首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Rincón AA  Pino V  Ayala JH  Afonso AM 《Talanta》2011,85(3):1265-1273
The content of ten phenolic compounds present in four different biomass smoke materials: rock rose (Cistus monpelienisis), prickly pear (Opuntia ficus indica), pine needles (Pinus canariensis), and almonds skin (Prunus dulcis), have been evaluated. The sampling method mainly consisted of a trap alkaline solution to solubilize the phenols, and was optimized by an experimental design. Average sampling efficiencies of 78.1% and an average precision value of 10.6% (as relative standard deviation, RSD), were obtained for the selected group of phenols. The trapped phenolates were further analyzed by a headspace-single drop microextraction (HS-SDME) procedure, in combination with high-performance liquid chromatography (HPLC) with UV detection. The optimum variables for the HS-SDME method were: 1-decanol as extractant solvent, 3.5 μL of microdrop volume, 2 mL of sample volume, a pH value of 2, saturation of NaCl, an extraction temperature of 60 °C, and an extraction time of 25 min. The optimized HS-SDME method presented detection limits ranging from 0.35 to 5.8 μg mL−1, RSD values ranging from 0.7 to 7.4%, and an average relative recovery (RR) of 99.8% and an average standard deviation of 5.2. The average content of phenolic compounds in the biomass materials studied were 70, 161, 206 and 252 mg kg−1 of biomass for prickly pear, almonds skin, rock rose, and pine needles, respectively. The main components of the smokes were vanillin, phenol and methoxyphenols, in all smoking materials studied.  相似文献   

2.
The aim of this work was to identify the degradation compounds produced during irradiation of multilayer polyamide 6 (PA-6) films and to study their migration into water and 95% ethanol food simulant. After irradiation of multilayer PA-6 films at 3, 7 and 12 kGy, degradation compounds were extracted using solid-phase microextraction, for which the time and temperature of extraction and stirring were optimized, and identified by gas chromatography–mass spectrometry. Caprolactam, 2-cyclopentylcyclopentanone and aldehydes, among other compounds, were identified in the headspace of the films. Polydimethylsiloxane was considered the best fiber for extraction. The optimum conditions of time, temperature and stirring to extract the compounds were 20 min, 80 °C and 225 rpm. For validation purposes, the compounds were quantified in water and 95% ethanol and the results showed high sensitivity, good precision and accuracy. Migration of compounds from irradiated and non-irradiated multilayer PA-6 films into water and 95% ethanol food simulants was carried out at 40 °C for 10 days. The method was efficient for the quantification of decaldehyde, 2-cyclopentylcyclopentanone and caprolactam that migrated from multilayer PA-6 films into food simulants.  相似文献   

3.
Volatile compounds of grapes are responsible of varietal aroma. At the moment, methods used for analysis of these compounds are solvent-based, time-consuming and generally require large amounts of sample. In order to obtain an appropriate technique to study grape volatile compounds, HS-SPME method has been developed. The optimal sampling conditions were: 70 °C for 20 min with a 65-μm PDMS/DVB fibre. Sixteen volatile compounds have been quantified in pulp and skins of Muscat grapes. Terpenes, mainly linalool, geraniol and nerol, have been the volatiles present in the highest concentration, since these compounds contribute, to a larger extent, to the aroma of Muscat grapes and wines. So the proposed technique can be used for the characterisation of grape varieties or cultivars and for the determination of the aromatic maturity of grapes.  相似文献   

