首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 93 毫秒
1.
Yu C  Cai Q  Guo ZX  Yang Z  Khoo SB 《The Analyst》2002,127(10):1380-1385
A novel and simple method for inorganic antimony speciation is described based on selective solid phase extraction (SPE) separation of antimony(III) and highly sensitive inductively coupled plasma mass spectrometric (ICP-MS) detection of total antimony and antimony(V) in the aqueous phase of the sample. Non-polar SPE cartridges, such as the Isolute silica-based octyl (C8) sorbent-containing cartridge, selectively retained the Sb(III) complex with ammonium pyrrolidine dithiocarbamate (APDC), while the uncomplexed Sb(V) remained as a free species in the solution and passed through the cartridge. The Sb(III) concentration was calculated as the difference between total antimony and Sb(V) concentrations. The detection limit was 1 ng L(-1) antimony. Factors affecting the separation and detection of antimony species were investigated. Acidification of samples led to partial or complete retention of Sb(V) on C8 cartridge. Foreign ions tending to complex with Sb(III) or APDC did not interfere with the retention behavior of the Sb(III)-APDC complex. This method has been successfully applied to antimony speciation of various types of water samples.  相似文献   

2.
A new method was developed for the speciation of inorganic tellurium species in seawater by inductively coupled plasma-MS (ICP-MS) following selective magnetic SPE (MSPE) separation. Within the pH range of 2-9, tellurite (Te(IV)) could be quantitatively adsorbed on gamma-mercaptopropyltrimethoxysilane (gamma-MPTMS) modified silica-coated magnetic nanoparticles (MNPs), while the tellurate (Te(VI)) was not retained and remained in solution. Without filtration or centrifugation, these tellurite-loaded MNPs could be separated easily from the aqueous solution by simply applying external magnetic field. The Te(IV) adsorbed on the MNPs could be recovered quantitatively using a solution containing 2 mol/L HCl and 0.03 mol/L K2Cr2O7. Te(VI) was reduced to Te(IV) by L-cysteine prior to the determination of total tellurium, and its assay was based on subtracting Te(IV) from total tellurium. The parameters affecting the separation were investigated systematically and the optimal separation conditions were established. Under the optimal conditions, the LOD obtained for Te(IV) was 0.079 ng/L, while the precision was 7.0% (C = 10 ng/L, n = 7). The proposed method was successfully applied to the speciation of inorganic tellurium in seawater.  相似文献   

3.
An ion chromatography-inductively coupled plasma mass spectrometric (IC-ICP-MS) method for the speciation of selenium and tellurium compounds namely selenite [Se(IV)], selenate [Se(VI)], Se-methylselenocysteine (MeSeCys), selenomethione (SeMet), tellurite [Te(IV)] and tellurate [Te(VI)] is described. Chromatographic separation is performed in gradient elution mode using 0.5 mmol L(-1) ammonium citrate in 2% methanol (pH 3.7) and 20 mmol L(-1) ammonium citrate in 2% methanol (pH 8.0). The analyses are carried out using dynamic reaction cell (DRC) ICP-MS. The DRC conditions have also been optimized to obtain interference free measurements of (78)Se(+) and (80)Se(+) which are otherwise interfered by (38)Ar(40)Ar(+) and (40)Ar(40)Ar(+), respectively. The detection limits of the procedure are in the range 0.01-0.03 ng Se mL(-1) and 0.01-0.08 ng Te mL(-1), respectively. The accuracy of the method has been verified by comparing the sum of the concentrations of individual species obtained by the present procedure with the total concentration of the elements in two NIST SRMs Whole Milk Powder RM 8435 and Rice Flour SRM 1568a. The selenium and tellurium species are extracted from milk powder and rice flour samples by using Protease XIV at 70 degrees C on a water bath for 30 min.  相似文献   

