共查询到20条相似文献,搜索用时 125 毫秒
1.
2.
A method combining high-performance liquid chromatography for separation of digoxin from three of its metabolites with subsequent quantitation of each compound by radioimmunoassay is described. The metabolites are shown to interfere with the radioimmunoassay procedure thus providing the need for separation prior to assay. 相似文献
3.
We describe two methods for the analysis of oligosaccharide chains in glycoproteins by high-performance liquid chromatography (HPLC) and high-performance capillary electrophoresis (HPCE).O-andN-glycosidically linked oligosaccharides released from glycoproteins can be identified as their borohydride-reduced forms by anion-exchange HPLC with pulsed amperometric detection.N-Glycosidically linked oligosaccharides can also be analyzed as 2-aminopyridine derivatives by HPCE in direct zone electrophoresis mode in an acidic phosphate buffer and zone electrophoresis mode as borate complexes in an alkaline buffer. We also present a convenient procedure for the analysis of the constituent monosaccharides of these oligosaccharides chains by HPLC based on reversed-phase partition mode as 1-phenyl-3-methyl-5-pyrazolone derivatives. 相似文献
4.
A column-switching high-performance liquid chromatography (HPLC) method is described for the simultaneous determination of loganin and sweroside, which are the active ingredients of purified herbal extract from Lonicera japonica (SKL JI), in rat plasma using column-switching and ultraviolet (UV) absorbance detection. Plasma was simply filtrated prior to injection to the HPLC system consisting of a clean-up column, a concentrating column, and an analytical column, which were connected with two six-port switching valves. Detection of loganin and sweroside was accurate and repeatable, with a limit of quantitation of 0.05 μg ml−1 in plasma. The calibration curves for both loganin and sweroside were linear over the concentration ranges of 0.05-40.0 and 0.02-40.0 μg ml−1 in rat plasma, respectively. The intra- and inter-day precision over the concentration range for loganin and sweroside were lower than 8.1 and 10.9% (relative standard deviation, R.S.D.), and accuracy was between 94.7 and 113.5 and 95.0 and 113.1%, respectively. This method has been successfully applied to determine the levels of loganin and sweroside in rat plasma samples from pharmacokinetics studies. 相似文献
5.
6.
To facilitate the determination of the fatty acid composition of tissues and the investigation of fatty acid metabolism, we developed a method for the rapid separation by high-performance liquid chromatography and quantitation (by ultraviolet light absorption) of p-bromophenyl esters of fatty acids which vary in chain length from 10 to 22 carbon atoms. The utility of the method was demonstrated by evaluating the fatty acid composition of human uterine decidua vera tissue and human endometrial stromal cells that are maintained in monolayer culture. 相似文献
7.
Improved quantitation of 13-cis- and all-trans-acitretin in human plasma by normal-phase high-performance liquid chromatography. 总被引:1,自引:0,他引:1
E Meyer W E Lambert A P De Leenheer J P Bersaques A H Kint 《Journal of chromatography. A》1991,570(1):149-156
A reliable analytical method has been developed for measurement of 13-cis- and all-trans-acitretin (Neotigason) in human plasma by normal-phase high-performance liquid chromatography, with ultraviolet detection. Human plasma was obtained after centrifugation of whole blood samples and deproteinized by ethanolic denaturation. After liquid-liquid extraction with water-n-hexane, and aliquot ws chromatographed on a silica column using isocratic elution with n-hexane-methylsalicylate-acetic acid (200:18:0.6, v/v). The wavelength was set at 360 nm, and for plasma samples a limit of quantification of 3-4 ng/ml was obtained. All manipulations were carried out under dim light conditions to prevent photoisomerization. 相似文献
8.
A comparative study of two analytical methodologies for piroxicam quantitation in plasma by off-line and on-line solid-phase extraction (SPE) and high-performance liquid chromatography (HPLC) is described. The SPE cartridges contained C8 for both extraction methods. The analytes piroxicam and tenoxican (internal standard) were separated on a C18 column with a mobile phase consisting of acetonitrile:20 mM phosphate buffer pH 3.1 (50:50, v/v) followed by UV detection at 360 nm. The validation of the methods demonstrated good recoveries (over 90%), sensitivity (limits of quantification of 0.05 microgram/ml with on-line SPE and 0.1 microgram/ml with off-line SPE, based on a 100 microliters and 200 microliters sample volume, respectively), accuracy and precision (better than 9.5%). Both methodologies have been used for bioequivalence studies. 相似文献
9.
10.
A fully validated and clinically relevant assay was developed for the assessment of nevirapine concentrations in neonate blood plasma samples. Solid-phase extraction with an acid-base wash series was used to prepare subject samples for analysis. Samples were separated by high performance liquid chromatography and detected at 280 nm on a C8 reverse-phase column in an isocratic mobile phase. The retention times of nevirapine and its internal standard were 5.0 and 6.9 min, respectively. The method was validated by assessment of accuracy and precision (statistical values <15%), specificity, and stability. The assay was linear in the range 25-10,000 ng/mL (r2 > 0.996) and the average recovery was 93% (n = 18). The lower limit of quantification (relative standard deviation <20%) was determined to be 25 ng/mL for 50 microL of plasma, allowing detection of as little as 1.25 ng of nevirapine in a sample. This value represents an increase in sensitivity of up to 30-fold over previously published methods. 相似文献
11.
12.
13.
14.
15.
W D Henner E A Furlong M D Flaherty T C Shea W P Peters 《Journal of chromatography. A》1987,416(2):426-432
16.
17.
Procedures for the micro-determination of beta-cyclodextrin (beta-CyD) in plasma were investigated by four methods using high-performance liquid chromatography (HPLC). In methods A and B, underivatized beta-CyD was detected with a refractive index detector and determined by the absolute calibration graph method. An NH2-bonded silica/acetonitrile-water system was used in A and a C18-bonded silica/methanol-water system in B. In method C, the percarbanilate of beta-CyD was separated on a C8-bonded silica column with acetonitrile-water and determined using gamma-CyD as the internal standard with a UV detector at 231 nm. In method D, the per[1-14C]acetate of beta-CyD was fractionated on a silica column with n-hexane-ethanol containing 1% of water and the radioactivity of each fraction was measured with a liquid scintillation counter. gamma-CyD was used as the internal standard. Interfering plasma proteins were removed by centrifugal ultrafiltration with an MPS-1 micro-partition system. Method B was superior to the other methods with respect to ease of sample preparation, sensitivity and time required for analysis. The cumulative amount of beta-CyD in the mesenteric vein absorbed from the rat intestinal lumen after administration of phenobarbital-beta-CyD complex in a closed loop method was determined by the use of method B. 相似文献
18.
19.
A new method for the separation and quantitative determination of certain anti-biotics of the tetracycline series in blood plasma by high-performance liquid chromatography on a column filled with Partisil PXP 5 silica gel is described.I. M. Sechenov First Moscow Medical Institute. Translated from Khimiya Prirodnykh Soedinenii, No. 3, pp. 376–379, May–June, 1981. 相似文献