首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Micellar systems composed of surfactants are used extensively in academia and industry for many different applications. In this work a highly versatile CE method for determination of CMCs of charged surfactants has been developed. In the case of positively charged surfactants a coating procedure of the fused-silica capillary was used, whereas negatively charged surfactants were analyzed using uncoated capillaries. The CE method is based on frontal analysis (FA) employing use of contactless conductivity and UV detection. The main advantages of the method are that it can be used for non-UV absorbing surfactants without introducing marker compounds which previously has been found to affect CMCs, requires very limited sample volume and is easily implemented and automated using standard CE equipment. The fact that counterions and different aggregated states are separated allows a detailed characterization of the micelle systems using the developed method. In the case of UV absorbing surfactants similar results were obtained employing contactless conductivity and UV detection. Finally, CMCs obtained using conductometry gave similar results as compared to the developed CE-FA procedure.  相似文献   

2.
We have developed a reversed-phase high-performance liquid chromatography pulsed amperometric detection (RP-HPLC-PAD) method for the determination of glycosides. It is sensitive, repeatable, and selective without the pretreatment step. Ginsenosides were separated completely in 50 min using an water-acetonitrile gradient as the eluent and detected by PAD under NaOH alkaline conditions. The ginsenoside detection limit (S/N=3) was 0.02-0.07 ng and the quantification limit (S/N=10) was 0.1-0.2 ng. The coefficient of linear regression was 0.9984-0.9998 for concentrations between 1 and 50 microg/mL. The intra- and inter-day precision (RSD) was less than 6.35% in Ginseng Radix and Shy-jiun-tzyy-tang extracts. The average recoveries from Ginseng Radix and Shy-jiun-tzyy-tang extracts were 98.19-105.45% and 96.89-102.22%, respectively.  相似文献   

3.
Summary A reversed-phase high-performance liquid chromatographic method for the determination of chloride in plasma, urine, saliva, sweat and aqueous solution is described. Chloride, in solution in aqueous acetone, is converted by means of pentafluorobenzyl bromide into pentafluorobenzyl chloride. This derivative is separated on a ODS-5 m reversed-phase column using isocratic elution with acctonitrile/water, 50/50, v/v, at a flow rate of 2.0 ml/min, and detected by a UV detector at 264 nm. The method is rapid, accurate and sufficiently sensitive for the determination of chloride in less than 10 l sample volume of a biological fluid.  相似文献   

4.
5.
6.
Reversed-phase high-performance liquid chromatography (HPLC) is directly coupled to helium microwave-induced plasma mass spectrometry (He MIP-MS) for the element-selective detection of halogenated organic compounds. Absolute detection limits are approximately 50 pg Br for brominated compounds, 1 pg I for iodinated compounds, and 10 ng Cl for chlorinated compounds. The linear dynamic range for Br- and I-containing compounds is 3-4 orders of magnitude. However, the linear range for chlorinated species is severely limited by high background at m/z = 35. The relative standard deviation for repetitive injections is less than 10%. The helium microwave-induced plasma is operated at moderate powers (300-350 W) and with a total helium consumption of 6-8 L/min. The effect of organic solvents on the background mass spectrum is investigated.  相似文献   

7.
A reversed-phase high-performance liquid chromatography method using evaporative light-scattering detection is developed for the determination of residual octylglucoside (OG) levels after a detergent exchange step for in-process samples of a vaccine antigen. The reversed-phase column not only provides separation of the OG but also functions as an extraction column to remove the vaccine antigen from the sample, thereby eliminating off-line sample manipulations. In addition to column selection, the mobile phase is optimized to enhance extraction and separation. The vaccine antigen is irreversibly bound to the column, allowing nonprotein components to interact with the column for separation and elution. The assay is linear over the range of 0.00050-0.050% OG. Precision tested at 0.0010% and 0.0050% OG is 2.9% and 7.2% relative standard deviation, respectively. The limits of quantitation and detection are determined to be 0.00050 and 0.000125% OG, respectively. Accuracy is determined to be 103 and 98%, based on spike recoveries of 0.0010% and 0.0050% OG, respectively.  相似文献   

