首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 62 毫秒
1.
A simple and very sensitive method has been developed for the determination of ascorbic acid based on the oxidation of ascorbic acid to dehydroascorbic acid by iron(III), followed by a complexation of iron(II) with 2-(5-bromo-2-pyridylazo)-5-diethylaminophenol(Br-PADAP). The iron(II) complex is formed immediately, with absorption maxima at 560 and 748 nm and a molar absorptivity of 1.31 × 105 l mole–1cm–1 and 5.69 × 104 l mole–1cm–1, respectively. The ascorbic acid determination is possible with a linear range up to 2.4 μg ml–1, a calibration sensitivity of 0.744 ml μg–1 at 560 nm and 0.323 ml μg–1 at 748 nm, and a detection limit of 15 ng ml–1 and 44 ng ml–1, respectively. The procedure was used for the ascorbic acid determination in several fruit juices and pharmaceutical formulations. The results demonstrated a good precision (R.S.D. < 1%) and are in agreement with those obtained with others methods. The Br-PADAP method proposed is six times more sensitive than the method using the iron(II)-1,10-phenanthroline system. Received: 7 May 1996 / Revised: 1 July 1996 / Accepted: 8 August 1996  相似文献   

2.
A simple and very sensitive method has been developed for the determination of ascorbic acid based on the oxidation of ascorbic acid to dehydroascorbic acid by iron(III), followed by a complexation of iron(II) with 2-(5-bromo-2-pyridylazo)-5-diethylaminophenol(Br-PADAP). The iron(II) complex is formed immediately, with absorption maxima at 560 and 748 nm and a molar absorptivity of 1.31 × 105 l mole–1cm–1 and 5.69 × 104 l mole–1cm–1, respectively. The ascorbic acid determination is possible with a linear range up to 2.4 μg ml–1, a calibration sensitivity of 0.744 ml μg–1 at 560 nm and 0.323 ml μg–1 at 748 nm, and a detection limit of 15 ng ml–1 and 44 ng ml–1, respectively. The procedure was used for the ascorbic acid determination in several fruit juices and pharmaceutical formulations. The results demonstrated a good precision (R.S.D. < 1%) and are in agreement with those obtained with others methods. The Br-PADAP method proposed is six times more sensitive than the method using the iron(II)-1,10-phenanthroline system. Received: 7 May 1996 / Revised: 1 July 1996 / Accepted: 8 August 1996  相似文献   

3.
The generation of volatile species of silicon as a means to introduce silicon into an inductively coupled plasma has been studied. It is based on the reaction between silicon and fluoride ions in sulfuric acid media and it was carried out using different flow injection mountings. The first mounting works with an injection of 100 μL concentrated sulfuric acid and 150 μL silicon standard solution in a continuous 0.05 mol L–1 NaF solution flow. The method shows a linear response between the intensity of emission at 251.611 nm line and the silicon concentration from 0.1 to 200 μg mL–1, with a reproducibility of 2% and a detection limit of 0.004 μg mL–1. The second mounting produces the volatile species by the reaction between two opposed aerosol flows in a home-made nebulization chamber. This chamber has a Cross-Flow and a Meinhard nebulizer at either end. A linear response ranging from 0.1 to 1000 μg mL–1 of silicon solution is obtained and the reproducibility rises to 8%.The detection limit reached is 0.02 μg mL–1. The silicon content in real water samples was determined by applying both the above-mentioned methods and a third method for reference. Received: 6 November 1996 / Revised: 19 December 1996 / Accepted: 3 January 1997  相似文献   

4.
Summary A method is proposed for the determination of carbetamide in water below European Union guidelines (detection limit,DL, below 0.1 μgL−1). Micro liquid-liquid extraction with dichloromethane affords carbetamide which is converted to aniline by hydrolysis. Identification and quantification of aniline was performed by GC-MS. The retention time was 4.24 min. Quantification was achieved by single-ion monitoring (SIM) atm/z 66 and 93. Clean-up is not necessary before SIM. Deuterated anthracene (2H10-anthracene) was used as internal standard. The method was used to determine carbetamide in different types of water sample spiked at very low concentration levels (0.13–10.00 μgL−1). TheDL was 0.04 μgL−1. The effect of the presence of other carbamates was also studied.  相似文献   

