首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
The highly selective, fast and effective sample pretreatment technique molecularly imprinted solid-phase extraction (MISPE) can overcome the low sensitivity of the highly efficient capillary electrophoresis-UV method (CE-UV). In this work, narrowly dispersible bisphenol A (BPA)-imprinted polymeric microspheres with a high capacity factor of k′ = 6.8 and an imprinted factor of I = 6.53 were investigated as selective solid-phase extraction (SPE) sorbents for use in extraction of BPA from different sample matrices (tap water, wastewater, Yangtze River water, soil from the Yangtze River, shrimp and human urine). Washing and eluting protocols of MISPE were optimized. Under optimal conditions, recoveries of MISPE were investigated. Recoveries were basically constant and the relative standard deviation (RSD) was lower than 5.8% when loading volumes changed from 1 to 50 mL. Recoveries ranged from 71.20% to 86.23% for different sample matrices. Compared with C18 SPE, MISPE had higher selectivity and recovery for BPA. BPA was determined with good accuracy and precision in different complex samples using CE-UV coupled with MISPE. Spiked recoveries ranged from 95.20% to 105.40%, and the RSD was less than 7.2%. Because a large loading volume was achieved, the enrichment efficiency of pretreatment and the sensitivity of this method were improved. The limits of detection of this MISPE-CE-UV method for BPA in tap water, wastewater, Yangtze River water, soil from the Yangtze River, shrimp and human urine were 3.0 μg L− 1, 5.4 μg L− 1, 6.9 μg L− 1, 2.1 μg L− 1, 1.8 μg L− 1 and 84 μg L− 1, respectively.  相似文献   

2.
Dispersive liquid–liquid microextraction (DLLME) coupled with high-performance liquid chromatography (HPLC)-UV detection was applied for the extraction and determination of bisphenol A (BPA) in water samples. An appropriate mixture of acetone (disperser solvent) and chloroform (extraction solvent) was injected rapidly into a water sample containing BPA. After extraction, sedimented phase was analyzed by HPLC-UV. Under the optimum conditions (extractant solvent: 142 μL of chloroform, disperser solvent: 2.0 mL of acetone, and without salt addition), the calibration graph was linear in the range of 0.5–100 μg L−1 with the detection limit of 0.07 μg L−1 for BPA. The relative standard deviation (RSD, n = 5) for the extraction and determination of 100 μg L−1 of BPA in the aqueous samples was 6.0%. The results showed that DLLME is a very simple, rapid, sensitive and efficient analytical method for the determination of trace amount of BPA in water samples and suitable results were obtained.  相似文献   

3.
This paper describes the development of a multi-residue method for the determination of 36 emerging organic pollutants (26 biocides, 5 UV-filters and 5 benzothiazoles) in raw and treated wastewater, activated sludge and surface water using liquid chromatography–tandem mass spectrometry (LC–MS/MS). The target analytes were enriched from water samples adjusted to pH 6 by solid-phase extraction (SPE) on Oasis HLB 200 mg cartridges and eluted with a mixture of methanol and acetone (60/40, v/v). Extraction of freeze-dried sludge samples was accomplished by pressurized liquid extraction (PLE) using a mixture of methanol and water (50/50, v/v) as extraction solvent followed by SPE. LC–tandem MS detection was compared using electrospray ionization (ESI) and atmospheric pressure chemical ionization (APCI) in positive and negative ionization mode. ESI exhibited strong ion suppression for most target analytes, while APCI was generally less susceptible to ion suppression but partially leading to ion enhancement of up to a factor of 10. In general, matrix effects could be compensated using stable isotope-labeled surrogate standards, indicated by relative recoveries ranging from 70% to 130%. In wastewater, activated sludge and surface water up to 33 analytes were detected. Maximum concentrations up to 5.1 and 3.9 μg L−1 were found in raw wastewater for the water-soluble UV-filters benzophenone-4 (BZP-4) and phenylbenz-imidazole sulfonic acid (PBSA), respectively. For the first time, the anti-dandruff climbazole was detected in raw wastewater and in activated sludge with concentrations as high as 1.4 μg L−1 and 1.2 μg g TSS−1, respectively. Activated sludge is obviously a sink for four benzothiazoles and two isothiazolones, as concentrations were detected in activated sludge between 120 ng g TSS−1 (2-n-octyl-4-isothiazolin-3-one, OIT) to 330 ng g TSS−1 (benzothiazole-2-sulfonic acid, BTSA).  相似文献   