4.
Elemental selenium and tellurium, and gaseous inorganic forms of Se(IV), Se(VI), Te(IV) and Te(VI) have been determined after their adsorption on gold-coated beads. After leaching, with water and dilute hydrochloric and nitric acids, the different chemical species in each acid fraction were separated with an anion-exchange resin (Bio-Rad AG-1X8) and a cation-exchange resin (Amberlite IR-120 Plus) by varying the acidity of the leaching agent. Subsequent analysis was by graphite-fumace atomic-absorption spectrometry. The lower detection limit for Se and Te was 0.03 ng/M(3) with a precision of +/- 5%. The average amounts of selenium in interior and exterior air samples were about 4.73 and 1.93 ng/m(3) respectively. For tellurium the corresponding values were about 0.78 and 0.24 ng/m(3).  相似文献   

5.
The optimization and validation of a methodology for determining and extracting inorganic ionic Te(VI) and Te(IV) forms in easily-leached fractions of soil by Ion Chromatography-Inductively Coupled Plasma-Mass Spectrometry (IC-ICP-MS) were studied. In this paper, the total concentration of Te, pH, and red-ox potential were determined. Ions were successfully separated in 4 min on a Hamilton PRPX100 column with 0.002 mg/kg and 0.004 mg/kg limits of detection for Te(VI) and Te(IV), respectively. Soil samples were collected from areas subjected to the influence of an electrowaste processing and sorting plant. Sequential chemical extraction of soils showed that tellurium was bound mainly with sulphides, organic matter, and silicates. Optimization of soil extraction allowed 20% average extraction efficiency to be obtained, using 100 mM citric acid as the extractant. In the tested soil samples, both tellurium species were present. In most cases, the soils contained a reduced Te form, or the concentrations of both species were similar.  相似文献   

6.
Yu MQ  Liu GQ  Jin Q 《Talanta》1983,30(4):265-270
A novel procedure for determination of trace As(III) and As(V), Sb(III) and Sb(V), Se(IV) and Se(VI), Te(IV) and Te(VI) in water by atomic-absorption spectrophotometry after separation and enrichment with "thiol cotton" and hydride generation has been established. The sorption behaviour of various oxidation states of arsenic, antimony, selenium and tellurium, and the conditions of quantitative sorption and desorption of these species were studied. The procedures for reducing species from higher oxidation states were optimized. Interferences from other species and their elimination were investigated. The selectivity of the procedure for the determination of species in higher and lower oxidation states was examined. The procedure has been successfully used to determine arsenic, antimony, selenium and tellurium in water, in the range from pg ml to ng ml . The recoveries for added spikes were in the range 90-110%, with coefficients of variation in the range 3-8%  相似文献   

7.
The solutions of carrier-free125mTe(VI) have been prepared by oxidizing125mTe(IV) with bromine. Using carrier-free125mTe(VI) as a tracer, the effects of pH, NaCl concentration, and tellurium(VI) concentration on the adsorption and colloidal properties of tellurium(VI) in NaCl solution have been studied. It has been found that traces of tellurium(VI) are adsorbed on filter paper and show colloidal behavior in the basic region. A method has been devised for the separation of carrier-free125mTe from its parent nuclide125Sb, based on the adsorption properties of125mTe(VI) in basic solutions.  相似文献   

8.
A novel, fast, and cheap nonchromatographic method for direct speciation of dissolved inorganic and organic selenium species in environmental and biological samples was developed by flow injection (FI) dual-column preconcentration/separation on-line coupled with ICP-MS determination. In the developed technique, the first column packed with nanometer-sized Al(2)O(3) could selectively adsorb the inorganic selenium [Se(IV), Se(VI)], and the retained inorganic selenium could be eluted by 0.2 mol l(-1) NaOH, while the organic Se [selenocystine (SeCys(2)) and selenomethionine (Se-Met)] was not retained. On the other hand, the second column packed with mesoporous TiO(2) chemically modified by dimercaptosuccinic acid (DMSA) could selectively adsorb Se(IV) and SeCys(2) and barely adsorb Se(VI) and Se-Met. When the sample solution was passed through the column 1, separation of inorganic selenium and organic selenium could be achieved first. Then, the effluent from column 1 was successively introduced into the column 2 and the speciation of organic selenium could be attained due to the different adsorption behaviors of Se-Met and SeCys(2) on DMSA modified TiO(2). After that, the eluent from column 1 contained Se(IV), and Se(VI) was adjusted to desired pH and injected into column 2, and the speciation of Se(IV) and Se(VI) could also be realized thanks to their different retention on column 2. The parameters affecting the separation were investigated systematically and the optimal separation conditions were established. The detection limits obtained for Se(IV), Se(VI), Se-Met and SeCys(2) were 45-210 ng l(-1) with precisions of 3.6-9.7%. The proposed method has been successfully applied for the speciation of dissolved inorganic and organic selenium in environmental and biological samples. In order to validate the methodology, the developed method was also applied to the speciation of selenium in certified reference material of SELM-1 yeast, and the determined values were in good agreement with the certified values.  相似文献   