5.
A spectrophotometric method for the selective determination of antimony (III) and (V) in antileishmanial drugs is described. The procedure is based on the reaction of Sb(III) with bromopyrogallol red (BPR) in neutral solution. As a consequence of the Sb-BPR complex formed, the absorbance of BPR, at 560 nm, decreases proportionally to the amount of Sb(III) in the analyte solution. The calculated apparent molar absorptivity and determination limits are 3.67 × 104 L · cm–1 · mol–1 and 1.65 × 10–6 mol/L, respectively. Sb(V) is determined after reduction to Sb(III) by iodide. The Sb(V) content determined in ten samples of Glucantime varied from 75.40 ± 0.97 to 94.47 ± 1.0 mg/mL. Sb(III) was detected in all samples analyzed, and mean values ranged from 5.19 ± 0.16 to 10.52 ± 0.15 mg/mL. The method is suitable for the routine quality control of pharmaceutical formulations. Received: 26 July 1996 / Revised: 17 October 1996 / Accepted: 11 December 1996  相似文献   

6.
 A column preconcentration method has been established for the spectrophotometric determination of traces of nitrite using diazotization and coupling on an naphthalene-tetradecyldimethylbenzylammonium (TDBA)-iodide (I) adsorbent. Nitrite ion reacts with sulfanilic acid (SA) in the pH range 1.8–3.0 for the SA-1-naphthol system and in the pH range 2.3–3.2 for the SA-1-naphthylamine-4-sulfonate system (SA-NAS system) in hydrochloric acid medium to form water-soluble colourless diazonium cations. These cations were coupled with 1-naphthol in the pH range 1.6–4.6 and with NAS in the pH range 2.6–5.0 to be retained on naphthalene-TDBA-I packed in a column. The solid mass was dissolved from the column with 5 mL of dimethylformamide (DMF) and the absorbance measured at 418 nm for the SA-1-naphthol system and at 485 nm for the SA-NAS system. The calibration curve was linear over the concentration range 0.02–0.87 mg/L for SA-1-naphthol and 0.02–0.80 mg/L in the sample for SA-NAS. The molar absorptivity was calculated to be 1.70×104 L mol-1 cm-1 for SA-1-naphthol and 1.66×104 L mol-1 cm-1 for SA-NAS. The detection limits were found to be 0.014 and 0.016 mg/L for SA-1-naphthol and SA-NAS, respectively. The preconcentration factors were 8 and 6 for SA-1-naphthol and SA-NAS, respectively. Replicate determinations of seven sample solutions containing 6.6 μg of nitrite for SA-1-naphthol and 5.3 μg of nitrite for SA-NAS gave mean absorbances of 0.486 and 0.382 with relative standard deviations of 0.49 and 0.58%, respectively. Interferences due to various foreign ions have been studied and the method has been applied to the determination of 27–65 μg/L levels of nitrite in natural waters. The recovery and relative standard deviation for water samples were 98–102% and 0.49–0.58% for both systems. Received: 1 December 1995/Revised: 22 April 1996/Accepted: 22 April 1996  相似文献   

7.
A spectrophotometric determination of trimethoprim is described based on the reaction of its amine group with persulfate which acts as a strong oxidizing agent in alkaline media. The reaction produces a stable yellow colored compound after heating in a boiling water bath for 30 min. At λmax 355 nm, Beer’s law is obeyed in the concentration range 10–60 μg ml–1 with a molar absorptivity of 2.7 × 103 l mol–1cm–1. The method is applied to formulations with sulfamethoxazole. Received: 30 July 1996 / Revised: 16 October 1996 / Accepted: 22 October 1996  相似文献   

