共查询到20条相似文献,搜索用时 109 毫秒
1.
Nording M Nichkova M Spinnel E Persson Y Gee SJ Hammock BD Haglund P 《Analytical and bioanalytical chemistry》2006,385(2):357-366
Since soils at industrial sites might be heavily contaminated with polychlorinated dibenzo-p-dioxins (PCDDs) and polychlorinated dibenzofurans (PCDFs), there is a need for large-scale soil pollution surveys and, thus,
for cost-efficient, high-throughput dioxin analyses. However, trace analysis of dioxins in complex matrices requires exhaustive
extraction, extensive cleanup, and very sensitive detection methods. Traditionally, this has involved the use of Soxhlet extraction
and multistep column cleanup, followed by gas chromatography—high-resolution mass spectrometry (GC/HRMS), but bioanalytical
techniques may allow much more rapid, cost-effective screening. The study presented here explores the possibility of replacing
the conventional method with a novel approach based on simultaneous accelerated solvent extraction (ASE) and purification,
followed by an enzyme-linked immunosorbent assay (ELISA). Both the traditional and the novel cleanup and detection approaches
were applied to contaminated soil samples, and the results were compared. ELISA and GC/HRMS results for Soxhlet-extracted
samples were linearly correlated, although the ELISA method slightly underestimated the dioxin levels. To avoid an unacceptable
rate of false-negative results, the use of a safety factor is recommended. It was also noted that the relative abundance of
the PCDDs/PCDFs, evaluated by principal component analysis, had an impact on the ELISA performance. To minimize this effect,
the results may be corrected for differences between the ELISA cross-reactivities and the corresponding toxic equivalency
factor values. Finally, the GC/HRMS and ELISA results obtained following the two sample preparation methods agreed well; and
the ELISA and GC/HRMS results for ASE extracts were strongly correlated (correlation coefficient, 0.90). Hence, the ASE procedure
combined with ELISA analysis appears to be an efficient approach for high-throughput screening of PCDD-/PCDF-contaminated
soil samples.
相似文献
2.
Campos-Candel A Llobat-Estellés M Mauri-Aucejo AR 《Analytical and bioanalytical chemistry》2007,387(4):1517-1523
A procedure for the determination of benzene, toluene, ethylbenzene and o-xylene, m-xylene and p-xylene (BTEX) in occupational environments is proposed. These compounds are extracted from activated charcoal using accelerated
solvent extraction. Operational parameters are optimized and quantitative recovery is obtained using acetonitrile as the extraction
solvent and 1-mL extraction cells, a preheat time of 2 min, a temperature of 160 °C, a pressure of 1,500 psi, a static period
of 5 min, a flush volume of 110%, two cycles and a purge time of 90 s. Determination of BTEX compounds is carried out by gas
chromatography using a flame ionization detector. The recoveries, obtained for a confidence level of 95%, are 91 ± 4, 100 ± 3,
104 ± 2, 93 ± 4, 99 ± 2 and 99 ± 2% for benzene, toluene, ethylbenzene, o-xylene, m-xylene and p-xylene, respectively. The detection limits are 0.5 μg for benzene, 0.7 μg for toluene and 1.0 μg for the other compounds.
The proposed procedure has been applied to real samples collected in several workplaces, like a microbiology laboratory, an
analytical chemistry laboratory, a printer’s, a car repair shop and a petrol station. From the results obtained, it can be
concluded that the occupational exposures determined are always acceptable because they are lower than the tenth part of the
recommended exposure limits (VLA-ED and VLA-EC). 相似文献
3.
