共查询到20条相似文献,搜索用时 15 毫秒
1.
Microwave-assisted extraction of OCPs, PCBs and PAHs concentrated by semi-permeable membrane devices (SPMDs) 总被引:1,自引:0,他引:1
Microwave-assisted extraction (MAE) has been evaluated as an alternative to dialysis for extraction of some water-borne hydrophobic contaminants sampled by semi-permeable membrane devices (SPMDs). Seven organochlorine pesticides (OCPs), 11 polychlorinated biphenyls (PCBs) and 13 polycyclic aromatic hydrocarbons (PAHs) were accumulated in SPMDs at nanogram levels and extracted with three 3-min irradiation cycles with 33 mL of a solvent mixture hexane–water (10:1,v/v) in each cycle. The developed MAE method gave for all analytes investigated statistically comparable extraction yields with those found by dialysis carried out with a total volume of 250 mL hexane for 48 h at room temperature. The recoveries of all the targeted contaminants were in the range of 65–105% with variation coefficients not exceeding 19%. The applicability of the MAE extraction was tested in field SPMDs samples deployed for 15 days in a sewage-treatment process. Our results show that MAE provides a remarkable reduction of time and solvent volume when used as an extraction method in the analysis of SPMDs. 相似文献
2.
Microwave-assisted extraction (MAE) has been evaluated as an alternative to dialysis for the extraction of polybrominated diphenyl ethers (PBDEs) and polychlorinated naphthalenes (PCNs) sampled by semipermeable membrane devices (SPMDs), using gas chromatography coupled to tandem mass spectrometry (GC-MS-MS).For MAE optimization a two level full factorial design 23, plus a centre point, which involves 11 randomized runs was used. The results showed that the temperature had a significant influence on the extraction of the nine PBDEs and four PCNs tested. Also, the solvent volume had a positive influence on the extraction of PBDEs and PCNs, but only in latter compounds, it achieves statistical significance. The time had only statistical significance for the most volatile specie studied, PCN-54. The selected MAE conditions (60 mL of hexane-acetone, 1:1 (v/v), 85 °C, 1 min, two cycles) lead to recoveries between 72 and 91% for PBDEs and between 96 and 103% for PCNs. The applicability of the MAE extraction was tested in field SPMDs deployed for 20 days in a sewage treatment plant.The MAE method developed is about 300 times faster than the conventional dialysis and remarkably reduces the solvent consumption. 相似文献
3.
Microwave-assisted solvent extraction of persistent organochlorine pesticides (POPs) in marine sediment was developed and optimized by means of two-level factorial designs. Six variables (microwave power, extraction time and temperature, amount of sample, solvent volume, and sample moisture) were considered as factors in the optimization process. The results show that the amount of sample to be extracted and solvent volume are statistically significant for the overall recovery of the studied pesticides, although compromise conditions have to be established with the object of avoiding overpressure in closed vessels. After extraction, a clean up step including the use of a silica cartridge was performed prior to chromatographic determination in order to remove interferences. The optimized procedure was compared to conventional Soxhlet extraction. The MS-MS ion preparation mode was applied to improve the sensitivity and selectivity of the chromatographic technique. 相似文献
4.
Ana M. Zuluaga Adal Mena-García Diana Chito-Trujillo Maite Rada-Mendoza María L. Sanz Ana I. Ruiz-Matute 《Electrophoresis》2020,41(20):1804-1811
A microwave-assisted extraction (MAE) method was developed for the extraction of bioactive inositols (D-chiro- and myo-inositols) from lettuce (Lactuca sativa) leaves as a strategy for the revalorization of these agrofood residues. Gas chromatography-mass spectrometry was selected for the simultaneous determination of inositols and sugars (glucose, fructose, and sucrose) in these samples. A Box–Behnken experimental design was used to maximize the extraction of inositols based on the results of single factor tests. Optimal conditions of the extraction process were as follows: liquid-to-solid ratio of 100:1 v/w, 40°C, 30 min extraction time, 20:80 ethanol:water (v/v), and one extraction cycle. When compared with conventional solid-liquid extraction (SLE), MAE was found to be more effective for the extraction of target bioactive carbohydrates (MAE 5.42 mg/g dry sample versus SLE 4.01 mg/g dry sample). Then, MAE methodology was applied to the extraction of inositols from L. sativa leaves of different varieties (var. longifolia, var. capitata and var. crispa). D-chiro- and myo-inositol contents varied between 0.57–7.15 and 0.83–3.48 mg/g dry sample, respectively. Interfering sugars were removed from the extracts using a biotechnological procedure based on the use of Saccharomyces cerevisiae for 24 h. The developed methodology was a good alternative to classical procedures to obtain extracts enriched in inositols from lettuce residues, which could be of interest for the agrofood industry. 相似文献
5.