8.
A reliable and highly sensitive method for the determination of hesperidin is described. It involves the formation of a highly fluorescent complex between hesperidin and aluminium (III) in a micellar medium. There is a linear relationship between fluorescence intensity (λem = 496 nm, λex = 391 nm) and hesperidin concentration over the range 5 × 10–7– 2 × 10–5 mol L–1. The detection limit is 79 μg L–1. The method can easily be adapted to a flow system using a three-channel manifold, the peak height being proportional to the hesperidin concentration over the range 1 × 10–6– 1 × 10–4 mol L–1. Manual and flow-injection procedures have been successfully applied to the determination of hesperidin in orange peel and orange juice. Received: 21 October 1998 / Revised: 16 December 1998 / Accepted: 25 December 1998  相似文献   

9.
A flow injection method for the sequential determination of iron(II) and iron(III) was developed. It is based on the differential reaction kinetics of iron(II) and iron(III) with Tiron in a double-injection FI system. The proposed method employs the accelerating action of copper(II) for the oxidation of iron(II) in the presence of Tiron. A linear calibration graph is obtained for iron (II) and iron(III) in the concentration range 1.8 × 10–5– 1.8 × 10–4 mol/L; the throughput of samples is 30 injections/h. Received: 22 October 1996 / Revised: 4 December 1996 / Accepted: 10 December 1996  相似文献   

10.
Summary A quantitative GC method has been developed which allows determination of mono and disaccharides in enteral formulations. The method is based on the isolation of the mono and disaccharide fraction on a charcoal-celite column and conversion to trimethylsilylated oximes (TMS-oximes). The repeatability of the complete method and recovery were acceptable. In the five commercial samples assayed, maltose was the main sugar (5.24–8.85 gL−1) followed by glucose (1.06–2.41 gL−1) and lactose (0–1.17 gL−1) Low levels of fructose (0–0.18 gL−1) and sucrose (0–0.07 gL−1) were observed and galactose was detected in two of the samples. The presence of maltulose is reported in enteral formulations for the first time. Maltulose formed from maltose during processing, was present in variable amounts (0.12–1.07 gL−1) and could be a useful indicator for enteral formulation classification.  相似文献   

11.
 A sensitive and selective flotation procedure for the separation of microamounts of Co(II), Ni(II) and Cu(II) separately or in admixture is described. The maximum separation rate (∼1) for 0.1 mmol/L of each analyte is achieved using 1 mmol/L of both oleic acid (HOL) surfactant and 4-phenylthiosemicarbazide (HPTS) as a collector in the pH range 6–7. A method for the simultaneous separation and microdetermination of the analytes is elaborated, based on adding excess HPTS and floating the species with HOL at pH ∼6. The filtrate (which is clear brownish-yellow) obtained from the scum is used for the spectrophotometric determination of Co(II) at 350 nm. The formation constants of 1:1 and 1:2 [Co(II):HPTS] species are 6.9×105 and 1.22×1010 L mol-1, respectively. Beer’s law is obeyed up to 9 μg/mL of Co(II) with a molar absorptivity of 1.15×104 L mol-1 cm-1. The precipitate in the scum layer is quantitatively collected, dissolved in aqua regia and aspirated directly into the flame for the (AAS) determination of Ni and Cu. The procedure is successfully applied to some natural water samples. A mechanism for the separation of the analytes is proposed. Received: 23 January 1996/Revised: 1 April 1996/Accepted: 9 April 1996  相似文献   

12.
A new high-performance liquid chromatography assay was developed for the determination of minocycline in plasma and brain. A solid–liquid extraction procedure was coupled with a reversed-phase HPLC system. The system requires a mobile phase consisting of acetonitrile:water:perchloric acid (26:74:0.25, v/v/v) adjusted to pH 2.5 with 5 M sodium hydroxide for elution through a RP8 column (250 × 3.0 mm, i.d.) with UV detection set at 350 nm. The method proved to be accurate, precise (RSD < 20%) and linear between 0.15–20 μg mL−1 in plasma and 1–20 μg mg−1 in brain. The method was successfully applied to a blood-brain barrier minocycline transport study.  相似文献   

