首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
While nuclear magnetic resonance diffusion experiments are widely used to resolve structures confining the diffusion process, it has been elusive whether they can exactly reveal these structures. This question is closely related to x-ray scattering and to Kac's "hear the drum" problem. Although the shape of the drum is not "hearable," we show that the confining boundary of closed pores can indeed be detected using modified Stejskal-Tanner magnetic field gradients that preserve the phase information and enable imaging of the average pore in a porous medium with a largely increased signal-to-noise ratio.  相似文献   

2.
In magnetic resonance electrical impedance tomography (MREIT), currents are injected into an object, the resulting magnetic flux density is measured using MRI, and the conductivity distribution reconstructed using these MRI data. The relatively long acquisition times of conventional MREIT methods limit the signal averaging rate and are susceptible to motion artifacts. In this study, we reconstructed the conductivity distribution of an agarose gel phantom from data acquired in under a minute using a single-shot, spin echo, echo planar imaging (SS-SEPI) pulse sequence. The results demonstrate that SS-SEPI can be used for MREIT data acquisition.  相似文献   

3.
Magnetic resonance imaging (MRI) allows measurement of electric current density in an object. The measurement is based on observing how the magnetic field of the current density affects the associated spins. However, as high-field MRI is sensitive to static magnetic field variations of only the field component along the main field direction, object rotations are typically needed to image three-dimensional current densities. Ultra-low-field (ULF) MRI, on the other hand, with B0 on the order of 10–100 μT, allows novel MRI sequences. We present a rotation-free method for imaging static magnetic fields and current densities using ULF MRI. The method utilizes prepolarization pulses with adiabatic switch-off ramps. The technique is designed to reveal complete field and current-density information without the need to rotate the object. The method may find applications, e.g., in conductivity imaging. We present simulation results showing the feasibility of the sequence.  相似文献   

4.
Copper foil has been widely employed in conventional radio frequency (RF) birdcage coils for magnetic resonance imaging (MRI). However, for ultrahigh-field (UHF) MRI, current density distribution on the copper foil is concentrated on the surface and the edge due to proximity effect. This increases the effective resistance and distorts the circumferential sinusoidal current distribution on the birdcage coils, resulting in low signal-to-noise ratio (SNR) and inhomogeneous distribution of RF magnetic (B1) field. In this context, multiple parallel round wires were proposed as legs of a birdcage coil to optimize current density distribution and to improve the SNR and the B1 field homogeneity. The design was compared with three conventional birdcage coils with different width flat strip surface legs for a 9.4 T (T) MRI system, e.g., narrow-leg birdcage coil (NL), medium-leg birdcage coil (ML), broad-leg birdcage coil (BL) and the multiple parallel round wire-leg birdcage coil (WL). Studies were carried out in in vitro saline phantom as well as in vivo mouse brain. WL showed higher coil quality factor Q and more homogeneous B1 field distribution compared to the other three conventional birdcage coils. Furthermore, WL showed 12, 10 and 13% SNR increase, respectively, compared to NL, ML and BL. It was proposed that conductor’s shape optimization could be an effective approach to improve RF coil performance for UHF MRI.  相似文献   

5.
Today, all commonly practiced magnetic resonance imaging (MRI) reconstruction methods assume that the magnetic field created by the gradient coils is everywhere truncated by a dominant static uniform magnetic field. However, with the advent of SQUID detected MRI at microtesla fields, the opposite limit attracts attention, i.e., image formation in the unperturbed tensor field of the gradient coils. Here, we show by numerical simulations that, in principle, it is possible to reconstruct the image of an object in the absence of a uniform static field, working with the same gradient field setup as used in conventional MRI. Our calculations show that this approach could increase the image resolution limit attainable at low fields with a minimal incorporation of additional hardware and pulse sequences.  相似文献   