A method was developed to determine eight acetanilide herbicides from cereal crops based on accelerated solvent extraction (ASE) and solid-phase extraction (SPE) followed by gas chromatography-electron capture detector (GC-ECD) analysis. During the ASE process, the effect of four parameters (temperature, static time, static cycles and solvent) on the extraction efficiency was considered and compared with shake-flask extraction method. After extraction with ASE, four SPE tubes (graphitic carbon black/primary secondary amine (GCB/PSA), GCB, Florisil and alumina-N) were assayed for comparison to obtain the best clean-up efficiency. The results show that GCB/PSA cartridge gave the best recoveries and cleanest chromatograms. The analytical process was validated by the analysis of spiked blank samples. Performance characteristics such as linearity, limit of detection (LOD), limit of quantitation (LOQ), precision and recovery were studied. At 0.05 mg/kg spiked level, recoveries and precision values for rice, wheat and maize were 82.3-115.8 and 1.1-13.6%, respectively. For all the herbicides, LOD and LOQ ranged from 0.8 to 1.7 μg/kg and from 2.4 to 5.3 μg/kg, respectively. The proposed analytical methodology was applied for the analysis of the targets in samples; only three herbicides, propyzamid, metolachlor and diflufenican, were detected in two samples. 相似文献
4.
Terpenes, e. g. (+)-alpha-pinene, (-)-camphene, (-)-(-pinene, myrcene, R-(+)-limonene, eucalyptol, (+/-)-linalool, (-)-bornyl acetate, (-)-trans-caryophyllene, and alpha-humulene were determined in leaves of walnut trees from the Juglandaceae family (walnut tree, royal (J. regia L.), black (J. nigra L.), and Siebold (J. sieboldiana, var. Cordiformis Lam.) using gas chromatography with mass spectrometric detection. Terpenes were repeatedly (3 cycles, 5 min each) extracted from leaves of walnut trees by accelerated (pressurized) solvent extraction (ASE) 150 bar and 120 degrees C. The efficiency of ASE extraction was superior to that of steam distillation, solvent extraction according to Soxhlet, sonication, and extraction by agitation. Differences in relative concentrations and distribution of terpenes were studied in dependence on the species of walnut tree and on different locations. 相似文献
5.
The performance of accelerated solvent extraction in the analysis of terpenoids and sterols in tobacco samples was investigated
and compared with those of Soxhlet extraction and ultrasonically assisted extraction with respect to yield, extraction time,
reproducibility and solvent consumption. The results indicate that although the highest yield was achieved by Soxhlet extraction,
ASE appears to be a promising alternative to classical methods since it is faster and uses less solvent, especially when applied
to the investigation of large batch tobacco samples. However, Soxhlet extraction is still the preferred method for analyzing
sterols since it gives a higher extraction efficiency than other methods. 相似文献
6.
Determination of pharmaceuticals in biosolids using accelerated solvent extraction and liquid chromatography/tandem mass spectrometry 总被引:1,自引:0,他引:1
An analytical method was developed to quantitatively determine pharmaceuticals in biosolid (treated sewage sludge) from wastewater treatment plants (WWTPs). The collected biosolid samples were initially freeze dried, and grounded to obtain relatively homogenized powders. Pharmaceuticals were extracted using accelerated solvent extraction (ASE) under the optimized conditions. The optimal operation parameters, including extraction solvent, temperature, pressure, extraction time and cycles, were identified to be acetonitrile/water mixture (v/v 7:3) as extraction solvent with 3 extraction cycles (15 min for each cycle) at 100 °C and 100 bars. The extracts were cleaned up using solid-phase extraction followed by determination by liquid chromatography coupled with tandem mass spectrometry. For the 15 target pharmaceuticals commonly found in the environment, the overall method recoveries ranged from 49% to 68% for tetracyclines, 64% to 95% for sulfonamides, and 77% to 88% for other pharmaceuticals (i.e. acetaminophen, caffeine, carbamazepine, erythromycin, lincomycin and tylosin). The developed method was successfully validated and applied to the biosolid samples collected from WWTPs located in six cities in Michigan. Among the 15 target pharmaceuticals, 14 pharmaceuticals were detected in the collected biosolid samples. The average concentrations ranged from 2.6 μg/kg for lincomycin to 743.6 μg/kg for oxytetracycline. These results indicated that pharmaceuticals could survive wastewater treatment processes, and accumulate in sewage sludge and biosolids. Subsequent land application of the contaminated biosolids could lead to the dissemination of pharmaceuticals in soil and water environment, which poses potential threats to at-risk populations in the receiving ecosystems. 相似文献
7.
8.
