首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
 A fluorescence quenching method for the determination of vanadium (V) based on the vanadium- catalyzed oxidation of rhodamine 6G (R6G) with periodate in the presence of ethylenediaminetetraacetic acid disodium salt (EDTA) in sulfuric acid medium is described. The fluorescence was measured with excitation and emission wavelengths of 525 and 555 nm, respectively. The calibration graph for vanadium (V) had linear ranges of 3.0 × 10−9–1.5 × 10−8 mol/l and 1.5 × 10−8–4.0 × 10−8 mol/l, respectively. The detection limit was 1.7 × 10−9 mol/l. The proposed method was successfully applied to the determination of vanadium (V) in river water, rain water and cast iron samples. Received June 29, 2001 Revision October 9, 2001  相似文献   

2.
A new PVC membrane sensor, which is highly selective towards Ni (II) ions, has been developed using a thiophene-derivative Schiff base as the ionophore. The best performance was exhibited by the membrane having the composition percentage ratio of 5:3:61:31 (ionophore:NaTPB:DBP:PVC) (w/w), where NaTPB is the anion excluder, sodium tetraphenylborate and DBP is the plasticizing agent (dibutyl phthalate). The membrane exhibited a good Nernstian response for nickel ions over the concentration range of 1.0 × 10−1–5.0 × 10−6 M (limit of detection is 1.8 × 10−6 M) with a slope of 29.5 ± 1.0 mV per decade of activity. It has a fast response time of <20 s and can be used for a period of 4 months with good reproducibility. The sensor is suitable for use in aqueous solutions of a wide pH range of 3.2–7.9. The sensor shows high selectivity to nickel ions over a large number of mono-, bi- and trivalent cations. It has been successfully used as an indicator electrode in the potentiometric titration of nickel ions against EDTA and also for direct determination of nickel content in real samples – wastewater samples from electroplating industries and Indian chocolates.  相似文献   

3.
 A rapid flow-injection method with chemiluminescence (CL) detection is described for the determination of glutathione (GSH). The method is based on the CL reaction of luminol and hydrogen peroxide. GSH can greatly enhance the chemiluminescence intensity in 0.1 mol/L borax–sodium hydroxide buffer solution (pH = 9.7). The maximum CL intensity was directly proportional to the concentration of GSH in the range 3.0 × 10−7–2.0 × 10−5 mol/L, and the detection limit was 6.8 × 10−8 mol/L. The relative standard deviation was 3.4% for 5.0 × 10−6 mol/L of GSH (n = 11). Received October 23, 2001; accepted June 18, 2002  相似文献   

4.
In the presence of carbonate and uranine, the chemiluminescent intensity from the reaction of luminol with hydrogen peroxide was dramatically enhanced in a basic medium. Based on this fact and coupled with the technique of flow-injection analysis, a highly sensitive method was developed for the determination of carbonate with a wide linear range. The method provided the determination of carbonate with a wide linear range of 1.0 × 10−10–5.0 × 10−6 mol L−1 and a low detection limit (S/N = 3) of carbonate of 1.2 × 10−11 mol L−1. The average relative standard deviation for 1.0 × 10−9–9.0 × 10−7 mol L−1 of carbonate was 3.7% (n = 11). Combined with the wet oxidation of potassium persulfate, the method was applied to the simultaneous determination of total inorganic carbon (TIC) and total organic carbon (TOC) in water. The linear ranges for TIC and TOC were 1.2 × 10−6–6.0 × 10−2 mg L−1 and 0.08–30 mg L−1 carbon, respectively. Recoveries of 97.4–106.4% for TIC and 96.0–98.5% for TOC were obtained by adding 5 or 50 mg L−1 of carbon to the water samples. The relative standard deviations (RSDs) were 2.6–4.8% for TIC and 4.6–6.6% for TOC (n = 5). The mechanism of the chemiluminescent reaction was also explored and a reasonable explanation about chemical energy transfer from luminol to uranine was proposed. Figure Chemiluminescence profiles in batch system. 1, Injection of 100 μL of K2CO3 into 1.0 mL luminol-1.0 mL H2O2 solution; 2-3 and 4-5, Injection in sequence of 100 μL of K2CO3 and 100 μL of uranine into 1.0 ml luminol-1.0 mL H2O2 solution; Cluminol = 1.0 × 10−7 mol/L, CH2O2 = 1.0 × 10−5 mol/L, Curanine = 1.0 × 10−5 mol/L, CK2CO3 = 1.0 × 10−7 mol/L except for 4-5 where CK2CO3 = 1.0 × 10−4 mol/L  相似文献   

