首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A silicon microcantilever sensor was developed for the detection of Escherichia coli O157:H7. The microcantilever was modified by anti-E. coli O157:H7 antibodies on the silicon surface of the cantilever. When the aquaria E. coli O157:H7 positive sample is injected into the fluid cell where the microcantilever is held, the microcantilever bends upon the recognition of the E. coli O157:H7 antigen by the antibodies on the surface of the microcantilever. A negative control sample that does not contain E. coli O157:H7 antigen did not cause any bending of the microcantilever. The detection limit of the sensor was 1 x 10(6) cfu/mL when the assay time was < 2 h.  相似文献   

2.
He X  Zhou L  He D  Wang K  Cao J 《The Analyst》2011,136(20):4183-4191
A novel, fast and sensitive determination strategy for E. coli O157:H7 has been developed by combination of ligandmagnetic nanoparticles (LMNPs) enrichment with a fluorescent silica nanoparticles (FSiNPs) based two-color flow cytometry assay (LMNPs@FSiNPs-FCM). E. coli O157:H7 was first captured and enriched through the lectin concanavalin A (Con A) favored strong adhesion of E. coli O157:H7 to the mannose-conjugated magnetic nanoparticles. The enriched E. coli O157:H7 was further specially labeled with goat anti-E. coli O157:H7 antibody modified RuBpy-doped FSiNPs, and then stained with a nucleic acid dye SYBR Green I (SYBR-I). After dual-labeling with FSiNPs and SYBR-I, the enriched E. coli O157:H7 was determined using multiparameter FCM analysis. With this method, the detection sensitivity was greatly improved due to the LMNPs enrichment and the signal amplification of the FSiNPs labelling method. Furthermore, the false positives caused by aggregates of FSiNPs conjugates and nonspecific binding of FSiNPs to background debris could be significantly decreased. This assay allowed the detection of E. coli O157:H7 in PB buffer at levels as low as 7 cells mL(-1). The total assay time including E. coli O157:H7 sample enrichment and detection was less than 4 h. An artificially contaminated bottled mineral water sample with a concentration of 6 cells mL(-1) can be detected by this method. It is believed that the proposed method will find wide applications in biomedical fields demanding higher sensitive bacterial identification.  相似文献   

3.
将免疫荧光纳米标记技术与激光共聚焦显微成像方法相结合,发展了一种基于二氧化硅荧光纳米颗粒和核酸染料SYBR Green Ⅰ的双色显微成像技术用于大肠杆菌O157:H7的检测.采用联吡啶钌(RuBpy)二氧化硅荧光纳米颗粒对羊抗大肠杆菌O157:H7抗体进行修饰,基于抗体-抗原相互作用实现了其对目标大肠杆菌O157:H7...  相似文献   

4.
将金纳米粒子(AuNPs)标记的大肠杆菌O157∶H7(E.coli O157∶H7)的多克隆抗体(PAb)作为二抗,采用氨基偶联法将PAb固定在传感器表面作为一抗,通过三明治方法用双通道表面等离子体子共振(SPR)传感器对E.coli O157∶H7进行检测,并与SPR直接法检测进行了比较.结果表明,直接法的检出限为103cfu/mL,线性范围为103~109cfu/mL;AuNPs增强三明治法的检出限为10 cfu/mL,线性范围为10~1010cfu/mL,灵敏度比直接法提高了100倍,且具有更宽的检测范围.本方法不仅检测时间短,而且具有良好的选择性和重现性.  相似文献   

