首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 78 毫秒
1.
In the present study, an RP high performance liquid chromatographic method was developed and validated for the determination of allicin in garlic powder and tablets. Chromatographic separation was carried out on an RP-18(e )column (125 mm x 4 mm), using a mobile phase, consisting of methanol-water (50:50 v/v), at a flow rate of 0.5 mL/min and UV detection at 220 nm. Ethylparaben was used as the internal standard. The assay was linear for allicin concentrations of 5.0-60.0 microg/mL. The RSD for precision was <6.14%. The accuracy was above 89.11%. The detection and quantification limits were 0.27 and 0.81 microg/mL, respectively. This method was used to quantify allicin in garlic powder samples. The results showed that the method described here is useful for the determination of allicin in garlic powder and tablets.  相似文献   

2.
A high-performance liquid chromatographic method with UV detection has been developed for the determination of saikosaponin a in rat plasma. Saikosaponin a and internal standard jujuboside A were isolated from plasma samples by solid-phase extraction. The chromatographic separation was achieved on a reversed-phase C(18) column with the mobile phase of acetonitrile-water (35:65, v/v) at a flow rate of 1 mL/min and UV detection was set at 205 nm. The standard curve for saikosaponin a was linear over the concentration range 0.25-10 microg/mL and the limit of detection was 0.05 microg/mL. The absolute recovery was greater than 82%. The precision and accuracy ranged from 3.05 to 9.59% and 95.61 to 110.00%, respectively. The validated method was used to determine saikosaponin a in plasma samples in a pharmacokinetic study of saikosaponin a administered to Sprague-Dawley rats.  相似文献   

3.
A rapid, simple, and sensitive RP-HPLC analytical method was developed for the simultaneous determination of triclabendazole and ivermectin in combination using a C18 RP column. The mobile phase was acetonitrile-methanol-water-acetic acid (56 + 36 + 7.5 + 0.5, v/v/v/v) at a pH of 4.35 and flow rate of 1.0 mL/min. A 245 nm UV detection wavelength was used. Complete validation, including linearity, accuracy, recovery, LOD, LOQ, precision, robustness, stability, and peak purity, was performed. The calibration curve was linear over the range 50.09-150.26 microg/mL for triclabendazole with r = 0.9999 and 27.01-81.02 microg/mL for ivermectin with r = 0.9999. Calculated LOD and LOQ for triclabendazole were 0.03 and 0.08 microg/mL, respectively, and for ivermectin 0.07 and 0.20 microg/mL, respectively. The intraday precision obtained was 98.71% with RSD of 0.87% for triclabendazole and 100.79% with RSD 0.73% for ivermectin. The interday precision obtained was 99.51% with RSD of 0.35% for triclabendazole and 100.55% with RSD of 0.59% for ivermectin. Robustness was also studied, and there was no significant variation of the system suitability of the analytical method with small changes in experimental parameters.  相似文献   

4.
To analyze unbound cefamandole in rat blood, a method combing microdialysis with microbore liquid chromatography has been developed. A microdialysis probe was inserted into the jugular vein/right atrium of male Sprague-Dawley rats to examine the unbound cefamandole level in the rat blood following cefamandole administration (50 mg/kg, i.v.). The dialysates were directly submitted to a liquid chromatographic system. Samples were eluted with a mobile phase containing acetonitrile-methanol-100 mM monosodium phosphate (pH 5.0; 15:20:65, v/v). The UV wavelength was set at 270 nm for monitoring the analyte. Using the retrograde method, at infusion concentrations of 1 microg/mL of cefamandole, the in vivo microdialysis recoveries were 55.44% for the rat blood (n = 6). Intra- and inter-assay accuracy and precision of the analyses were < or = 10% in the range of 0.1-10 microg/mL. Pharmacokinetic parameters were calculated from the recovery-corrected dialysate concentrations of cefamandole vs time data. The elimination half-life (t1/2,beta) was 21.6 +/- 1.6 min. The results suggest that the pharmacokinetics of unbound cefamandole in blood following cefamandole administration (50 mg/kg, i.v., n = 5) fit best to the two-compartmental model.  相似文献   