5.
Potassium hydrotris(N-tert-butyl-2-thioimidazolyl)borate [KTtt-Bu] and potassium hydrotris(3-tert-butyl-5-isopropyl-l-pyrazolyl)borate [KTpt-Bu,i-Pr] have been synthesized and evaluated as ionophores for preparation of a poly(vinyl chloride) (PVC) membrane sensor for Zn(II) ions. The effect of different plasticizers, viz. benzyl acetate (BA), dioctyl phthalate (DOP), dibutyl phthalate (DBP), tributyl phosphate (TBP), and o-nitrophenyl octyl ether (o-NPOE), and the anion excluders sodium tetraphenylborate (NaTPB), potassium tetrakis(p-chlorophenyl)borate (KTpClPB), and oleic acid (OA) were studied to improve the performance of the membrane sensor. The best performance was obtained from a sensor with a of [KTtt-Bu] membrane of composition (mg): [KTtt-Bu] (15), PVC (150), DBP (275), and NaTPB (4). This sensor had a Nernstian response (slope, 29.4 ± 0.2 mV decade of activity) for Zn2+ ions over a wide concentration range (1.4 × 10−7 to 1.0 × 10−1 mol L−1) with a limit of detection of 9.5 × 10−8 mol L−1. It had a relatively fast response time (12 s) and could be used for 3 months without substantial change of the potential. The membrane sensor had very good selectivity for Zn2+ ions over a wide variety of other cations and could be used in a working pH range of 3.5–7.8. The sensor was also found to work satisfactorily in partially non-aqueous media and could be successfully used for estimation of zinc at trace levels in biological and environmental samples. Electronic supplementary material The online version of this article (doi:) contains supplementary material, which is available to authorized users.  相似文献   

6.
A sensitive adsorptive anodic stripping procedure for the determination of trace zirconium at a carbon paste electrode (CPE) has been developed. The method is based on adsorptive accumulation of the Zr(IV)-alizarin red S(ARS) complex onto the surface of the CPE, followed by oxidation of adsorbed species. The optimal experimental conditions include the use of 0.10 mol · L−1 ammonium acetate buffer (pH 4.3), ARS, an accumulation potential of 0.20 V (versus SCE), an accumulation time of 2 min, a scan rate of 200 mV · s−1 and a second-order derivative linear scan mode. The oxidation peak for the complex appears at 0.69 V. The peak current is proportional to the concentration of Zr(IV) over the range of 1.0 × 10−9–2.0 × 10−7 mol · L−1, and the detection limit is 3 × 10−10 mol · L−1 for a 2 min adsorption time. The relative standard deviations (n = 8) for 5.0 × 10−8 and 5.0 × 10−9 mol · L−1 Zr(IV) are 3.3 and 4.8%, respectively. The proposed method was applied to the determination of zirconium in ore samples with satisfactory results.  相似文献   

