首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 62 毫秒
1.
2.
A new-multi residue method was developed for the environmental monitoring of 65 stimulants, opiod and morphine derivatives, benzodiazepines, antidepressants, dissociative anaesthetics, drug precursors, human urine indicators and their metabolites in wastewater and surface water. The proposed analytical methodology offers rapid analysis for a large number of compounds, with low limits of quantification and utilises only one solid-phase extraction-ultra performance liquid chromatography-positive electrospray ionisation tandem mass spectrometry (SPE-LC-MS/MS) method, thus overcoming the drawbacks of previously published procedures. The method employed solid phase extraction with the usage of Oasis MCX sorbent and subsequent ultra performance liquid chromatography-positive electrospray ionisation tandem mass spectrometry. The usage of a 1.7 μm particle size column (1 mm×150 mm) resulted in very low flow rates (0.04 mLmin(-1)), and as a consequence gave good sensitivity, low mobile phase consumption and short retention times for all compounds (from 2.9 to 23.1 min). High SPE recoveries (>60%) were obtained for the majority of compounds. The mean correlation coefficients of the calibration curves were typically higher than 0.997 and showed good linearity in the range 0-1000 μgL(-1). The method limits of detection ranged from 0.1 ngL(-1) for compounds including cocaine, benzoylecgonine, norbenzoylecgonine and 2-oxo-3-hydroxy-LSD to 100 ngL(-1) for caffeine. Method quantification limits ranged from 0.5 to 154.2 ngL(-1). Intra- and inter-day repeatabilities were on average less than 10%. The method accuracy range was within -33.1 to 30.1%. The new multi-residue method was used to analyse drugs of abuse in wastewater and river water in the UK environment. Of the targeted 65 compounds, 46 analytes were detected at levels above the method quantification limit (MQL) in wastewater treatment plant (WWTP) influent, 43 in WWTP effluent and 36 compounds in river water.  相似文献   

3.
Benzotriazole UV stabilizers are emerging compounds used in personal care products and can enter surface water after passing through wastewater treatment plants without being removed. Because these analytes are strongly hydrophobic, there is an environmental risk of accumulation in solid matrices and magnification through the trophic chain. In this work, a method based on stir bar sorption extraction with liquid desorption is presented for the extraction of benzotriazole UV stabilizers from water samples. Stir bar sorptive extraction was combined with ultra‐high performance LC with MS/MS detection. All important factors affecting the stir bar sorptive extraction procedure are discussed, and the optimized method was applied to seawater and wastewater samples from Gran Canaria Island, providing good selectivity and sensitivity with LODs and limits of quantification in the range of 18.4–55.1 and 61.5–184 ng/L, respectively. Recoveries between 68.4–92.2% were achieved for the more polar compounds, whereas the recoveries were lower for the two less polar compounds, most likely due to their strong absorption into the polydimethylsiloxane stir bar phase that does not allows the complete desorption. The repeatability studies gave RSDs of between 6.45 and 12.6% for all compounds in the real samples.  相似文献   

4.
A simple and rapid analytical method for the determination of 16 azoles in sewage sludge has been developed and validated. The method was based on ultrasound-assisted extraction followed by dispersive solid-phase extraction cleanup and liquid chromatography-electrospray tandem mass spectrometric detection. The azoles were selected by their intensive usage as biocides (tebuconazole, propiconazole, cyproconazole and thiabendazole), antimycotic pharmaceuticals (ketoconazole, econazole, fluconazole and clotrimazole) or fungicides in agriculture (difenoconazole, flusilazole, hexaconazole, prochloraz, bromuconazole, epoxiconazole and triticonazole). The recoveries of these compounds through the method were between 71.9 and 115.8%, with relative standard deviations lower than 20%. Detection limits were in the range of 0.5-5.0 ng/g. The developed method was applied to the analysis of azoles in sewage sludge samples collected from 19 Spanish wastewater treatment plants. Although azoles used as biocides or agriculture fungicides were present in a few sludge samples, the pharmaceuticals ketoconazole, econazole and clotrimazole were present in all of the analyzed sludge samples, being ketoconazole the one found at the highest level, representing the 68.6% of the total azole content found in the 19 sludge samples studied.  相似文献   