5.
Zhu H  Sikora U  Ozcan A 《The Analyst》2012,137(11):2541-2544
We report a cell-phone based Escherichia coli (E. coli) detection platform for screening of liquid samples. In this compact and cost-effective design attached to a cell-phone, we utilize anti-E. coli O157:H7 antibody functionalized glass capillaries as solid substrates to perform a quantum dot based sandwich assay for specific detection of E. coli O157:H7 in liquid samples. Using battery-powered inexpensive light-emitting-diodes (LEDs) we excite/pump these labelled E. coli particles captured on the capillary surface, where the emission from the quantum dots is then imaged using the cell-phone camera unit through an additional lens that is inserted between the capillary and the cell-phone. By quantifying the fluorescent light emission from each capillary tube, the concentration of E. coli in the sample is determined. We experimentally confirmed the detection limit of this cell-phone based fluorescent imaging and sensing platform as ~5 to 10 cfu mL(-1) in buffer solution. We also tested the specificity of this E. coli detection platform by spiking samples with different species (e.g., Salmonella) to confirm that non-specific binding/detection is negligible. We further demonstrated the proof-of-concept of our approach in a complex food matrix, e.g., fat-free milk, where a similar detection limit of ~5 to 10 cfu mL(-1) was achieved despite challenges associated with the density of proteins that exist in milk. Our results reveal the promising potential of this cell-phone enabled field-portable and cost-effective E. coli detection platform for e.g., screening of water and food samples even in resource limited environments. The presented platform can also be applicable to other pathogens of interest through the use of different antibodies.  相似文献   

6.
利用伴刀豆球蛋白A(Con A)的多价结合能力, 结合水凝胶技术与核酸染色技术发展了一种基于甘露糖功能化的水凝胶检测大肠杆菌(E.coli)O157: H7的方法. 以过硫酸铵(APS)为催化剂, 四甲基乙二胺(TEMED)为加速剂, 用丙烯酰胺(AAm)、N,N-二甲基双丙烯酰胺和N-丙烯酰氧琥珀酰亚胺(NAS)合成水凝胶, 通过氨基化甘露糖与NAS发生交联反应, 制备了甘露糖功能化的水凝胶. 当甘露糖功能化的水凝胶加入与Con A共孵育后的菌悬液中时, 由于Con A既能与甘露糖特异性结合, 又能与E.coli O157: H7表面的O-抗原发生免疫反应而紧密连接, 使目标菌被捕获到水凝胶表面, 采用核酸染料SYBR Green Ⅰ对捕获细菌进行染色, 实现了对E.coli O157: H7的核酸标记, 最后通过活体荧光成像系统对水凝胶进行荧光成像, 从而实现对待测样品的检测. 研究结果表明, 该方法可应用于缓冲液体系和混合细菌样品中E.coli O157: H7的特异性检测, 且整个检测步骤包括样品预处理可在2 h内完成. 该方法成本低、易操作, 且具有较好的灵敏度, 可检出3.7×101 Cells/mL的目标细菌样品.  相似文献   

7.
Varshney M  Li Y 《Talanta》2008,74(4):518-525
Double interdigitated array microelectrodes (IAM)-based flow cell was developed for an impedance biosensor to detect viable Escherichia coli O157:H7 cells after enrichment in a growth medium. This study was aimed at the design of a simple flow cell with embedded IAM which does not require complex microfabrication techniques and can be used repeatedly with a simple assembly/disassembly step. The flow cell was also unique in having two IAM chips on both top and bottom surfaces of the flow cell, which enhances the sensitivity of the impedance measurement. E. coli O157:H7 cells were grown in a low conductivity yeast-peptone-lactose-TMAO (YPLT) medium outside the flow cell. After bacterial growth, impedance was measured inside the flow cell. Equivalent circuit analysis indicated that the impedance change caused by bacterial growth was due to double layer capacitance and bulk medium resistance. Both parameters were a function of ionic concentration in the medium, which increased during bacterial growth due to the conversion of weakly charged substances present in the medium into highly charged ions. The impedance biosensor successfully detected E. coli O157:H7 in a range from 8.0 to 8.2x10(8)CFUmL(-1) after an enrichment growth of 14.7 and 0.8h, respectively. A logarithmic linear relationship between detection time (T(D)) in h and initial cell concentration (N(0)) in CFUmL(-1) was T(D)=-1.73logN(0)+14.62, with R(2)=0.93. Double IAM-based flow cell was more sensitive than single IAM-based flow cell in the detection of E. coli O157:H7 with 37-61% more impedance change for the frequency from 10Hz to 1MHz. The double IAM-based flow cell can be used to design a simple impedance biosensor for the sensitive detection of bacterial growth and their metabolites.  相似文献   