Accelerated solvent extraction (ASE) of vanilla beans has been optimized using ethanol as a solvent. A theoretical model is proposed to account for this multistep extraction. This allows the determination, for the first time, of the total amount of analytes initially present in the beans and thus the calculation of recoveries using ASE or any other extraction technique. As a result, ASE and Soxhlet extractions have been determined to be efficient methods, whereas recoveries are modest for maceration techniques and depend on the solvent used. Because industrial extracts are obtained by many different procedures, including maceration in various solvents, authenticating vanilla extracts using quantitative ratios between the amounts of vanilla flavor constituents appears to be unreliable. When authentication techniques based on isotopic ratios are used, ASE is a valid sample preparation technique because it does not induce isotopic fractionation. 相似文献
9.
Olatz Zuloaga Nestor Etxebarria Luis A. Fernndez Juan M. Madariaga 《Trends in analytical chemistry : TRAC》1998,17(10):642-647
The extraction and determination of chlorinated biphenyls (CBs) in soils and solid wastes is an ongoing subject of study. This is an overview article that compares the microwave-assisted extraction (MAE) and accelerated solvent extraction (ASE) techniques. The extraction of CBs by ASE has been optimised taking into account the variation of pressure, temperature and extraction time by means of experimental design and the Simplex approach. The recoveries obtained under the optimum conditions are compared and discussed with those obtained from MAE and Soxhlet extractions. 相似文献
10.
The methods of simultaneous extraction of polycyclic aromatic hydrocarbons (PAHs) and organochlorine pesticides (OCPs) from soils using Soxhlet extraction, microwave-assisted extraction (MAE) and accelerated solvent extraction (ASE) were established, and the extraction efficiencies using the three methods were systemically compared from procedural blank, limits of detection and quantification, method recovery and reproducibility, method chromatogram and other factors. In addition, soils with different total organic carbon contents were used to test the extraction efficiencies of the three methods. The results showed that the values obtained in this study were comparable with the values reported by other studies. In some respects such as method recovery and reproducibility, there were no significant differences among the three methods for the extraction of PAHs and OCPs. In some respects such as procedural blank and limits of detection and quantification, there were significant differences among the three methods. Overall, ASE had the best extraction efficiency compared to MAE and Soxhlet extraction, and the extraction efficiencies of MAE and Soxhlet extraction were comparable to each other depending on the property such as TOC content of the studied soil. Considering other factors such as solvent consumption and extraction time, ASE and MAE are preferable to Soxhlet extraction. 相似文献
11.
Pu Wang Yawei Wang Thanh Wang Xiaomin Li Lei Ding Guibin Jiang 《Analytica chimica acta》2010,663(1):43-7247
Three commonly applied extraction techniques for persistent organic chemicals, Soxhlet extraction (SE), accelerated solvent extraction (ASE) and microwave-assisted extraction (MAE), were applied on soil and fish samples in order to evaluate their performances. For both PCBs and PBDEs, the two more recent developed techniques (ASE and MAE) were in general capable of producing comparable extraction results as the classical SE, and even higher extraction recoveries were obtained for some PCB congeners with large octanol-water partitioning coefficients (Kow). This relatively uniform extraction results from ASE and MAE indicated that elevated temperature and pressure are favorable to the efficient extraction of PCBs from the solid matrices. For PBDEs, difference between the results from MAE and ASE (or SE) suggests that the MAE extraction condition needs to be carefully optimized according to the characteristics of the matrix and analyte to avoid degradation of higher brominated BDE congeners and improve the extraction yields. 相似文献
12.