5.
A rapid on-line solid phase extraction ultra high performance liquid chromatography tandem mass spectrometry method was developed for the identification and quantitation of nine perfluorinated compounds in matrices of environmental, biological and food interest. Pre-treatment, solid phase extraction, chromatographic and mass detection conditions were optimised, in order to apply the whole methodology to the analysis of different matrices. Particular attention was devoted to the evaluation of matrix effect and the correlated phenomena of ion enhancement or suppression in mass spectrometry detection. LOD and LOQ range from 3 to 15ngL(-1) and from 10 to 50ngL(-1), respectively. Method detection limits (MDLs) were also calculated for each kind of matrix. The recovery, evaluated for each analyte, does not depend on analyte concentration in the explored concentration range: average Rˉ% values are always greater than 82.9%. In the whole, the results obtained for samples of river waters, blood serum, blood plasma, and fish confirm the ubiquitous presence of perfluorinated compounds, as recently denounced by many sources.  相似文献   

6.
建立了通过式固相萃取-超高效液相色谱-串联质谱测定水产品中地西泮残留量的分析方法。样品用乙腈直接提取,经Prime HLB通过式固相萃取柱(60 mg/3 mL)净化,以Acquity UPLC BEH C18(100 mm×2.1 mm,1.7 μm)为色谱柱,甲醇-0.1%(v/v)甲酸水溶液为流动相进行梯度洗脱。在多反应监测(MRM)、正离子电离模式下检测,采用基质匹配标准曲线外标法进行定量分析。结果显示:在0.1~10 ng/mL范围内,地西泮线性关系良好(r2>0.99)。在1.5、3.0和15.0 μg/kg 3个加标水平下,地西泮的加标回收率为88.2%~101.1%,日间和日内精密度(RSD)均在10%以下。该法简便快速,灵敏度高,可用于水产品中地西泮的准确测定。  相似文献   

7.
Linear alkylbenzene sulphonates (LAS) and polycyclic aromatics hydrocarbons (PAH) are organic pollutants in sewage sludge which will have to be monitored in the European Union according to the third draft of a future sludge directive. In the present work, an analytical method for the simultaneous extraction of 4 LAS homologues and 16 PAH congeners in sludge from wastewater treatment plants is proposed to improve the routine analysis of these compounds in sludge samples. The method involves sonication assisted extraction, clean-up and preconcentration by solid phase extraction, and determination by high-performance liquid chromatography with ultraviolet diode array (UV-DAD) and fluorescence (FLD) detectors. Average recoveries were 87% for LAS and 76% for PAH, with relative standard deviations below 13%. Limits of quantification of LAS and PAH were in the range from 13 to 56 mg kg−1 and from 80 to 650 μg kg−1, respectively, when using UV-DAD. Limits of quantification of LAS and PAH were in the range 5-18 mg kg−1 and from 1 to 150 μg kg−1, respectively, when using FLD. The applicability of the proposed method was evaluated by the determination of these compounds in sludge from wastewater treatment plants in Seville (South Spain).  相似文献   

