high resolution MR micro-imaging at 3 Tesla may provide improved morphologic information in distal extremities of humans in vivo.  相似文献   

7.
We introduce a method for non-invasively mapping fiber orientation in materials and biological tissues using intermolecular multiple-quantum coherences. The nuclear magnetic dipole field of water molecules is configured by a CRAZED sequence to encode spatial distributions of material heterogeneities. At any given point r in space, we obtain the spherical coordinates of fiber orientation (theta,phi) with respect to the external field by comparing three signals ||G(X)||, ||(Y)||, and ||G(Z)|| (modulus), acquired with linear gradients applied along the X, Y, and Z axes, respectively. For homogeneous isotropic materials, a subtraction ||G(Z)|| - ||G(X)|| - ||G(Y)|| gives zero. With anisotropic materials, we find an empirical relationship relating ||G(Z)|| - ||G(X)|| - ||G(Y)||/(||G(X)|| + ||G(Y)|| + ||G(Z)||) to the polar angle theta, while ||G(X|| - ||G(Y)||/(||G(X)|| + ||G(Y)|| + ||G(Z)||) is related to the azimuthal angle phi. Experiments in structured media confirm the structural sensitivity. This technique can probe length scales not accessible by conventional MRI and diffusion tensor imaging.  相似文献   

8.
We demonstrate one-dimensional nuclear magnetic resonance imaging of the semiconductor GaAs with 170 nm slice separation and resolve two regions of reduced nuclear spin polarization density separated by only 500 nm. This was achieved by force detection of the magnetic resonance, magnetic resonance force microscopy (MRFM), in combination with optical pumping to increase the nuclear spin polarization. Optical pumping of the GaAs created spin polarization up to 12 times larger than the thermal nuclear spin polarization at 5K and 4T. The experiment was sensitive to sample volumes of 50 microm(3) containing approximately 4 x 10(11)71 Ga/Hz. These results demonstrate the ability of force-detected magnetic resonance to apply magnetic resonance imaging to semiconductor devices and other nanostructures.  相似文献   

9.
Dynamic magnetic resonance microscopy of flour dough fermentation   总被引:2,自引:0,他引:2  
Magnetic resonance microscopy was carried out at 9.4 T with a voxel volume of 117 x 117 x 500 microm(3) and temporal resolution was adjusted to 8.5 min for a dynamic follow-up of bread dough fermentation during 2 h at a constant temperature of 30 degrees C. An image analysis procedure based on gray levels mathematical morphology routines was performed to assess bubble distribution and cell wall thickness inside the imaged bread dough. The evolution of the extracted curves allows one to characterize quantitatively the amount of bubbles and their growth. Using this procedure, different bread doughs were examined to determine the impact of dough composition on the structure modification during fermentation.  相似文献   

10.
Conventional high resolution nuclear magnetic resonance (NMR) spectra are usually measured in homogeneous, high magnetic fields (>1 T), which are produced by expensive and immobile superconducting magnets. We show that chemically resolved xenon (Xe) NMR spectroscopy of liquid samples can be measured in the Earth's magnetic field (5 x 10(-5) T) with a continuous flow of hyperpolarized Xe gas. It was found that the measured normalized Xe frequency shifts are significantly modified by the Xe polarization density, which causes different dipolar magnetic fields in the liquid and in the gas phases.  相似文献   

11.
While the inherent low sensitivity of in vivo MR spectroscopy motivated a trend towards higher magnetic fields, B(0), it has since become apparent that this increase does not seem to translate into the anticipated improvement in spectral resolution. This is attributed to the decrease of the transverse relaxation time, T(2)*, in vivo due to macro- and mesoscopic tissue susceptibility. Using spectral contrast-to-noise ratio (SCNR) arguments, we show that if in biological systems the linewidth (on the frequency scale) increases linearly with the field, the spectral resolution (in parts per million) improves approximately as the fifth-root of B(0) for chemically shifted lines and decreases as about B(0)(4/5) (in hertz) for a structure of J-coupled multiplets. It is also shown that for any given B(0) there is a unique voxel size that is optimal in spectral resolution, linking the spectral and spatial resolutions. Since in practical applications the spatial resolution may be dictated by the target anatomy, nomograms to determine the B(0) required to achieve the desired spectral resolution at that voxel size are presented. More generally, the scaling of the nomograms to determine the achievable spectral and spatial resolutions at any given field is described.  相似文献   

12.
The magnetic field induced in the pores of trabecular bone as a result of the susceptibility difference between bone and bone marrow was computed with the aid of magnetic surface charge models generated from images of trabecular bone specimens acquired at 78 and 63 microm resolution. The predicted field was compared with the values derived from 2D and 3D field maps obtained by echo-offset imaging techniques and excellent agreement was found between the two methods. Finally, from the slopes of regression between the experimental and computed fields, the absolute susceptibility of bone was nondestructively determined as -11.0 x 10(-6) (MKS), which is in close agreement with a reported value of -11.3 x 10(-6) obtained with powdered bone by means of a spectroscopic susceptibility matching technique (J. A. Hopkins and F. W. Wehrli, Magn. Reson. Med. 37, 494-500 (1997)).  相似文献   