4.
Biosensor immunoassays for the detection of bisphenol A   总被引:1,自引:0,他引:1  
Bisphenol A (BPA) is a xenoestrogen found in the environment, in consequence, for the biosensor detection of BPA we raised antibodies (polyclonal (PAbs) and monoclonal (MAbs)) against a structural analogue of BPA, 4,4 bis-(4-hydroxyphenyl) valeric acid (BVA). The kinetics of the MAb-BPA interaction were evaluated and the MAb providing the highest affinity was directly immobilized onto the sensor chip surface to evaluate a direct assay. Afterwards, the performance of the MAbs and the PAbs was compared in an inhibition assay using a BVA-coated chip.The highest sensitivity (limit of detection (LOD) of 0.4 μg L−1) was obtained with MAb 12 in the direct assay. However, the inhibition assay was the most robust and the PAbs showed the highest sensitivity (LOD of 0.5-1 μg L−1). The antibodies were specific for BVA and BPA as only minor cross-reactivities were found toward structurally related compounds or other endocrine disruptors. In the inhibition assay (with a run time of 6 min), water samples spiked with BPA at different levels (0.5-50 μg L−1) resulted in recoveries varying between 68% and 121%. The sensitivity of the inhibition assay could be improved 40 times (LOD of 0.03 μg L−1 with the Mab 12-based assay) using solid phase extraction (SPE).  相似文献   

5.
Four-way data were obtained by recording the kinetic evolution of excitation-emission fluorescence matrices for samples containing the analytes carbaryl and 1-naphthol, two widely employed pesticides, in the concentration ranges 0-363 μg L−1 and 0-512 μg L−1, respectively. The reaction followed was the alkaline hydrolysis of carbaryl to produce 1-naphthol, a fact which introduced strong linear dependencies and multi-linearity losses in the analyzed system. Data processing was performed with unfolded partial least-squares combined with residual trilinearization (U-PLS/RTL) and also with a suitably initialized and restricted parallel factor model (PARAFAC), combined with calibration based on multi-linear regression. U-PLS/RTL is shown to be significantly simpler in its implementation and to provide similar figures of merit. The applied chemometric strategy is able to successfully determine the analytes in water samples containing uncalibrated interferences, such as other commonly employed agrochemicals and also a naturally occurring background signal.  相似文献   

6.
A simple and fast sample preparation method for the determination of nonylphenol (NP) and octylphenol (OP) in aqueous samples by simultaneous derivatization and dispersive liquid–liquid microextraction (DLLME) was investigated using gas chromatography–mass spectrometry (GC/MS). In this method, a combined dispersant/derivatization catalyst (methanol/pyridine mixture) was firstly added to an aqueous sample, following which a derivatization reagent/extraction solvent (methyl chloroformate/chloroform) was rapidly injected to combine in situ derivatization and extraction in a single step. After centrifuging, the sedimented phase containing the analytes was injected into the GC port by autosampler for analysis. Several parameters, such as extraction solvent, dispersant solvent, amount of derivatization reagent, derivatization and extraction time, pH, and ionic strength were optimized to obtain higher sensitivity for the detection of NP and OP. Under the optimized conditions, good linearity was observed in the range of 0.1–1000 μg L−1 and 0.01–100 μg L−1 with the limits of detection (LOD) of 0.03 μg L−1 and 0.002 μg L−1 for NP and OP, respectively. Water samples collected from the Pearl River were analyzed with the proposed method, the concentrations of NP and OP were found to be 2.40 ± 0.16 μg L−1 and 0.037 ± 0.001 μg L−1, respectively. The relative recoveries of the water samples spiked with different concentrations of NP and OP were in the range of 88.3–106.7%. Compared with SPME and SPE, the proposed method can be successfully applied to the rapid and convenient determination of NP and OP in aqueous samples.  相似文献   