9.
The stability of arsenic, selenium, antimony and tellurium species in water and urine (NIST SRM 2670n) as well as in extracts of fish and soil certified reference materials (DORM-2 and NIST SRM 2710) has been investigated. Stability studies were carried out with As(III), As(V), arsenobetaine, monomethylarsonic acid (MMA), dimethylarsinic acid (DMA), phenylarsonic acid (PAA), Se(IV), Se(VI), selenomethionine, Sb(III), Sb(V) and Te(VI). Speciation analysis was performed by on-line coupling of anion exchange high-performance liquid chromatography (HPLC) with inductively coupled plasma mass spectrometry (ICP-MS). Best storage of aqueous mixtures of the examined species was achieved at 3 degrees C whereas at -20 degrees C species transformation especially of selenomethionine and Sb(V) took place and a new selenium species appeared within a period of 30 days. Losses and species transformations during extraction processes were investigated. Extraction of the spiked fish material with methanol/water led to partial conversion of Sb(III), Sb(V) and selenomethionine to two new antimony and one new selenium species. The other arsenic, selenium and tellurium species were almost quantitatively extracted. For soil spiked with MMA, PAA, Se(IV) and Sb(III), recoveries after extraction with water and sulfuric acid (0.01 mol/L) were below 20%.  相似文献   

10.
A new procedure has been developed for chromium speciation in aqueous solution by the use of micellar, ion-association, solid-phase extraction techniques (SPE) followed by flame atomic absorption spectrometry. The method was based on the use of C-18 bonded phase silica SPE disks for retention of ion-associated Cr(VI) with cetyl trimethyl ammonium bromide (CTAB), elution of the retained species and subsequent detection by flame atomic absorption spectrometry (FAAS). Cr(III) was oxidized by potassium persulfate to Cr(VI), then the total chromium was retained on the disk and determined by FAAS. The amount of Cr(III) was calculated by the difference between the total and Cr(VI) values. The calculated limit of detections (LOD) (based on 3sigma) are 15 microg L(-1) and 20 microg L(-1) for Cr(VI) and Cr(III) respectively. No considerable interferences have been observed from other investigated anions and cations and the method has been successfully applied to water samples taken from the Karoon River in Khuzestan province.  相似文献   

11.
Kuroda R  Yoshikuni N 《Talanta》1975,22(1):81-84
Te(IV) can be separated from Te(VI), Se(IV) and Se(VI) by adsorption of Te(IV) on a DEAE-cellulose column from a mixed 1M hydrochloric acid-acetic acid solution (1:9, v/v). This allows a selective separation of Te (IV) from the other three species in widely different mole ratios.  相似文献   

12.
A new method based on cloud point extraction (CPE) separation and electrothermal vaporization inductively coupled plasma mass spectrometry (ETV-ICPMS) detection has been proposed for the speciation of inorganic selenium in environmental waters. When the temperature of the system is higher than the cloud point temperature (CPT) of the selected surfactant Triton X-114, the complex of Se(IV) with ammonium pyrrolidine dithiocarbamate (APDC) seems to be extracted into the surfactant-rich phase, whereas the Se(VI) remains in aqueous solutions. Thus, an in situ separation of Se(IV) and Se(VI) could be realized. The concentrated analyte was introduced into the ETV-ICP mass spectrometer for determination of Se((IV) after dilution with 200 microL methanol. Se(VI) was reduced to Se(IV) prior to determining total selenium, and its assay was based on subtracting Se(IV) from total selenium. The main factors affecting the CPE and the vaporization behavior of the analyte were investigated in detail. Under the optimized experimental conditions, the limit of detection (LOD) for Se(IV) was 8.0 ng/L with an enhancement factor of 39 when 10 mL of sample solution was preconcentrated to 0.2 mL. The relative standard deviation (RSD) was found to be 3.9% (C(Se(IV)) = 1.0 microg/L, n = 7). The proposed method was applied to the speciation of inorganic selenium in different environmental water samples with the recovery for the spiked samples in the range of 82-102%.  相似文献   