13.
A new procedure for the field characterization of the available amount of molybdenum in soil extract is described. It is based on the preconcentration of the Mo(V)-SCN complex into toluene solution of N-octylacetamide (OAA) and subsequent heating of the extract for ≈ 10 min at 60° C over a water bath. The molar absorptivity of the complex is (3.50) × 104 1 mole–1 cm–1 at λmax 470 nm. The detection limit of the method is 4 ppb Mo. It provides a significantly increased tolerance limit for iron (up to 1000 ppm) and is applicable to the field characterization of Mo in soil extracts. Received: 29 May 1996 / Revised: 17 July 1996 / Accepted: 19 July 1996  相似文献   

14.
A new simple, rapid and sensitive spectrophotometric flow injection method for the determination of trace iodide is described based on an ion associate of iodate (IO3 ) with 2- (3,5-dibromo-2-pyridylazo)-5-diethylamino-phenol (3,5-Br2-PADAP) and thiocyanate (SCN). In a strongly acidic medium, this unstable violet product was formed with an absorption maximum at 605 nm. Flow injection is an ideal method to reproducibly monitor the transient signal. Various parameters were optimized using the Super Modified Controlled Weighted Centroid Simplex Method (SMCWC). Under the optimum experimental conditions, iodide could be determined in the range of 1.00 × 10–6 and 2.4 × 10–5 mol l–1. The correlation coefficient of the calibration curve is 0.9991. With a sampling frequency of 80 h–1, the detection limit for iodide is 5.0 × 10–7 mol l–1. The proposed method has been applied to the determination of trace iodide after oxidizing I in table salt or laver to IO3 . In addition, the mechanisms of the ion association reaction was studied. Received: 15 August 1996 / Revised: 10 October 1996 / Accepted: 16 October 1996  相似文献   

15.
An 1-(pyridylazo)-2-naphthol modified glassy carbon electrode has been investigated as sensor for the measurement of trace levels of Cd2+. Cd2+ is deposited on the surface of a PAN modified glassy carbon electrode at –1.10 V (vs. SCE) via forming Cd2+–PAN and subsequent reduction at the electrode. In the following step, Cd-PAN is oxidized, and voltammograms are recorded by scanning the potential in a positive direction. Calibration plots were found to be linear in the range 2 × 10–8 mol/L to 8 × 10–7 mol/L. The detection limit was 5 × 10–10 mol/L, and the coefficient of variation, determined on one single electrode at a concentration of 5 × 10–7 mol/L, was calculated to be 3.2% (n = 5). Using this new kind of modified electrode, trace levels of Cd(II) in water samples were determined; the average recovery was calculated to be 98.78%. Received: 17 August 2000 / Revised: 19 December 2000 / Accepted: 27 December 2000  相似文献   

16.
Three different methods for sampling and determination of nitrogen dioxide in urban air are compared: an NO/NOx-monitor and an active (pumped) and a passive sampling method. For the latter two methods, sodium iodide is used as absorbent. For weekly averages the results from the passive sampler are within 10–20% of the results for the two other methods in the concentration range 15–30 μg NO2/m3. The detection limit for the passive sampler is 1 μg NO2/m3 (7 days), the precision is 5% and the accuracy is estimated to 20%. The active iodide method agrees very well with the NO/NOx-monitor. Compared on 24 h basis for a period of 3 months, covering a concentration range of 5–45 μg NO2/m3, the deviation between the two methods is within 5%, and the absorption capacity of the iodide reagent is excellent as the breakthrough is below 1%. Received: 3 December 1996 / Revised: 11 March 1997 / Accepted: 15 March 1997  相似文献   

17.
A voltammetric stripping procedure is described for the determination of arsenic(V) in a mannitol-sulphuric acid medium. The arsenic is coprecipitated with copper and selenium and reduced to arsine at the hanging mercury drop electrode. Using an accumulation time of 240 s, the detection limit is 0.52 μg L–1, the determination limit is 0.9 μg L–1. The method has been applied to the determination of arsenic in water samples. By varying the composition of the supporting electrolyte it is possible to differentiate between arsenic(III) and arsenic(V). As both oxidation states have different toxicological characteristics, the ability to discriminate between both is an distinct advantage of the proposed method. Received: 25 October 1996 / Revised: 7 February 1997 / Accepted: 12 February 1997  相似文献   