7.
A novel 8-electrode array as stir bar was designed for selective extraction of trace level exogenous estrogens from food samples, followed by liquid desorption and HPLC-photodiode array detection. The array consisted of 8 screen-printed electrodes and each electrode was modified with Fe3O4@meso-/macroporous TiO2 microspheres and molecularly imprinted film (m-TiMIF). The fabrication of the imprinted film coating was very simple without organic solvents and chemical grafting. Both bisphenol A (BPA) and diethylstilbestrol (DES) were employed as templates in m-TiMIF fabrication in order to enrich both targets simultaneously. Interestingly, the imprinted stir bar array showed higher extraction capacity and selectivity for BPA and DES than the non-imprinted counterpart. Meanwhile, it exhibited fast adsorption and desorption kinetics due to increased mass transport in the ultra-thin film. Importantly, the m-TiMIF coating was robust enough for at least 20 uses without obvious alteration in extraction performance. The main parameters affecting the extraction efficiency, including stir speeding, sample pH, ionic strength, extraction time, desorption solvent and time, were optimized. Under optimal experimental conditions, the limits of detection (S/N = 3) of the developed method were 0.28 and 0.47 μg L−1 for BPA and DES respectively, with enrichment factors of 32.6 and 52.8-fold. The linear ranges were 3.0–1500 μg L−1 and 4.0–1500 μg L−1 for BPA and DES, respectively. The m-TiMIF-coating conferred better recovery and selectivity, compared with the commercial stir bar coating. The new method was successfully applied to assess BPA and DES in pork and chicken samples with satisfactory recovery.  相似文献   

8.
A new combined method including fiber optic-linear array detection spectrophotometry (FO-LADS) and cloud point extraction (CPE) was developed using a cylindrical micro cell for simultaneous preconcentration and determination of different species. The CPE and FO-LADS methods have good matching conditions for combination because FO-LADS is suitable as a detection technique for the low volume of remained phase obtained after CPE. This combination was carried out using 50 μL cylindrical micro cell and then employed for simultaneous preconcentration and determination of cobalt and nickel.Cloud point extraction method was based on the chromogenic reaction of metal ions and 1-(2-pyridylazo)-2-naphthol (PAN) and then preconcentration of formed complexes using octylphenoxypolyethoxyethanol (Triton X-114). The remained phase after CPE was transferred into cylindrical micro cell and located at the cell holder of FO-LADS. The spectra of cobalt and nickel complexes were collected by FO-LADS and processed for ordinary and first derivative spectrophotometry.Optimization of different parameters was evaluated. Under optimum conditions, calibration curves were linear in the range of 0.6-30.0 and 0.1-15.0 μg L−1 with detection limits of 0.2 and 0.04 μg L−1 for Co and Ni respectively. The relative standard deviations (R.S.D.s) were lower than 4%. The obtained enhancement factors were 198 and 199 for cobalt and nickel, respectively.The proposed method was compared with the other methods and applied to the analysis of several real and spiked samples.  相似文献   