13.
Hydride generation (HG) coupled with AAS, ICP–AES, and AFS techniques for the speciation analysis of As, Sb, Se, and Te in environmental water samples is reviewed. Careful control of experimental conditions, offline/online sample pretreatment methods employing batch, continuous and flow-injection techniques, and cryogenic trapping of hydrides enable the determination of various species of hydride-forming elements without the use of chromatographic separation. Other non-chromatographic approaches include solvent extraction, ion exchange, and selective retention by microorganisms. Sample pretreatment, pH dependency of HG, and control of NaBH4/HCl concentration facilitate the determination of As(III), As(V), monomethylarsonate (MMA), and dimethylarsinate (DMA) species. Inorganic species of arsenic are dominant in terrestrial waters, whereas inorganic and methylated species are reported in seawater. Selenium and tellurium speciation analysis is based on the hydrides generation only from the tetravalent state. Se(IV) and Se(VI) are the inorganic selenium species mostly reported in environmental samples, whereas speciation of tellurium is rarely reported. Antimony speciation analysis is based on the slow kinetics of hydride formation from the pentavalent state and is mainly reported in seawater samples.  相似文献   

14.
Summary A method is described to convert elemental tellurium and organotellurium compounds quantitatively to Te(IV) by digestion with a mixture of nitric and sulfuric acids in the micro-Kjeldahl flask. After removal of nitrogen oxides by means of urea, exactly 5 ml of 0.02N potassium dichromate is added, whereupon Te(IV) is oxidized to Te(VI). The tellurium content of the sample is related to the amount of dichromate consumed, the latter being determined either spectrophotometrically or by back-titration with 0.02N ferrous sulfate. This method, applicable to 1–4 mg of tellurium, is amenable to automation and multi-element determinations.
Zusammenfassung Ein Verfahren zur quantitativen Überführung von elementarem und organisch gebundenem Tellur in Te(IV) durch Mineralisierung mit einem Gemisch von Salpetersäure und Schwefelsäure im Mikro-Kjeldahl-Kölbchen wurde beschrieben. Nach Entfernung der Stickoxide mit Harnstoff werden genau 5 ml 0,02-n Kaliumbichromat zugesetzt, wodurch Te(IV) zu Te(VI) oxydiert wird. Der Tellurgehalt der Probe ergibt sich aus der Menge verbrauchten Bichromats, die entweder spektrophotometrisch oder durch Rücktitration mit 0,02-n Eisen(II)-sulfat bestimmt wird. Dieses auf 1 bis 4 mg Te anwendbare Verfahren ist automatisierbar und bei gleichzeitiger Bestimmung mehrerer Elemente anwendbar.
  相似文献   

15.
Jiankuan Duan  Bin Hu  Man He 《Electrophoresis》2012,33(19-20):2953-2960
In this paper, a new method of nanometer‐sized alumina packed microcolumn SPE combined with field‐amplified sample stacking (FASS)–CE‐UV detection was developed for the speciation analysis of inorganic selenium in environmental water samples. Self‐synthesized nanometer‐sized alumina was packed in a microcolumn as the SPE adsorbent to retain Se(IV) and Se(VI) simultaneously at pH 6 and the retained inorganic selenium was eluted by concentrated ammonia. The eluent was used for FASS–CE–UV analysis after NH3 evaporation. The factors affecting the preconcentration of both Se(IV) and Se(VI) by SPE and FASS were studied and the optimal CE separation conditions for Se(IV) and Se(VI) were obtained. Under the optimal conditions, the LODs of 57 ng L?1 (Se(IV)) and 71 ng L?1 (Se(VI)) were obtained, respectively. The developed method was validated by the analysis of a certified reference material of GBW(E)080395 environmental water and the determined value was in a good agreement with the certified value. It was also successfully applied to the speciation analysis of inorganic selenium in environmental water samples, including Yangtze River water, spring water, and tap water.  相似文献   