8.
A simple and sensitive method for simultaneous analysis of 43 pharmaceutical compounds in sewage sludge and sediment samples was developed and validated. The target compounds were extracted using pressurized liquid extraction (PLE) and then purified and pre-concentrated by solid phase extraction (SPE) using a hydrophilic-lipophilic balanced polymer. PLE extraction was performed on temperature of 100 °C, with methanol/water mixture (1/2, v/v) as extraction solvent. The quantitative analysis was performed by liquid chromatography tandem mass spectrometry using a hybrid triple quadrupole-linear ion trap mass spectrometer (LC-QqLIT-MS). Data acquisition was carried out in selected reaction monitoring (SRM) mode, monitoring two SRM transitions to ensure an accurate identification of target compounds in the samples. Additional identification and confirmation of target compounds were performed using the Information Dependent Acquisition (IDA) function. The method was validated through the estimation of the linearity, sensitivity, repeatability, reproducibility and matrix effects. The internal standard approach was used for quantification because it efficiently corrected matrix effects. Despite the strong matrix interferences, the recoveries were generally higher of 50% in both matrixes and the detection and quantification limits were very low. Beside the very good sensitivity provided by LC-QqLIT-MS, an important characteristic of the method is that all the target compounds can be simultaneously extracted, treated and analysed. Hence, it can be used for routine analysis of pharmaceuticals providing large amount of data. The method was applied for the analysis of pharmaceuticals in river sediment and wastewater sludge from three treatment plants with different treatment properties (i.e. capacity, secondary treatment, quality of influent waters). The analysis showed a widespread occurrence of pharmaceuticals in the sludge matrices.  相似文献   

9.
A high‐throughput LC–MS/MS bioanalytical method was developed and validated for the determination of hydrocortisone in mouse serum via supported liquid extraction (SLE) in a 96‐well plate format. Although sample extracts from SLE result in similar matrix effects compared with conventional liquid–liquid extraction (LLE), greater analyte extraction recovery and much higher analysis throughput for the quantitative analysis of hydrocortisone in mouse serum were obtained. The current LC‐MS/MS method was validated for a concentration range of 2.00–2000 ng/mL for hydrocortisone using a 0.100 mL volume of mouse serum. The intra‐ and inter‐day precision and accuracy of the quality control samples at low, medium and high concentration levels showed ≤12.9% CV and ?3.4–6.2% bias for the analyte in mouse serum. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

10.
A fast and novel sample preparation procedure: ultrasound assisted ionic liquid (IL) dispersive liquid extraction for the concentration of lovastatin and simvastatin in aqueous samples was developed. An IL ([C6MIM][PF6]) was used as the extraction solvent, and the factors affecting the extraction efficiency such as initial temperature, the volume of IL, pH of water samples, cooling time, and salt concentration were optimized. In combination with HPLC‐UV, both lovastatin and simvastatin exhibited a good linear range of 1–100 ng/mL. The limits of detection (LODs) of lovastatin and simvastatin were 0.17 and 0.29 ng/mL, respectively. Precisions of the proposed method (RSDs, n = 9) were 4.12 and 4.52%, respectively. This method has been successfully applied for the analysis of target compounds in three real water samples and good spiking recoveries were obtained in the range of 90.0–102.2% for lovastatin and 80.5–112.0% for simvastatin. These results indicated that ultrasound assisted IL dispersive liquid phase extraction would have good application prospect in the pretreatment of environmental samples.  相似文献   

11.
The analysis of a wide range of pesticides in wastewaters (WWs) undergoing different treatments (both modern and conventional) has been studied. The need for optimizing specific extraction methods for each WW effluent based on their physico-chemical characteristics has been considered. A distribution study was performed to establish if the filtration step before extraction is a correct procedure since pesticides can be more prone to be in the aqueous or the solid phase, depending on their hydrophobicity. This evaluation demonstrated that pesticides are distributed between the aqueous phase and the suspended particulate matter (SPM; e.g. pyrethroids are only found in the SPM). The proposed methodologies involved the determination of 39 polar and 139 non-polar pesticides using solid-phase extraction (SPE) and pressurized-liquid extraction (PLE) for the extraction of the aqueous phase and the SPM, respectively. Ultra high pressure liquid chromatography and gas chromatography coupled to tandem mass spectrometry (UHPLC-MS/MS, GC-MS/MS) were used in the determination stage. WW samples from four different technologies were evaluated: membrane bioreactor, extended aeration, maturation pond and anaerobic pond. Validation data for the four effluents studied were generated, obtaining adequate precision values (estimated as % relative standard deviation, RSD) in almost all cases (<25%). The methods showed limits of detection at 0.01-0.20μgL(-1) and limits of quantification from 0.02 to 0.50μgL(-1). The proposed methods were applied to the analysis of real samples collected from an experimental WW treatment plant, detecting non-polar and polar pesticides at concentrations in the range 0.02-1.94μgL(-1) and 0.02-0.33μgL(-1), respectively.  相似文献   