Some data on a newly developed filter/sorbent indoor air SVOC sampling device for thermal desorption analyiss are described. Thermal desorption of SVOCs spiked on Tenax had reponse factors identical to on-column injection except for highly polar compounds like fatty acids. SVOCs spiked on quartz fiber filters had response factors that on an average were 80% of the on-column response factors (66% for oxygen containing compounds and 87% for non-oxygen compounds) Low nanogram on-tube amounts of SVOCs were found generally to have lower recoveries than larger amounts from both Tenax and quart fiber filters. This appeared to be explained in part by a relatively larger “memory” effect and lower desorption efficiency. In addition, it was indicated that the “memory” effect was an important source of background contaminations that might impair analysis of low nanogram on-tube amounts of some SVOCs. Polar SVOCs. Polar SVOCs in the gas phase appear to adsorbto the quartz fiber filters. This functions as a precleaning of the sample and thus minimizes the problem with coeluting peaks. The relative standard from nine duplicate samples appeared to be sufficiently low to distinguish a day variation. 相似文献
6.
Setková L Hajslová J Bergqvist PA Kocourek V Kazda R Suchan P 《Journal of chromatography. A》2005,1092(2):170-181
Semipermeable membrane devices (SPMD) represent a passive sampling technology that is becoming widely used for monitoring of surface waters pollution. While "classic" procedures employ dialysis to recover target compounds from exposed SPMDs, in the present study analytes were isolated from cut membrane together with sequestering medium (triolein) using hexane as an extraction solvent. This approach allowed us to reduce the time needed for accomplishment of isolation step from 48 h to only 1 h. Automated gel permeation chromatography (GPC) clean-up is employed in the following step to separate triolein from analytes fraction. Musk compounds (MCs), polychlorinated biphenyls (PCBs), brominated flame retardants (BFRs) and several other persistent organochlorine compounds (OCs) were determined in the respective fraction by GC method employing selective detectors (MSD, ECD). As shown in a series of analyses of SPMDs deployed in various aquatic ecosystems, high recoveries and good repeatability of results together with a possibility to obtain the information on the pollution of sampling site at the day of sample arrival to laboratory make this newly implemented procedure an interesting alternative to time consuming dialysis. 相似文献
7.
以亚胺连接的多孔共价有机骨架材料(IL-COF-1)作为固相萃取的吸附剂,建立了液相色谱-串联质谱快速检测蜂蜜样品中痕量雌激素的方法。该研究选择雌二醇、己烯雌酚、雌三醇、β-雌二醇和炔雌醇5种雌激素作为目标分析物。在蜂蜜样品中添加雌激素,采用单因素优化法对影响萃取效果的重要因素进行优化,获得最佳条件:IL-COF-1用量为30 mg,样品流速为3 mL/min,样品溶液pH值为7,以5 mL的1%(v/v)氨水-甲醇溶液进行洗脱,流速为0.4 mL/min,萃取过程中不添加NaCl。采用高效液相色谱-三重四极杆质谱联用技术对提取物中的雌激素进行定量分析。以乙腈和5 mmol/L的乙酸铵溶液作为流动相进行梯度洗脱,经C18色谱柱分离,采用电喷雾离子源、质谱多反应监测和负离子扫描模式,实现了蜂蜜样品中5种雌激素的快速定性定量分析。在最佳条件下,方法验证结果中雌三醇、β-雌二醇和炔雌醇的线性范围为1~500 ng/g,雌二醇和己烯雌酚的线性范围为0.1~100 ng/g,相关系数(r)为0.9934~0.9972。检出限(S/N=3)为0.01~0.30 ng/g,定量限(S/N=10)为0.05~0.95 ng/g。添加50 ng/g 5种雌激素进行重复性实验,日内精密度相对标准偏差(RSD)为3.2%~6.6%,日间精密度RSD为4.2%~7.9%。基于IL-COF-1的固相萃取-液相色谱-串联质谱法具有快速准确、灵敏度高等特点,适用于蜂蜜中雌激素的分析和检测。将该方法应用于4个实际蜂蜜样品中雌激素的检测,均未检出目标物;在低中高3个水平下,5种雌激素的加标回收率为80.1%~115.2%,结果令人满意。 相似文献
8.