16.
Osmium(VIII) catalyzed oxidation of tellurium(IV) by periodate in alkaline medium is found to occurvia oxidant-catalyst complex formation in a slow step followed by the interaction of substrate and complex in the fast step to yield the products with regeneration of catalyst. One of the products, Te(VI), considerably retards the rate of reaction. The reaction shows zero order in [tellurium(IV)], first order each in [IO4] and [Os(VIII)] and an inverse fractional order dependence on [OH]. A plausible mechanism is proposed and the reaction constants involved in the mechanism are derived.  相似文献   

17.
A procedure for determining the concentrations of dissolved chromium species in natural waters is described. Chromium(III) and chromium(VI), separated by co-precipitation with hydrated iron(III) oxide, and total dissolved chromium are determined separately by conversion to chromium(VI), extraction with APDC into MIBK and determination by a.a.s. The detection limit is 40 ng l?1 Cr. The dissolved chromium not amenable to separation and direct extraction is calculated by difference. In the waters investigated, total concentrations were relatively high (1–5 μg l?1) with Cr(VI) the predominant species in all areas sampled with one exception, where organically bound chromium was the major species.  相似文献   

18.
Sargar BM  Anuse MA 《Talanta》2001,55(3):469-478
N-n-Octylaniline in xylene is used for extractive separation of tellurium(IV) from hydrochloric acid media. Tellurium(IV) is extracted quantitatively with the 3% reagent in xylene from 5.5 to 7.5 M hydrochloric acid. It is stripped from organic phase with 1:1 ammonia and estimated spectrophotometrically with pyrimidine-2-thiol (4'-bromoPTPT). The effects of metal ion, acids, reagent concentration, diluents and various foreign ions have been investigated. The log-log plots of distribution ratio (D(Te(IV))) versus N-n-octylaniline concentration indicate that the nature of extracted species is [(RR'NH(2)(+))(2) TeCl(6)(2-)](org). The method affords binary separation of tellurium(IV) from gold(III), selenium(IV), bismuth(III), copper(II), lead(II), antimony(III), germanium(IV) and is applicable to the analyses of synthetic mixture containing associated metal ions and alloy samples. The method is simple, selective, rapid and accurate.  相似文献   

19.
The anodic stripping determination of Te(IV) using a rotating glassy carbon disc electrode is described. 0.1 ppm tellurium can be determined in 1 M HCl. Interfering effects of the metals forming intermetallic compounds with tellurium on the electrode are eliminated by solvent extraction. Te(IV) is determined either after its extraction — as an ion associate or as the chelate with diphenylthiocarbazone — in the organic phase which is adjusted for the stripping determination by the addition of methanolic solution of LiCl or after the separation of all interfering elements by an extraction procedure involving the extraction of Te(IV) into methylisobutylketone and back extraction of Te(IV) with water followed by the separation of the remaining interfering elements into diisopropylether. The proposed method enables the determination of 10 μg Te in the presence of 25 mg Pb and Sb and 0.5 mg Ag, Cu, Bi, As, Sn, Cd, Zn with reproducible results and error ±5%.  相似文献   

20.
A new method for the simultaneous separation and determination of four arsenic species [As(III), As(V), monomethylarsonic acid and dimethylarsinic acid], three selenium species [Se(IV), Se(VI) and selenomethionine] as well as Sb(III) and Sb(V) is presented. The speciation was achieved by on-line coupling of anion exchange high-performance liquid chromatography (HPLC) with inductively coupled plasma mass spectrometry (ICP-MS). Chromatographic parameters such as the composition and pH of the mobile phase were optimised. Limits of detection are below 4.5 μg L–1 (as element) for Sb(III) and the selenium species and below 0.5 μg L–1 for the other species. Precisions of retention times were better than 2% RSD and of peak areas better than 8% RSD for all the species investigated.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号