首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Lesaicherre ML  Li SF  Lee HK 《Electrophoresis》2000,21(7):1336-1340
Female birds possess one Z and one W chromosome, whereas male birds possess two identical Z chromosomes. Thus, the presence of a W genetic marker is diagnostic of the female sex. Capillary electrophoresis with buffer containing an entangled solution of hydroxyethylcellulose was used to separate the polymerase chain reaction (PCR) amplified bird sexing genes CHD-Z and CHD-W. The relative standard deviations (RSD) were less than 0.6% for the male genes and less than 0.4% for the female genes for six runs and detection limits of 0.1 ng/microL were obtained with laser-induced fluorescence (LIF) detection. Using a DNA ladder and theoretical models for DNA separation in sieving media, the sizes of the two bird genes were determined.  相似文献   

2.
Capillary electrophoresis (CE) is a new, high-resolution tool for the analysis of DNA restriction fragments and DNA amplified by the polymerase chain reaction (PCR). By combining many of the principles of traditional slab gel methods in a capillary format, it is possible to perform molecular size determinations of human and plant PCR amplification products and DNA restriction fragments. DNA restriction fragments and PCR products were analyzed by dynamic sieving electrophoresis (DSE) and capillary gel electrophoresis (CGE). As part of this study, sample preparation procedures, injection modes, and the use of molecular mass markers were evaluated. Optimum separations were performed using the uPage-3 (3% T, 3% C) CGE columns with UV detection at 260 nm. Membrane dialysis and ultrafiltration/centrifugation proved to be nearly equivalent methods of sample preparation. Reproducibility studies demonstrated that blunt-ended, non-phosphorylated markers (specifically allele generated markers) provide the most accurate calibration for PCR product analysis. This study demonstrates that CE offers a high-speed, high-resolution analytical method for accurately determining molecular size and/or allelic type as compared with traditional methodologies.  相似文献   

3.
Over the past years, the development of capillary electrophoresis (CE) and microchip electrophoresis (ME) systems has grown due to instrumental simplicity and wide application. In both CE and ME, the application of a high voltage (HV) is a crucial step in the electrokinetic (EK) injection and separation processes. Particularly on ME devices, EK injection is often performed with three different modes: gated, pinched, and unpinched. In all these cases, different potential values may be applied to one or multiple channels to control the injection of small sample volumes as well as the separation process. For this reason, the construction of reliable HV power supplies (HVPS) is required. This review covers the advances of the development of commercial and laboratory-built HVPS for CE and ME. Moreover, it intends to be a guide for new developers of electrophoresis instrumentation.  相似文献   

4.
5.
Carbon nanotubes are among the plethora of novel nanostructures developed since the 1980s. Nanotubes have attracted considerable interest by the scientific community thanks to their extraordinary physical and chemical properties. Research areas have flourished in recent years and now include the nano-electronic, (bio)sensor and analytical field along with many others. This review covers applications of carbon nanotubes in capillary electrophoresis, capillary electrochromatography and microchip electrophoresis. First, carbon nanotubes and a range of electrophoretic techniques are briefly introduced and key references are mentioned. Next, a comprehensive survey of achievements in the field is presented and critically assessed. The merits and downsides of carbon nanotube addition to the various capillary electrophoretic modes are addressed. The different schemes for fabricating electrochromatographic stationary phases based on carbon nanotubes are discussed. Finally, some future perspectives are offered.   相似文献   

6.
A variety of rearrangements in the low-density lipoprotein receptor (LDLR) gene cause severe forms of familial hypercholesterolemia (FH). However, current methods for searching these abnormalities in FH samples, e.g., Southern and Northern Blot, are labor-intensive and not routinely used by diagnostic laboratories. We developed a simpler approach based on the quantitative polymerase chain reaction (PCR) amplification of part or all gene's coding sequences by a series of multiplex amplifications comprising three nonadjacent gene sections plus a fourth section used as an internal reference. Thereafter, the analysis of these PCR products by microchip electrophoresis revealed either deletions or duplications in the investigated gene sections through the simple comparison of electropherograms obtained from mutant and control samples. This required primers leading to well-resolved peaks with minimal size differences among coamplified products and PCR conditions allowing a linear quantitative response to template amount variations as those caused by duplication or deletion of specific gene sections. Also, the inclusion of exon 17 amplification product as an internal reference in each multiplex PCR allowed the normalization of quantitative results by dividing the area of each amplified section by the area of exon 17. The comparison of these ratios calculated from 10 carriers of 6 LDLR known rearrangements with those obtained from 14 control samples showed that gross deletions roughly halved and duplications doubled the ratio values of exons involved in the mutation. This allowed to distinguish gross mutations from sample-to-sample differences that reached at maximum 8% variation over mean values.  相似文献   