8.
For the determination of beta-aminoisobutyric acid (BAIBA) in urine samples in which the beta-alanine concentrations are higher than those of BAIBA, the resolution between these two amino acids, separated by reversed-phase liquid chromatography on an octadecylsilane column, was optimized. The chromatographic analysis included precolumn derivatization of amino acids with o-phthalaldehyde, followed by a 15-min isocratic elution and detection at 340 nm. Because of its simplicity, this method should be useful for monitoring urinary excretion of BAIBA.  相似文献   

9.
Gradient programs were applied to the determination of peptides and proteins in HPLC with contactless conductivity detection. A monolithic capillary column was used for the fast and sensitive determination of the biochemical species in acidic mobile phases consisting of acetic acid or trifluoroacetic acid in various concentrations of acetonitrile in water. The drift in baseline, which is caused by conductivity changes during the elution program, was minimized by careful optimization of the composition of the mobile phase and remaining drift was removed by computational baseline normalization. The flow rate from a conventional HPLC pump was reduced to a flow rate suitable for capillary systems using a pre-column flow splitter and a final total flow rate of 1.65 microl/min was used for all capillary HPLC separations. The contactless conductivity detector was positioned directly on the outlet capillary of the separation column and positively charged peptides and proteins were determined as sharp and symmetrical peaks. Detection limits in a concentration range from 3.7 x 10(-8) to 5.1 x 10(-7)M and a reproducibility of peak areas and peak heights between 2.3% and 7.3% were achieved for all biochemical species tested.  相似文献   

10.
Three reversed-phase systems [based on the divinylbenzene-styrene copolymer (PRP-1), the C18-derivatized divinylbenzene-styrene copolymer (ACT-1), and the Nucleosil C8 columns] were studied for their suitability in lipophilicity determination. Acetonitrile-water was selected as the mobile phase. Correlation between log k′ and log Pcyc for both the PRP-1 and Nucleosil C8 systems was superior to the correlation between log k′ and either log Poct or log Pcyc (oct = octanol; CYC = cyclohexane) on the ACT-1 column. On the PRP-1 and Nucleosil columns, correlation between log k′ and log Poct was much improved when test compounds were grouped into classifications of non-H bonding, single amphiprotics (alcohols, phenols, amides) or double amphiproties. Although the PRP-1 system gave broad peaks with lipophilic substrates, there was good correlation between log k′ values on the Nucleosil silica-based reversed-phase system and the polymer PRP-1 system, indicating that either is suitable for the determination of lipophilicity.  相似文献   

11.
The separation of peptides during RP-HPLC depends mainly upon differential hydrophobic interactions of the individual peptides being separated with the C18 group of the stationary phase. We have examined the behavior of dimeric disulfide-linked model peptides during RP-HPLC in order to study self-induced conformational effects. A set of 18 analogues of the amphipathic alpha-helical sequence Ac-LKLLKKLLKKLKKLLKKL-NH2 was used for this study. These analogues differed only by the successive replacement of each position with a cysteine. Strong peptide-peptide interactions, occurring through interchain hydrophobic forces, resulted in a presenting face to the C18 group, consisting primarily of lysine residues and, in turn, in early retention times. Three homo-dimers were also found to be strongly alpha-helical in water as determined by circular dichroism spectroscopy.  相似文献   

12.
The author describes a method of using reversed-phase high-performance liquid chromatography with fluorimetric detection for the assay of diclofenac sodium in serum. The method is sensitive down to 20 ng/ml (250-microliters loop). Elution is at pH 6.2 with methanol in 0.05 M phosphate buffer (43:57, v/v) on a 25-cm Spherisorb S5 ODS2 column. Detection is at an excitation wavelength of 282 nm and an emission wavelength of 365 nm. Serum sample size is 100 microliters. Sample protein, to which diclofenac is highly bound, is first denatured by heat and then with methanol to release the diclofenac prior to centrifugation and injection of 100 microliters (or 250 microliters) of the clear supernatant. Harmol, with similar fluorescence and polarity characteristics to diclofenac, is a satisfactory internal standard. At the 1 micrograms/ml level intra-sample reproducibility is better than 2%, whilst inter-sample reproducibility is 4.6%. Detector response is linear from 40 ng/ml to 20 micrograms/ml (100-microliters loop).  相似文献   