T. L. Lebedeva L. M. Kardivarenko V. V. Bagreev N. A. Platé 《Russian Chemical Bulletin》1993,42(9):1471-1476
The extraction of cobalt(II) from aqueous HCl by tri-n-octylamine (TOA) inn-decane is investigated by means of FT-IR spectroscopy. The sharp increase in cobalt(II) transport during its membrane extraction from a HCl solution by solutions of TOA in a narrow interval of extradant-carrier concentrations is explained by a change in the transport mechanism which seems to differ from the diffusion and relay mechanisms.Translated fromIzvestiya Akademii Nauk. Seriya Khimicheskaya, No. 9, pp. 1539–1544, September, 1993. 相似文献
9.
《Arabian Journal of Chemistry》2022,15(10):104124
In the present study, electrospun zeolitic imidazolate framework-8/poly(lactic acid) nanofibers were successfully synthesized and characterized as a potential nanosorbent for the pipette-tip micro-solid phase extraction of chlorpropham, pirimicarb, carbaryl, and methiocarb carbamate insecticides from environmental water samples. The extraction procedure was followed by gas chromatography/mass spectrometry separation and determination of the target analytes. All the effective parameters of the extraction procedure were optimized through the one variable at-a-time method. Thanks to the very simple extraction procedure as well as the application of electrospun nanofibers with high surface area, the four analytes were efficiently extracted with as lowest extraction times as practicable. Under the optimal conditions, the calibration plots of the analytes were obtained within broad linear dynamic ranges of 0.5 – 150 ng mL?1 for chlorpropham and pirimicarb plus 1.0 – 175 ng mL?1 for carbaryl and methiocarb, respectively. Besides, limits of detection as low as 0.2 and 0.15 ng mL?1 for chlorpropham and pirimicarb, respectively, as well as 0.5 ng mL?1 for carbaryl and methiocarb indicate the favorable sensitivity of the analytical procedure. The applicability of the developed method was evaluated by quantitative determination of the target analytes in four different environmental water samples. Relative recoveries higher than 88.0% shows the acceptable accuracy of the method in the quantitative determination of the four carbamate insecticides. 相似文献
10.
A needle trap device (NTD) was developed for the extraction of polycyclic aromatic hydrocarbons (PAHs) from liquid samples followed by determination by gas chromatography–mass spectrometry (GC-MS). The extraction was performed using the dynamic sampling approach, in which a liquid sample was pumped through the system. Due to the flexibility and softness of graphene, its application in NTD may be difficult. Herein, the effectiveness of reduced graphene oxide (rGO) packed in NTD in dynamic extraction of PAHs was evaluated. Several experimental parameters, such as the adsorbent mass, eluent type and its volume, as well as the sample volume were optimized to achieve satisfactory performance for dynamic extraction. Comparative studies showed that the extraction performance of rGO-NTD was better than using NTDs packed with other sorbents such as activated carbon. The recovery rate for reduced graphene oxide exceeded 92%. Comparison of dynamic and headspace sampling showed comparable results but the dynamic mode is more suitable for field measurements. The recovery rates of PAHs spiked in water samples were from 76.5 to 100.2% and the relative standard deviation values were from 2.7 to 7.5% under the optimal conditions. This work reveals the potential of NTD with a graphene-based material for sample preparation before chromatographic analysis of liquid samples. 相似文献
11.
The sorbent/eluent systems combined from three macroporous poly(styrene–divinylbenzene) (PS-DVB) monoliths and four solvents as eluents were used for the extraction of phenol, 4-chlorophenol and p-benzochinon from water samples. Monolithic in-needle extraction (MINE) devices were used in the preparation of a series of test water samples for chromatographic analysis. The extraction of phenolic compounds from water samples was carried out by pumping liquid samples through the MINE device. Solubility parameter concept was applied for estimation of effectiveness of MINE. Solubility parameters for (PS-DVB) monoliths were determined according to Small, considering different molar fraction of the monomers used for synthesis. Effectiveness of these systems was estimated according to difference of solubility parameter value in analyte/sorbent, sorbent/eluent, analyte/eluent pairs. The procedure enabling easy prediction of, e.g. the strength of the interactions between the analyte and sorbent, eluent efficiency or the extraction efficiency in MINE system was proposed. 相似文献
12.
《Journal of Coordination Chemistry》2012,65(13):2337-2348
An emulsion liquid membrane process using bis-(2-ethylhexyl) phosphoric acid (D2EHPA) to extract and separate Ni(II) and Co(II) from acidic chloride solutions is described. Liquid membrane consists of a diluent, a surfactant (Span 80), and an extractant (D2EHPA). Hydrochloric acid was used as the stripping solution. The important parameters governing the permeation of nickel and their effect on the separation process have been studied. These parameters are stirring speed, feed phase pH, surfactant concentration, extractant concentration, stripping phase concentration, phase ratio, initial concentration of metal, and treatment ratio. The optimum conditions have been determined. The separation factors of Ni(II) with respect to Co(II), based on initial feed concentration, have been experimentally determined. Furthermore, the extraction selectivity for Co(II) over Ni(II) has been improved by using D2EHPA during the initial minutes. 相似文献
13.