7.
 We describe new ion-selective electrodes for piribedil (PD) based on Bi(III)-iodide or Hg(II)-iodide piribedil ion associate complexes in a poly(vinyl chloride) (PVC) membrane with dibutylphthalate (DBP) and dioctylphthalate (DOP) as plasticizing solvent mediator. The electrodes (PD-[BiI4]/DBP, PD-[BiI4]/DOP, PD-[HgI4]/DBP and PD-[HgI4]/DOP) show nearly Nernstian response over the concentration range 2 × 10−5–10−2 M of the drug. The working pH ranges were 3.1–6.0, 3.5–6.0, 3.0–6.0 and 3.5–6.4, and the isothermal coefficients of the cells were 0.00113, 0.00146, 0.00059 and 0.00120 V/°C for PD-[BiI4]/DBP, PD-[BiI4]/DOP, PD-[HgI4]/DBP and PD-[HgI4]/DOP, respectively. The selectivity coefficients for numerous compounds are given. The electrodes have been used for the direct determination of PD in pure form and in tablets or in biological fluids by the standard addition and potentiometric titration methods. Received May 30, 2001; accepted June 24, 2002  相似文献   

8.
A new Schiff-base ligand [N, N′, N″-Tri- (2,4-dihydroxyacetophenone) – triaminotriethylamine (TDATA)] with a tripodal structure was synthesized. Its fluorescence intensity with the europium(III) complex was increased about 178-fold in the presence of sodium acetate (NaAc) and about 126-fold in the presence of sodium phosphate (Na3PO4) solution. After adding the organic solvent dimethylsulfoxide (DMSO) to the above system, which leads to Eu3+ the fluorescence was further enhanced about 12-fold. Spectrofluorimetric determination of trace amounts of Eu3+ based on the phenomenon was performed. The excitation and emission wavelength is 365 nm and 615 nm, respectively. Under optimum conditions, the fluorescence intensities vary linearly with the concentration of Eu3+ in the range of 4.9 × 10−12–3.2 × 10−6 mol · L−1 with a detection limit of 4.5 × 10−12 mol · L−1 (for the TDATA-NaAc-DMSO system) or 6.2 × 10−11–8.6 × 10−6 mol · L−1 with a detection limit of 6.0 × 10−11 mol · L−1 (for the TDATA-Na3PO4-DMSO system). Interferences of some rare earth metals and other inorganic ions are described. The method is a selective, sensitive, rapid and simple analytical procedure for the determination of europium(III) in a high purity yttrium oxide and synthetic sample. The mechanism for the fluorescence enhancement is also discussed.  相似文献   

9.
 A ternary indicator system, Cadion 1B-silver ion-emulsifier octylphenyl polyglycol ether, for visual and direct titration of iodide ion with silver nitrate (as the titrant) is described. The advantages of the method are as follows: (1) when the titration reaches the equivalence point, the color of the resulting solution sharply changes from pure yellow to orange and the solution remains transparent rather than turbid; (2) the method is sensitive (the detection limit is 2 × 10−4 mol/L iodide) and accurate (the recoveries of standard addition are 99.60%–100.8%); (3) the results of titrating iodide by the method agree with those obtained by eosin B as an indicator for iodide; (4) the endpoint is much sharper than that obtained by eosin B as indicator for iodide ion; (5) the method has been successfully applied to determination of iodide in the tincture of iodine and tetrapropyl ammonium iodide samples with satisfactory results; (6) a vast amount of iodate, sulphate and fluoride ions does not interfere; (7) the method also may be automated if necessary. Received November 23, 1998. Revision November 6, 2000.  相似文献   

10.
A new method is described for the determination of ammonium in aqueous solutions with electrodes modified by Prussian blue (PB). The specific voltammetric response of PB-modified electrodes to ammonium ions is used for their analytical determination. In the presence of ammonium ions, a concentration-dependent inhibition of the low-spin iron(II/III) system of PB occurs. Only thallium and rubidium ions cause similar inhibition. A useful electrochemical determination method is thus available for detecting ammonium ions in the presence of frequently interfering potassium and sodium ions. Paraffin-impregnated graphite electrodes modified with a mechanically transferred PB layer and bulk-modified PB-composite electrodes are studied. The method is applicable within a concentration range which extends from 4 × 10−5 mol/l to 10−2 mol/l NH4 +. The composite electrode is used in an electrochemical flow-through system in conjunction with the Kjeldahl method. Received: 21 April 1997 / Accepted: 28 May 1997  相似文献   