Jin-Shui Che Rui-Peng Yu Li-Ping Wang Sheng-Fang Wu 《International journal of environmental analytical chemistry》2013,93(4):387-399
Synthetic musks, substitutes for natural musks, are widely distributed in environment. They have been detected in water, sludge, fish, shrimp, mussels and other aquatic animals, and even in human's adipose tissue, blood and breast milk. In this study, a new extraction procedure, based on the accelerated solvent extraction (ASE) and in cell clean-up technique was developed and successfully coupled with gas chromatography-mass spectrometry (GC/MS) for the analysis of musks in sediment samples. With this method, the limits of detection as low as 0.03–0.05?ng?g?1 and the recovery rate of 86.0%–104% are achieved. When compared with soxhlet extraction (SE) and ultrasonic extraction (USE), ASE not only has the best extraction efficiency but also has advantage in extraction time and solvent consumption. Eight synthetic musks, including six polycyclic musks (Tonalide (AHTN), Galaxolide (HHCB), Phantolide (AHDI), Traseolide (ATII), Cashmeran (DPMI) and Celestolide (ADBI)) and two nitro musks (musk xylene (MX) and musk ketone (MK)), were evaluated in sediment samples collected from 15 selected locations of the Taihu lake, one of the largest freshwater lakes in China. The contents of synthetic musks in sediment samples range from 0.336 to 3.10?ng?g?1 for HHCB, 0.184 to 1.21?ng?g?1 for AHTN, below detection limit (BDL) to 0.349?ng?g?1 for MX, and BDL to 0.0786?ng?g?1 for MK. The contents of DPMI, ADBI, AHMI and ATII are below detection limit in all samples. The results reflect current status of fragrance compound pollution in this area, and provide basic data for environmental policy making. 相似文献
13.
Fernández-González V Grueiro-Noche G Concha-Graña E Turnes-Carou MI Muniategui-Lorenzo S López-Mahía P Prada-Rodríguez D 《Analytical and bioanalytical chemistry》2005,383(2):174-181
The blank extracts obtained from the pressurized liquid extraction (PLE) of a 11 mL empty cell of ASE 200 were analysed by
GC-FID and GC-ECD and many interfering peaks were detected, which could difficult the trace analysis of persistent organic
pollutants (i.e. polycyclic aromatic hydrocarbons, aliphatic hydrocarbons and organochlorine pesticides). These interfering
compounds were identified as phthalates, silicones and organic acids and their sources were established. A solution to this
analytical trouble is a previous extraction step of the empty cell under the same conditions optimised for the sample extraction. 相似文献
14.
15.
加速溶剂萃取-固相萃取净化-气相色谱-串联质谱法检测茶叶中9种拟除虫菊酯类农药残留 总被引:3,自引:0,他引:3
建立了加速溶剂萃取(ASE)-固相萃取净化(SPE)-气相色谱-串联质谱(GC-MS/MS)同时测定茶叶中9种拟除虫菊酯类农药残留的方法。ASE萃取溶剂为丙酮-正己烷(1:1,v/v),萃取温度为100℃,萃取压力为10 MPa,加热时间为3 min,静态萃取时间为5 min,循环1次,冲洗体积为40%萃取池体积,氮气吹扫100 s。萃取结束后用Cleanert TPT固相萃取柱净化,净化液浓缩定容后,采用GC-MS/MS测定,外标法定量。9种拟除虫菊酯类农药在2~1000 μg/L范围内呈现良好的线性关系,相关系数(r2)均大于0.99,方法检出限为0.2~4.5 μg/kg,定量限为0.8~15.0 μg/kg。在绿茶、红茶空白基质中做加标回收试验,添加水平为0.02、0.1、0.4 mg/kg以及定量限水平,得到的平均回收率为69.87%~110.0%,相对标准偏差(RSD)为0.7%~11.2%。该方法背景干扰低、灵敏度高、重现性好、回收率稳定,适用于茶叶中拟除虫菊酯类农药残留量的检测。 相似文献
16.
Rapid determination of trace polycyclic aromatic hydrocarbons in particulate matter using accelerated solvent extraction followed by ultra high performance liquid chromatography with fluorescence detection 下载免费PDF全文
Tianci Xu 《Journal of separation science》2016,39(10):1892-1899
A method has been developed for the trace analysis of polycyclic aromatic hydrocarbons, which are known as persistent organic pollutants and ubiquitous constituents of fine particulate matter that causes growing airborne pollution. The method, which was especially for samples of airborne particulate matter less than 2.5 μm in diameter, utilized accelerated solvent extraction and ultra high performance liquid chromatography with fluorescence detector. Four principal parameters of accelerated solvent extraction were optimized to obtain maximum extraction efficiency. Using the established synergetic programs of gradient elution and fluorescence wavelength switching, a rapid separation was achieved in 6.56 min with good linearity for 15 polycyclic aromatic hydrocarbons (coefficient of determination above 0.999). The limits of detection ranged from 0.833 to 10.0 pg/m3. The precision of the method expressed as inter‐day relative standard deviation ranged from 0.2 to 1%, which was calculated from nine repetitive measurements of 8.00 μg/L analytes. Average spiked recoveries ranged from 71.6 to 97.7%, with the exception of naphthalene. The rapid, sensitive, and accurate method can meet the pressing needs of health risk assessment and increasingly heavy daily tasks of air quality monitoring. 相似文献
17.
