首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
Near-field scanning optical microscopy (NSOM) has been used to investigate the photophysical characteristics of first- to fourth-generation (G1 to G4) light-harvesting dendrimer thin films containing coumarin-343 and coumarin-2 as the core and peripheral chromophores, respectively. Thin film photoluminescence (PL) spectra exhibit a significant red shift in the lower generations (G1, G2, and G3) as compared to their respective solution PL spectra, implying the formation of excimers. Spatially resolved PL NSOM images exhibit pronounced nanoscopic domains in G1, which become more homogeneous in higher generations due to site-isolation of the core chromophore. G4 exhibits complete site-isolation for these light-harvesting dendrimer films.  相似文献   

2.
Instrumentation of a high-resolution optical scanning fluorescence microscope is presented. This instrument provides a fluorescent image of the structural surface of various kinds of thin membrane samples with high resolution on the molecular scale. For this instrument, a new excitation optical tip and a three-dimensional scanning unit have been designed. The optical tip consists of a sharpened optical fibre covered with evaporated aluminium in vacuo, on which the top has a pinhole. The optical tip is mounted in the centre of a crosslinked piezoelectric scanning head. On thez-axis, a piezoelectric positioner is equipped with a differential micrometer mechanism. All operations are controlled with a micro-computer system.The scanning area in this instrument is 4000*4000 nm2 for measurements of biological specimens. Several optical scanning microscopic images as well as the STM image are presented.  相似文献   

3.
Physicochemical properties of ultrafiltration membranes were studied by scanning electron microscopy. The membrane elemental composition (carbon, oxygen, and sulfur) was determined by energy dispersion analysis. The elements were shown to be homogeneously distributed along the membrane. A homogeneous pore distribution on the membrane surface was found after covering it with a thin gold layer. The pore sizes are 50 nm. The topographic analysis of the permeate-side of the membrane indicated its anisotropy.  相似文献   

4.
A non‐optical force sensor that allows operation both in lateral (shear) and in vertical (tapping) force detection modes has been introduced for dynamic tip–sample distance regulation in scanning near‐field optical microscopy (SNOM) of biological samples. The sensor is based on a rectangular bimorph cantilever consisting of two thin piezoceramic layers bonded to a brass centre shim. One of the piezo layers serves as the probe dither and another as the responder of the sensed forces. The sensor is driven with a home‐made Q‐control electronics so that its sensitivity and bandwidth can be adjusted. The dynamics, characteristics and design considerations of the sensor are theoretically and experimentally discussed. Driving the bimorph cantilever at its eigenfrequency with appropriate force feedback allows one to obtain a quality factor (Q‐factor) up to 103 in water, suitable for different sample softness and imaging environments. The high sensitivity of the sensor is demonstrated both by shear force and by tapping mode imaging of soft biological samples in their natural state. Near‐field optical resolution of better than 100 nm on red blood cells in water has been obtained. The experimental results suggest that this SNOM sensor would be a promising set‐up for biological applications. Copyright © 2007 John Wiley & Sons, Ltd.  相似文献   

5.
Pristine and Annealed 170 nm films of the stiff-chain polyfluorene, bearing two hexyl ( 1 ) or dodecyl ( 2 ) groups at the 9 position were studied using Near-field Scanning Optical Microscopy (NSOM). NSOM images reveal two distinct types of nanoscale film morphology: clusters and long-range order (LRO). Dual polarization and dual wavelength fluorescence collection schemes are combined with the use of simple image math provide both qualitative and quantitative characterization. In pristine films, shorter alkyl substituents ( 1 ) reduce the solubility of the polyfluorene in the spinning solution used for spin-coating films which leads to the formation of 50-150 nm clusters which are not present in films made from 2 . Clusters can be removed by annealing as a function of time. Polarization shows the clusters are amorphous with fluorescence from both intra and inter-polymer species. The second variety of nanoscale ordering, LRO, is characterized by regions of polarized emission in the polymer films. This polarization can be quantified with an anisotropy value and is barely present in pristine films of 1 but increases dramatically upon annealing to induce a liquid crystalline phase transition. Pristine films of 2 have larger anisotropy values than pristine films of 1 , due to longer alkyl-substituent-induced ordering during the spin-coating procedure, but films of 2 have only a slight increase in their anisotropy value upon annealing. Both intra and inter-polymer emitting species are distributed homogeneously throughout both pristine and annealed films within the resolution of our microscope (40-70 nm).  相似文献   

