A simplified model of heat transfer was developed to investigate the thermal behavior of heat exchangers and stack plates of thermoacoustic devices. The model took advantage of previous results describing the thermal behavior of the thermoacoustic core and heat transfer in oscillating flow to study the performance of heat exchangers attached to the core. The configuration considered is a flat tube (with a working fluid flowing in the tube) of the thickness of the stack plate attached to both ends of the stack plate. Geometrical and operational parameters as well as thermophysical properties of the heat exchangers, transport fluids in the heat exchangers, stack plate and the thermoacoustic working fluid were organized into dimensionless groups that allowed accounting for their impact on the performance of the heat exchangers. Two types of thermal boundary conditions were considered: constant temperature and constant heat flux along the heat exchanger tubes. Numerical simulations were carried out with the model introduced in the paper. The temperature distributions and heat fluxes near the edge of the stack plate were found to be nonlinear. The influence of system parameters on the thermal performance of the heat exchangers was analyzed.This article is dedicated to Prof. D. Mewes, whose knowledge, creativity, enthusiasm and dedication to engineering science was an inspiration to me and to many students, scientists, engineers and colleagues all over the world (C. Herman).  相似文献   

2.
Uniform distribution of fluids is crucial to obtain high performance in compact heat exchangers. Maldistribution has been studied by many authors, especially for parallel channels heat exchangers. But theoretical models and experimental studies for predicting flow maldistribution in offset strip fins exchangers are scarce. Offset strip fins, besides their higher thermal hydraulic performances, favour lateral distribution due to their geometry. In this work, an experimental investigation has been carried out for this type of heat exchanger. The experimental set-up consists in a flat vertical compact heat exchanger (1 m × 1 m area and 7.13 mm thickness) equipped with offset strip fins with a hydraulic diameter of 1.397 mm. Air and water are the working fluids. The flow rates of each phase in seven zones regularly distributed at the outlet have been measured as well as the pressures at the inlet, the outlet and two intermediate positions. These measurements were completed with visualisations using a high-speed camera.  相似文献   

3.
Uniform distribution of flow in tube bundle of shell and tube heat exchangers is an arbitrary assumption in conventional heat exchanger design. Nevertheless, in practice, flow maldistribution may be an inevitable occurrence which may have severe impacts on thermal and mechanical performance of heat exchangers i.e. fouling. The present models for flow maldistribution in the tube-side deal only with the maximum possible velocity deviation. Other flow maldistribution models propose and recommend the use of a probability distribution, e.g. Gaussian distribution. None of these, nevertheless, estimate quantitatively the number of tubes that suffer from flow maldistribution. This study presents a mathematical model for predicting gross flow maldistribution in the tube-side of a single-pass shell and tube heat exchanger. It can quantitatively estimate the magnitude of flow maldistribution and the number of tubes which have been affected. The validation of the resultant model has been confirmed when compared with similar study using computational fluid dynamics (CFD).  相似文献   

4.
A large number of experiments have been performed with New Zealand Forest Products Kraft black liquor to measure heat transfer coefficients and fouling rates during convective and subcooled flow boiling heat transfer as a function of surface temperature, bulk temperature, velocity, and solids concentration. Results from experiments with two chemical fouling inhibitors, with Teflon surface coating and in plate and frame heat exchangers, also are presented. The fouling deposits are analyzed with respect to appearance, composition, and process conditions for which they were obtained. With the assumption of chemical reaction-controlled fouling, a deposition model is developed and compared with the experimental data.  相似文献   

5.
The present study investigated the comparisons of the heat transfer and pressure drop of the microchannel and minichannel heat exchangers, both numerically and experimentally. The results obtained from this study indicated that the heat transfer rate obtained from microchannel heat exchanger was higher than those obtained from the minichannel heat exchangers; however, the pressure drops obtained from the microchannel heat exchanger were also higher than those obtained from the minichannel heat exchangers. As a result, the microchannel heat exchanger should be selected for the systems where high heat transfer rates are needed. In addition, at the same average velocity of water in the channels used in this study, the effectiveness obtained from the microchannel heat exchanger was 1.2–1.53 times of that obtained from the minichannel heat exchanger. Furthermore, the results obtained from the experiments were in good agreement with those obtained from the design theory and the numerical analyses.  相似文献   

