首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 45 毫秒
1.
The electrochemical oxidation of homocysteine was studied at as-deposited and anodized (oxidized) boron-doped diamond (BDD) thin film electrodes with cyclic voltammetry, flow injection analysis and high-pressure liquid chromatography with amperometric detection. At anodized boron-doped diamond electrodes, highly reproducible, well-defined cyclic voltammograms for homocysteine oxidation were obtained in acidic media, while as-deposited diamond did not provide a detectable signal. In alkaline media, however, the oxidation response was obtained both at as-deposited and anodized diamond electrodes. The potential sweep rate dependence of homocysteine oxidation (peak currents for 1 mM homocysteine linearly proportional to v(1/2), within the range of 0.01 to 0.3 V s(-1)) indicates that the oxidation involves a diffusing species, with negligible adsorption on the BDD surface at this concentration. In the flow system, BDD exhibited a highly reproducible amperometric response, with a peak variation less than 2%. An extremely low detection limit (1 nM) was obtained at 1.6 V vs. Ag/AgCl. In addition, the determination of homocysteine in a standard mixture with aminothiols and disulfide compounds by means of isocratic reverse-phase HPLC with amperometric detection at diamond electrodes has been investigated. The results showed excellent separation, with a detection limit of 1 pmol and a linear range of three orders of magnitude.  相似文献   

2.
The electrochemical behavior of nitrogen bases and their derivatives is studied on electrodes modified with carbon nanotubes. On these electrodes, the strong adsorption of purines and their oxidation is observed at potentials in the vicinity of +0.8 V for guanine and +1.0 V (vs. Ag/AgCl) for guanine nucleosides/nucleotides and adenine. At more positive potentials, the high background current prevents the detection of adenine nucleotides and pyrimidines. The peculiarities of oxidation of the most easily detectable DNA components, namely, guanine and deoxyguanosinemonophosphate, on modified electrodes are elucidated and the corresponding reaction scheme is proposed. The results can be used in the development of biosensors based on electroactive properties of nucleic acids and their components.  相似文献   

3.
We have developed ultra-flat carbon film electrodes with a wide potential window and a low capacitive current by the electron cyclotron resonance (ECR) sputtering method. The film consists of sp2 and sp3 bonds (sp3/sp2 ratio = 0.702) and is sufficiently conductive for electrochemical measurements without doping. The film has average roughness of 0.7 A, which is much flatter than that of nanocrystalline diamond film. The potential limit of ECR sputtered carbon (current limit < +/-500 muA/cm2) in the positive direction is 2.0 V vs Ag/AgCl, which is slightly lower than that of boron-doped diamond (2.1 V) and much wider than that of a glassy carbon (GC) electrode (1.7 V). In contrast, a much wider potential window can be obtained in the negative direction. The capacitive current is also much lower than that of a GC electrode due to the ultra-flat surface and the low number of oxygen-containing groups at the film surface. ECR sputtered carbon film can be used to measure each base of oligonucleotides by electrochemical oxidation without any pretreatment. The ultra-flat surface and low surface oxygen concentration suppress fouling with electroactive species, such as oligonucleotides, NADH, and bisphenol A.  相似文献   

4.
The electrochemical analysis of tetracycline was investigated using nickel-implanted boron-doped diamond thin film electrode by cyclic voltammetry and amperometry with a flow injection system. Cyclic voltammetry was used to study the electrochemical oxidation of tetracycline. Comparison experiments were carried out using as-deposited boron-doped diamond thin film electrode (BDD). Nickel-implanted boron-doped diamond thin film electrode (Ni-DIA) provided well-resolved oxidation irreversible cyclic voltammograms. The current signals were higher than those obtained using the as-deposited BDD electrode. Results using nickel-implanted boron-doped diamond thin film electrode in flow injection system coupled with amperometric detection are presented. The optimum potential for tetracycline was 1.55 V versus Ag/AgCl. The linear range of 1.0 to 100 microM and the detection limit of 10 nM were obtained. In addition, the application for drug formulation was also investigated.  相似文献   