18.
A minicolumn packed with poly(aminophosphonic acid) chelating resin incorporated in an on-line preconcentration system for flame atomic-absorption spectrometry was used to determine ultratrace amounts of lead in mussel samples at μg L–1 level. The preconcentrated lead was eluted with hydrochloric acid and injected directly into the nebulizer for atomization in an air-acetylene flame for measurement. The performance characteristics of the determination of lead were: preconcentration factor 26.8 for 1 min preconcentration time, detection limit (3σ) in the sample digest was 0.25 μg g–1 (dry weight) for a sample volume of 3.5 mL and 0.2 g sample (preconcentration time 1 min), precision (RSD) 2.3% for 25 μg L–1 and 2.0% for 50 μg L–1. The sampling frequency was 45 h–1. The method was highly tolerant of interferences, and the results obtained for the determination of lead in a reference material testify to the applicability of the proposed procedure to the determination of lead at ultratrace level in biological materials such as mussel samples. Received: 1 November 2000 / Revised: 8 January 2001/ Accepted: 11 January 2001  相似文献   

19.
A simple reversed-phase high-performance liquid chromatographic (HPLC) method has been developed for the simultaneous determination of the antiepileptic drugs (AEDs) zonisamide (ZNS), primidone (PRI), lamotrigine (LTG), phenobarbital (PB), phenytoin (PHT), oxcarbazepine (OXC), and carbamazepine (CBZ) and two of their active metabolites, monohydroxycarbamazepine (MHD) and carbamazepine 10,11-epoxide (CBZE) in human plasma. Plasma (100 μL) was pretreated by deproteinization with 300 μL methanol containing 20 μg mL−1 propranolol hydrochloride as internal standard. HPLC was performed on a C8 column (4.6 mm × 250 mm; particle size 5 μm) with methanol–acetonitrile–0.1% trifluoroacetic acid, 235:120:645 (v/v), as mobile phase at a flow rate of 1.5 mL min−1. ZNS, OXC, and CBZ were monitored by UV detection at 235 nm, and PRI, LTG, MHD, PB, PHT, and CBZE by UV detection at 215 nm. Relationships between response and concentration were linear over the concentration ranges 1–80 μg mL−1 for ZNS, 5–50 μg mL−1 for PRI, 1–25 μg mL−1 for LTG, 1–50 μg mL−1 for MHD, 5–100 μg mL−1 for PB, 1–10 μg mL−1 for CBZE, 0.5–25 μg mL−1 for OXC, 1–50 μg mL−1 for PHT, and 1–25 μg mL−1 for CBZ. Intra-day and inter-day reproducibility were adequate (coefficients of variation were ≤11.6%) and absolute recovery ranged from 95.2 ± 6.13 to 107.7 ± 7.76% for all the analytes; for the IS recovery was 98.69 ± 1.12%. The method was proved to be accurate, reproducible, convenient, and suitable for therapeutic monitoring of the nine analytes.  相似文献   

20.
The applicability of various potential-sensitive dyes (PSD) for optical sensing of anions is reported. Specifically, nitrate-responsive polymer membranes have been developed which are composed of a plasticized polymer, an anion exchange catalyst, and a fluorescent dye. On exposure to nitrate, the fluorescence intensity of such membranes increases, while the wavelengths of the excitation and emission maxima remain virtually unchanged. The membranes typically are 2–4 μm thick and exhibit highest sensitivity to nitrate in the 2 to 200 mgl–1 range. Signal changes on exposure to 100 mmol/l nitrate can be as high as +300%. The detection limit is 0.2 mgl–1. The cationic PSD octadecyl acridine organe was tested in combination with a tin-organic and an indium-organic anion carrier rather than with tridodecylmethylammonium chloride, but both carriers were found to display no improved selectivity. Received: 2 December 1995 / Revised: 28 March 1996 / Accepted: 5 April 1996  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号