6.
Quite a large quantity of waste energy is discharged into atmosphere with vapor/gas mixture. It exceeds more than 10% of the primary energy input in a plant. By developing heat exchangers resistant to the low-temperature corrosion, an efficient use of a large part of this energy can be provided. The intensity of moist air/cold water heat transfer has been experimentally determined in a semi-in-dustrial plant and given in the form of the criterion equation (diagram) with variations of inlet gas moisture, inlet gas Reynolds number, and water flow rates. This diagram enables technically reliable calculation of any heat exchanger consisting of a bundle of vertical tubes in a tube sheet.  相似文献   

7.
A set of partial differential equations is formulated which describes the transient behaviour of parallel-flow multichannel heat exchangers. In the model, the heat capacitance of walls is neglected and heat is assumed to be transferred only in the direction perpendicular to the direction of flow of fluids. The set is solved by the MacCormack predictor-corrector method for a sample four-channel heat exchanger. Three cases of transient behaviour of the exchanger are investigated: uniform initial temperatures in all channels, a step change in flow rate in one channel, and a step change in inlet temperature of one fluid. In the last two cases, the exchanger is initially at steady state.  相似文献   

8.
This research investigates the effect of fly-ash deposit on thermal performance of a cross-flow heat exchanger having a set of spiral finned-tubes as a heat transfer surface. A stream of warm air having high content of fly-ash is exchanging heat with a cool water stream in the tubes. In this study, the temperature of the heat exchanger surface is lower than the dew point temperature of air, thus there is condensation of moisture in the air stream on the heat exchanger surface. The affecting parameters such as the fin spacing, the air mass flow rate, the fly-ash mass flow rate and the inlet temperature of warm air are varied while the volume flow rate and the inlet temperature of the cold water stream are kept constant at 10 l/min and 5 °C, respectively.

From the experiment, it is found that as the testing period is shorter than 8 h the thermal resistance due to the fouling increases with time. Moreover, the deposit of fly-ash on the heat transfer surface is directly proportional to the dust–air ratio and the amount of condensate on heat exchange surface. However, the deposit of fly-ash is inversely proportional to the fin spacing. The empirical model for evaluating the thermal resistance is also developed in this work and the simulated results agree well with those of the measured data.  相似文献   


9.
Plate-and-frame heat exchangers (PHEs) operating in process industries are fouled to a greater or lesser extent depending on surface temperature, surface condition, material of construction, fluid velocity, flow geometry and fluid composition. This fouling phenomenon is time-dependent and will result in a decrease in the overall heat transfer coefficient and increase in the pressure drop of the PHE. Once the overall heat transfer coefficient decreases to a minimum acceptable level, cleaning of the equipment becomes necessary to restore the performance. In this paper, we present a simple probabilistic approach to characterize various fouling models that are commonly encountered in many industries. These random fouling growth models are then used to investigate the impact on risk based thermal effectiveness, overall heat transfer coefficient and the hot- and cold-fluid outlet temperatures of a PHE. All the results are presented in a generalized form in order to demonstrate the generality of the risk-based procedure discussed in this paper.  相似文献   

10.
In this paper, two modified types of polypropylene (PP) with high thermal conductivity up to 2.3 W/m K and 16.5 W/m K are used to manufacture the finned-tube heat exchangers, which are prospected to be used in liquid desiccant air conditioning, heat recovery, water source heat pump, sea water desalination, etc. A third plastic heat exchanger is also manufactured with ordinary PP for validation and comparison. Experiments are carried out to determine the thermal performance of the plastic heat exchangers. It is found that the plastic finned-tube heat exchanger with thermal conductivity of 16.5 W/m K can achieve overall heat transfer coefficient of 34 W/m2 K. The experimental results are compared with calculation and they agree well with each other. Finally, the effect of material thermal conductivity on heat exchanger thermal performance is studied in detail. The results show that there is a threshold value of material thermal conductivity. Below this value improving thermal conductivity can considerably improve the heat exchanger performance while over this value improving thermal conductivity contributes very little to performance enhancement. For the finned-tube heat exchanger designed in this paper, when the plastic thermal conductivity can reach over 15 W/m K, it can achieve more than 95% of the titanium heat exchanger performance and 84% of the aluminum or copper heat exchanger performance with the same dimension.  相似文献   