加速溶剂萃取-气相色谱-负化学源质谱法测定茶叶中有机氯和拟除虫菊酯类农药残留量 总被引:6,自引:0,他引:6
建立了茶叶中13种有机氯和10种拟除虫菊酯农药残留量的气相色谱-负化学离子源.质谱(GC-NCl-MS)分析方法.茶叶样品用V(丙酮):V(CH2Cl2)=1:1混合液作提取剂经加速溶剂萃取,提取液经凝胶色谱净化除去大部分的色素、脂类和蜡质,再经活性炭-氨基(Carb-NH2)复合小柱和Florisil小柱净化后,用GC-NCl-MS的选择离子监测方式(SIM)进行定性和定量分析.添加50μg/kg 浓度水平时,农药回收率在45.6%~112.4%之间,相对标准偏差在0.57%~10.1%之间;方法的检出限(3倍信噪比)在0.05~10.0μg/kg之间.方法适用于出口茶叶农残检测实际工作. 相似文献
18.
加速溶剂萃取/凝胶渗透色谱-固相萃取净化、气相色谱-质谱法测定茶叶中残留的33种农药 总被引:12,自引:1,他引:12
建立了茶叶中有机磷、有机氯、拟除虫菊酯类共33种农药残留的分析方法。样品以丙酮-二氯甲烷(体积比为1:1)为提取剂经加速溶剂方法萃取,提取液用凝胶渗透色谱净化除去大部分的色素、脂类和蜡质,再用Carb-NH2小柱和Florisil小柱净化。采用气相色谱法分析、外标法定量、气相色谱-质谱法(GC-MS)定性。加标水平为0.05 mg/kg时,大部分农药的回收率为70%~120%,相对标准偏差小于20%。方法的检测限为0.005~0.05 mg/kg (以10倍信噪比计)。该方法的提取效率高,准确灵敏,目前已应用于出口茶叶中农药残留的日常检测。大量实际样品的检测结果表明,此方法适于出口茶叶中农药残留检测实际工作的需要。 相似文献
19.
Determination of PAHs in airborne particles by accelerated solvent extraction and large-volume injection-gas chromatography-mass spectrometry 总被引:2,自引:0,他引:2
A sensitive and automated method is presented for the determination of polycyclic aromatic hydrocarbons (PAHs) in airborne particulate matter. The procedure includes extraction of PM10-bound PAHs by accelerated solvent extraction (ASE) followed by gel permeation chromatography (GPC) clean-up, and large-volume programmable temperature vaporizer (PTV-LV) injection coupled to GC-MS. The limit of detection (LOD) of the whole method, based on a signal-to-noise ratio (S/N) of 3:1, ranged from 0.26 pg m−3 to 3 pg m−3 when air volumes of 760 m3 are collected.The hexane-acetone mixture (1:1, v/v) gave the best recoveries when ASE parameters were fixed at 125 °C, 1500 psi, and a total time of 10 min. The recoveries for all PAHs tested ranged from 96% to 103%, rates similar to those obtained by the Soxhlet reference method.To improve the sensitivity, 70 μL were injected. The PTV-LV injection settings were optimized using a statistical design of experiments, including a screening 24 full factorial design and a further central composite design. A sensitivity increase from 10 to 50 times was achieved as compared with the conventional 2 μL splitless injection.The method was validated with the standard reference material SRM 1649a and applied to real PM10 samples from the monitoring network of the Regional Valencia Government (Spain).The analytical performance of the method shows that it is appropriate to monitor PAHs levels in ambient air according to European Union Directives. In addition, the method can be used when a high sensitivity is required. 相似文献