4.
A solid-phase microextraction method (SPME) followed by gas chromatography with micro electron capture detection for determining trace levels of nitro musk fragrances in residual waters was optimized. Four nitro musks, musk xylene, musk moskene, musk tibetene and musk ketone, were selected for the optimization of the method. Factors affecting the extraction process were studied using a multivariate approach. Two extraction modes (direct SPME and headspace SPME) were tried at different extraction temperatures using two fiber coatings [Carboxen–polydimethylsiloxane (CAR/PDMS) and polydimethylsiloxane–divinylbenzene (PDMS/DVB)] selected among five commercial tested fibers. Sample agitation and the salting-out effect were also factors studied. The main effects and interactions between the factors were studied for all the target compounds. An extraction temperature of 100 °C and sampling the headspace over the sample, using either CAR/PDMS or PDMS/DVB as fiber coatings, were found to be the experimental conditions that led to a more effective extraction. High sensitivity, with detection limits in the low nanogram per liter range, and good linearity and repeatability were achieved for all nitro musks. Since the method proposed performed well for real samples, it was applied to different water samples, including wastewater and sewage, in which some of the target compounds (musk xylene and musk ketone) were detected and quantified. Figure Stardardized Pareto charts for the main effects and interactions  相似文献   

5.
Verónica Pino 《Talanta》2007,73(3):505-513
This work combines the utilization of the micellar media during the extraction step and the focused microwave-assisted extraction followed by the solid-phase microextraction-gas chromatography/mass spectrometry (SPME-GC/MS) to determine the alkyl- and methoxy-phenolic content in wood extractives. The proposed environmental-friendly method is mainly characterized by short analysis times (5 min for the microwaves extraction step) and for avoiding the use of organic solvents. Different surfactants were tried for the extraction process: the cationic surfactant CTAB and the non-ionic surfactants Triton X-100 and POLE, with similar extraction efficiencies (85.5-99.7%). The overall method presents limits of detection in the ng g−1 region for the alkylphenols (from 7 to 150 ng g−1) and in the μg g−1 region for the methoxyphenols (from 0.80 to 22.9 μg g−1). The vanillin was the compound most abundant in the wood extractives studied, with concentrations up to 116.2 mg kg−1.  相似文献   

6.
The aqueous instability of pyrethroids and other compounds usually found in commercial pesticide formulations has been demonstrated in this work. Several types of sample treatment have been studied to avoid analyte losses during sample manipulation and storage. Analysis was performed by SPME–GC–MS. Addition of sodium thiosulfate to tap water prevented pyrethroid degradation as a result of oxidation by free chlorine. The amount added was optimized to minimize the effect of the salt on the analytical results. Analysis of samples that had been stored at 4 °C for several days revealed loss of some of the pyrethroids in the first period of storage. The effect of freezing the samples was studied and it was confirmed that samples could be stabilized for at least one week by freezing. Finally, addition of a miscible organic solvent, for example acetone, led to improvement of the analytical precision. The quality of the SPME–GC–MS method was studied. Linearity (R > 0.993), repeatability (RSD < 15%), and sensitivity (detection limits between 0.9 and 35 pg mL−1) were good. When the procedure was applied to real samples including run off and waste water some of the target compounds were identified and quantified.   相似文献   

7.
A robotic method has been established for the determination of bromate in sea water and drinking deep-sea water. Bromate in water was converted into volatile derivative, which was measured with headspace solid-phase micro extraction and gas chromatography–mass spectrometry (HS-SPME GC–MS). Derivatization reagent and the HS-SPME parameters (selection of fibre, extraction/derivatization temperature, heating time and; the morality of HCl) were optimized and selected. Under the established conditions, the detection and the quantification limits were 0.016 μg L−1 and 0.051 μg L−1, respectively, and the intra- and inter-day relative standard deviation was less than 7% at concentrations of 1.0 and 10.0 μg L−1. The calibration curve showed good linearity with r2 = 0.9998. The common ions Cl, NO3, SO42−, HPO42−, H2PO4, K+, Na+, NH4+, Ca2+, Mg2+, Ba2+, Mn4+, Mn2+, Fe3+ and Fe2+ did not interfere even when present in 1000-fold excess over the active species. The method was successfully applied to the determination of bromate in sea water and drinking deep-sea water.  相似文献   