5.
A validated reversed-phase high-performance liquid chromatographic (RP-HPLC) method was developed for the determination of bergenin in rat plasma. Bergenin in rat plasma was extracted with methanol, which also acted as a deproteinization agent. Chromatographic separation of bergenin was performed on a C(18) column, with a mobile phase of methanol-water (22:78, v/v) at a flow-rate of 0.8 mL/min and an operating temperature of 40 degrees C, and UV detection was set at 220 nm. The calibration curve was linear over the range 0.25-50 microg/mL (r = 0.9990) in rat plasma. The limit of quantification was 0.25 microg/mL using a plasma sample of 100 microL. The extraction recoveries were 83.40 +/- 6.02, 81.49 +/- 2.40 and 72.51 +/- 2.64% at concentrations of 0.5, 5 and 50 microg/mL, respectively. The intra-day and inter-day precision and accuracy were validated by relative standard deviation (RSD%) and relative error (RE%), which were in the ranges 3.74-9.91 and -1.6-8.0%. After intravenous administration to rats at the dose of 11.25 mg/kg, the plasma concentration-time curve of bergenin was best conformed to a two-compartment open model. The main pharmacokinetic parameters indicated that bergenin exhibited a wide distribution and moderate elimination velocity in rat.  相似文献   

6.
Dimethyl benzoylphenyl urea (BPU) inhibited tubulin polymerization, caused microtubule depolymerization in vitro and demonstrated activity against solid tumors. BPU is being tested in phase I clinical trials. A rapid and specific method using LC/UV has been developed for quantitation of BPU in human heparin-containing plasma to perform pharmacokinetic and pharmacodynamic studies. BPU is extracted from plasma into acetonitrile:n-butyl-chloride using paclitaxel as the internal standard and separated on a Waters Symmetry C18 (3.9 x 150 mm, 5 microm) column with acetonitrile-water mobile phase (70:30, v/v) using isocratic flow at 1 mL/min for a run time of 5 min. Ultraviolet detection was utilized and performed at 225 nm for BPU and paclitaxel. The retention times were 1.9 min for paclitaxel and 4.1 min for BPU. Calibration curves were generated over the range of 0.01-10 microg/mL with coefficient of determination of > 0.99. The values for within-day and between-day precision were < or = 17.0% at the LLOQ and < or = 7.4% at the low, medium and high quality controls; accuracy was +/- 5.4%. Following administration of BPU 320 mg as a weekly oral dose to a patient with advanced solid tumor malignancies, the maximum plasma concentration was 2 micro g/mL and concentrations were quantifiable up to 168 h after administration. The lower limit of quantitation of 0.01 microg/mL allows for successful measurement of plasma concentrations in patients.  相似文献   

7.
A simple, sensitive and selective RP-HPLC method has been developed for quantification of nodakenin in rat plasma. Nodakenin in rat plasma was extracted with acetonitrile, which also acted as a deproteinization agent. Chromatographic separation of nodakenin was performed on an analytical Diamonsil ODS C18 column, with a mobile phase of MeOH-H2O (1:1, v/v) at a flow-rate of 1.0 mL/min, and UV detection was set at 330 nm. The calibration curve was linear over the range 0.2-12.0 microg/mL (R2 = 0.9995) in rat plasma. The lower limit of detection and quantification were 0.01 and 0.1 microg/mL, respectively, using the rat plasma sample. The extraction recoveries were 77.36 +/- 4.56, 82.89 +/- 1.84 and 81.66 +/- 2.49% at concentrations of 1.0, 5.0 and 10.0 microg/mL, respectively. The intra- and inter-day precision and accuracy were validated by relative standard deviation and relative error, which were in the ranges 5.07-5.83 and 3.95-6.29%, respectively. After i.v. administration to rats at a single dose of 40 mg/kg, the plasma concentration-time curve of nodakenin was best conformed to a two-compartment open model. This assay method has been successfully applied to the study of the pharmacokinetics of nodakenin in rats.  相似文献   

8.
A precise, accurate, and sensitive UV spectrophotometric method was developed and validated for routine quantification of total bioflavonoids, expressed as rutin, from a topical oil-in-water pharmaceutical emulsion containing the extract of Trichilia catigua Adr. Juss and Ptychopetalum olacoides Bentham. The method was validated experimentally, and the data were treated rigorously by statistical analysis. The following analytical parameters were assessed: linearity, specificity, intra- and interrun precision measured as relative standard deviation (RSD, %), intra- and interrun accuracy (E, %), recovery (Rec., %), limit of detection (LOD, microg/mL), and limit of quantification (LOQ, microg/mL). The UV spectrophotometric method was linear (r = 0.9995) for standard rutin over the concentration range of 5.0-15.0 microg/mL with specificity for total bioflavonoids (expressed as rutin) at 361.0 nm with an absence of interferents from the complex matrix; RSD of < or = 1.79%, intrarun (E = 97.88 +/- 1.75 to 99.0 +/- 0.33%) and interrun (E = 98.38 +/- 1.12 to 100.79 +/- 1.30%) accuracy; Rec. = 98.64 +/- 0.42 to 100.74 +/- 0.41%; LOD = 0.20 microg/mL; and LOQ = 0.30 microg/mL.  相似文献   

