首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Silver (Ag) and gold (Au) nanoparticles impregnated in nylon membrane filters have been proposed as a new solid phase for preconcentration of mercury from natural waters. Water samples were treated with KMnO4 to convert all mercury species to inorganic Hg2+ and this was followed by the reduction of Hg2+ with NaBH4 to elemental Hg0. The determination of Hg was carried out by thermal evaporation of mercury from membrane filters using Zeeman mercury analyzer RA–915+ (Lumex, Russia). This process does not involve any additional sample treatment and sharply reduces risk of samples contamination. The limit of detection (LOD) was found to be 0.04 ng (absolute mass). Relative LOD was 0.4 ng L−1 for 100 mL of water. The method was validated through the analysis of CRM NRCC Tort–2 (Lobster hepatopancreas) and the found value (0.30 ± 0.07 μg g−1) was in good agreement with the certified value (0.27 ± 0.06 μg g−1). High efficiency of Hg accumulation from aqueous phase to membrane filters can be attributed to a large surface area of nanoparticles.  相似文献   

2.
Cold vapor atomic absorption spectrometry (CV-AAS) based on photochemical reduction by exposure to UV radiation is described for the determination of methylmercury and total mercury in biological samples. Two approaches were investigated: (a) tissues were digested in either formic acid or tetramethylammonium hydroxide (TMAH), and total mercury was determined following reduction of both species by exposure of the solution to UV irradiation; (b) tissues were solubilized in TMAH, diluted to a final concentration of 0.125% m/v TMAH by addition of 10% v/v acetic acid and CH3Hg+ was selectively quantitated, or the initial digests were diluted to 0.125% m/v TMAH by addition of deionized water, adjusted to pH 0.3 by addition of HCl and CH3Hg+ was selectively quantitated. For each case, the optimum conditions for photochemical vapor generation (photo-CVG) were investigated. The photochemical reduction efficiency was estimated to be ∼95% by comparing the response with traditional SnCl2 chemical reduction. The method was validated by analysis of several biological Certified Reference Materials, DORM-1, DORM-2, DOLT-2 and DOLT-3, using calibration against aqueous solutions of Hg2+; results showed good agreement with the certified values for total and methylmercury in all cases. Limits of detection of 6 ng/g for total mercury using formic acid, 8 ng/g for total mercury and 10 ng/g for methylmercury using TMAH were obtained. The proposed methodology is sensitive, simple and inexpensive, and promotes “green” chemistry. The potential for application to other sample types and analytes is evident.  相似文献   

3.
A novel non-chromatographic approach for direct speciation of mercury, based on the selective retention inorganic mercury and methylmercury on the inner wall of a knotted reactor by using ammonium diethyl dithiophosphate and dithizone as complexing agents respectively, was developed for flow injection on-line sorption preconcentration coupled with chemical vapor generation non-dispersive atomic fluorescence spectrometry. With the sample pH kept at 2.0, the preconcentration of inorganic mercury on the inner walls of the knotted reactor was carried out based on the exclusive retention of Hg–DDP complex in the presence of methylmercury via on-line merging the sample solution with ammonium diethyl dithiophosphate solution, and selective preconcentration methylmercury was achieved with dithizone instead of ammonium diethyl dithiophosphate. A 15% (v/v) HCl was introduced to elute the retained mercury species and merge with KBH4 solution for atomic fluorescence spectrometry detection. Under the optimal experimental conditions, the sample throughputs of inorganic mercury and methylmercury were 30 and 20 h 1 with the enhancement factors of 13 and 24. The detection limits were found to be 3.6 ng l 1 for Hg2+ and 2.0 ng l 1 for CH3Hg+. The precisions (RSD) for the 11 replicate measurements of each 0.2 μg l 1 of Hg2+ and CH3Hg+ were 2.2% and 2.8%, respectively. The developed method was validated by the analysis of certified reference materials (simulated natural water, rice flour and pork) and by recovery measurements on spiked samples, and was applied to the determination of inorganic mercury and methylmercury in biological and environmental water samples.  相似文献   