8.
In this work, headspace solid-phase micro-extraction (SPME) combined with gas chromatography-mass spectrometry (GC-MS) method for analysis of butyltin compounds in sediment samples was upgraded by the introduction of tandem mass spectrometry (MS/MS). Optimization and validation of this method based on an one step procedure, tetraethylborate in situ ethylation with simultaneous extraction by headspace SPME, combined with tandem mass spectrometry is described. A simple leaching/extraction step of mono-(M), di-(D) and tri-(T) butyltin (BT) compounds from the sediment is required as sample pre-treatment. The combination of the two techniques headspace SPME and MS/MS, led to very little matrix interference which permitted to attain limits of detection three or more orders of magnitude lower than those attained in previous methods: 0.3 pg g− 1 for MBT, 1 pg g− 1 for DBT and 0.4 pg g− 1 for TBT. Linear response range was from 0.02–1260 ng g− 1 for MBT, 0.07–1568 ng g− 1 for DBT and 0.04–2146 ng g− 1 for TBT and RSD < 15% was also obtained. The method was efficiently applied to a real sample sediment from Sado River estuary in Portugal, revealing the existence of BTs pollution, as the TBT level of 189 ± 15 ng g− 1 was much higher than the maximum established as provisional ecotoxicological assessment criteria.  相似文献   

9.
Summary A rapid, accurate and sensitive method is described for the analysis of phenolic compounds, including phenol, alkylphenols, halogenated phenols and nitrophenols in tap, ground and river water samples. The method consists in direct acetylation of the aqueous phenols with acetic anhydride, extraction of the phenol acetates with a C18 disk and analysis by gas chromatography with an ion-trap detector mass spectrometer. Using this method, the sample preparation time was approximately 1.5 h for six 1-L water samples, and recoveries for most of the phenolic compounds studied were more than 80% at concentration levels of 0.1 and 1.0g L–1. The detection limits were in the range 2 to 15 ng L–1 for phenol, alkylphenols and halogenated phenols, and 25 to 50 ng L–1 for nitrophenols.  相似文献   

10.
Determination of drugs of abuse in blood is of great importance in clinical and forensic toxicology. This review describes procedures for detection of the following drugs of abuse and their metabolites in whole blood, plasma or serum: Δ9-tetrahydrocannabinol, 11-hydroxy-Δ9-tetrahydrocannabinol, 11-nor-9-carboxy-Δ9-tetrahydrocannabinol, 11-nor-9-carboxy-Δ9-tetrahydrocannabinol glucuronide, heroin, 6-monoacetylmorphine, morphine, morphine-6-glucuronide, morphine-3-glucuronide, codeine, amphetamine, methamphetamine, 3,4-methylenedioxymethamphetamine, N-ethyl-3,4-methylenedioxyamphetamine, 3,4-methylenedioxyamphetamine, cocaine, benzoylecgonine, ecgonine methyl ester, cocaethylene, other cocaine metabolites or pyrolysis products (norcocaine, norcocaethylene, norbenzoylecgonine, m-hydroxycocaine, p-hydroxycocaine, m-hydroxybenzoylecgonine, p-hydroxybenzoylecgonine, ethyl ecgonine, ecgonine, anhydroecgonine methyl ester, anhydroecgonine ethyl ester, anhydroecgonine, noranhydroecgonine, N-hydroxynorcocaine, cocaine N-oxide, anhydroecgonine methyl ester N-oxide). Metabolites and degradation products which are recommended to be monitored for assessment in clinical or forensic toxicology are mentioned. Papers written in English between 2002 and the beginning of 2007 are reviewed. Analytical methods are assessed for their suitability in forensic toxicology, where special requirements have to be met. For many of the analytes sensitive immunological methods for screening are available. Screening and confirmation is mostly done by gas chromatography (GC)–mass spectrometry (MS) or liquid chromatography (LC)–MS(/MS) procedures. Basic information about the biosample assayed, internal standard, workup, GC or LC column and mobile phase, detection mode, and validation data for each procedure is summarized in two tables to facilitate the selection of a method suitable for a specific analytic problem.  相似文献   