13.
A method for the simultaneous determination of E-2-nonenal and beta-damascenone in beer by reversed-phase liquid chromatography using UV detection is presented. The method consists of beer steam distillation, followed by an extraction/concentration step using Sep-Pak Plus C18 RP cartridges and determination by HPLC at 226 nm UV-absorption maximum. The identity of the compounds was confirmed by GC analysis with MS detection of the isolated fractions. A recovery factor of approximately 80% was obtained for beta-damascenone with a R.S.D. of 3%. E-2-Nonenal and beta-damascenone were monitored in a comparative study of fresh and either naturally and forced aged beer. The results obtained show that both compounds have a similar behaviour through an extended storage of beer and consequently can be used as good analytical markers of beer ageing. Nevertheless, the use of beta-damascenone seems to be more convenient because this compound appears in beer in higher concentrations than E-2-nonenal, thus making it easier to measure.  相似文献   

14.
A sensitive determination method for melatonin was developed. Melatonin was derivatized under alkaline conditions in the presence of hydrogen peroxide. The resultant fluorophore was excited at 247 nm and the emission wavelength was 384 nm. The Stokes shift was 137 nm, which was longer than that of melatonin itself (lambda ex 280 nm, lambda em 330 nm). The melatonin derivative was separated by reversed-phase HPLC in about 15 min and the calibration curve was linear from 500 amol to 5 pmol (r > 0.999) with the detection limit of 500 amol (S/N = 5). The sensitivity of this method was about ten times higher than that of previous methods. Both the day-to-day precision and within-day precision were about 5%, and the derivative of melatonin in the aqueous solution was stable for more than 10 days. This method was successfully applied to the determination of melatonin in rat pineal gland.  相似文献   

15.
A rapid high-performance liquid chromatographic method is described for separating and quantifying four bilirubin species present in serum: bilirubin, bilirubin monoglucuronide, bilirubin diglucuronide, and bilialbumin. Sample preparation consists of dilution with ascorbic acid and dimethylsulfoxide and filtration to remove solid materials. The diluted serum was injected directly onto a wide-pore (300 A) reversed-phase column and the bilirubin species eluted with a water-isopropanol gradient. Excellent agreement was found between the total bilirubin concentration measured by the high-performance liquid chromatographic method and a diazotized sulfanilic acid procedure.  相似文献   

16.
The retention behavior of molecular species of phosphatidylcholine (PC) is studied by reversed-phase (RP) ion-pair high-performance liquid chromatography (HPLC). Mobile phases contain tetraalkyl ammonium phosphates (TAAPs) in methano-acetonitrile-water. The stationary phase is alkyl-bonded silica. Competitive interactions of TAAPs, analyte solutes, and an RP-HPLC column result in reduced retention of PC molecular species. PC molecular species are eluted at longer retention times with a larger size of TAAP in the mobile phase, and an increase in the TAAP concentration invariably causes a decrease in PC molecular species retention times. There is a linear correlation between the logarithmic retention factors (k) of PC molecular species and the total number of carbon atoms of TAAP, and the logarithm of k values of PC molecular species can be approximated as a linear function of the logarithm of the counter-ion concentration. There is found to be no distinct dependence between k values of PC molecular species and the mobile phase pH.  相似文献   

17.
18.
19.
A cloud-point extraction (CPE) method using Triton X-114 non-ionic surfactant was developed for the extraction and preconcentration of carbamate insecticide residues (i.e., methomyl, propoxur, carbofuran, carbaryl, isoprocarb, and promecarb) in fruit samples. The optimum conditions of CPE were 1.5% (w/v) Triton X-114, 7.0% (w/v) NaCl and 20 min equilibrated at 45 °C. The surfactant-rich phase was then analyzed by reversed-phase high-performance liquid chromatography with ultraviolet detection at 270 nm, under gradient separation using methanol and 0.1% (v/v) acetic acid. Under the study conditions, six carbamate insecticides were successfully separated within 27 min. Good reproducibility was obtained with the relative standard deviation of <3% for retention time and <9% for peak area. Limits of detection in the studied fruit samples were in the range of 0.1–1.0 mg kg−1. No carbamate insecticides were detected in the studied fruit samples. The high recoveries of the spiked fruit samples were obtained in the range 80.0–107%. The CPE method has been shown to be a potential useful methodology for the preconcentration of the target analytes, with a preconcentration factor of 14. Moreover, the method is simple, has high sensitivity, consumes much less solvent than traditional methods, and is environmental friendly.  相似文献   

20.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号