11.
The present study addresses fluid flow and heat transfer in a high temperature compact heat exchanger which will be used as a chemical decomposer in a hydrogen production plant. The heat exchanger is manufactured using fused ceramic layers that allow creation of channels with dimensions below 1 mm. The main purpose of this study is to increase the thermal performance of the heat exchanger, which can help to increase the sulfuric acid decomposition rate. Effects of various channel geometries of the heat exchanger on the pressure drop are studied as well. A three-dimensional computational model is developed for the investigation of fluid flow and heat transfer in the heat exchanger. Several different geometries of the heat exchanger channels, such as straight channels, ribbed ground channels, hexagonal channels, and diamond-shaped channels are examined. Based on the results, methods on how to improve the design of the heat exchanger are recommended.  相似文献   

12.
A spiral wire was used to augment the heat transfer inside the tubes of surface condensers or shell-and-tube heat exchangers. A spiral wire with a reinforcing component in the direction of the spiral axis has been investigated as a fouling cleaner on the internal surface of a tube, when it is driven in a reciprocating motion with the help of reinforcing wires. When it stays in the tube, it augments the convective heat transfer. Based on the an experimental investigation, the relationships among the heat transfer, drag, cleaning effectiveness, fouling rates, and geometric variables of the cleaner-augmenter performance were found. The results of the experimental investigations on the cleaner-augmenter and the comprehensive evaluation criterion for the device as a fouling cleaner are presented along with the dimensions of tube diameter, wire diameter, and pitch.  相似文献   

13.
The problem of heat transfer in industrial processes, heat exchangers, and combustion chambers is formulated for a case where flow inside the chamber consists of a periodic motion imposed on a fully developed turbulent flow. It is shown that the velocity pulsations induce harmonic oscillations in temperature, thus breaking the temperature field into a steady mean part and a harmonic part. The interaction between the velocity and temperature oscillations introduces an extra term into the energy equation which reflects the effect of pulsations in producing higher heat transfer rates. The analysis shows that when the mean temperature is fully developed with constant heat flux at the wall, there is no effect of the velocity pulsations on the total heat transfer rate along the chamber. For the case where the mean temperature profile is not fully developed, analytical solutions are obtained for asymptotic values of the pulsations frequency. The results show the temperature gradient and its dependence on the frequency. These results are used to evaluate the feasibility of pulsating the flow in a heat exchanger for obtaining higher rates of heat transfer.  相似文献   

14.
The thermal contact resistance is a principal parameter interfering with heat transfer in a fin–tube heat exchanger. However, the thermal contact resistance in the interface between tubes and fins has not been clearly investigated. The objective of the present study is to examine the thermal contact conductance for various fin–tube heat exchangers with tube diameter of 9.52 mm and to find a correlation between the thermal contact conductance and effective factors such as expansion ratio, fin type, fin spacing and hydrophilic coating. In this study, experiments have been conducted only to measure heat transfer rate between hot and cold water. To minimize heat loss to the ambient air by the natural convection fin–tube heat exchangers have been placed in an insulated vacuum chamber. Also, a numerical scheme has been employed to calculate the thermal contact conductance with the experimental data. As a result, a new correlation including the influences of expansion ratio, slit of fin and fin coating has been introduced, and the portion of each thermal resistance has been estimated in the fin–tube heat exchangers with 9.52 mm tube.  相似文献   

15.
The effect of pulsating flows on the performance of a heat exchanger is studied experimentally. The experiments are conducted in a steam-water, double pipe heat exchanger for 500相似文献   

16.
The aim of this paper is to present the formulas for computing the effectiveness and spatial temperature distribution of each stream and the wall of the two-pass countercrossflow heat exchangers with both fluids unmixed throughout for all possible flow arrangements. Making the usual idealizations for analysis of any heat exchanger flow arrangement and giving the coupling conditions for each pass, the problem of finding the spatial temperature distributions in the crossflow heat exchanger core is reduced to the solution of Fredholm's second order integral equation. By using the collocation method the solution of this integral equation is obtainable in the form of power series. The explicit formulas for the spatial temperature distributions and effectiveness are then obtained by simple integrations. The new relations are particularly helpful for computer-aided design procedures of two-pass countercrossflow heat exchangers.  相似文献   