9.
Column high-performance liquid chromatographic (LC) and UV spectrophotometric methods for the quantitative determination of citalopram, a potent and selective serotonin reuptake inhibitor, in tablets were developed. The parameters linearity, precision, accuracy, specificity, robustness, limit of detection, and limit of quantitation were studied according to International Conference on Harmonization guidelines. Chromatography was carried out by the reversed-phase technique on an ACE C18 column with a mobile phase composed of 0.30% triethylamine solution-acetonitrile (55 + 45, v/v) adjusted to pH 6.6 with 10% ortho-phosphoric acid at a flow rate of 1.0 mL/min and 25 degrees C. The UV spectrophotometric method was performed at 239 nm. The linearity of the LC method was in the range of 10.00-70.00 microg/mL, and 2.50-17.50 microg/mL for the UV spectrophotometric method. The interday and intraday assay precision was < 1.5% (relative standard deviation) for the LC and UV spectrophotometric methods. The recoveries were in the range 100.70-101.35% for the LC method and 98.48-98.65% for the UV spectrophotometric method. Statistical analysis by Student's t-test showed no significant difference between the results obtained by the 2 methods. The proposed methods are highly sensitive, precise, and accurate and can be used for the reliable quantitation of citalopram in tablets.  相似文献   

10.
Lan J  Hu J  Li B  Xing D  Liu C  Wang W  Du L 《Biomedical chromatography : BMC》2008,22(11):1201-1205
Quantification of brazilein in rat plasma following intravenous administration was achieved by reversed-phase high-performance liquid chromatography using a mobile phase of acetonitrile-0.05 m potassium dihydrogen phosphate water (containing 0.5% triethylamine, pH 3.0; 20:80 v/v) and UV detection at 445 nm. The method was linear (determination coefficient, r(2) = 0.9992) within the tested range (0.313-5.0 microg/mL). Intra- and inter-day precision coefficients of variation and accuracy bias were acceptable (maximal CV value was 2.06% for intra-day and 1.71% for inter-day) over the entire range. The recoveries were 81.48, 84.61 and 82.83% for concentrations of 0.313, 1.25 and 5.0 microg/mL, respectively. The concentration-time curve of brazilein after intravenous administration was fitted to the two-compartment model. This is the first time that brazilein in rat plasma was detected by HPLC-UV method and its pharmacokinetic characteristic was comprehensively studied.  相似文献   

11.
A microemulsion electrokinetic chromatography (MEEKC) method has been developed and validated for the determination of folic acid, a water-soluble vitamin, in a commercial tablet formulation. The analysis was performed using a microemulsion containing 0.5% (w/w) ethyl acetate, 1.2% (w/w) butan-1-ol, 0.6% (w/w) sodium dodecyl sulfate, 15% (v/v) 2-propanol and 82.7% (w/w) 10 mmol L(-1) sodium tetraborate aqueous buffer at pH 9.2. Direct UV detection at 214nm led to an adequate sensitivity without interference from sample excipients. For quantitative purposes, niacin was used as internal standard. Acceptable precision (<1.2% relative standard deviation (R.S.D.)), linearity (r = 0.9992; range from 160.0 to 240.0 microg/mL), sensitivity (limit of detection (LOD) = 2.98 microg/mL; limit of quantification (LOQ) = 9.05 microg/mL) and recovery (99.8 +/- 1.8% at three concentration levels) were obtained. Based on the performance characteristics, the proposed methodology was found suitable for the determination of folic acid in tablet formulations.  相似文献   

12.
An accurate, simple, reproducible, and sensitive HPLC method was developed and validated for the simultaneous determination of atorvastatin calcium, ezetimibe, and fenofibrate in a tablet formulation. The analyses were performed on an RP C18 column, 150 x 4.60 mm id, 5 pm particle size. The mobile phase methanol-acetonitrile-water (76 + 13 + 11, v/v/v), was pumped at a constant flow rate of 1 mL/min. UV detection was performed at 253 nm. Retention times of atorvastatin calcium, ezetimibe, and fenofibrate were found to be 2.25, 3.68, and 6.41 min, respectively. The method was validated in terms of linearity, precision, accuracy, LOD, LOQ, and robustness. The response was linear in the range 2-10 microg/mL (r2 = 0.998) for atorvastatin calcium, 2-10 microg/mL (r2 = 0.998) for ezetimibe, and 40-120 microg/mL (r2 = 0.998) for fenofibrate. The developed method can be used for routine quality analysis of the drugs in the tablet formulation.  相似文献   