6.
Fast and quiet MRI using a swept radiofrequency   总被引:1,自引:0,他引:1  
A novel fast and quiet method of magnetic resonance imaging (MRI) is introduced which creates new opportunities for imaging in medicine and materials science. The method is called SWIFT, sweep imaging with Fourier transformation. In SWIFT, time-domain signals are acquired in a time-shared manner during a swept radiofrequency excitation of the nuclear spins. With negligible time between excitation and signal acquisition, new possibilities exist for imaging objects consisting of spins with extremely fast transverse relaxation rates, such as macromolecules, semi-solids, and quadrupolar nuclei. The field gradient used for spatial-encoding is not pulsed on and off, but rather is stepped in orientation in an incremental manner, which results in low acoustic noise. This unique acquisition method is expected to be relatively insensitive to sample motion, which is important for imaging live objects. Additionally, the frequency-swept excitation distributes the signal energy in time and thus dynamic range requirements for proper signal digitization are reduced compared with conventional MRI. For demonstration, images of a plastic object and cortical bone are shown.  相似文献   

7.
One of the main problems with rapid magnetic resonance imaging (MRI) techniques is the artifacts that result from off-resonance effects. The proposed off-resonance frequency filtered MRI (OFF-MRI) method focuses on the elimination of off-resonance components from the image of the observed object. To maintain imaging speed and simultaneously achieve good frequency selectivity, MRI is divided into two steps: signal acquisition and post-processing.  相似文献   

8.
A quantitative measure of three-dimensional breast density derived from noncontrast magnetic resonance imaging (MRI) was investigated in 35 women at high-risk for breast cancer. A semiautomatic segmentation tool was used to quantify the total volume of the breast and to separate volumes of fibroglandular and adipose tissue in noncontrast MRI data. The MRI density measure was defined as the ratio of breast fibroglandular volume over total volume of the breast. The overall correlation between MRI and mammographic density measures was R2=.67. However the MRI/mammography density correlation was higher in patients with lower breast density (R2=.73) than in patients with higher breast density (R2=.26). Women with mammographic density higher than 25% exhibited very different magnetic resonance density measures spread over a broad range of values. These results suggest that MRI may provide a volumetric measure more representative of breast composition than mammography, particularly in groups of women with dense breasts. Magnetic resonance imaging density could potentially be quantified and used for a better assessment of breast cancer risk in these populations.  相似文献   

9.
现有的磁共振电阻抗成像(MREIT)方法只适用于主磁场平行水平面的磁共振系统,本文中提出了一种新的MREIT方法即斜位电流注入磁共振电阻抗成像,同时适用于主磁场垂直于水平面的磁共振系统. 硬件系统以磁共振主控计算机为控制中心,将MRI与EIT有机结合于一体:(1)能够测量注入电流在成像体内部感应磁场的磁感应强度B(x,y,z);(2)向成像体注入电流;(3)满足时序匹配要求;(4)测量边界电压. 文章还展示了利用此装置所得的初步实验结果.  相似文献   

10.
实现了基于低场0.35 T磁共振成像系统的大脑功能磁共振成像(functional Magnetic Resonance Imaging,fMRI)的研究. 基于质子密度加权的快速自旋回波(Turbo Spin Echo,TSE)图像,重点研究增强低场fMRI显著性的方法,目的在于提高低场fMRI的可用性. 结果表明:健康受试者在执行手动任务期间,大脑运动区的信号强度变化可以由基于血管外质子信号增强 (Signal Enhancement by Extravascular water Protons,EEP)的对比机制探测. 优化TSE序列参数能提高图像SNR和扫描速度,并在统计分析中增加外在屏蔽图像,可以有效地提高低场下fMRI研究结果的显著性.  相似文献   