11.
A novel method of determining organochlorine pesticides (OCPs) is described. It is based on solid-phase microextraction (SPME) and gas chromatography–electron capture detection. During the development of the method, soil samples were prepared, spiked with standard solution, and then aged for some time. Extraction conditions such as the extraction time, the NaCl content, the volume of water, the extraction temperature and the desorption time were investigated and optimized. The limits of detection obtained using the method ranged from 0.10 to 0.51 ng g−1, and relative standard deviations were lower than 10% for most organochlorine pesticides. Real soil samples were successfully analyzed using the proposed method. The results from the method developed here were in good agreement with those obtained using ultrasonic extraction. The result demonstrates that aging soils spiked with standard solution is an important method development step, because the soil samples obtained using this approach are more like real soils than those obtained when aging is not used.   相似文献   

12.
The determination of five volatile organochlorine compounds, VOX (chloroform, 1,1,1-trichloroethane, carbon tetrachloride, trichloroethene and tetrachloroethene) in raw landfill leachates and biologically cleansed leachates by GC-MS is investigated. Two extraction and preconcentration procedures were evaluated for recovery of such analies from the samples, including static headspace (HS) and solid phase microextraction by sampling the headspace above the sample (HS-SPME). Optimisation of operating parameters for the best performance of both, sampling and preconcentration techniques was described. Detection limits, time of analysis, precision and linear ranges of both introduction techniques have been established. Application of proposed methods to the determination of the five VOX under study in the above referred samples revealed the absence of such analytes in both leachates. Then both methods were applied to the determination to the five organochlorine compounds under study on spiked leachates samples. While HS-GC-MS offered better analytical precision than HS-SPME-GC-MS, this last technique gave a faster analytical response because no dilution must be done for a reliable VOX determination in landfill leachates. In any case, both sample introduction techniques tested provides excellent recoveries and good analytical precision (ranged from 1 to 3%).  相似文献   

13.
Summary A fast and simple headspace SPME sampling method has been developed for quantification of volatile aliphatic aldehydes in sunflower oil. Analysis has been performed by gas chromatography, on a 30m×0.25 mm i.d. ×0.25 μm CP-Wax 52CB column, with mass spectrometric detection. Carryover from the SPME fiber could be eliminated by heating the fiber in the injection port between runs. Response factors of all the compounds were linear for concentrations up to 100 ng μL−1. The slopes of the calibration curves decrease with the amount of saturation of the aldehydes. The average responses for unsaturated aldehydes were twice as high as those for the saturated variety. Responses for dienes were approximately one order of magnitude higher than for saturated aldehydes. Depletion of the analyte was examined by repeated extraction from the same vial. SPME was optimized—after 30 min extraction most components were found to have reached equilibration. The detection limit for the compounds studied varied between 0.1 and 1 ng μL−1. Distribution constants were determined for ten different aldehydes and Henry's constants were calculated for unsaturated aldehydes. There was a definite relationship between the response factors and the amount of saturation of the aldehydes. Presented at: Balaton Symposium on High-Performance Separation Methods, Siófok, Hungary, September 3–5, 1997  相似文献   

14.
Fentanyl, a kind of intravenous narcotic analgesic, is widely used in clinical anesthesia. As a potential pollution, it was detected in both the air of the cardiothoracic operating room and patients' expiratory circuit. However, whether the fentanyl in patients' expiratory circuit is exhaled by patients is unknown. In this study, breath samples were taken from the expiratory circuits of anesthetic machine linked to the patients who received intravenous fentanyl, a solid-phase microextraction (SPME) coupled with gas chromatography–mass spectrometry (GC–MS) method was developed to detect and quantify fentanyl in breath samples. The parameters influencing adsorption (extraction time, temperature,) and desorption (desorption time) of the analyte on the fiber were investigated and validated for method development. The developed method was proved to be simple, easy, and inexpensive and offer high sensitivity and reproducibility. Linear range was obtained from 0.05 ng/mL to 0.8 ng/mL. The limit of detection was 0.01 ng/mL while an interday precision of less than 12.13% (n = 5) could be achieved. Six patients were involved in this study; results showed presence of fentanyl in the breath of patients who received intravenous fentanyl, and fentanyl concentrations in breath varied from 6.00 to 20.89 pg/mL. In conclusion, fentanyl can be exhaled by patients who received intravenous fentanyl.  相似文献   