4.
A rapid and efficient closed vessel microwave-assisted extraction (MAE) method based on acidic leaching was developed and optimized for the extraction of total mercury (Hg), inorganic mercury (Hg2+) and methylmercury (CH3Hg+) from fish tissues. The quantitative extraction of total Hg and mercury species from biological samples was achieved by using 5 mol L−1 HCl and 0.25 mol L−1 NaCl during 10 min at 60 °C. Total Hg content was determined using inductively coupled plasma mass spectrometry (ICP-MS). Mercury species were measured by liquid chromatography hyphenated with inductively coupled plasma mass spectrometry (LC-ICP-MS). The method was validated using biological certified reference materials ERM-CE464, DOLT-3, and NIST SRM-1946. The analytical results were in good agreement with the certified reference values of total Hg and CH3Hg+ at a 95% confidence level. Further, accuracy validation using speciated isotope-dilution mass spectrometry (SIDMS, as described in the EPA Method 6800) was carried out. SIDMS was also applied to study and correct for unwanted species transformation reactions during and/or after sample preparation steps. For the studied reference materials, no statistically significant transformation between mercury species was observed during the extraction and determination procedures. The proposed method was successfully applied to fish tissues with good agreement between SIDMS results and external calibration (EC) results. Interspecies transformations in fish tissues were slightly higher than certified reference materials due to differences in matrix composition. Depending on the type of fish tissue, up to 10.24% of Hg2+ was methylated and up to 1.75% of CH3Hg+ was demethylated to Hg2+.  相似文献   

5.
《中国化学快报》2020,31(10):2814-2818
An innovative method for the ultrasensitive detection of mercury by solution anode glow discharge atomic emission spectroscopy (SAGD-AES) coupled with hydride generation (HG) was first investigated. In this method, the mercury vapor generated by the HG was transmitted to the SAGD through the miniature hollow tungsten tube for excitation and detected by a miniaturized spectrograph. A thorough parametric evaluation of the HG and SAGD system was performed, including the type and concentration of carrier acid, He flow rate, concentrations of NaBH4, discharge current and discharge gap. Under optimal operating conditions, the detection limit for Hg2+ achieved 0.03 μg/L, with a relative standard deviation of 1.1% at the Hg2+ concentration of 5 μg/L. Moreover, the correlation coefficient of the calibration curve was 0.9996 in the range between 0.1 and 10 μg/L. The accuracy and practicability of HG-SAGD-AES were verified by measuring GBW09101b (human hair), GBW10029 (fish), soil and rice samples. The results showed good agreement with the certified values and values from direct mercury analyzer (DMA).  相似文献   

6.
A novel method based on photo-induced chemical vapor generation (CVG) as interface to on-line coupled Hg-cysteine ion chromatograpy (IC) with atomic fluorescence spectrometry (AFS) was developed for rapid determination of methylmercury (MHg) in seafood. Separation of inorganic mercury (Hg2+) and methylmercury(CH3Hg+) was accomplished on a Hamilton PRP X-200 polymer-based exchange column with a mobile of 3% acetonitrile, 1% (w/w) L-cysteine and 20 mmol L− 1 pyridine and 160 mmol L− 1 formic acid, at pH 2.4 within 7 min. Once separated, both species are reduced by formic acid in mobile phase under UV radiation to convert Hg0 on-line, which is subsequently swept (by argon carrier gas) into an atomic fluorescence spectrometry (AFS) for measurement. Under the optimized experiment conditions, the detection limits (as Hg), based on three times the standard deviation of a standard solution, were found to be 0.1 ng mL− 1 for mercury and 0.08 ng mL− 1 for methylmercury, with an injection volume of 100 μL. The developed method was validated by determination of certified reference material DORM-2 and was further applied in determination of seafood samples.  相似文献   