8.
Z Zhu  W Zhang  X Leng  M Zhang  Z Guan  J Lu  CJ Yang 《Lab on a chip》2012,12(20):3907-3913
Genetic alternations can serve as highly specific biomarkers to distinguish fatal bacteria or cancer cells from their normal counterparts. However, these mutations normally exist in very rare amount in the presence of a large excess of non-mutated analogs. Taking the notorious pathogen E. coli O157:H7 as the target analyte, we have developed an agarose droplet-based microfluidic ePCR method for highly sensitive, specific and quantitative detection of rare pathogens in the high background of normal bacteria. Massively parallel singleplex and multiplex PCR at the single-cell level in agarose droplets have been successfully established. Moreover, we challenged the system with rare pathogen detection and realized the sensitive and quantitative analysis of a single E. coli O157:H7 cell in the high background of 100?000 excess normal K12 cells. For the first time, we demonstrated rare pathogen detection through agarose droplet microfluidic ePCR. Such a multiplex single-cell agarose droplet amplification method enables ultra-high throughput and multi-parameter genetic analysis of large population of cells at the single-cell level to uncover the stochastic variations in biological systems.  相似文献   

9.
The Visual Immunoprecipitate (VIP) for the Detection of E. coli O157:H7 in Foods, AOAC Official Method 996.09, has been modified to use a simplified plastic housing for the device. A methods comparison study was conducted to demonstrate the equivalence of this modification to the reference culture method. Three foods were analyzed. In total, valid results were obtained from 240 samples and controls. Results showed that the VIP for E. coli O157:H7 is equivalent to the reference culture methods for the detection of E. coli O157:H7.  相似文献   

10.
Yang L  Li Y 《The Analyst》2006,131(3):394-401
In this study, we explored the use of semiconductor quantum dots (QDs) as fluorescence labels in immunoassays for simultaneous detection of two species of foodborne pathogenic bacteria, Escherichia coli O157:H7 and Salmonella Typhimurium. QDs with different sizes can be excited with a single wavelength of light, resulting in different emission peaks that can be measured simultaneously. Highly fluorescent semiconductor quantum dots with different emission wavelengths (525 nm and 705 nm) were conjugated to anti-E. coli O157 and anti-Salmonella antibodies, respectively. Target bacteria were separated from samples by using specific antibody coated magnetic beads. The bead-cell complexes reacted with QD-antibody conjugates to form bead-cell-QD complexes. Fluorescent microscopic images of QD labeled E. coli and Salmonella cells demonstrated that QD-antibody conjugates could evenly and completely attach to the surface of bacterial cells, indicating that the conjugated QD molecules still retain their effective fluorescence, while the conjugated antibody molecules remain active and are able to recognize their specific target bacteria in a complex mixture. The intensities of fluorescence emission peaks at 525 nm and 705 nm of the final complexes were measured for quantitative detection of E. coli O157:H7 and S. Typhimurium simultaneously. The fluorescence intensity (FI) as a function of cell number (N) was found for Salmonella and E. coli, respectively. The regression models can be expressed as: FI = 60.6 log N- 250.9 with R(2) = 0.97 for S. Typhimurium, and FI = 77.8 log N- 245.2 with R(2) = 0.91 for E. coli O157:H7 in the range of cell numbers from 10(4) to 10(7) cfu ml(-1). The detection limit of this method was 10(4) cfu ml(-1). The detection could be completed within 2 hours. The principle of this method could be extended to detect multiple species of bacteria (3-4 species) simultaneously, depending on the availability of each type of QD-antibody conjugates with a unique emission peak and the antibody coated magnetic beads specific to each species of bacteria.  相似文献   

11.
A diagnostic polymerase chain reaction assay was developed for the detection of E. coli O157 as the first part of a multicenter validation and standardization project. The assay is based on amplification of sequences of the rfbE O157 gene and includes an internal amplification control. The selectivity of the assay was evaluated against 155 strains, including 32 E. coli O157, 38 E. coli non-O157, and 85 non-E. coli. It was shown to be highly inclusive (100%) and exclusive (100%). The assay has a 100% detection probability of approximately 2 x 10(3) cells per reaction.  相似文献   