15.
In this work an analytical procedure based on headspace solid-phase microextraction and gas chromatography coupled with mass spectrometry (HS-SPME–GC/MS) is proposed to determine chlorophenols with prior derivatization step to improve analyte volatility and therefore the decision limit (CCα). After optimization, the analytical procedure was applied to analyze river water samples. The following analytes are studied: 2,4-dichlorophenol (2,4-DCP), 2,4,6-trichlorophenol (2,4,6-TrCP), 2,3,4,6-tetrachlorophenol (2,4,6-TeCP) and pentachlorophenol (PCP). A D-optimal design is used to study the parameters affecting the HS-SPME process and the derivatization step. Four experimental factors at two levels and one factor at three levels were considered: (i) equilibrium/extraction temperature, (ii) extraction time, (iii) sample volume, (iv) agitation time and (v) equilibrium time. In addition two interactions between four of them were considered. The D-optimal design enables the reduction of the number of experiments from 48 to 18 while maintaining enough precision in the estimation of the effects. As every analysis took 1 h, the design is blocked in 2 days.  相似文献   

16.
The seeming “dual nature” of ionic liquids (ILs) for separating both apolar and polar compounds suggests that ILs may have a great potential for complex samples like essential oils from herbal plants that contain a great variety of compounds. In the present work, a geminal dicationic IL, 1,9-di(3-vinylimidazolium)nonane bis[(trifluoromethyl)sulfonyl]imidate, was investigated for this purpose. To find the best way to achieve satisfactory separations simultaneously for the compounds in essential oils, the dicationic IL was used as the stationary phase for capillary gas chromatography (GC) in two ways, either in its pure state or as a mixed stationary phase with monocationic ILs and a polysiloxane diluent. Interestingly, it was found that the mixed stationary phase exhibited a much better selectivity for polar and nonpolar compounds than either the dicationic IL or the polysiloxane, suggesting that a kind of synergistic effect occurred when these stationary phases were combined in the way described. A comparison with two commercial stationary phases (polar and nonpolar) indicated that this novel mixed stationary phase behaved in a way closer to a polar stationary phase in terms of selectivity and elution order. The present work demonstrates that the mixed stationary phase is efficient and selective and can be an alternative choice for the GC analysis of samples of complex composition. Figure Divinyldiimidazolium-based ionic liquid stationary phase  相似文献   

17.
The profile of volatile compounds released from 13 different multilayer polymeric materials for food use, before and after their exposure to gamma radiation, has been assessed by solid-phase microextraction–gas chromatography–mass spectrometry. Thermosealed bags of different materials were filled with either air or nitrogen to evaluate the oxygen influence. One-third of the samples were analyzed without irradiation, whereas the rest were irradiated at 15 and 25 kGy. Half of the samples were processed just after preparation and the other half was stored for 8 months at room temperature prior to analysis. Very significant differences between unirradiated and irradiated bags were found. About 60–80 compounds were released and identified per sample. A huge peak of 1,3-ditertbutylbenzene was present in most of the irradiated samples. An outstanding reproducibility in all the variables evaluated (chromatograms, oxygen percentage, volume of bags) was noticed. Independently of filling gas, the results of unirradiated materials were almost identical. In contrast, the chromatographic profile and the odor of irradiated bags filled with nitrogen were completely different to those filled with air. Principal component analysis was performed and 86.9% of the accumulated variance was explained with the first two components. The migration of compounds from irradiated materials to the vapor phase was much lower than the limits established in the Commission Regulation (EU) No 10/2011.  相似文献   