A polymer inclusion membrane (PIM) is reported consisting of 45% (m/m) di(2-ethylhexyl)phosphoric acid (D2EHPA) immobilized in poly(vinyl chloride) (PVC) for use as a solid phase absorbent for selectively extracting Zn(II) from aqueous solutions in the presence of Cd(II), Co(II), Cu(II), Ni(II) and Fe(II). Interference from Fe(III) in the sample is eliminated by precipitation with orthophosphate prior to the extraction of Zn(II). Studies using a dual compartment transport cell have shown that the Zn(II) flux (2.58 × 10−6 mol m−2 s−1) is comparable to that observed for supported liquid membranes. The stoichiometry of the extracted complex is shown to be ZnR2·HR, where R is the D2EHPA anion. 相似文献
14.
Eugenie Sin Sing Tan Yu Bin Ho Mohamad Pauzi Zakaria Puziah Abdul Latif Nazamid Saari 《International journal of environmental analytical chemistry》2015,95(9):816-832
This study features the simultaneous extraction and quantification of 18 pharmaceuticals and personal care products (PPCPs). This is a pioneering method for the quantification of acetaminophen, sulfamethoxazole, diclofenac, atenolol, metoprolol, diethyltoluamide and oxybenzone in atmospheric pressure chemical ionisation mode. The method was validated for high repeatability and reproducibility with relative standard deviations less than 10%. Instrument quantification limits for PPCPs were within the range of 0.05–1.0 µg L?1, and the method quantification limits (MQLs) for ultrapure water were within the range of 0.3–15 ng L?1. All samples were extracted using Oasis© hydrophilic–lipophilic balanced cartridges with optimised sample size and extraction conditions. Good accuracy was demonstrated, with solid-phase extraction recoveries above 80% for most PPCPs. In environmental matrices, the MQLs for river water, sewage treatment plant (STP) effluent and STP influent were 4–25, 10–153 and 38–386.5, respectively. The method was successfully applied to investigate occurrences of persistent PPCPs in Malaysian river and sewage samples. 相似文献
15.
16.
In this paper, ultrasonic-assisted extraction of 3-chloropropane-1,2-diol and its esters from edible oils was studied with isotope dilution GC-MS. Effects of several experimental parameters, such as types and concentrations of extracting solvent, ratios of liquid to material, extraction temperature, time of ultrasonic treatment on the extraction efficiency of 3-chloropropane-1,2-diol and its esters from edible oils and sample preparation for calibration were compared and optimized. The optimal extraction conditions were suggested as 66 mg oil sample in mixture of 0.5 mL MTBE/ethyl acetate (20% v/v) and 0.5 mL of sulfuric acid/n-propanol (0.3% v/v), being extracted for 30 min at 45°C under ultrasonic irradiation. Good linearity was gained in the range of 0.020-5.000 μg/g with the limit of detection (LOD) of 0.006 μg/g (S/N = 3) and the limit of quantification (LOQ) of 0.020 μg/g (S/N = 10). The recoveries at five spiked concentrations were ranged from 91.9 to 109.3% with RSD less than 9.4%. The method was successfully applied to the determination of 3-chloropropane-1,2-diol and its esters amounts in rapeseed, sesame, peanut, camellia, and soybean oils. 相似文献
17.
Manuela Leticia Kim 《Talanta》2009,79(3):940-930
In this work, a non-chromatographic procedure for the on-line determination of ultratraces of V(V) and V(IV) is presented. The method involves a solid phase extraction-flow injection system coupled to electrothermal atomic absorption spectrometry (SPE-FI-ETAAS). The system holds two microcolumns (MC) set in parallel and filled with lab-made mesoporous silica functionalized with 3-aminopropyltriethoxy silane (APS) and mesoporous silica MCM-41, respectively. The pre-concentration of V(V) is performed by sorption onto the first MC (C1) filled with APS at pH 3, whilst that of V(IV) is performed by sorption onto the second column (C2) filled with mesoporous silica MCM-41 at pH 5. Aqueous samples containing both analytes are loaded and, after pre-concentration (pre-concentration factor PCF = 10, sorption flow rate = 1 mL min−1, sorption time = 10 min), they are eluted in separate vessels with hydroxylammonium chloride (HC) 0.1 mol L−1 in HCl 0.5 mol L−1 (elution volume = 1 mL, elution flow rate = 0.5 mL min−1). Afterwards, both analytes are determined through ETAAS with graphite furnace. Under optimized conditions, the main analytical figures of merit for V(V) and V(IV) are, respectively: detection limits (3 s): 0.5 and 0.6 μg L−1, linear range: 2-100 μg L−1 (both analytes), sensitivity: 0.015 and 0.013 μg−1 L and sample throughput: 6 h−1 (both analytes). Recoveries of both species were assayed in different water samples. Validation was performed through certified reference materials for ultratraces of total vanadium in river water. 相似文献
18.