12.
A MEMS‐based impedance biosensor was designed, fabricated, and tested to effectively detect the presence of bacterial cells including E. coli O157:H7 and Salmonella typhimurium in raw chicken products using detection region made of multiple interdigitated electrode arrays. A positive dielectrophoresis based focusing electrode was used in order to focus and concentrate the bacterial cells at the centerline of the fluidic microchannel and direct them toward the detection microchannel. The biosensor was fabricated using surface micromachining technology on a glass substrate. The results demonstrate that the device can detect Salmonella with concentrations as low as 10 cells/mL in less than 1 h. The device sensitivity was improved by the addition of the focusing electrodes, which increased the signal response by a factor between 6 and 18 times higher than without the use of the focusing electrodes. The biosensor is selective and can detect other types of pathogen by changing the type of the antibody immobilized on the detection electrodes. The device was able to differentiate live from dead bacteria.  相似文献   

13.
《Analytical letters》2012,45(5):874-884
An immunoassay for Escherichia coli O157:H7 using quantum-dot (QD) labeling and subsequent release of the QD labels from immunocomplexes has been developed. The assay principle is that anti-E. coli O157:H7 conjugated immunomagnetic beads are used to capture E. coli O157:H7; this is followed by the binding of QD labeled antibodies to form sandwich immunocomplexes (Bead-Cell-QD); a dissociation buffer then elutes QDs from immunocomplexes by denaturing antibody or lysing cell; the fluorescence signal of the eluted QDs is measured to quantify E. coli O157:H7. This proposed approach avoids the interference of bead autofluorescence in signal transduction and, thus, enhances the detection resolution, while keeping the fast magnetic separation and sandwich binding of two selective antibodies for high specificity.  相似文献   

14.
Four different food types along with environmental swabs were analyzed by the Reveal for E. coli O157:H7 test (Reveal) and the Bacteriological Analytical Manual (BAM) culture method for the presence of Escherichia coli O157:H7. Twenty-seven laboratories representing academia and private industry in the United States and Canada participated. Sample types were inoculated with E. coli O157:H7 at 2 different levels. Of the 1,095 samples and controls analyzed and confirmed, 459 were positive and 557 were negative by both methods. No statistical differences (p <0.05) were observed between the Reveal and BAM methods.  相似文献   

15.
化学发光磁酶免疫法检测O157:H7大肠埃希菌   总被引:1,自引:0,他引:1  
通过自行制备的免疫磁珠结合新型发光底物(AMPPD), 改进了化学发光磁酶免疫检测法, 对人工猪肉样品中O157:H7大肠埃希菌进行了检测, 并与人工计数法进行了比较.  相似文献   

16.
Reveal E. coli 2.0 is a new lateral-flow immunodiagnostic test for detection of E. coli O157:H7 and O157:NM in raw beef trim and ground beef. Compared with the original Reveal E. coli O157:H7 assay, the new test utilizes a unique antibody combination resulting in improved test specificity. The device architecture and test procedure have also been modified, and a single enrichment protocol was developed which allows the test to be performed at any point during an enrichment period of 12 to 20 h. Results of inclusivity and exclusivity testing showed that the test is specific for E. coli serotypes O157:H7 and O157:NM, with the exception of two strains of O157:H38 and one strain of O157:H43 which produced positive reactions. In internal and independent laboratory trials comparing the Reveal 2.0 method to the U.S. Department of Agriculture-Food Safety and Inspection Service reference culture procedure for detection of E. coli O157:H7 in 65 and 375 g raw beef trim and ground beef samples, there were no statistically significant differences in method performance with the exception of a single internal trial with 375 g ground beef samples in which the Reveal method produced significantly more positive results. There were no unconfirmed positive results by the Reveal assay, for specificity of 100%. Results of ruggedness testing showed that the Reveal test produces accurate results even with substantial deviation in sample volume or device incubation time or temperature. However, addition of the promoter reagent to the test sample prior to introducing the test device is essential to proper test performance.  相似文献   