13.
Quantification of p-coumaric acid in mouse plasma following oral administration of Ananas comosus L. leaves was achieved by reversed-phase high-performance liquid chromatography using a mobile phase of water-acetonitrile (82:18, v/v) and UV detection at 310 nm. The method was linear (determination coefficient, r2 = 0.9997) within the tested range (0.04-1.28 microg/mL). Intra- and inter-day precision coefficients of variation and accuracy bias were acceptable (maximal CV value was 4.06% for intra-day and 4.19% for inter-day) over the entire range. The recoveries were 90.63, 97.98 and 100.01% for concentrations of 0.04, 0.32 and 1.28 microg/mL, respectively. This is a very rapid, sensitive and economical way to determine p-coumaric acid concentration in mouse plasma after oral administration of A. comosus leaves. The concentration-time curve was fitted to the one-compartment model. This is the first time that p-coumaric acid extracted from A. comosus leaves was detected by HPLC-UV method and its pharmacokinetic characteristic was comprehensively studied.  相似文献   

14.
Abstract

A sensitive, specific, qualitative, and quantitative extraction procedure followed by an hplc assay of 11-nor-Δ-9-tetrahydrocannabinol-9-carboxylic acid (THC-COOH) from human urine is developed. Using a new, “mixed mode”, bonded silica gel solid phase extraction (SPE) column, the analyte was selectively isolated from the urine component. Following extraction, the presence of THC-COOH was confirmed and quantitated by a UV detector on a Varian 15cm C18 column using 35:65 v/v 50 mM phosphoric acid:acetonitrile at a flow rate of 1.5 mL/min. The limit of detection was 10 ng/mL at a signal to noise ratio of 2.5. The method showed linearity in the 10–300 ng/mL range (r=0.999) with good precision (RSD 1.4%) and accuracy (87% absolute recovery).  相似文献   

15.
Two high-performance liquid chromatographic methods for determination of residual monomer in dental acrylic resins are described. Monomers were detected by their UV absorbance at 230 nm, on a Nucleosil C18 (5 microm particle size, 100 A pore size, 15 x 0.46 cm i.d.) column. The separation was performed using acetonitrile-water (55:45 v/v) containing 0.01% triethylamine (TEA) for methyl methacrylate and butyl methacrylate, and acetonitrile-water (60:40 v/v) containing 0.01% TEA for isobutyl methacrylate and 1,6-hexanediol dimethacrylate as mobile phases, at a flow rate of 0.8 mL/min. Good linear relationships were obtained in the concentration range 5.0-80.0 microg/mL for methyl methacrylate, 10.0-160.0 microg/mL for butyl methacrylate, 50.0-500.0 microg/mL for isobutyl methacrylate and 2.5-180.0 microg/mL for 1,6-hexanediol dimethacrylate. Adequate assay for intra- and inter-day precision and accuracy was observed during the validation process. An extraction procedure to remove residual monomer from the acrylic resins was also established. Residual monomer was obtained from broken specimens of acrylic disks using methanol as extraction solvent for 2 h in an ice-bath. The developed methods and the extraction procedure were applied to dental acrylic resins, tested with or without post-polymerization treatments, and proved to be accurate and precise for the determination of residual monomer content of the materials evaluated.  相似文献   

16.
An ultraviolet spectrophotometric method was validated for total flavonoid quantitation, as rutin equivalents, present in the Trichilia catigua Adr. Juss (Meliaceae) and Ptychopetalum olacoides Bentham (Olacaceae) commercial extract. Parameters as linearity, interval (range), specificity, estimated limit of detection (LOD, microg/mL), estimated limit of quantitation (LOQ, microg/mL), recovery (R, %), precision or relative standard deviation (RSD, %), and accuracy (E, %) were established. The analytical method was validated according to the experimental results: correlation coefficient (r = 0.9997); interval (RSD = 0.15-0.47%; E = 98.98-101.24%); specificity to total flavonoids quantitation, as rutin equivalents, at wavelength 361.0 nm; LOD = 0.09 microg/mL and LOQ = 0.27 microg/mL; R = 99.36-102.14%; adequate intra- and interrun precision (0.30-0.49% and 0.31-0.81%), and intra- and interrun accuracy (100.60-102.38% and 98.58-100.38%).  相似文献   