12.
建立了血液中抗抑郁类药物快速筛查的自动固相萃取-液相色谱-飞行时间质谱(ASPE-LC-Q-TOF/MS)方法。样品经HLB固相萃取柱提取后,采用LC-Q-TOF/MS进行测定,外标法定量。结果表明:目标物的线性范围为1~500 μg/L,相关系数为0.9976~0.9997,检出限为0.01~0.5 μg/L。在10、100和500 μg/L 3个添加水平的平均回收率为79.6%~96.4%,相对标准偏差为4.1%~6.4%。利用Agilent MassHunter PCDL Manager软件建立了抗抑郁类药物数据库,并应用于加标样品的筛查分析,本方法能够全部筛查出样品中添加的抗抑郁类药物,鉴定准确度达到100%,且保留时间偏差均小于0.1 min,质量偏差均小于1 mDa,同位素丰度匹配得分、同位素间距得分和MS匹配得分均大于95,MS/MS图谱匹配得分均大于70。利用本方法对实际案例进行筛查分析,检出阿米替林、卡马西平和多虑平,说明该方法可用于法庭与临床毒物分析。  相似文献   

13.
In the present work, an analytical method for the simultaneous determination of five anti-inflammatory drugs (acetaminophen, diclofenac, ibuprofen, ketoprofen and naproxen), an antiepileptic drug (carbamazepine) and a nervous stimulant (caffeine) is proposed for the routine analysis of these pharmaceuticals in wastewater influents and effluents from WWTPs. The method involves pre-concentration and clean-up by solid phase extraction (SPE) using Oasis HLB extraction cartridges. Final analysis of the selected pharmaceutical compounds was carried out by high-performance liquid chromatography (HPLC) with diode array detector (DAD). Confirmation of the presence of the fluorescence compounds (ibuprofen and naproxen) was performed by on-line fluorescence detection. Recoveries were ranged from 71 to 103% with relative standard deviation below 15.1%. Limits of quantification were in the range 6.2–319.8 and 3.0–160.0 ng ml−1 for influent and effluent wastewater samples, respectively. The described method was applied to the determination of the drugs in wastewater samples from four treatment plants in Seville.  相似文献   

14.
邱盼子  郭欣妍  王娜  孔祥吉  何华 《色谱》2015,33(7):722-729
建立了一种同时测定制药废水中3类10种抗生素的超高效液相色谱-串联质谱分析方法。水样用固相萃取柱富集净化,通过比较在不同的固相萃取柱和洗脱液等条件下水样中目标物的回收率,优化了前处理方法。采用Agilent C18色谱柱(75 mm×2.1 mm, 2.7 μm),以0.2%(v/v)甲酸水溶液和乙腈为梯度洗脱的流动相,在电喷雾-多反应监测模式下进行定性定量分析。实验结果表明:在0.1~1000 μg/L范围内,6种氨基糖苷类抗生素、螺旋霉素及3种氟喹诺酮类抗生素的峰面积与质量浓度的线性关系良好(r2 > 0.995),方法检出限为0.07~4.37 ng/L,定量限为0.22~14.55 ng/L;目标抗生素的加标水平为0.002~40 μg/L时,平均回收率为50.4%~114.1%,相对标准偏差均不高于9.89%(n=3)。基于上述方法,对江苏省某制药厂废水中相关物质进行检测,在各废水处理单元中检出3种目标抗生素,质量浓度范围为0.46~1033.60 μg/L。该方法准确可靠、灵敏度高,适用于制药厂废水中氨基糖苷类抗生素、螺旋霉素和氟喹诺酮类抗生素的检测。  相似文献   