5.
《Comptes Rendus Chimie》2008,11(9):1004-1009
The paper reports on the electrocatalytic activity of boron-doped diamond (BDD) electrodes electrochemically modified with palladium (Pd) or gold nanoparticles (Au NPs) towards oxygen reduction reaction (ORR) in alkaline medium. The BDD/Pd NP interface shows a well-defined diffusion-controlled voltammetric oxygen reduction peak at −0.25 V vs. Ag/AgCl. This is more positive than the ORR peak at −0.59 V vs. Ag/AgCl observed on BDD/Au-NP composite electrodes. The ORR proceeds via a four-electron process in both cases.  相似文献   

6.
Electrochemical detection of sugar-related compounds was conducted using a boron-doped diamond (BDD) electrode as a detector for flow-injection analysis (FIA). Sugar-related compounds oxidize at high applied potentials, for which the BDD electrode is suitable for electrochemical measurements. Conditions for an FIA system with a BDD detector were optimized, and the following detection limits were achieved for sugar-related compounds: monosaccharides, 25-100 pmol; sugar alcohols, 10 pmol; and oligosaccharides, 10 pmol. The detection limit for monosaccharide D-glucose (Glu) was 105 pmol (S/N = 3). A linear range was acquired from the detection limit to 50 nmol, and the relative standard deviation was 0.65% (20 nmol, n = 6). A high-performance liquid chromatography (HPLC) column was added to the system between the sample injector and the detector and detection limits to the picomole level were achieved, which is the same for the HPLC system and the FIA system. The electrochemical oxidation reaction of Glu was examined using cyclic voltammetry with the BDD detector. The reaction proved to be irreversible, and proceeded according to the following two-step mechanism: (1) application of a high potential (2.00 V vs. Ag/AgCl) to the electrode causes water to electrolyze on the electrode surface with the simultaneous generation of a hydroxyl radical on the surface, and (2) the hydroxyl radical indirectly oxidizes Glu. Thus, Glu can be detected by an increase in the oxidation current caused by reactions with hydroxy radicals.  相似文献   

7.
《Analytical letters》2012,45(13):2581-2589
Abstract

The characteristics of the boron‐doped diamond (BDD) electrode in this work were studied by atomic force microscope (AFM), scanning electron microscopy, and Raman spectroscopy. The electro‐oxidation of formaldehyde at the BDD electrode in 0.5 M K2SO4 with different pH was studied by cyclic voltammetry and amperometry. There is no significant oxidation peak of formaldehyde in acidic solution because the oxidation of formaldehyde is at the potential range of water discharge. However, in neutral solution, there is a well‐defined oxidation peak at about +2.2 V vs. Ag/AgCl. The relation between the response current and formaldehyde concentration is linear behavior at the concentration range from 50 to 600 µM. Besides, in neutral solution, the oxidation of formaldehyde is dominated by indirect oxidation at lower formaldehyde concentration, and it is dominated by direct oxidation at higher concentration. Finally, in alkaline solution, the oxidation of formaldehyde is dominated by indirect oxidation caused by a powerful oxidant and is related to the ratio of the amounts of formaldehyde and OH molecules at the BDD electrode surface.  相似文献   

8.
This paper reports the results of an investigation into enhancement of the electrochemical oxidation of p-aminophenol (4-AP) in an aqueous solution with a boron-doped diamond (BDD) electrode, assisted by photocatalysis using a zeolite-supported TiO2 (Z-TiO2) catalyst. The BDD electrode was characterised in 0.1 M Na2SO4-supporting electrolyte and the presence of 4-AP by open-circuit potential behaviour (OCP) and cyclic voltammetry (CV). The electrode behaviour was investigated in the dark and following UV irradiation and in the absence/presence of the Z-TiO2 catalyst. The electro-oxidation process was carried out using chronoamperometry (CA) and multiple-pulsed amperometry (MPA) at the selected potential under potentiostatic conditions. The electrochemical degradation process of 4-AP on the BDD electrode was improved by the application of a pulsed potential, which allowed both in-situ electrochemical cleaning of the electrode and indirect oxidation of 4-AP by oxygen evolution. The application of photocatalysis using Z-TiO2 in the 4-AP electrochemical degradation exhibited an enhanced effect when the anodic potential was set at +1.25 V vs. Ag/AgCl in the water stability region, close to the oxygen evolution potential.  相似文献   