9.
This paper presents a material that has both hydrophilic and hydrophobic domains, obtained by combination of a polyampholyte with a surfactant. This material was fully characterized by different spectroscopic techniques and microscopy.Bisphenol-A (BPA) was chosen as a model molecule to study the interaction with compounds of intermediate polarity. We explored the kinetics and equilibrium of BPA on the surface of the polyampholyte-surfactant complex and found a significantly high loading capacity (2.02 mmol g−1) and complete binding from solutions at concentration levels below 100 μmol L−1.The complex was encapsulated in agarose gel to be used as solid phase for extraction of BPA from food simulants in contact with polycarbonate bottles under different treatments. Bisphenol was preconcentrated, extracted and analysed by liquid chromatography with an amperometric detector. The instrumental detection limit of the technique was 10 μg L−1, which was lowered to 0.14 μg L−1 by the preconcentration step. The BPA released from baby bottles was 2.1 ng cm−2 (σn − 1: 0.1) in the first use with distilled water.  相似文献   

10.
A simple, sensitive and powerful on-line sequential injection (SI) dispersive liquid-liquid microextraction (DLLME) system was developed as an alternative approach for on-line metal preconcentration and separation, using extraction solvent at microlitre volume. The potentials of this novel schema, coupled to flame atomic absorption spectrometry (FAAS), were demonstrated for trace copper and lead determination in water samples. The stream of methanol (disperser solvent) containing 2.0% (v/v) xylene (extraction solvent) and 0.3% (m/v) ammonium diethyldithiophosphate (chelating agent) was merged on-line with the stream of sample (aqueous phase), resulting a cloudy mixture, which was consisted of fine droplets of the extraction solvent dispersed entirely into the aqueous phase. By this continuous process, metal chelating complexes were formed and extracted into the fine droplets of the extraction solvent. The hydrophobic droplets of organic phase were retained into a microcolumn packed with PTFE-turnings. A portion of 300 μL isobutylmethylketone was used for quantitative elution of the analytes, which transported directly to the nebulizer of FAAS. All the critical parameters of the system such as type of extraction solvent, flow-rate of disperser and sample, extraction time as well as the chemical parameters were studied. Under the optimum conditions the enhancement factor for copper and lead was 560 and 265, respectively. For copper, the detection limit and the precision (R.S.D.) were 0.04 μg L−1 and 2.1% at 2.0 μg L−1 Cu(II), respectively, while for lead were 0.54 μg L−1 and 1.9% at 30.0 μg L−1 Pb(II), respectively. The developed method was evaluated by analyzing certified reference material and applied successfully to the analysis of environmental water samples.  相似文献   

11.
The simultaneous extraction of acidic and basic analytes from a particular sample is a challenging task. In this work, electromembrane extraction (EME) of acidic non-steroidal anti-inflammatory drugs and basic β-blockers in a single step was carried out for the first time. It was shown that by designing an appropriate compartmentalized membrane envelope, the two classes of drugs could be electrokinetically extracted by a 300 V direct current electrical potential. This method required only a very short 10-min extraction time from a pH-neutral sample, with a small amount (50 μL) of organic solvent (1-octanol) as the acceptor phase. Analysis was carried out using gas chromatography–mass spectrometry after derivatization of the analytes. Extraction parameters such as extraction time, applied voltage, pH range, and concentration of salt added were optimized. The proposed EME technique provided good linearity with correlation coefficients from 0.982 to 0.997 over a concentration range of 1–200 μg L−1. Detection limits of the drugs ranged between 0.0081 and 0.26 μg L−1, while reproducibility ranged from 6 to 13% (n = 6). Finally, the application of the new method to wastewater samples was demonstrated.  相似文献   