6.
In this work we have studied the optical activity of chiral crystal surfaces with polarized near-field scanning optical microscopy (NSOM); our studies clearly demonstrated that polarized NSOM can be utilized to determine chirality at crystal surfaces.  相似文献   

7.
8.
Single-cell analysis is important for understanding fundamental biological processes and mechanisms. Scanning electrochemical microscopy and scanning ion conductance microscopy as two kinds of scanning probe microscopy, with high temporal and spatial resolutions as well as in situ and noninvasive characterization capabilities, emerge as strong tools for single-cell analysis. In this review, we introduce the latest advances of scanning electrochemical microscopy and scanning ion conductance microscopy for single-cell analysis, including characterizations of cell morphology dynamics, membrane properties and mechanics, and monitoring cell surface charge, extracellular pH, and intracellular substances.  相似文献   

9.
10.
In this work, we present and discuss the use of cavity-microelectrodes (C-MEs) used as tip for the scanning electrochemical microscopy (SECM). Cavity-microelectrodes can be filled with a desired finely dispersed material thus compensating for the limited commercial availability of microwires. After discussing the possibility of filling and emptying a cavity-microelectrode with a desired tip shape, the consistency of negative and positive feedback approach curves obtained after filling a Au C-ME was verified. In addition, the tip/C-ME was tested under gas (oxygen) evolution condition, in order to demonstrate that the filling is stable in a wide range of gas fluxes thus extending the possible applications to tip generation/substrate collection mode. Finally, we introduce the use of the proposed system to quantify the rates of parallel reactions occurring at the material inserted in the tip under the tip generation/substrate collection mode.  相似文献   

11.
In recent years scanning near-field optical microscopy (SNOM) has developed into a powerful surface analytical technique for observing specimens with lateral resolution equal to or even better than 100 nm. A large number of applications, from material science to biology, have been reported. In this paper, two different kinds of near-field optical microscopy, aperture and scattering-type SNOM, are reviewed together with recent studies in surface analysis and biology. Here, near-field optical techniques are discussed in comparison with related methods, such as scanning probe and standard optical microscopy, with respect to their specific advantages and fields of application.  相似文献   

12.
We have developed a wet-chemistry procedure to attach a 10-40 nm colloidal gold nanoparticle to the top of a scanning probe microscopy (SPM) probe tip, making experiments of single nanoparticle interaction possible. This procedure of particle attachment is flexible and can be modified to attach nanoparticles of different kinds and sizes. The single-nanoparticle-terminated tips also have potential in various other applications, such as probes of enhanced sensitivity for optical and magnetic modes SPM.  相似文献   

13.
This review highlights the use and great potential of liquid metals as exotic and powerful solvents (i.e. fluxes) for the synthesis of intermetallic phases. The results presented demonstrate that considerable advances in the discovery of novel and complex phases are achievable utilizing molten metals as solvents. A wide cross-section of examples of flux-grown intermetallic phases and related solids are discussed and a brief history of the origins of flux chemistry is given. The most commonly used metal fluxes are surveyed and where possible, the underlying principal reasons that make the flux reaction work are discussed.  相似文献   

14.
Different gold surfaces modified by carbon-spray have been investigated by scanning electron microscopy (SEM) and scanning electrochemical microscopy (SECM). A transformation of the SECM image to a distance-location profile is proposed which assists the correlation of both images. The structures found in the transformed SECM images of carbon-spray layers on gold substrates can be explained by the topographic features visible in the SEM pictures. Tempering the carbon spray results in an increased density of electrochemically reactive carbon particles which could be confirmed by cyclic voltammetric investigations. Gold minigrids modified with carbon spray expose some areas of especially large currents which could not be predicted from their SEM images. This effect may result from particles located at the edge of a wire intersection having relatively large active surfaces per particle. They contribute significantly to the total current of the minigrid.  相似文献   

15.
Tip-enhanced optical spectroscopy is an approach that holds a good deal of promise for the nanoscale characterisation of matter. Tip-enhanced Raman spectroscopy (TERS) has been demonstrated on a variety of samples: inorganic, organic and biological. Imaging using TERS has been shown for carbon nanotubes due to their high scattering efficiency. There are a number of compelling motivations to consider alternative approaches for biological samples; most importantly, the potential for heat damage of biomolecules and long acquisition times. These issues may be addressed through the development of tip-enhanced coherent anti-Stokes Raman scattering microscopy.  相似文献   