7.
Summary Sorption of inorganic mercury (Hg2+) and methyl mercury, on chemically synthesized polyaniline, in 0.1-10N HCl solutions has been studied. Hg2+ is strongly sorbed at low acidities and the extent of sorption decreases with increase in acidity. The sorption of methyl mercury is very low in the HCl concentration range studied. Sorption of Hg2+ on polyaniline in 0.1-10N LiCl and H2SO4 solutions has also been studied. The analysis of the data indicates that the sorption of Hg2+ depends on the degree of protonation of polyaniline and the nature of mercury(II) chloride complexes in solution. X-ray photoelectron spectroscopy analysis (XPS) of polyaniline sorbed with mercury show that mercury is bound as Hg2+. Sorbed mercury is quantitatively eluted from polyaniline with 0.5N HNO3. Polyaniline can be used for separation and pre-concentration of inorganic mercury from aqueous samples.  相似文献   

8.
Cold vapor generation arising from reduction of both Hg2+ and CH3Hg+ occurs using ultrasonic (US) fields of sufficient density to achieve both localized heating as well as radical-based attack in solutions of formic and acetic acids and tetramethylammonium hydroxide (TMAH). A batch sonoreactor utilizing an ultrasonic probe as an energy source and a flow through system based on a US bath were optimized for this purpose. Reduction of CH3Hg+ to Hg0 occurs only at relatively high US field density (>10 W cm−3 of sample solution) and is thus not observed when a conventional US bath is used for cold vapor generation. Speciation of mercury is thus possible by altering the power density during the measurement process. Thermal reduction of Hg2+ is efficient in formic acid and TMAH at 70 °C and occurs in the absence of the US field. Room temperature studies with the batch sonoreactor reveal a slow reduction process, producing temporally broad signals having an efficiency of approximately 68% of that arising from use of a conventional SnCl2 reduction system. Molecular species of mercury are generated at high concentrations of formic and acetic acid. Factors affecting the generation of Hg0 were optimized and the batch sonoreactor used for the determination of total mercury in SLRS-4 river water reference material.  相似文献   

9.
A simple and sensitive method to determine Hg2+ was developed by combining solution-cathode glow discharge atomic emission spectrometry (SCGD-AES) with flow injection (FI) based on on-line solid-phase extraction (SPE). We synthesized l-cysteine-modified mesoporous silica and packed it in an SPE microcolumn, which was experimentally determined to possess a good mercury adsorption capacity. An enrichment factor of 42 was achieved under optimized Hg2+ elution conditions, namely, an FI flow rate of 2.0 mL min−1 and an eluent comprised of 10% thiourea in 0.2 mol L−1 HNO3. The detection limit of FI–SCGD-AES was determined to be 0.75 μg L−1, and the precision of the 11 replicate Hg2+ measurements was 0.86% at a concentration of 100 μg L−1. The proposed method was validated by determining Hg2+ in certified reference materials such as human hair (GBW09101b) and stream sediment (GBW07310).  相似文献   

10.
This work reports the development of a dispersive liquid – liquid microextraction method for the simultaneous extraction, preconcentration, and derivatization of Hg2+ and CH3Hg+ species from water samples for further determination by GC – MS. Some parameters of the proposed method, such as volume and type of disperser and extraction solvent, and Na[B(C6H5)4] concentration were investigated using response surface methodology. Suitable recoveries were obtained using 80 μL C2Cl4 (as extraction solvent), 1000 μL ethanol (as disperser solvent), and 300 μL 2.1 mmol/L Na[B(C6H5)4] (as derivatizing agent). Accuracy was evaluated in terms of recovery and ranged from 87 to 99% with RSD values <7%. In addition, a certified reference material of water (NIST 1641d) was analyzed and agreed with the certified value about 107% (for Hg2+), with RSD values <8.5%. LODs were 0.3 and 0.2 μg/L, with enrichment factors of 112 and 115 for Hg2+ and CH3Hg+, respectively. The optimized method was applied for the determination of Hg2+ and CH3Hg+ in tap, well, and lake water samples.  相似文献   