13.
Inelastic collision rates for ultracold 85Rb atoms in the F = 2, m(f) = -2 state have been measured as a function of magnetic field. At 250 gauss (G), the two- and three-body loss rates were measured to be K2 = (1.87+/-0.95+/-0.19)x10(-14) cm(3)/s and K3 = (4.24(+0. 70)(-0.29)+/-0.85)x10(-25) cm(6)/s, respectively. As the magnetic field is decreased from 250 G towards a Feshbach resonance at 155 G, the inelastic rates decrease to a minimum and then increase dramatically, peaking at the Feshbach resonance. Both two- and three-body losses are important, and individual contributions have been compared with theory.  相似文献   

14.
ESR spectra of a laboratory synthesized kerosene base magnetic fluid containing ultrafine magnetic particles (average diameter of 100A) of Zn0.1 Fe0.9Fe2O4 are recorded at different temperatures. A narrow signal was observed above the melting point of the carrier liquid (200 K) which can be attributed to a very small volume fraction of superparamagnetic particles in the system. The peak-to-peak line width for both low and high field cooled configurations show an increase with decreasing temperature. This observed behaviour has been explained by considering various energy terms which contribute to the line width.  相似文献   

15.
Proton magnetic resonance (1H magnetic resonance imaging (MRI)) images of human trabecular bone were acquired and discussed for two samples with different porosity. Three-dimensional 3D Spin Echo (3D SE) and Multi-Slice Multi-Echo (MSME) pulse sequences were examined. A very high slice resolution of (38 microm)2 was achieved (MSME). The intensity histograms were found useful for the characterization of the bone porosity. A spatial distribution of the spin-spin relaxation time T2 was monitored with the MSME pulse program. The work demonstrates the great potential of the proton MRI technique in the study of the trabecular bone morphology.  相似文献   

16.
The high sensitivity but low specificity of breast MRI has prompted exploration of breast (1)H MRS for breast cancer detection. However, several obstacles still prevent the routine application of in vivo breast (1)H MRS, including poor spatial resolution, long acquisition time associated with conventional multi-voxel MRS imaging (MRSI) techniques, and the difficulty of "extra" lipid suppression in a magnetic field with relatively poor achievable homogeneity compared to the brain. Using a combination of a recently developed echo-filter (EF) suppression technique and an elliptical sampling scheme, we demonstrate the feasibility of overcoming these difficulties. It is robust (the suppression technique is insensitive to magnetic field inhomogeneity), fast (acquisition time of about 12 min) and offers high spatial resolution (up to 0.6 cm(3) per voxel at 1.5 T with a TE of only 60 ms). This approach should be even better at 3 T with higher resolution and/or shorter TE.  相似文献   

17.
18.
A scanning Hall probe microscope that is capable of observing both topographic and magnetic images simultaneously has been developed by constructing a conducting needle, used for the scanning tunneling microscope (STM) measurements, adjacent to the Hall junction of 0.6 μm square. The needle also enables the Hall probe to approach the sample without contact and to scan just above it with close proximity. Morphologies and local magnetic distributions on the surfaces of magnetic recording media, observed by our microscope, indicates that lateral spatial resolution is better than 1 μm for both STM and magnetic measurements.  相似文献   

19.
We present the design process of a superconducting volume coil for magnetic resonance microscopy of the mouse brain at 9.4T. The yttrium barium copper oxide coil has been designed through an iterative process of three-dimensional finite-element simulations and validation against room temperature copper coils. Compared to previous designs, the Helmholtz pair provides substantially higher B(1) homogeneity over an extended volume of interest sufficiently large to image biologically relevant specimens. A custom-built cryogenic cooling system maintains the superconducting probe at 60+/-0.1K. Specimen loading and probe retuning can be carried out interactively with the coil at operating temperature, enabling much higher through-put. The operation of the probe is a routine, consistent procedure. Signal-to-noise ratio in a mouse brain increased by a factor ranging from 1.1 to 2.9 as compared to a room-temperature solenoid coil optimized for mouse brain microscopy. We demonstrate images encoded at 10x10x20mum for an entire mouse brain specimen with signal-to-noise ratio of 18 and a total acquisition time of 16.5h, revealing neuroanatomy unseen at lower resolution. Phantom measurements show an effective spatial resolution better than 20mum.  相似文献   

20.
Spatially varying primordial magnetic fields may be efficiently dissipated prior to the epoch of recombination due to the large viscosity of the baryon-photon fluid. We show that this dissipation may result in observable chemical potential &mgr; and Compton y distortions in the cosmic microwave background spectrum. Current upper limits on &mgr; and y from FIRAS constrain magnetic fields to have strength B0<3x10(-8) G (scaled to the present) between comoving coherence length approximately 400 pc and approximately 0.6 Mpc. These represent the strongest upper limits on small-scale primordial magnetic fields to date.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号