11.
为获得更优的成像质量和更快的成像速度,磁共振成像(MRI)系统的梯度预加重模块需要具有更多的补偿通道和调节参数,常规预加重模块的设计方案使现场可编程门阵列(FPGA)面临巨大的资源消耗.为解决高性能梯度预加重模块的资源消耗大的问题,本文提出了一种基于分时复用技术的梯度预加重实现方案,以常规方案1/44的资源实现了11通道×4组参数的梯度预加重模块.将该模块用于0.35 T MRI系统,测试了补偿前后的涡流曲线和磁共振图像,结果表明该模块有效降低了系统的涡流,减小了磁共振图像中的涡流伪影.  相似文献   

12.
The blood oxygenation level-dependent (BOLD) effect is the most commonly used contrast mechanism in functional magnetic resonance imaging (fMRI), due to its relatively high spatial resolution and sensitivity. However, the ability of BOLD fMRI to accurately localize neuronal activation in space and time is limited by the inherent hemodynamic modulation. There is hence a need to develop alternative MRI methods that can directly image neuroelectric activity, thereby achieving both a high temporal resolution and spatial specificity as compared to conventional BOLD fMRI. In this paper, we extend the Lorentz effect imaging technique, which can detect spatially incoherent yet temporally synchronized minute electrical activity in a strong magnetic field, and demonstrate its feasibility for imaging randomly oriented electrical currents on the order of microamperes with a temporal resolution on the order of milliseconds in gel phantoms. This constitutes a promising step towards its application to direct imaging of neuroelectric activity in vivo, which has the same order of current density and temporal synchrony.  相似文献   

13.

Purpose

Quantitative imaging of the rat skin was performed using magnetic resonance imaging (MRI) at 900 MHz.

Materials and methods

A number of imaging techniques utilized for multiple contrast included magnetization transfer contrast, spin-lattice relaxation constant (T1-weighting), combination of T2-weighting with magnetic field inhomogeneity (T2*-weighting), magnetization transfer weighting and diffusion tensor weighting. These were used to obtain 2D slices and 3D multislice-multiecho images with high magnetic resonance contrast. These 2D and 3D imaging techniques were combined to achieve high-resolution MRI.

Results

Oil–water phantom showed distinct fat-water contrast. The dermis and epidermis, including the stratum corneum remnants, of nude rat skin were distinct due to their proton magnetic resonance as a result of proton interactions with the skin interstitial tissue. Combined details obtained from high-resolution, high-quality ex vivo skin images with different multicontrast characteristics generated better differentiation of skin layers, sublayers and significant correlation (r2=0.4927 for MRI area, r2=0.3068 for histology area; P<.0148) of MR data with co-registered histological areas of the epidermis as well as the hair follicle.

Conclusion

The multiple contrast approach provided a noninvasive ex vivo MRI visualization with semi-quantitative assessment of the major skin structures including the stratum corneum remnants, epidermis, hair, papillary dermis, reticular dermis and hypodermis.  相似文献   

14.
磁共振分子影像学发展的主要瓶颈之一在于灵敏度的限制,基于激光光泵和自旋交换技术能获得增强4~5个量级的超极化129Xe磁共振信号,因此超极化129Xe磁共振分子影像学相对于传统MRI在灵敏度上表现出巨大的优势. 围绕提高灵敏度这一核心MRI问题及其在科学研究中的应用,该文介绍了目前基于超极化129Xe的生物分子探针的基本结构和原理,阐述了与之相关的分子影像学方法和技术,同时评述了当前的最新研究进展和发展方向.  相似文献   

15.
Electric current density can be measured noninvasively with magnetic resonance imaging (MRI). Determining all three components of the current density, however, requires physical rotation of the sample or current injection from several directions when done with conventional methods. However, the emerging technology of ultra-low-field (ULF) MRI, in which the signal encoding and acquisition is conducted at a microtesla-range magnetic field, offers new possibilities. The low applied magnetic fields can even be switched off completely within the pulse sequence, increasing the flexibility of the available sequences. In this article, we present a ULF-MRI sequence designed for obtaining all three components of a current-density pattern without the need of sample rotations. The sequence consists of three steps: prepolarization of the sample, signal encoding in the current-density-associated magnetic field without applying any MRI fields, and spatial encoding in a microtesla-range field using any standard ULF-MRI sequence. The performance of the method is evaluated by numerical simulations. The method may find applications, e.g., in noninvasive conductivity imaging of tissue.  相似文献   