9.
Horseradish peroxidase (HRP) has been immobilized on the surface of functionalized nanocrystalline diamond (NCD) thin films. The structure of the modified NCD surface as well as the electrochemical behavior of the whole system was characterized by impedance spectroscopy and cyclic voltammetry. The proximity of HRP heme groups to the NCD surface allowed direct electron transfer between them, resulting in two separated one-electron-transfer peaks at 0.05 V and 0.29 V vs Ag/AgCl, corresponding to the cathodic and anodic process, respectively. The heterogeneous electron-transfer constant for both processes was calculated to be 0.066 s(-1), the charge-transfer coefficient alpha = 0.49, and the immobilized enzymatic layer about 2.10(-10) mol/cm2. The modified NCD electrode was used as a third-generation biosensor for hydrogen peroxide determination showing a linear response in the 0.1-45 mM H2O2 range, at +0.05 V vs Ag/AgCl.  相似文献   

10.
Direct redox activity of different proteins was investigated on the surface of carbon screen printed electrodes (SPE). The signal attributed to the electrochemical oxidation of amino acid residues (cysteine (Cys), tryptophan (Trp) and tyrosine (Tyr)) was registered at Emax from 0.6 to 0.7 V (vs. Ag/AgCl). Based on the difference in the redox behavior of L ‐tyrosine and 3‐nitro‐L ‐tyrosine, the selective electrochemical detection of native and nitrated albumins was demonstrated. It was shown that the electrochemical signal correlated with the surface density of electroactive amino acid residues on the protein molecule. A simple electrochemical method for the total protein analysis was proposed.  相似文献   

11.
The electrochemical oxidation of thrombin on the surface of carbon screen printed electrodes was studied. The electrochemical activity of thrombin was predicted, using bioinformation analysis, based on the data about the electrochemical properties of amino acids. The number of potentially electroactive amino acid residues, namely, tyrosine (Tyr), tryptophan (Trp), cysteine (Cys), histidine (His), methionine (Met), and cystine (Cys-Cys) located on the protein surface and orientated by their electroactive groups toward the electrode surface, i.e., accessible for electrochemical oxidation was calculated. The theoretical data were confirmed experimentally by cyclic and square-wave voltammetry. The available data on the protein structure allowed us to attribute the recorded electrochemical signals of thrombin oxidation to certain types of amino acid residue: the oxidation peak with a potential maximum at 0.7–0.8 V (vs. Ag/AgCl) was attributed to the oxidation of the Trp and Tyr residues; the wave in the range 1.0–1.2 V, to the oxidation of His; and the wave at 1.2–1.5 V, to the oxidation of Met and Cys-Cys. The electroanalysis based on the oxidation peak of the Tyr and Trp amino acid residues allowed to detect thrombin up to the concentration of 10–7 M. The suggested strategy for predicting the electrochemical activity can be used for investigating the properties of many other proteins and peptides and serve as a basis for their quantitative determination when developing various sensor and biosensor devices.  相似文献   

12.
《Electroanalysis》2018,30(8):1880-1885
This work presents a simple and low‐cost method for fast and selective determination of Verapamil (VP) in tablets and human urine samples using a boron‐doped diamond working electrode (BDD) coupled to a flow injection analysis system with multiple pulse amperometric detection (FIA‐MPA). The electrochemical behaviour of VP in 0.1 mol L−1 sulfuric acid showed three merged oxidation peaks at around +1.4 V and upon reverse scan, one reduction peak at 0.0 V (vs. Ag/AgCl). The MPA detection was performed applying a sequence of three potential pulses on BDD electrode: (1) at +1.6 V for VP oxidation, (2) at +0.2 V for reduction of the oxidized product and (3) at +0.1 V for cleaning of the working electrode surface. The FIA system was optimized with injection volume of 150 μL and flow rate of 3.5 mL min−1. The method showed a linear range from 0.8 to 40.0 μmol L−1 (R>0.99) with a low limit of detection of 0.16 μmol L−1, good repeatability (RSD<2.2 %; n=10) and sample throughput (45 h−1). Selective determination of VP in urine was performed at+0.2 V due to absence of interference from ascorbic and uric acids in this potential. The addition‐recovery tests in both samples were close to 100 % and the results were similar to an official method.  相似文献   