7.
It has been recently demonstrated that single-stranded DNA-binding protein (SSB) can facilitate quantitative analyses of DNA, RNA, and proteins in gel-free capillary electrophoresis (CE). Here, we report the application of SSB-mediated gel-free CE for analyses of polymerase chain reaction (PCR) products. The unique ability of SSB to bind ssDNA but not double-stranded DNA (dsDNA) allows efficient separation of three types of DNA molecules in the PCR reaction mixture: primers, products (amplified templates), and by-products, which originate from non-specific DNA hybridization. SSB-mediated gel-free CE analysis of PCR products combines simplicity, high sensitivity, and outstanding quantitative capabilities. The ability of the method to distinguish between products and by-products makes this method an indispensable tool in preparative PCR (e.g., in the development of nucleotide aptamers).  相似文献   

8.
Zhang Y  He Y  Yeung ES 《Electrophoresis》2001,22(11):2296-2302
Routine genetic analysis of large numbers of individuals by polymerase chain reaction (PCR) using capillary electrophoresis is often restricted by the low throughput of standard protocols and the tedious sample preparation process. Here, we demonstrate that capillary electrophoresis with UV detection can be used in PCR-based DNA analysis starting from clinical samples without purification or complicated sample manipulation. After PCR reaction using cheek cells, blood, or HIV-1 gag DNA, the reaction mixtures were injected into a capillary array either on-line or off-line by base stacking. The use of multiplexed absorption detection and the elimination of any purification steps both before and after PCR reaction can potentially provide significant benefits compared to current methods for DNA analysis with regard to time, cost, and labor.  相似文献   

9.
A circular ferrofluid driven microchip for rapid polymerase chain reaction   总被引:4,自引:0,他引:4  
Sun Y  Kwok YC  Nguyen NT 《Lab on a chip》2007,7(8):1012-1017
In the past few years, much attention has been paid to the development of miniaturized polymerase chain reaction (PCR) devices. After a continuous flow (CF) PCR chip was introduced, several CFPCR systems employing various pumping mechanisms were reported. However, the use of pumps increases cost and imposes a high requirement on microchip bonding integrity due to the application of high pressure. Other significant limitations of CFPCR devices include the large footprint of the microchip and the fixed cycle number which is dictated by the channel layout. In this paper, we present a novel circular close-loop ferrofluid driven microchip for rapid PCR. A small ferrofluid plug, containing sub-domain magnetic particles in a liquid carrier, is driven by an external magnet along the circular microchannel, which in turn propels the PCR mixture through three temperature zones. Amplification of a 500 bp lambda DNA fragment has been demonstrated on the polymethyl methacrylate (PMMA) PCR microchip fabricated by CO(2) laser ablation and bonded by a low pressure, high temperature technique. Successful PCR was achieved in less than 4 min. Effects of cycle number and cycle time on PCR products were investigated. Using a magnet as the actuator eliminates the need for expensive pumps and provides advantages of low cost, small power consumption, low requirement on bonding strength and flexible number of PCR cycles. Furthermore, the microchip has a much simpler design and smaller footprint compared to the rectangular serpentine CFPCR devices. To demonstrate its application in forensics, a 16-loci short tandem repeat (STR) sample was successfully amplified using the PCR microchip.  相似文献   

10.
CE on microchip is an emerging separation technique that has attracted wide attention and gained considerable popularity. Because of miniaturization of the separation format, CE on chip typically offers shorter analysis time and lower reagent consumption with potential development of portable analytical instrumentation. This review with 143 references is focused on proteins and peptides analysis, DNA separation including fragment sizing, genotyping, mutation detection and sequencing, and also the analysis of low-molecular-weight compounds, namely explosive residues and warfare agents, pharmaceuticals and drugs of abuse, and various small molecules in body fluids.  相似文献   