11.
 In this work, a new ligand, 2,9-bis[N,N-bis(carboxymethyl)-aminomethyl]-1,10-phenanthroline (BBCAP), was synthesized and used to establish a novel fluorimetric method for the determination of trace amounts of terbium in a binary system. Its luminescence mechanism was studied. The excitation and emission wavelengths are 284 nm and 547 nm, respectively. Other rare-earth metal ions in 100-fold excess caused no interference. The fluorescence intensity was a linear function of the concentration of terbium in the range of 5.0 × 10−10–1.0 × 10−6 mol/L. The detection limit was 2.0 × 10−11 mol/L (n = 12). The standard addition method was used to determine the terbium in a synthetic rare-earth sample with satisfactory results. This method represents a direct, rapid, selective and sensitive analytical procedure with a widely linear range. Received November 29, 2001 Revision February 9, 2002  相似文献   

12.
Solid-contact ion-selective electrodes (SC-ISEs) can exhibit very low detection limits and, in contrast to conventional ISEs, do not require an optimization of the inner filling solution. This work shows that subnanomolar detection limits can also be achieved with SC-ISEs with three-dimensionally ordered macroporous (3DOM) carbon contacts, which have been shown recently to exhibit excellent long-term stabilities and good resistance to the interferences from oxygen and light. The detection limit of 3DOM carbon-contacted electrodes with plasticized poly-(vinyl chloride) as membrane matrix can be improved with a high polymer content of the sensing membrane, a large ratio of ionophore and ionic sites, and conditioning with a low concentration of analyte ions. This permits detection limits as low as 1.6 × 10−7 M for K+ and 4.0 × 10−11 M for Ag+.  相似文献   

13.
 A differential pulse voltammetric method for the determination of nitrate has been described, which is applicable to the analysis of natural water samples with nitrate levels greater than 2.8 × 10−6 M. A reduction peak for the nitrate ions at a freshly copper plated glassy carbon electrode was observed at about −0.50 V vs Ag ∣AgCl∣KClsatd electrode in a solution of 2.0 × 10−2 M Cu2+, 0.5 M H2SO4 and 1.0 × 10−3 M KCl and exploited for analytical purposes. The working linear range was established by regression analysis and found to extend from 2.8 ×10−6 M to 8.0 × 10−5 M. The proposed method was applied for the determination of nitrate in natural waters. The detection limit of the method was 2.8 × 10−6 M and the sensitivity was 0.9683 A·L/mol. The possible interferences by some ions such as phosphate, nitrite and some halides were determined and found to lead to shifts of the peak position and increasing the peak heights. Received March 15, 1999. Revision July 9, 1999.  相似文献   

14.
The electrocatalytic oxidation of glutathione (GSH) has been studied at the surface of ferrocene-modified carbon paste electrode (FMCPE). Cyclic voltammetry (CV), double potential step chronoamperometry, and differential pulse voltammetry (DPV) techniques were used to investigate the suitability of incorporation of ferrocene into FMCPE as a mediator for the electrocatalytic oxidation of GSH in buffered aqueous solution. Results showed that pH 7.00 is the most suitable for this purpose. In the optimum condition (pH 7.00), the electrocatalytic ability of about 480 mV can be found and the heterogeneous rate constant of catalytic reaction was calculated as . Also, the diffusion coefficient of glutathione, D, was found to be 3.61 × 10–5 cm2 s−1. The electrocatalytic oxidation peak current of glutathione at the surface of this modified electrode was linearly dependent on the GSH concentration and the linear analytical curves were obtained in the ranges of 3.2 × 10–5 M–1.6 × 10–3 M and 2.2 × 10–6 M–3.5 × 10–3 M with cyclic voltammetry and differential pulse voltammetry methods, respectively. The detection limits (3σ) were determined as 1.8 × 10–5 M and 2.1 × 10–6 M using CV and DPV, respectively. Finally, the electrocatalytic oxidation of GSH at the surface of this modified electrode can be employed as a new method for the voltammetric determination of glutathione in real samples such as human plasma.  相似文献   