12.
The cloud point extraction (CPE) of commercial copper(II) oxide nanoparticles (CuO NPs, mean diameter of 28 nm) in water samples was fully investigated. Factors such as Triton X-114 (TX-114) concentration, pH, incubation temperature and time, were optimized. The effects of CuO NP behavior like agglomeration, dissolution, and surface adsorption of natural organic matter, Cu2+, and coating chemicals, on its recovery were studied. The results indicated that all the CPE factors had significant effects on the extraction efficiency. An enrichment factor of ∼89 was obtained under optimum CPE conditions. The hydrodynamic diameter of CuO NPs increased to 4–5 μm upon agglomeration of NP-micelle assemblies, and decreased at pH >10.0 at which the extraction efficiency was also lowered. The solubility and therefore, the loss of NPs were greatly enhanced at pH <8.5 and in the first 60 min of incubation, whereas it declined at elevated incubation temperatures. Our results showed that the dissolved organic carbon (DOC) >5 mg C L−1 and Cu2+ >2 times that of CuO NPs, lowered and enhanced the extraction efficiency, respectively. Pre-treatment of samples with 3% w v−1 of hydrogen peroxide and 10 mM of ethylenediaminetetraacetic acid minimized the interferences posed by DOC and Cu2+, respectively. The decrease in CPE efficiency was also evident for ligands like poly(ethylene glycol). The TX-114-rich phase could be determined with either inductively coupled plasma mass spectrometry following microwave digestion, or graphite furnace atomic absorption spectrometry. The detection limits for CuO NPs were 0.02 and 0.06 μg L−1 using these techniques, respectively. The optimum sample pre-treatment and CPE conditions were successfully applied to the river and wastewater samples. The relative recoveries of CuO NPs spiked at 5–100 μg L−1 (as Cu) in these samples were in the range of between 59.2 and 108.2%. The approach demonstrates a robust analytical method for detecting trace levels of CuO NPs at their original states and assessing their exposure risks in real aquatic environments.  相似文献   

13.
The dispersive liquid-liquid microextraction (DLLME) was combined with the flame atomic absorption spectrometry (FAAS) for determination of lead in the water samples. Diethyldithiophosphoric acid (DDTP), carbon tetrachloride and methanol were used as chelating agent, extraction solvent and disperser solvent, respectively. A new FAAS sample introduction system was employed for the microvolume nebulization of the non-flammable chlorinated organic extracts. Injection of 20 μL volumes of the organic extract into an air-acetylene flame provided very sensitive spike-like and reproducible signals.Some effective parameters on the microextraction and the complex formation were selected and optimized. These parameters include extraction and disperser solvent type as well as their volume, extraction time, salt effect, pH and amount of the chelating agent. Under the optimized conditions, the enrichment factor of 450 was obtained from a sample volume of 25.0 mL. The enhancement factor, calculated as the ratio of the slopes of the calibration graphs with and without preconcentration, which was about 1000. The calibration graph was linear in the range of 1-70 μg L−1 with a detection limit of 0.5 μg L−1. The relative standard deviation (R.S.D.) for seven replicate measurements of 5.0 and 50 μg L−1 of lead were 3.8 and 2.0%, respectively. The relative recoveries of lead in tap, well, river and seawater samples at the spiking level of 20 μg L−1 ranged from 93.8 to 106.2%. The characteristics of the proposed method were compared with those of the liquid-liquid extraction (LLE), cloud point extraction (CPE), on-line and off-line solid-phase extraction (SPE) as well as co-precipitation, based on bibliographic data. Operation simplicity, rapidity, low cost, high enrichment factor, good repeatability, and low consumption of the extraction solvent at a microliter level are the main advantages of the proposed method.  相似文献   

14.
Zhou Q  Gao Y  Xie G 《Talanta》2011,85(3):1598-1602
Present study described a simple, sensitive, and viable method for the determination of bisphenol A, 4-n-nonylphenol and 4-tert-octylphenol in water samples using temperature-controlled ionic liquid dispersive liquid-phase microextraction coupled to high performance liquid chromatography-fluorescence detector. In this experiment, 1-octyl-3-methylimidazolium hexafluorophosphate ([C8MIM][PF6]) was used as the extraction solvent, and bisphenol A, 4-n-nonylphenol and 4-tert-octylphenol were selected as the model analytes. Parameters affecting the extraction efficiency such as the volume of [C8MIM][PF6], dissolving temperature, extraction time, sample pH, centrifuging time and salting-out effect have been investigated in detail. Under the optimized conditions, good linear relationship was found in the concentration range of 1.0-100 μg L−1 for BPA, 1.5-150 μg L−1 for 4-NP, and 3-300 μg L−1 for 4-OP, respectively. Limits of detection (LOD, S/N = 3) were in the range of 0.23-0.48 μg L−1. Intra day and inter day precisions (RSDs, n = 6) were in the range of 4.6-5.5% and 8.5-13.3%, respectively. This method has been also successfully applied to analyze the real water samples at two different spiked concentrations and excellent results were obtained.  相似文献   