11.
Capillary polymer electrophoresis is identified as a promising technology for the analysis of DNA from bacteria, virus and cell samples. In this paper, we propose an innovative capillary polymer electrophoresis protocol for the quantification of polymerase chain reaction products. The internal standard method was modified and applied to capillary polymer electrophoresis. The precision of our modified internal standard protocol was evaluated by measuring the relative standard deviation of intermediate capillary polymer electrophoresis experiments. Results showed that the relative standard deviation was reduced from 12.4–15.1 to 0.6–2.3%. Linear regression tests were also implemented to validate our protocol. The modified internal standard method showed good linearity and robust properties. Finally, the ease of our method was illustrated by analyzing a real clinical oral sample using a one‐run capillary polymer electrophoresis experiment.  相似文献   

12.
A new end-column ‘hybrid’ contactless conductivity detector for microchip capillary electrophoresis (CE) was developed. It is based on a “hybrid” arrangement where the receiving electrode is insulated by a thin layer of insulator and placed in the bulk solution of the detection reservoir of the chip, whereas the emitting electrode is in contact with the solution eluted from the channel outlet in a wall-jet arrangement. The favorable features of the new detector including the high sensitivity and low noise, can be attributed to both the direct contact of the ‘emitting’ electrode with the analyte solution as well as to the insulation of the detection electrode from the high DC currents in the electrophoretic circuit. Such arrangement provides a 10-fold sensitivity enhancement compared to currently used on-column contactless conductivity CE microchip detector as well as low values of noise and easy operation. The new design of the wall-jet conductivity detector was tested for separation of explosive-related methylammonium, ammonium, and sodium cations. The new detector design reconsiders the wall-jet arrangement for microchip conductivity detection in scope of improved peak symmetry, simplified study of inter-electrode distance, isolation of the electrodes, position of the wall-jet electrode to the separation channel, baseline stability and low limits of detection.  相似文献   

13.
Recent advances and key strategies in capillary electrophoresis and microchip CE with electrochemical detection (ECD) and electrochemiluminescence (ECL) detection are reviewed. This article consists of four main parts: CE-ECD; microchip CE-ECD; CE-ECL; and microchip CE-ECL. It is expected that ECD and ECL will become powerful tools for CE microchip systems and will lead to the creation of truly disposable devices. The focus is on papers published in the last two years (from 2005 to 2006).  相似文献   

14.
Herein, we summarize the current status of native fluorescence detection in microchannel electrophoresis, with a strong focus on chip-based systems. Fluorescence detection is a powerful technique with unsurpassed sensitivity down to the single-molecule level. Accordingly fluorescence detection is attractive in combination with miniaturised separation techniques. A drawback is, however, the need to derivatize most analytes prior to analysis. This can often be circumvented by utilising excitation light in the UV spectral range in order to excite intrinsic fluorescence. As sensitive absorbance detection is challenging in chip-based systems, deep-UV fluorescence detection is currently one of the most general optical detection techniques in microchip electrophoresis, which is especially attractive for the detection of unlabelled proteins. This review gives an overview of research on native fluorescence detection in capillary (CE) and microchip electrophoresis (MCE) between 1998 and 2008. It discusses material aspects of native fluorescence detection and the instrumentation used, with particular focus on the detector design. Newer developments, featured techniques, and their prospects in the future are also included. In the last section, applications in bioanalysis, drug determination, and environmental analysis are reviewed with regard to limits of detection.  相似文献   

15.
This paper presents an inexpensive and easy-to-implement voltage sequencer instrument for use in microchip capillary electrophoresis (MCE) actuation. The voltage sequencer instrument takes a 0–5 V input signal from a microcontroller and produces a reciprocally proportional voltage signal with the capability to achieve the voltages required for MCE actuation. The unit developed in this work features four independent voltage channels, measures 105 × 143 × 45 mm (width × length × height), and the cost to assemble is under 60 USD. The system is controlled by a peripheral interface controller and commands are given via universal serial bus connection to a personal computer running a command line graphical user interface. The performance of the voltage sequencer is demonstrated by its integration with a fluorescence spectroscopy MCE sensor using pinched sample injection and electrophoretic separation to detect ciprofloxacin in samples of milk. This application is chosen as it is particularly important for the dairy industry, where fines and health concerns are associated with the shipping of antibiotic-contaminated milk. The voltage sequencer instrument presented represents an effective low-cost instrumentation method for conducting MCE, thereby making these experiments accessible and affordable for use in industries such as the dairy industry.  相似文献   