13.
The electrochemical behaviors of formaldehyde (FA) at boron‐doped diamond (BDD) electrodes are investigated by cyclic voltammetry (CV), electrochemical impedance spectroscopy (EIS), and linear scanning voltammetry (LSV) techniques. The CV results show that the oxidation reaction of FA is influenced by the hydroxyl concentration in the solution, and the peak current response with the FA concentration is linear at the range from 10 to 100 mM. The differential capacitance from EIS results indicate that the FA molecules adsorb at the BDD electrode surface at low potential (from 1.0 to 1.4 V). The kinetic studies have been examined with the various concentrations of FA, pH, and temperature. The activation energy of FA oxidation is also calculated. The results of kinetic study indicate that the adsorption of FA molecules at the BDD electrode is the rate‐determining step at low potential (from 1.0 to 1.40 V).  相似文献   

14.
The adsorption of nitrogen species, in neutral electrolyte solutions, onto boron-doped diamond (BDD) electrode surfaces from dissolved NO2, NO, and N2O gases was induced at 0 V/SCE. Modified BDD electrode surfaces showed a different electrochemical response toward the hydrogen evolution reaction than did a nonmodified electrode surface in electrolyte base solution. The formation of molecular hydrogen and nitrogen gaseous species was confirmed by the online differential electrochemical mass spectrometry (DEMS) technique. Among the three nitrogen oxides gases, NO2 substantially modifies the electrolyte via hydrolysis leading to the formation of NO3- and its adsorption on the BDD electrode surface. The BDD/(NO3-) interface was the only N2O and N2 species generating system.  相似文献   

15.
The analysis of tetracycline, oxytetracyline, chlortetracycline and doxycycline by high-performance liquid chromatography with pulsed amperometric detection using an anodized boron-doped diamond thin film (BDD) electrode is originally reported. The analyses were carried out using the mobile phase, phosphate buffer (0.01 M, pH 2.5)-acetonitrile (80:20; v/v), on a C18 column (250 x 4.6 mm i.d., 5 microm) at a flow rate of 1.0 mL/min. The optimal PAD waveform parameters at the anodized BDD were 1.5 V (versus Ag/AgCl) detection potential (E(det)) for 290 ms (200 ms delay time and 90 ms integration time), 2.0 V (versus Ag/AgCl) oxidation potential (E(oxd)) for 200 ms oxidation time (t(oxd)) and 0.4 V (versus Ag/AgCI) reduction potential (E(red)) for 200 ms reduction time (t(red)). The proposed method showed the simultaneous determination of tetracycline, oxytetracyline, chlortetracycline and doxycycline with a linear range of 0.1 - 100 microg/mL, detection limits of 0.05 - 0.1 microg/mL and recoveries of 70.8 - 96.0%. The application of this method to real samples was demonstrated and validated using a shrimp sample.  相似文献   

16.
The electrochemical properties of two-dimensional assemblies of 500 nm type Ib diamond particles are investigated as a function of their surface oxidation state. High Pressure High Temperature particles are sequentially exposed to a hot strong acid bath and to H(2) plasma in order to generate oxygen (ODP) and hydrogen surface terminations (HDP). Changes in the surface composition following the chemical treatments are confirmed by FTIR. Electrophoretic mobility measurements show that the diamond particles exhibit a negative surface charge at pH above 7 independently of the surface termination. Oxidation in the acid bath and subsequent reduction in the H(2) plasma only affects about 30% of the particle surface charge. The intrinsic negative charge allows the formation of 2D assemblies by electrostatic adsorption on poly(diallyldimethylammonium chloride) (PDADMAC) modified In-doped SnO(2) electrodes (ITO). The particle number density in the assembly was controlled by the adsorption time up to a maximum coverage of ca. 40%. Cyclic voltammetry in the absence of redox species in solution show that the acid treatment effectively removes responses associated with sp(2) carbon impurities, resulting in a potential independent capacitive signal. On the other hand, HDP assemblies are characterized by a charging process at a potential above 0.1 V vs Ag/AgCl. These responses are associated with hole-injection into the valence band edge which is shifted to approximately -4.75 eV vs vacuum upon hydrogenation. Information concerning the position of the valence band edge as well as hole number density at the HDP surface as a function of the applied potential are extracted from the electrochemical analysis.  相似文献   