15.
A cloud point extraction (CPE) method has been developed for the preconcentration of trace aluminum prior to its determination by flame atomic absorption spectrometry (FAAS). The CPE method is based on the complex of Al(III) with Xylidyl Blue (XB) and then entrapped in non-ionic surfactant Triton X-114. The main factors affecting CPE efficiency, such as pH of sample solution, concentration of XB and Triton X-114, equilibration temperature and time, were investigated in detail. An enrichment factor of 50 was obtained for the preconcentration of Al(III) with 50 mL solution. Under the optimal conditions, the detection limit of this method for Al(III) is 1.43 μg L− 1, and the relative standard deviation is 2.7% at determination of 100 μg L− 1 Al(III). The proposed method has been applied for determination of trace amount of aluminum in mineral water samples with satisfactory results. Also, the proposed method was applied to the certified reference materials. The results obtained were in good agreement with certified values.  相似文献   

16.
A new on-line cloud point extraction (CPE) system coupled to ICP-OES was designed for simultaneous extraction, preconcentration and determination of Cd2+, Co2+, Cr3+, Cu2+, Fe3+ and Mn2+ ions in water samples. This is based on the complexation of the metal ions with 1-(2-thenoyl)-3,3,3-trifluoraceton reagent (TTA) at pH 6.0 in the presence of non-ionic surfactant of Triton X-114. The micellar solution was heated above 60 °C and loaded through a column packed with cotton, which acts as a filter for retaining the analyte-entrapped surfactant-rich phase. Then the surfactant-rich phase was eluted using propanol:0.5 mol L−1 nitric acid solution (75:25, v/v) at a flow rate of 3.0 mL min−1 and directly introduced into the nebulizer of the ICP-OES. Several factors influencing the instrumental conditions and extraction were evaluated and optimized. Under the optimum conditions, the enhancement factors of the proposed method for target ions were between 42 and 97, the detection limits (DLs) were in the range of 0.1-2.2 μg L−1. The relative standard deviations (R.S.D.s) at 100 μg L−1 concentration levels of each ion were found to be less than 4.6%. Also, the calibration graphs were linear in the range of 0.5-100 μg L−1 with the correlation coefficients within the range of 0.9948-0.9994.Finally, the developed method was successfully applied to the extraction and determination of the mentioned metal ions in the tap, well, sea and mineral water samples and satisfactory results were obtained.  相似文献   

17.
Ulusoy Hİ  Akçay M  Gürkan R 《Talanta》2011,85(3):1585-1591
The simple and rapid preconcentration technique using cloud point extraction (CPE) was applied for the determination of As(V) and total inorganic arsenic (As(V) plus As(III)) in water samples by means of FAAS. As(V) has formed an ion-pairing complex with Pyronine B in the presence of cetyl pyridinium chloride (CPC) at pH 8.0 and extracted into the non-ionic surfactant Triton X-114, after centrifugation the surfactant-rich phase was separated and diluted with 1.0 mol L−1 HNO3 in methanol. The proposed method is very versatile and economic because it exclusively used conventional FAAS. After optimization of the CPE conditions, a preconcentration factor of 120, the detection and quantification limits of 1.67 and 5.06 μg L−1 with a correlation coefficient of 0.9978 were obtained from the calibration curve constructed in the range of 5.0-2200 μg L−1. The relative standard deviation, RSD as a measure of precision was less than 4.1% and the recoveries were in the range of 98.2-102.4%, 97.4-101.2% and 97.8-101.1% for As(V), As(III) and total As, respectively. The method was validated by the analysis of standard reference materials, TMDA-53.3 and NIST 1643e and applied to the determination of As(III) and As(V) in some real samples including natural drinking water and tap water samples with satisfactory results. The results obtained (34.70 ± 1.08 μg L−1 and 60.25 ± 1.07 μg L−1) were in good agreement with the certified values (34.20 ± 1.38 μg L−1 and 60.45 ± 1.78 μg L−1).  相似文献   