15.
A novel fluorescence method has been established for the determination of gene fragment and PCR amplification products related to chronic myelogenous leukemia (CML). A molecular beacon (MB) which comprises a DNA loop section, a pair of fluorophore (tetramethoxyl rhodamine, TAMRA), and a quencher (4-(2-methyl-on-amino-azobenzene) benzoate, DABCYL) was designed. The loop sequence of MB was designed according to the DNA sequence relating to CML (type b3a2) which contained a single-stranded oligonucleotide. Before hybridization, the fluorescence from the TAMRA had been quenched by the DABCYL. After hybridization with the complementary DNA, the quencher will become far away from the TAMRA, and the fluorescence intensity detected will increase. Changes in the fluorescence intensity have a linear relationship with the concentration of complementary DNA (C) in the range of 4.0 × 10−9–3.2 × 10−8 mol/L, with a correlation coefficient of 0.9973; the detection limit was 6.0 × 10−10 mol/L (S/N = 3). The developed method has high selectivity, which can be used to discriminate single-base mismatch sequence. The method has been applied to detect the short-stranded CML DNA fragment (278 bp) with high sensitivity. This approach is a promising method for the detection of CML in real samples for medical diagnostics.  相似文献   

16.
Newly developed, simple, low-cost and sensitive ion-selective electrodes have been proposed for determination of some antiepileptic drugs such as lamotrigine, felbamate, and primidone in their pharmaceutical preparations as well as in biological fluids. The electrodes are based on poly(vinyl chloride) membranes doped with drug–tetraphenyl borate (TPB) or drug–phosphotungstic acid (PT) ion-pair complexes as molecular recognition materials. The novel electrodes displayed rapid Nernstian responses with detection limits of approximately 10−7 M. Calibration graphs were linear over the ranges 5.2 × 10−7–1.0 × 10−3, 1.5 × 10−6–1.0 × 10−3, and 2.6 × 10−7–1.0 × 10−3 M for drug–TPB and 5.8 × 10−7–1.0 × 10−3, 1.8 × 10−7–1.0 × 10−3, and 6.6 × 10−7–1.0 × 10−3 M for drug–PT electrodes, respectively, with slopes ranging from 52.3 to 62.3 mV/decade. The membranes developed have potential stability for up to 1 month and proved to be highly selective for the drugs investigated over other ions and excipients. The results show that the selectivity of the ion-selective electrodes is influenced significantly by the plasticizer. The proposed electrodes were successfully applied in the determination of these drugs in pharmaceutical preparations in four batches of different expiry dates. Statistical Student’s t test and F test showed insignificant systematic error between the ion-selective electrode methods developed and a standard method. Comparison of the results obtained using the proposed electrodes with those found using a reference method showed that the ion-selective electrode technique is sensitive, reliable, and can be used with very good accuracy and high percentage recovery without pretreatment procedures of the samples to minimize interfering matrix effects. Figure Structure of lamotrigine, felbanate and primidone  相似文献   

17.
 The construction of a liquid triphenyltetrazolium cation (TT+) ion-selective electrode (ISE) based on [TT+]3[P(W3O10)4] salt dissolved in 2-nitrotoluene is described. The liquid membrane electrode exhibits a rapid and almost Nernstian response to triphenyltetrazolium cations in the concentration range from 2×10−4 to 1×10−2 mol l−1. The Nernstian slope is 56–58 mV decade−1 which remains constant for at least two months. The response is virtually unaffected by pH changes in the range 3–12. Major interferents are periodate and malate. Deviation from linearity is also observed in the presence of bromide, iodide and thiocyanate, due to their precipitation with triphenyltetrazolium cations. Analytical applications such as direct potentiometry for the determination of TT+ in aqueous solutions and indirect potentiometry for the assay of ascorbic acid (vitamin C) in pharmaceutical preparations are described. Ascorbic acid in the range of 150–500 mg l−1, under specified experimental conditions, can be determined with mean relative error of 1.9%. Received February 25, 2000. Revision April 4, 2000.  相似文献   