16.
We developed a high-resolution scanning electrochemical microscope (SECM) for the characterization of various biological materials. Electrode probes were fabricated by Ti/Pt sputtering followed by parylene C-vapor deposition polymerization on the pulled optical fiber or glass capillary. The effective electrode radius estimated from the cyclic voltammogram of ferrocyanide was found to be 35 nm. The optical aperture size was less than 170 nm, which was confirmed from the cross section of the near-field scanning optical microscope (NSOM) image of the quantum dot (QD) particles with diameters in the range of 10-15 nm. The feedback mechanism controlling the probe-sample distance was improved by vertically moving the probe by 0.1-3 microm to reduce the damage to the samples. This feedback mode, defined as "standing approach (STA) mode" (Yamada, H.; Fukumoto, H.; Yokoyama, T.; Koike, T. Anal. Chem. 2005, 77, 1785-1790), has allowed the simultaneous electrochemical and topographic imaging of the axons and cell body of a single PC12 cell under physiological conditions for the first time. STA-mode feedback imaging functions better than tip-sample regulation by the conventionally available AFM. For example, polystyrene beads (diameter approximately 6 microm) was imaged using the STA-mode SECM, whereas imaging was not possible using a conventional AFM instrument.  相似文献   

17.
We describe a method for measuring the lateral focal spot size of a multiphoton laser scanning microscope (LSM) with unprecedented accuracy. A specimen consisting of an aluminum film deposited on a glass coverslip was brought into focus in a LSM and the laser intensity was then increased enough to perform nanoablation of the metal film. This process leaves a permanent trace of the raster path usually taken by the beam during the acquisition of an optical image. A scanning electron microscope (SEM) was then used to determine the nanoablated line width to high accuracy, from which the lateral spot size and hence resolution of the LSM can be determined. To demonstrate our method, we performed analysis of a multiphoton LSM at various infrared wavelengths, and we report measurements of optical lateral spot size with an accuracy of 20 nm, limited only by the resolution of the SEM.  相似文献   

18.
Differential scanning calorimetry thermograms of five commercial categories of olive oils (extra virgin olive oil, olive oil, refined olive oil, olive-pomace oil and refined olive-pomace oil) were performed in both cooling and heating regimes. Overlapping transitions were resolved by deconvolution analysis and all thermal properties were related to major (triacylglycerols, total fatty acids) and minor (diacylglycerols, lipid oxidation products) chemical components.All oils showed two well distinguishable exothermic events upon cooling. Crystallization enthalpies were significantly lower in olive oils due to a more ordered crystal structure, which may be related to the higher triolein content. Pomace oils exhibited a significantly higher crystallization onset temperature and a larger transition range, possibly associated to the higher amount of diacylglycerols. Heating thermograms were more complex: all oils exhibited complex exo- and endothermic transitions that could differentiate samples especially with respect to the highest temperature endotherm.These preliminary results suggest that both cooling and heating thermograms obtained by means of differential scanning calorimetry may be useful for discriminating among olive oils of different commercial categories.  相似文献   

19.
Optical resolutions through self-assembled membranes were carried out by using poly(pyrrole) (PPy) doped with chiral anionic polymers such as poly(L-glutamic acid) or dextran sulfonic acid. Preferential permeations of either L- or D-Tryptophane occurred through the PPy membranes.  相似文献   

20.
Time-resolved fluorescence spectroscopy (TRFS) was applied to an aluminate glass sample doped with Eu3+ cation as a fluorescent probe of the chemical environment and local symmetry. Conventional far-field experiments revealed the presence of two different phases: an amorphous phase featured by a highly disordered environment surrounding the Eu3+ cation and a more ordered polycrystalline phase that exhibits a significant increase in the Eu3+ fluorescence decay time compared to that of the amorphous phase. Near-field fluorescence spectra and decay kinetics were recorded in the frontier region between the two phases using a home-built scanning near-field optical microscope. SNOM-TRFS experiments confirmed the presence of local heterogeneities in this part of the glass at a sub-micrometric spatial scale. Polycrystalline sites featured an important shear-force interaction with the probing fiber optic tip, a longer fluorescence decay time, and a higher Stark splitting of the 5D0 --> 7FJ (J = 1-4) electronic transitions of the Eu3+ cations.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号