16.
Electrokinetic supercharging (EKS) is considered as one of the most powerful online preconcentration techniques in electrophoresis. It combines the efficient preconcentration power of field-amplified sample injection and the exceptional selective nature of transient isotachophoresis. It has a wide range of applications to different types of analytes ranging from small ions to large proteins and DNA fragments. This comprehensive review--up to date--provides listing for all the works, developments, and advances in EKS. The review will pay particular attention to innovations, new methodologies for manipulation, challenges for improving the detection sensitivity, and various applications of EKS in capillaries and microchips.  相似文献   

17.
In this work, a capillary electrophoretic method for the rapid quantitation of atorvastatin (AT) in a lipitor tablet was investigated and developed. Method development included studies of the effect of applied potential, buffer concentration, buffer pH, and hydrodynamic injection time on the electrophoretic separation. The method was validated with regard to linearity, precision, specificity, LOD, and LOQ. The optimum electrophoretic separation conditions were 25 mM sodium acetate buffer at pH 6, with a separation voltage of 25 kV using a 50 microm capillary of 33 cm total length. Sodium diclofenac was used as an internal standard. Analysis of AT in a commercial lipitor tablet by electrophoresis gave quite high efficiency, coupled with an analysis time of less than 1.2 min in comparison to LC. Once the separation was optimized on capillary, it was further miniaturized to a microchip platform, with linear imaging UV detection using microchip electrophoresis (MCE). Linear imaging UV detection allowed for real-time monitoring of the analyte movement on chip, so that the optimum separation time could be easily determined. This microchip electrophoretic method was compared to the CE method with regard to speed, efficiency, precision, and LOD. This work represents the most rapid and first reported analysis of AT using MCE.  相似文献   

18.
Two single nucleotide polymorphisms (SNPs) of 5,10-methylenetetrahydrofolate reductase (MTHFR) gene, A1298C and C677T, were widely considered to be related with various neoplasia disorders. We established a simple and effective capillary electrophoresis (CE) method for detection of two SNPs in MTHFR gene simultaneously. DNA samples were amplified by multiplex PCR with universal fluorescence-labeled primer and analyzed by single-strand conformation polymorphism (SSCP)-CE method. The CE method was performed using 1.5% hydroxyethyl cellulose in 1× TBE buffer containing 1 M urea. The PCR products after SSCP procedure were electrokinetically injected at −10 kV, 30 s. Separation voltage was −6 kV and the temperature was set at 20 °C. The optimal SSCP-CE method was applied to detect two polymorphisms in MTHFR gene of acute lymphoblastic leukemia (ALL) and attention-deficit/hyperactivity disorder (ADHD) patients. Genotyping results were evaluated in terms of relationships between outcomes for ADHD patients after ALL chemotherapy and ALL disease. The SSCP-CE method and multiplex PCR with universal fluorescence primer were used as the fast technique for screening two SNPs in MTHFR gene, A1298C and C677T. The genotyping data were coincident with DNA sequencing. This SSCP-CE method was found feasible for detecting mutation of MTHFR gene in populations.  相似文献   

19.
We report an accurate and reproducible DNA quantitation method using the polymerase chain reaction (PCR). The amount of PCR product is monitored after each PCR cycle by capillary electrophoresis. To ensure accurate quantitation, a non-amplified internal standard is added to each PCR-amplified electrophoresis sample to correct for variations in injection volume. Quantitation of the sample is based on the number of cycles necessary to generate a predetermined amount of PCR product. Duck hepatitis B virus genome was used as a model in this study. The genome was quantified with a linear relationship between cycle number and logarithm of sample DNA for amounts of sample DNA between 30 and 3.1 x 10(8) copies ( r(2)>0.999). The relative standard deviation for the corrected capillary electrophoresis signal was 2.7%, while the relative standard deviation for the overall assay was 3.0%. Results from a single-blind study generated a relative error of 1.3%.  相似文献   

20.
设为首页 | 免责声明 | 关于勤云 | 加入收藏