16.
The role of magnetic resonance imaging and plain radiographs in evaluating osteomyelitis in the diabetic foot was studied. Fifty patients were prospectively examined by magnetic resonance imaging and plain radiographs to determine the extent of infection. Thirty-seven patients had positive MRI for osteomyelitis and 19 were positive with conventional radiography. Thirteen patients had negative MRI healed with short course of antibiotics. Five patients with positive MRI received four weeks' course of intravenous antibiotics with two still having persistent infection in the six weeks follow-up. Thirty-two patients underwent surgery with favorable results. Sixty-two bone specimens were obtained for histologic evaluation of osteomyelitis. In cases with histologic proof of diagnosis, magnetic resonance sensitivity was 99%, specificity was 81%, and accuracy was 94%. Thus magnetic resonance imaging was shown to have a high sensitivity, specificity, and accuracy in detecting osteomyelitis.  相似文献   

17.
Lack of spatial accuracy is a recognized problem in magnetic resonance imaging (MRI) which severely detracts from its value as a stand-alone modality for applications that put high demands on geometric fidelity, such as radiotherapy treatment planning and stereotactic neurosurgery. In this paper, we illustrate the potential and discuss the limitations of spectroscopic imaging as a tool for generating purely phase-encoded MR images and parameter maps that preserve the geometry of an object and allow localization of object features in world coordinates.  相似文献   

18.
Magnetic resonance imaging of spinal intradural granulocytic sarcoma   总被引:1,自引:0,他引:1  
We report the case of a young black male with a spinal intradural granulocytic sarcoma proved by needle aspiration. The tumor was evaluated by myelography, computed tomography, and magnetic resonance imaging (MRI). Other than its rarity, the "dripping candle wax" appearance on MR T1-weighted images and the lack of enhancement with Gd-DTPA makes this case unique. Progressive changes of the tumor following chemo- and radiotherapy were successfully demonstrated by MR.  相似文献   

19.
Magnetic rotation and antimagnetic rotation are exotic rotational phenomena observed in weakly deformed or near-spherical nuclei, which are respectively interpreted in terms of the shears mechanism and two shearslike mechanism. Since their observations, magnetic rotation and antimagnetic rotation phenomena have been mainly investigated in the framework of tilted axis cranking based on the pairing plus quadrupole model. For the last decades, the covariant density functional theory and its extension have been proved to be successful in describing series of nuclear ground-states and excited states properties, including the binding energies, radii, single-particle spectra, resonance states, halo phenomena, magnetic moments, magnetic rotation, low-lying excitations, shape phase transitions, collective rotation and vibrations, etc. This review will mainly focus on the tilted axis cranking covariant density functional theory and its application for the magnetic rotation and antimagnetic rotation phenomena.  相似文献   

20.
Electric current-induced phase alternations have been imaged by fast magnetic resonance image (MRI) technology. We measured the magnetic resonance phase images induced by pulsed current stimulation from a phantom and detected its sensitivity. The pulsed current-induced phase image demonstrated the feasibility to detect phase changes of the proton magnetic resonance signal that could mimic neuronal firing. At the present experimental setting, a magnetic field strength change of 1.7 +/- 0.3 nT can be detected. We also calculated the averaged value of the magnetic flux density BT parallel to B0 produced by electric current I inside the voxel as a function of the wire position. The results of the calculation were consistent with our observation that for the same experimental setting the current-induced phase change could vary with location of the wire inside the voxel. We discuss our findings in terms of possible direct MRI detection of neuronal activity.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号