18.
Summary A simple and sensitive method for the determination of trace amounts of bisphenol-A (BPA), bisphenol-A diglycidyl dimethacrylate (bis-GMA), bisphenol-A dimethacrylate (bis-DMA) and triethyleneglycol dimethacrylate (TEGDMA) in human saliva is proposed. These materials are used in dental restorations, as composites and sealants, and are sometimes detected in human saliva after dental treatment. The proposed method involves protein precipitation using acetonitrile followed by acidification, evaporation of the solvent and dissolution with dichloromethane prior to injection into a GC-MS. Thermal derivatization in the injection system was used for the identification and quantification of bis-GMA. Clean-up is not necessary using SIM mode. Bisphenol-F (BPF) was used as internal standard. The linear range was 15 to 1000 μg·L−1 for BPA, 50 to 10 000 μg·L−1 for bis-GMA, 50 to 1000 μg·L−1 for bis-DMA and 1 to 100 μg·L−1 for TEGDMA. The detection limits were 3,15,10 and 0.3 μg·L−1 for BPA, bis-GMA, bis-DMA and TEGD-MA, respectively. Validation of the proposed method was carried out by using the standard addition methodology. Samples of 10 mL of human saliva collected 1 h after dental treatment were analysed in order to assess the applicability of the method to detect and quantify such compounds originated from methacrylic resins used in odontological treatment.  相似文献   

19.
Summary Fifteen main volatile compounds in ChineseCoriandrum sativum L. were separated and identified by gas chromatography—mass spectrometry (GC-MS) combined with solid-phase microextraction (SPME). Fresh ChineseCoriandrum sativum L. was ground and its volatile compounds were extracted by SPME with a 100 μm polydimethylsiloxane fiber. The fibers were desorbed in a GC injection liner at 250°C for 3 min. More than 15 peaks were separated by headspace SPME-GC-MS analysis. The main compounds in headspace ofCoriandrum sativum L. identified by mass spectrometry included decanal, 2-decenal, 1-decanol,trans-2-decen-1-ol,trans-2-decen-1-al,trans-2-tridecenal etc, which were verified by reference compounds. Their relative contents were calculated on basis of peak areas. SPME extraction conditions and capillary chromatography column used to separate the volatile compounds were investigated.  相似文献   

20.
An optimisation of derivatisation methods for the simultaneous determination of endocrine disrupting chemicals (EDCs) in water by solid-phase extraction (SPE) gas chromatography-mass spectrometry (GC-MS) was developed in this study. Seven highly potent EDCs including 17β-estradiol (E2), estrone (E1), 16α-hydroxyestrone, 17α-ethynylestradiol (EE2), bisphenol A, 4-nonylphenol and 4-tert-octylphenol were selected as the target compounds. The SPE technique, followed by the derivatisation with N,O-bis(trimethylsilyl)trifluoroacetamide (BSTFA) was used for the extraction recoveries of compounds from water and effluent samples. The stability of the silylation derivatives under different reaction conditions was investigated. The combined use of BSTFA and pyridine as derivatisation reagents, together with the use of hexane as the final solvent, was preferred in order to generate more stable derivatives of EDCs. The relative response factor (RRF) of all derivatives except that of EE2 was stable 120 h after derivatisation. The addition of pyridine as derivatisation reagent with BSTFA can prevent the conversion of EE2 to other products during the reaction. Several parameters that may affect the recovery of EDCs, such as the SPE flow rate, and water properties including aquatic colloid content and surfactant concentration were tested. The results showed that the flow rate (1-25 mL min−1), colloid concentration (0-50 mg L−1) and surfactants concentration (0-10 μg L−1) did not cause significant decrease in the EDCs recovery.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号