18.
Ozer ET  Güçer S 《Talanta》2011,84(2):362-367
The determination of six phthalate acid esters was achieved in artificial saliva using gas chromatography-mass spectrometry following activated carbon enrichment of samples. Central composite experimental design was applied to optimize method parameters, such as pH, adsorption time and amount of activated carbon. The best compromise of analytical conditions for the simultaneous determination of analytes from spiked artificial saliva were found to be: pH (3), adsorption time (30 min), activated carbon amount (1.8 g L−1) and elution solvent (chloroform). These conditions were applied to study the migration of phthalate acid esters from different children's toys into saliva. A horizontal agitation method was applied to extract the analytes from plastic toys into saliva for 2 h at 37 °C. The detection limits of the method were in the range of 1.3-5.1 μg L−1, while the relative standard deviation (%) values for the analysis of 100 μg L−1 of the analytes were below 3.0% (n = 5). Di-2-ethylhexyl phthalate was the main analyte found in these samples.  相似文献   

19.
Matrix interference removal is an important step when large volumes of aqueous samples are required to be processed to detect trace levels of analytes. A combination of two sample extraction methods has been used in this work with the aim of cleanup and preconcentration of analytes. For first objective, mild but preferential sorption of a range of analytes has been performed with in-tube solid-phase microextraction (SPME) using polytetrafluoroethylene (PTFE) tubing, and for the second, the eluate from in-tube SPME was subjected to on-fibre SPME using DVB/Caboxen/PDMS (30/50 μm) fibre. Knitting of PTFE tubing created secondary flow pattern that enhanced radial diffusion and retention of organic analytes. Up to 2 mg L−1 of a broad range of substances that are not extracted by PTFE include nitrogen containing aromatic heterocyclic compounds, anilines, phenols and certain organophosphorus pesticides, thus providing a clean extract using this method of sample preparation. The proposed combination of in-tube and on-fibre SPME produced a rectilinear calibration graph over 0.03-150 μg L−1 of a range of analytes using 60 mL of aqueous sample. The overall recovery of analytes was in the range 27-78%. The detection limits were between 6.1 and 21.8 ng L−1. The R.S.D. was in range 5.4-8.2% and 4.2-6.5% in the analysis of respectively 2 and 20 μg L−1 of analytes.  相似文献   

20.
A procedure involving the simultaneous performance of liquid–liquid microextraction and polypropylene microporous membrane solid-phase extraction was carried out. The applicability of the proposed procedure was evaluated through extraction of several organochlorine pesticides from river water, tomato and strawberry samples. The parameters affecting the extraction efficiency were optimized by multivariable designs, and the analytical features were estimated. Under optimized conditions, analytes were concentrated onto 1.5 cm long microporous membranes placed directly into the sample containing 15 mL of water with 20 μL of 1-octanol. The best extraction conditions were achieved at 59 °C, with 60 min of extraction time and 2.91 g of sodium chloride. The desorption of the analytes was carried out using 30 μL of a mixture of toluene and hexane in the proportion of 60:40% (v/v) for 10 min. Detection limits in the range of 2.7–20.0 ng L−1, 0.50–1.15 μg kg−1, and 1.53–12.77 μg kg−1 were obtained for river water, strawberry and tomato samples, respectively. Good repeatability was obtained for all three sample types. The results suggest that the proposed procedure represents a very simple and low-cost microextraction alternative rendering adequate limits of quantification for the determination of organochlorine pesticides in environmental and food samples.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号