17.
A new HPLC method for the determination of geniposide in rat serum with solid-phase extraction (SPE) for preconcentration is described. Geniposide and an internal standard (paeoniflorin) were extracted from serum by SPE using C18 cartridges. Analysis of the extract was then performed on a reversed-phase C18 column using acetonitrile-water (16:84, v/v) as the eluting solvent system, and UV detection at 238 nm was used to measure the analyte with a limit of quantitation about 0.1 microg/mL. The calibration curve for geniposide was linear (r = 0.9993) in the concentration range 0.1-16.0 microg/mL. The intra- and inter-day precision of the geniposide were determined and their RSD did not exceed 10%. The validated method has been successfully applied for pharmacokinetic studies of geniposide from rat serum after oral administration of Yin-Zhi-Ku decoction.  相似文献   

18.
A high performance liquid chromatographic method (HPLC), together with solid phase extraction (SPE), was developed for simultaneous determination of albiflorin and paeoniflorin in rat urine after oral administration of Si-Wu decoction. The samples were pretreated with solid phase extraction using Extract-Cleantrade mark cartridges. Analysis of the extract was performed on a reversed-phase C18 column and a mobile phase made up of acetonitrile and 0.03% formic acid (17:83, v/v). UV detection was set at 230 nm. The assay was linear over the range 2.625-52.50 mg/mL for albiflorin and 3.875-77.50 microg/mL for paeoniflorin. The average percentage recoveries of three spiked urines were 97.01 +/- 3.32 and 102.32 +/- 6.97 for albiflorin and paeoniflorin, respectively. The intra-day precision (RSD) ranged from 0.21 to 1.79% at concentrations of 4.20, 10.50, 26.25 and 39.375 microg/mL of albiflorin and 0.12 to 2.92% at concentrations of 3.875, 10.85, 23.25 and 58.125 microg/mL of paeoniflorin, and inter-day precision (RSD) was from 1.02 to 1.86% for albiflorin and 0.94 to 3.30% for paeoniflorin, at the same four concentrations. This method was applied in order to analyze albiflorin and paeoniflorin in rat urine following oral administration of traditional Chinese medicinal preparation of Si-Wu decoction.  相似文献   

19.
A rapid and simple high-performance liquid chromatographic method for the analysis of 1,3-dihydroxy-2-methylxanthone (DHMXAN) in biodegradable poly(D,L-lactide-co-glycolide) (PLGA) nanosphere and nanocapsule formulations is developed and validated. The method does not require any complex sample extraction procedure. Chromatographic separation is made with a reversed-phase C18 column, using methanol-water (90:10, v/v) containing 1% (v/v) acetic acid as a mobile phase at a flow rate of 1 mL/min. Identification is made by UV detection at 237 nm. The isocratic system operates at ambient temperature and requires 7.5 min of chromatographic time. The developed method is statistically validated according to ICH guidelines and USP 29 for its specificity, linearity, accuracy, and precision. The assay method proposed in this study is specific for DHMXAN in the presence of nanosphere and nanocapsule excipients. Diode-array analyses confirm the purity of DHMXAN peak in stress conditions (> 99.0%). The method is shown to be linear (r > or = 0.999) over the concentration range of 0.25-3.0 microg/mL. Recovery ranges from 99.0% to 102.7% (RSD: 1.49%) and from 98.3% to 101.6% (RSD: 1.07%) for nanospheres and nanocapsules, respectively. Repeatability (intra-assay precision) and intermediate precision is acceptable with RSD values ranging from 0.6% to 1.9% and from 0.3% to 2.0%, respectively. The method is shown to be suitable for the evaluation of DHMXAN content entrapped in PLGA nanoparticles.  相似文献   

20.
A simple and sensitive high-performance liquid chromatography (HPLC) method has been developed for the determination of chlorogenic acid (3-O-caffeoyl-D-quinic acid) in plasma and applied to its pharmacokinetic study in rabbits after administration of Flos Lonicerae extract. Plasma samples are extracted with methanol. HPLC analysis of the extracts is performed on a C(18) reversed-phase column using acetonitrile-0.2% phosphate buffer (11:89, v/v) as the mobile phase. The UV detector is set at 327 nm. The standard curves are linear in the range 0.0500-1.00 microg/mL (r = 0.9987). The mean extraction recovery of 85.1% is obtained for chlorogenic acid. The interday precision (relative standard deviation) ranges from 5.0% to 7.5%, and the intraday precision is better than 9.0%. The limit of quantitation is 0.0500 microg/mL. The plasma concentration of chlorogenic acid shows a C(max) of 0.839 +/- 0.35 microg/mL at 34.7 +/- 1.1 min and a second one of 0.367 +/- 0.16 microg/mL at 273.4 +/- 39.6 min.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号