11.
The river Elbe has been one of the most contaminated rivers with regard to mercury for many years. In 1991 a length-profile has been measured for mercury and methylmercury (CH3Hg+) from Obristvi, Czech Republic, to the German bight. Total mercury has been measured by cold vapor atomic absorption spectrometry (CVAAS). The organo mercury compounds have been separated by high performance liquid chromatography (HPLC) connected on-line to an atomic fluorescence spectrometer (AFS) by a continuous flow-system. Total mercury up to 120 mg Hg+/kg and CH3Hg+ concentrations up to 130 μg CH3 Hg+/kg could be detected in special sites. The formation of CH3Hg+ in sediments can be caused besides the methylation of mercury, by sulphate reducing or methanogenic bacteria and transmethylation reactions with organometals. Atmospheric mercury concentrations have been measured at three different European sites. Samples have been collected on goldcoated glass balls or on quartz wool, respectively. After thermal desorption mercury has been determined using the two step amalgamation technique with AFS detection. Compared to natural background concentrations of total gaseous mercury (TGM), slightly increased levels could be detected at a rural site in Germany. This increase can probably be explained by long-range transport processes. Within the vicinity of a inactivated mercury production plant high concentrations of up to 13.5 ng/m3 particle associated mercury (Hgpart) have been detected. Consequently, dry deposition of mercury in the particulate form can intensify the total deposition flux close to Hg-emitting sources.  相似文献   

12.
Applicability of polyaniline (PANI) has been investigated for the preconcentration and speciation of inorganic mercury (Hg2+) and methyl mercury (CH3Hg+) in various waters (ground, lake and sea waters). Preliminary experiments (batch) with powdered PANI for the quantitative removal of both Hg2+ and CH3Hg+ showed that the retention of Hg2+ was almost independent of pH while a pH dependent trend from pH 1 to 12 was seen for CH3Hg+ with maximum retention at pH > 5. Time dependence batch studies showed that a contact time of 10 min was sufficient to reach equilibrium. The Kd values were found to be ∼8 × 104 and ∼7 × 103 for Hg2+ and CH3Hg+, respectively.Subsequently column experiments were carried out with PANI and the separation of the species was carried out by selective and sequential elution with 0.3% HCl for CH3Hg+ and 0.3% HCl-0.02% thiourea for Hg2+. This was then followed by further pre-concentration of mercury on a gold trap and its determination by CVAAS. The uptake efficiency studies showed that the PANI column was able to accumulate up to 100 mg Hg2+/g and 2.5 mg CH3Hg+/g. This method allows both preconcentration and speciation of mercury with preconcentration factors around 120 and 60 for Hg2+ and CH3Hg+, respectively. The interfering effects of various foreign substances on the retention of mercury were investigated.  相似文献   

13.
The dispersive liquid-liquid microextraction (DLLME) combined with high performance liquid chromatography-inductively coupled plasma mass spectrometry for the speciation of mercury in water samples was described. Firstly methylmercury (MeHg+) and mercury (Hg2+) were complexed with sodium diethyldithiocarbamate, and then the complexes were extracted into carbon tetrachloride by using DLLME. Under the optimized conditions, the enrichment factors of 138 and 350 for MeHg+ and Hg2+ were obtained from only 5.00 mL sample solution. The detection limits of the analytes (as Hg) were 0.0076 ng mL−1 for MeHg+ and 0.0014 ng mL−1 for Hg2+, respectively. The relative standard deviations for ten replicate measurements of 0.5 ng mL−1 MeHg+ and Hg2+ were 6.9% and 4.4%, respectively. Standard reference material of seawater (GBW(E)080042) was analyzed to verify the accuracy of the method and the results were in good agreement with the certified values. Finally, the developed method was successfully applied for the speciation of mercury in three environmental water samples.  相似文献   