17.
As the number of incidents of bacterial infections continues to rise around the globe, simpler, faster, and more sensitive diagnostic techniques are required to improve the safety of the food supply and to screen for potential bacterial infections in humans. We present here direct and indirect approaches for the detection of bacteria, which are based upon a combination of immunofluorescent staining and capillary electrophoresis. In the direct approach, Escherichia coli O157:H7 bacteria stained with fluorescein-tagged specific antibodies are detected by CE, while in the indirect approach fluorescein-tagged specific antibodies to E. coli are first captured by E. coli O157:H7 bacteria and then released and detected by CE. We have identified suitable bacteria staining and CE protocols, which involved a 10 mM Tris-borate-EDTA (TBE) buffer, 0.25 micro g antibody/1 million bacteria, and capillaries dynamically coated with poly-N-hydroxyethylacrylamide (polyDuramide). We have also successfully detected the presence of E. coli O157:H7 in contaminated meat. The total time required for analysis was 6-8 h, which is less than that realized in most commercial assays presently available.  相似文献   

18.
A lateral flow test strip assay, enabling sensitive detection of DNA specific to the foodborne pathogen E. coli O157:H7, is described. The use of LNA-conjugated gold nanoparticle probes, along with signal amplification protocols, results in minimum detectable concentrations of ~0.4 nM.  相似文献   

19.
Five different food types were analyzed by the Reveal for E. coli O157:H7 8-Hour Test System (Reveal 8) and either the U.S. Food and Drug Administration's Bacteriological Analytical Manual (BAM) culture method or the U.S. Department of Agriculture Food Safety Inspection Service (FSIS) culture method for the presence of E. coli O157:H7. A total of 27 laboratories representing academia and private industry in the United States and Canada participated. Food types were inoculated with E. coli O157:H7 at 2 different levels: a high level where predominantly positive results were expected, and a low level where fractional recovery was anticipated. During this study, 1,110 samples and controls were analyzed by both the Reveal 8 and by BAM or FSIS by each of the collaborators (2,220 samples in total). For each set of samples, 740 were artificially inoculated with E. coli O157:H7, and 370 were uninoculated controls. The Reveal 8 detected 528 presumptive positives of which 487 were confirmed positive by the BAM culture method. In comparison, BAM and FSIS detected 489 of the 740 artificially contaminated samples as positive. In an additional in-house study performed only on chilled and frozen raw ground beef, 240 artificially inoculated samples were analyzed by both the Reveal 8 and by FSIS. The Reveal 8 detected and confirmed 104 samples as positive compared to 79 confirmed positive by FSIS.  相似文献   

20.
化学发光磁酶免疫已经被应用于检测病原体,但是由于针对相应病原体的抗体筛选和修饰等的步骤耗时费力,不适于对多种病原体进行筛查.制备了兔抗大肠杆菌(E.coli)O157:H7的免疫磁性纳米颗粒,富集病原菌后与鼠抗E.coli O157:H7的单克隆抗体形成双抗夹心,采用碱性磷酸酶标记的马抗鼠IgG与单抗结合,加入碱性磷酸酶的化学发光底物试剂3-(2'-螺旋金刚烷)-4-甲氧基-4-(3'-羟基)苯-1,2-二氧杂环丁烷磷酸检测化学发光.实验研究了底物缓冲液、碱性磷酸酶浓度对化学发光强度的影响,比较了NaBH4和甘氨酸对免疫磁珠剩余活性醛基的封闭效果以及本方法检测E.coli O157:H7的特异性和敏感性.结果表明,碱性磷酸酶与底物在c缓冲液中反应的化学发光强度最高,碱性磷酸酶浓度决定了化学发光的强度和持续时间,NaBH4对活性醛基的封闭效果优于甘氨酸,以D群宋内氏志贺氏菌、B群福氏志贺氏菌、鼠伤寒沙门氏菌、金黄色葡萄球菌和霍乱弧菌及E.coli Top10f'为对照的比较实验显示,该检测方法具有良好的特异性,以1mL的菌液为检测体积时对E.coli O157:H7的检测灵敏度为103cell/mL,整个方法的检测时间约为3h.该方法适用于对多样本进行筛查.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