15.
The aim of the present work is combination of the advantages of magnetic solid phase extraction (MSPE) and dispersive liquid phase microextraction (DLLME) followed by filtration-based phase separation. A new pretreatment method was developed for trace determination of megestrol acetate and levonorgestrel by liquid chromatography/ultraviolet detection in biological and wastewater samples. After magnetic solid phase extraction, the eluent of MSPE was used as the disperser solvent for DLLME. Emulsion resulted from DLLME procedure was passed through the in-line filter for phase separation. Finally the retained analytes in the filter was washed with mobile phase of liquid chromatography and transferred to the column for separation. This approach offers the preconcentration factors of 3680 and 3750 for megestrol acetate and levonorgestrel, respectively. This guarantees determination of the organic compounds at trace levels. The important parameters influencing the extraction efficiency were studied and optimized. Under the optimal extraction conditions, a linear range of 0.05–50 ng mL−1 (R2 > 0.998) and limit of detection of 0.03 ng mL−1 were obtained for megestrol acetate and levonorgestrel. Under optimal conditions, the method was successfully applied for determination of target analytes in urine and wastewater samples and satisfactory results were obtained (RSDs < 6.8%).  相似文献   

16.
A new method based on pressurized liquid extraction followed by LC‐MS/MS analysis has been developed for the identification and quantification of three capsaicinoids (capsaicin, dihydrocapsaicin, and nordihydrocapsaicin) in extracts of Capsicum annuum. For the recovery of three capsaicinoids, the efficiency levels of ultrasonic‐assisted extraction, microwave‐assisted extraction, Soxhlet extraction, and pressurized liquid extraction were compared under different conditions. Pressurized liquid extraction resulted in higher yields. Pressurized liquid extractions were performed using methanol; temperature was set at 100°C and pressure at 1500 psi. LC analysis was performed on a Waters XBridge? C18 column (150 × 2.1 mm, id 3.5 μm) eluted by a mobile phase of 0.1% formic acid and ACN. Data acquisition was carried out in multiple reaction monitoring transitions mode, monitoring two‐reaction monitoring transitions to ensure an accurate identification of target compounds in the samples. The proposed method is rapid, simple, and could be utilized for the routine analysis of three capsaicinoids in C. annuum samples.  相似文献   

17.
建立了牛肝中5种阿维菌素类药物残留的疏水整体柱在线固相萃取结合高效液相色谱-串联质谱测定的方法。以疏水的聚(甲基丙烯酸丁酯-乙二醇二甲基丙烯酸酯)整体柱(10 mm×2.1 mm)作为固相萃取介质,考察了上样流动相和洗脱流速对阿维菌素类药物的萃取效果,优化了梯度洗脱流动相的种类及质谱条件。方法在1~100 μg/L范围内线性关系良好(r>0.995),定量限为5 μg/kg。在5、10、50、100 μg/kg添加水平的回收率为77.4%~98.4%,日内和日间相对标准偏差分别为4.46%~8.03%和4.79%~8.68%,并且该柱反复使用400次后未发现萃取效率降低。结果表明,该整体柱对牛肝中5种阿维菌素类药物能够有效萃取,并且可以重复使用。该方法简单,自动化程度高,可应用于常规阿维菌素类药物残留分析。  相似文献   