14.
A field-adapted procedure based on species-specific isotope dilution (SSID) methodology for trace-level determinations of methyl mercury (CH3Hg+) in mire, fresh and sea water samples was developed, validated and applied in a field study. In the field study, mire water samples were filtered, standardised volumetrically with isotopically enriched CH3200Hg+, and frozen on dry ice. The samples were derivatised in the laboratory without further pre-treatment using sodium tetraethyl borate (NaB(C2H5)4) and the ethylated methyl mercury was purge-trapped on Tenax columns. The analyte was thermo-desorbed onto a GC-ICP-MS system for analysis. Investigations preceding field application of the method showed that when using SSID, for all tested matrices, identical results were obtained between samples that were freeze-preserved or analysed unpreserved. For DOC-rich samples (mire water) additional experiments showed no difference in CH3Hg+ concentration between samples that were derivatised without pre-treatment or after liquid extraction. Extractions of samples for matrix–analyte separation prior to derivatisation are therefore not necessary. No formation of CH3Hg+ was observed during sample storage and treatment when spiking samples with 198Hg2+. Total uncertainty budgets for the field application of the method showed that for analyte concentrations higher than 1.5 pg g–1 (as Hg) the relative expanded uncertainty (REU) was approximately 5% and dominated by the uncertainty in the isotope standard concentration. Below 0.5 pg g–1 (as Hg), the REU was >10% and dominated by variations in the field blank. The uncertainty of the method is sufficiently low to accurately determine CH3Hg+ concentrations at trace levels. The detection limit was determined to be 4 fg g–1 (as Hg) based on replicate analyses of laboratory blanks. The described procedure is reliable, considerably faster and simplified compared to non-SSID methods and thereby very suitable for routine applications of CH3Hg+ speciation analysis in a wide range of water samples.  相似文献   

15.
Although many plasmonic nanosenosrs have been established for the detection of mercury(Ⅱ)(Hg2+),few of them is feasible for analyzing natural samples with very complex matrices because of insufficient method selectivity.To address this challenge,we propose an epitaxial and lattice-mismatch approach to the synthesis of a unique Au/Ag2S dimeric nanostructure,which consists of an Au segment with excellent plasmonic characteristics,and a highly stable Ag2S portion wi...  相似文献   

16.
In order to reveal the time-depending mercury species uptake by human astrocytes, a novel approach for total mercury analysis is presented, which uses an accelerated sample introduction system combined on-line with an inductively coupled plasma mass spectrometer equipped with a collision/reaction cell. Human astrocyte samples were incubated with inorganic mercury (HgCl2), methylmercury chloride (MeHgCl), and thimerosal. After 1-h incubation with Hg2+, cellular concentrations of 3 μM were obtained, whereas for organic species, concentrations of 14–18 μM could be found. After 24 h, a cellular accumulation factor of 0.3 was observed for the cells incubated with Hg2+, whereas the organic species both showed values of about 5. Due to the obtained steady-state signals, reliable results with relative standard deviations of well below 5 % and limits of detection in the concentration range of 1 ng L?1 were obtained using external calibration and species-unspecific isotope dilution analysis approaches. The results were further validated using atomic fluorescence spectrometry.
Figure
?  相似文献   

17.
A simple and inexpensive laboratory-built flow injection vapor generation system coupled to atomic absorption spectrometry (FI-VG AAS) for inorganic and total mercury determination has been developed. It is based on the vapor generation of total mercury and a selective detection of Hg2 + or total mercury by varying the temperature of the measurement cell. Only the inorganic mercury is measured when the quartz cell is at room temperature, and when the cell is heated to 650 °C or higher the total Hg concentration is measured. The organic Hg concentration in the sample is calculated from the difference between the total Hg and Hg2 + concentrations. Parameters such as the type of acid (HCl or HNO3) and its concentration, reductant (NaBH4) concentration, carrier solution (HCl) flow rate, carrier gas flow rate, sample volume and quartz cell temperature, which influence FI-VG AAS system performance, were systematically investigated. The optimized conditions for Hg2 + and total Hg determinations were: 1.0 mol l 1 HCl as carrier solution, carrier flow rate of 3.5 ml min 1, 0.1% (m/v) NaBH4, reductant flow rate of 1.0 ml min 1 and carrier gas flow rate of 200 ml min 1. The relative standard deviation (RSD) is lower than 5.0% for a 1.0 μg l 1 Hg solution and the limit of quantification (LOQ, 10 s) is 55 ng g 1. Certified samples of dogfish muscle (DORM-1 and DORM-2) and non-certified fish samples were analyzed, using a 6.0 mol l 1 HCl solution for analyte extraction. The Hg2 + and CH3Hg+ concentrations found were in agreement with certified ones.  相似文献   