18.
A novel electrochemiluminescence (ECL) “sandwich” biosensor has been developed to detect cocaine. The sandwich biosensor was fabricated on the basis of the fact that a single aptamer could be split into two fragments and the two dissociated parts could form a folded, associated complex in the presence of targets. One of these (capture probe), which had hexane–thiol at its 5′-terminus, was immobilized on a gold electrode via thiol–gold binding. The other one (detection probe) was labeled with the ECL reagent tris(2,2′-bipyridyl)ruthenium(II)-doped silica nanoparticles (RuSiNPs) at its 3′-terminus. Owing to the weak interaction between the two fragments, the sensor exhibited a low ECL signal in the absence of cocaine. After the target cocaine had been added to the solution, it induced association of the two fragments and stabilized the associated complexes, leading to immobilization of RuSiNPs on the electrode surface, and the ECL detected on the electrode surface was enhanced. The enhanced ECL intensity was directly proportional to the logarithm of the cocaine concentration in the range from 1.0 × 10−9 to1.0 × 10−11 mol/L, with a detection limit of 3.7 × 10−12 mol/L. The biosensor was applied to detect trace amounts of cocaine on banknotes with satisfactory results.  相似文献   

19.
SiO2/ZrO2/C carbon ceramic material with composition (in wt%) SiO2 = 50, ZrO2 = 20, and C = 30 was prepared by the sol–gel-processing method. A high-resolution transmission electron microscopy image showed that ZrO2 and the graphite particles are well dispersed inside the matrix. The electrical conductivity obtained for the pressed disks of the material was 18 S cm−1, indicating that C particles are also well interconnected inside the solid. An electrode modified with flavin adenine dinucleotide (FAD) prepared by immersing the solid SiO2/ZrO2/C, molded as a pressed disk, inside a FAD solution (1.0 × 10−3 mol L−1) was used to investigate the electrocatalytic reduction of bromate and iodate. The reduction of both ions occurred at a peak potential of −0.41 V vs. the saturated calomel reference electrode. The linear response range (lrr) and detection limit (dl) were: BrO3 , lrr = 4.98 × 10−5–1.23 × 10−3 mol L−1 and dl = 2.33 μmol L−1; IO3 , lrr = 4.98 × 10−5 up to 2.42 × 10−3 and dl = 1.46 μmol L−1 for iodate.  相似文献   

20.
 Sorption of copper on filter-paper with chemically attached hexamethylenediamino-groups (HMDA-filter) allows to obtain the sorbent (Cu/HMDA-filter) stable in respect to desorption of copper. A nitrogen-containing herbicide imazapyr (imaz) is retained on Cu/HMDA-filters at pH 5.5–7.0 forming a relatively stable complex. Imazapyr is determined directly on the sorbent by its activating effect in the oxidation of hydroquinone with H2O2 catalyzed by Cu(II) with the formation of a product absorbing at 490 nm. The copper ions serve both to preconcentrate imazapyr and to catalyze the indicator reaction. The use of 1-μL sample aliquots pipetted onto the Cu/HMDA-filters allows to determine 1 × 10−3–0.03 μmol of imazapyr, whereas preconcentration of the analyte by pumping of its solution through the same sorbent expands the linear range to 1 × 10−4–1 × 10−1 μmol of imazapyr. When the indicator reaction is carried out in solution, the range of activating action of imazapyr is narrower (0.06–0.1 μmol a for a solution volume of 10 mL). The determination is selective: 5–100-fold amounts of amines, aminoacids, carboxylic acid derivatives and other model compounds do not interfere. Soil extracts and carrot juice samples spiked with imazapyr have been analyzed. Received January 10, 2000. Revision July 28, 2000.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号