18.
Combining the continuous flow liquid-liquid extraction (CFLLE) and supported liquid membrane (SLM) extraction, a novel aqueous-aqueous extraction technique that we termed continuous flow liquid membrane extraction (CFLME) is developed for trace-enrichment. The analyte was firstly extracted into the organic phase in the CFLLE step, then transported onto the organic liquid membrane that formed on the surface of the micro porous membrane of the SLM equipment. Finally, it passed through the liquid membrane and was trapped by the acceptor. Aspects related to CFLME were studied by using dichloromethane as liquid membrane, and sulfonylurea herbicides as model compounds. An enrichment factor of over 1000 was obtained when 10 μg l−1 of MSM was enriched for 120 min by this technique. The drawbacks of only a few organic solvents can be selected as liquid membrane with a limited lifetime in SLM operation was overcome. In this CFLME method, almost all solvents that used in the conventional liquid-liquid extraction (LLE) can be adopted and the lifetime of liquid membrane is no longer a problem.  相似文献   

19.
An analytical method with two extraction steps has been developed and validated for the simultaneous determination of 30 pharmaceuticals belonging to various therapeutic categories in urban wastewater. The aim was to boost the little available information on drugs' fates in sewage treatment plants (STPs) and in the receiving surface water. Aqueous samples were divided into two aliquots, each extracted by a different solid-phase extraction (SPE) method and analysed by reversed-phase liquid chromatography tandem mass spectrometry (HPLC-MS-MS). Recoveries of the pharmaceuticals were mostly greater than 70% and the overall variability of the method was below 8%. The instrumental quantification limit (IQL) varied between 30 and 400 pg injected, and the limits of quantification (LOQ) were in the low ng/L range. Nineteen pharmaceuticals were detected in concentrations between 0.5 and 2000 ng/L in effluents collected from several STPs in Italy. Atenolol, ciprofloxacin, furosemide, hydrochlorothiazide, ofloxacin, ranitidine and sulphamethoxazole were the most abundant compounds. The present analytical method was useful to check for pharmaceuticals in various Italian STPs and to identify the most abundant compounds.  相似文献   

20.
A method for the quantitative determination of non-steroidal anti-inflammatory drugs (NSAIDs) in sewage sludge was developed and validated. The target compounds were extracted using pressurized hot water extraction (PHWE) and then purified and preconcentrated by three-phase hollow fiber liquid phase microextraction (HF-LPME) followed by LC–ESI-MS analysis. The PHWE was optimized with regard to the pH of solvent as well as other operational parameters. The optimum conditions were 0.01 M NaOH as the extraction solvent, temperature of 120 °C, pressure of 100 bar, static time 5 min, 5 cycles, flush volume 90% and purge time 60 s. Spike recoveries for sludge samples spiked at 200 ng g−1 were in the range of 101–109% but for the native drugs in non-spiked sludge samples, recoveries were 38.9%, 59.8%, 90.3% and 47.8% for ketoprofen, naproxen, diclofenac and ibuprofen, respectively. Donor phase pH, ionic strength and extraction time were optimized for HF-LPME after PHWE. The optimum conditions were 2 h extraction at pH 1.5 without salt addition. Enrichment factors in the range of 947–1213 times were achieved (extraction recoveries were 23.6–30.3%) for HF-LPME after PHWE. The matrix effect on the ionization of drugs in LC–ESI-MS was also investigated. The results show that there is a smaller matrix effect (−8.9% to +14.6%) in comparison with other published values obtained using solid phase extraction (SPE) for clean-up after pressurized liquid extraction (PLE). Method detection limits (MDLs) and method quantification limits (MQLs) for different drugs were in the range of 0.4–3.7 ng g−1 and 1.5–12.2 ng g−1 in dried sludge samples, respectively. The characteristics of the proposed method were compared with those of other published works. The considerably lower ion suppression/enhancement and minimum use of organic solvents (a few microliters of di-n-hexyl ether) in the sample preparation step are two highlighted advantages of the proposed method in comparison with previously published works. The method was applied to determine NSAIDs in sewage sludge from Källby wastewater treatment plant (Lund, Sweden) in April, June, August and October 2010. The highest concentration level was recorded for ibuprofen in the April sewage sludge sample (588 ng g−1) and all of the selected NSAIDs were detected in all the samples analyzed.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