Tatjana M. Trtić‐Petrović Ksenija R. Kumrić Jelena S. Đorđević Goran T. Vladisavljević 《Journal of separation science》2010,33(13):2002-2009
Transport behaviour of Lu(III) across a polypropylene hollow fibre‐supported liquid membrane containing di(2‐ethylhexyl)phosphoric acid (DEHPA) in dihexyl ether as a carrier has been studied. The donor phase was LuCl3 in the buffer solution consisting of 0.2 M sodium acetate at pH 2.5–5.0. A miniaturised system with a single hollow fibre has been operated in a batch mode. The concentration of Lu(III) was determined by indirect voltammetric method using Zn–EDTA complex. The effect of pH and volume of the donor phase, DEHPA concentration in the organic (liquid membrane) phase, the time of extraction and the content of the acceptor phase on the Lu(III) extraction and stripping behaviour was investigated. The results were discussed in terms of the pertraction and removal efficiency, the memory effect and the mean flux of Lu(III). The optimal conditions for the removal of 177Lu(III) from labelled 177Lu‐radiopharmaceuticals were discussed and identified. The removal efficiency of Lu(III) greater than 99% was achieved at pH of the donor phase between 3.5 and 5.0 using DEHPA concentration in the organic phase of 0.47 M and the ratio of the donor to the acceptor phase of 182. 相似文献
19.
Chuixiu Huang Knut Fredrik Seip Astrid Gjelstad Stig Pedersen-Bjergaard 《Analytica chimica acta》2016
Electromembrane extraction (EME) of polar basic drugs from human plasma was investigated for the first time using pure bis(2-ethylhexyl) phosphite (DEHPi) as the supported liquid membrane (SLM). The polar basic drugs metaraminol, benzamidine, sotalol, phenylpropanolamine, ephedrine, and trimethoprim were selected as model analytes, and were extracted from 300 μL of human plasma, through 10 μL of DEHPi as SLM, and into 100 μL of 10 mM formic acid as acceptor solution. The extraction potential across the SLM was 100 V, and extractions were performed for 20 min. After EME, the acceptor solutions were analyzed by high-performance liquid chromatography-ultraviolet detection (HPLC-UV). In contrast to other SLMs reported for polar basic drugs in the literature, the SLM of DEHPi was highly stable in contact with plasma, and the system-current across the SLM was easily kept below 50 μA. Thus, electrolysis in the sample and acceptor solution was kept at an acceptable level with no detrimental consequences. For the polar model analytes, representing a log P range from −0.40 to 1.32, recoveries in the range 25–91% were obtained from human plasma. Strong hydrogen bonding and dipole interactions were probably responsible for efficient transfer of the model analytes into the SLM, and this is the first report on efficient EME of highly polar analytes without using any ionic carrier in the SLM. 相似文献
20.
Qihui Wang Zheng Hu Dandan Li Zhifeng Tu 《International journal of environmental analytical chemistry》2013,93(11):1289-1301
A chelating matrix prepared by immobilising folic acid on silica gel-bound amine phase was used as a new solid-phase extractant. This sorbent has been developed only for preconcentration of trace Pb(II) prior to determination by inductively coupled plasma atomic emission spectrometry (ICP-AES). Experimental conditions were investigated by batch and column procedures. The optimum pH value for the separation of Pb(II) on the new sorbent was 4.0. The adsorbed Pb(II) was quantitatively eluted by 2.0?cm3 of 0.5?mol?dm?3 of HCl. Common coexisting ions did not interfere with the separation and determination of Pb(II). The maximum static adsorption capacity of the sorbent under optimum conditions was found to be 69.23?mg?g?1 for Pb(II). The detection limit of the method defined by International Union of Pure and Applied Chemistry was 0.28?ng?cm?3. The relative standard deviation (RSD) of the method was lower than 2.0% (n?=?8). The developed method has been validated by analysing certified reference materials and successfully applied to the determination of Pb(II) in water samples with satisfactory results. 相似文献