18.
A new method for solid-phase extraction and preconcentration of trace mercury(II) from aqueous solution was developed using 1,5-diphenylcarbazide doped magnetic Fe3O4 nanoparticles as extractant. The surface treatment did not result in the phase change of Fe3O4. Various factors which influenced the recovery of the analyte were investigated using model solutions and batch equilibrium technique. The maximum adsorption occurred at pH?>?6, and equilibrium was achieved within 5 min. Without filtration or centrifugation, these mercury loaded nanoparticles could be separated easily from the aqueous solution by simply applying an external magnetic field. At optimal conditions, the maximum adsorption capacity was 220 μmol g?1. The mercury ions can be eluted from the composite magnetic particles using 0.5 mol L?1 HNO3 as a desorption reagent. The detection limit of the method (3σ) was 0.16 μg L?1 for cold vapor atomic absorption spectrometry, and the relative standard deviation was 2.2%. The method was validated by the analysis of a certified reference material with the results being in agreement with those quoted by manufactures. The method was applied to the preconcentration and determination of trace inorganic mercury(II) in natural water and plant samples with satisfactory results.  相似文献   

19.
Lu J  He X  Zeng X  Wan Q  Zhang Z 《Talanta》2003,59(3):553-560
A novel calix[4]arene derivative containing benzothiazole group was coated on glassy carbon electrode (GCE) and then applied to the recognition of mercury ion. Cyclic and square wave voltammetric results showed that the modified electrode selectively recognizes Hg2+ ion in aqueous media. A new anodic stripping peak at −0.3 V (vs. Ag/Ag+) can be obtained by scanning the potential from −0.6 to 0.6 V, and the peak currents are proportional to the Hg2+ concentration. The modified electrode in a 0.1 M H2SO4+0.01 M NaCl solution shows linear voltammetric response in the range of 25-300 μg l−1 and detection limit of 5 μg l−1 (ca. 2.5×10−8 M). This modified GCE does not present any significant interference from alkali, alkaline and transition metal ions except for Pb2+, Ag+ and Cu2+ ions. Only 500, 50 and 100-fold molar excess of Pb2+, Ag+ and Cu2+ ions, respectively, can lead to voltammetric response comparable with that of Hg2+. The proposed method was successfully applied to determine mercury in natural water.  相似文献   

20.
A simple non-chromatographic method for the determination of mercury (Hg2+), methylmercury (MeHg+), dimethylmercury (Me2Hg), and phenylmercury (PhHg+) employing atomic fluorescence spectrometry (AFS) as detection technique was developed. Mercury species showed a particular behavior in the presence of several reagents. In a first stage SnCl2 was employed for Hg2+ determination; in a second step, [Hg2+ + PhHg+] concentration was determined using SnCl2 and UV radiation. MeHg+ decomposition was prevented adding 2-mercaptoethanol. In a third stage, [Hg2+ + PhHg+ + MeHg+] concentration was determined using K2S2O8. Finally, the four species were determined employing NaBH4. Reagents concentration and flow rates were optimized. The extraction technique of mercury species involved the use of 2-mercaptoethanol as ion-pair reagent. The limits of detection for Hg2+, PhHg+, MeHg+, and Me2Hg were 1, 40, 68, and 99 ng L−1 with a relative standard deviation of 1.5, 3.1, 4.7 and 5.8%, respectively. Calibration curve was linear with a correlation factor equal to 0.9995. The method was successfully applied to the determination of the mercury species in two Antarctic materials: IRMM 813 (Adamussium colbecki) and MURST-ISS-A2 (Antarctic Krill).  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