17.
Since the heat transfer performance of syngas cooler affects the efficiency of the power generating system with integrated coal gasification combined cycle (IGCC) directly, it is important to obtain the heat transfer characteristics of high-pressure syngas in the cooler. Heat transfer in convection cooling section of pressurized coal gasifier with the membrane helical coils and membrane serpentine tubes under high pressure is experimentally investigated. High pressure single gas (He or N2) and their mixture (He + N2) gas serve as the test media in the test pressure range from 0.5 MPa to 3.0 MPa. The results show that the convection heat transfer coefficient of high pressure gas is influenced by the working pressure, gas composition and symmetry of flow around the coil, of which the working pressure is the most significant factor. The average convection heat transfer coefficients for various gases in heat exchangers are systematically analyzed, and the correlations between Nu and Re for two kinds of membrane heat exchangers are obtained. The heat transfer coefficient of heat exchanger with membrane helical coils is greater than that of the membrane serpentine-tube heat exchanger under the same conditions. The heat transfer coefficient increment of the membrane helical-coil heat exchanger is greater than that of the membrane serpentine-tube heat exchanger with the increase of gas pressure and velocity.  相似文献   

18.
This paper presents alternative approach in heat transfer analysis of plate heat exchangers. In order to obtain heat transfer rate and effectiveness values of plate heat exchanger, neural network (NN) approach was used. Experimentally, system used in plate heat exchanger for heating and cooling applications was designed and constructed. Experimental data were used for training and testing network. The training and validation were performed with good accuracy. The correlation coefficient obtained when unknown data were applied to the networks was 0.9994 for heat transfer rate and 0.9976 for effectiveness, which is very satisfactory. Using the weights obtained from the trained network, a new formulation is presented for determination of heat transfer rate and effectiveness. This formulation can provide simplicity in thermal analysis of plate heat exchanger. The presented procedure can also help to heat exchanger designer and manufacturer.  相似文献   

19.
The two-phase flow in the corrugated gap created by two adjacent plates of a plate heat exchanger was investigated experimentally. One setup consisting of a transparent corrugated gap was used to visualize the two-phase flow pattern and study the local phenomena of phase distribution, pressure drop and void fraction. Saturated two-phase R365mfc and an air-water mixture were used as working fluids.In a second experimental setup, the heat transfer coefficients and the pressure drop inside an industrial plate heat exchanger during the condensation process of R134a are determined. Both experimental setups use the same type of plates, so the experimental results can be connected and a flow pattern model for the condensation in plate heat exchangers can be derived. In this work the results of the flow pattern visualization, the two-phase pressure drop in the corrugated gap and the void fraction analysis by measurement of the electrical capacity are presented. A new pressure drop correlation is derived, which takes into account different flow patterns, that appear during condensation. The mean deviation of the presented pressure drop model compared to the experimental data and data from other experimental works is 18.9%. 81.7% of the calculated pressure drop lies within ±30% compared to the experimental data.  相似文献   

20.
In the present study, the heat transfer characteristics in dry surface conditions of a new type of heat exchanger, namely a helically coiled finned tube heat exchanger, is experimentally investigated. The test section, which is a helically coiled fined tube heat exchanger, consists of a shell and a helical coil unit. The helical coil unit consists of four concentric helically coiled tubes of different diameters. Each tube is constructed by bending straight copper tube into a helical coil. Aluminium crimped spiral fins with thickness of 0.5 mm and outer diameter of 28.25 mm are placed around the tube. The edge of fin at the inner diameter is corrugated. Ambient air is used as a working fluid in the shell side while hot water is used for the tube-side. The test runs are done at air mass flow rates ranging between 0.04 and 0.13 kg/s. The water mass flow rates are between 0.2 and 0.4 kg/s. The water temperatures are between 40 and 50°C. The effects of the inlet conditions of both working fluids flowing through the heat exchanger on the heat transfer coefficients are discussed. The air-side heat transfer coefficient presented in term of the Colburn J factor is proportional to inlet-water temperature and water mass flow rate. The heat exchanger effectiveness tends to increase with increasing water mass flow rate and also slightly increases with increasing inlet water temperature.  相似文献   