17.
Nitrate adsorption and reduction on Cu(100) in acidic solution is studied by electrochemical methods, in situ electrochemical scanning tunneling microscopy (EC-STM), surface enhanced Raman spectroscopy (SERS), and density functional theory (DFT) calculations. Electrochemical results show that reduction of nitrate starts at -0.3 V vs Ag/AgCl and reaches maximum value at -0.58 V. Over the entire potential region interrogated adlayers composed of nitrate, nitrite, or other intermediates are observed by using in situ STM. From the open-circuit potential (OCP) to -0.22 V vs Ag|AgCl, the nitrate ion is dominant and forms a (2 x 2) adlattice on the Cu(100) surface while nitrate forms a dominantly c(2 x 2) structure from -0.25 to -0.36 V. The interconversion between the nitrate and nitrite adlattices is observed. DFT calculations indicate that both nitrate and nitrite are twofold coordinated to the Cu(100) surface.  相似文献   

18.
Boron-doped diamond (BDD) electrodes have been examined for the electrochemical oxidation of underivatized-nucleic acids in terms of single stranded and double stranded DNA. Cyclic voltammetry and square wave voltammetry have been used to study the oxidation reactions and to detect DNA without derivatization or hydrolysis steps. At the diamond electrode, at least two well-defined voltammetric peaks were observed for both single stranded and double stranded DNA. Diamond electrode is the first material to show a well-defined voltammetric peaks for adenine group oxidation directly in the helix structure of nucleic acid due to its wide potential window. For single stranded DNA, a third peak, related to the pyrimidine group oxidation was also observed. As-deposited diamond film with predominantly hydrogen-terminated surface exhibited superior performance over oxygen-terminated diamond in terms of sensitivity. However, by optimizing the ionic strength, sensitivity of O-terminated films could be improved. Linear calibration results have shown linearity of current with concentration in the range 0.1-8 microg mL(-1) for both guanine and adenine residues at as-deposited BDD. Detection limits (S/N = 3) of 3.7 and 10 ng mL(-1) for adenine and guanine residue in single stranded DNA, respectively, and 5.2 and 10 ng mL(-1) for adenine and guanine residue in double stranded DNA, respectively, were observed. This work shows the promising use of diamond as an electrochemical detector for direct detection of nucleic acids. The results also show the possibility of using the oxidation peak current of adenine group that is more sensitive for the direct detection of nucleicacids.  相似文献   

19.
利用硼掺杂金刚石(BDD)电极通过循环伏安法和微分脉冲伏安法研究了阿昔洛韦在0.10 mol/L磷酸盐缓冲溶液(pH 7.4)中的电化学行为及其与DNA的相互作用.与玻碳电极相比,阿昔洛韦在BDD电极上的循环伏安曲线在1.17 V处的氧化峰电流更大,背景电流较低.根据峰电位随溶液pH值和扫描速率的变化趋势考察了阿昔洛韦...  相似文献   

20.
A novel application of fluorine‐doped tin oxide (FTO) electrodes is reported in the present work. To this end, the captopril electrochemical oxidation mechanism on FTO electrodes at various pH and its determination in pharmaceutical preparations was investigated. Captopril oxidation on FTO proceeds at pH between 2.0 and 4.0. The study revealed that interferences for captopril determination in pharmaceutical samples was totally suppressed using these electrode materials. Voltammetric survey showed an anodic peak at about 0.375 V (Ag|AgCl) for captopril oxidation, that takes place through an EC process at pH interval 2.0–4.0. The investigation demonstrated that captopril oxidation occurs through protonated species and these electroactive species interact by adsorption on FTO electrodes, with a large heterogeneous rate constant and a mechanism involving 1H+/1e? in the global reaction. Moreover, a captopril sensor based upon FTO electrodes, with a linear range miliMolar, is proposed. These electrodes are promising candidates for the efficient electrochemical determination of captopril in pharmaceutical preparations.  相似文献   