首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Dielectric fluctuations are shown to be the dominant source of noncontact friction in high-sensitivity scanning probe microscopy of dielectric materials. Recent measurements have directly determined the friction acting on custom-fabricated single-crystal silicon cantilevers whose capacitively charged tips are located 3-200 nm above thin films of poly(methyl methacrylate), poly(vinyl acetate), and polystyrene. Differences in measured friction among these polymers are explained here by relating electric field fluctuations at the cantilever tip to dielectric relaxation of the polymer.  相似文献   

2.
We show that cantilever array sensors can sense the formation of supported phospholipid bilayers on their surface and that they can monitor changes in mechanical properties of lipid bilayers. Supported lipid bilayers were formed on top of microfabricated cantilevers by vesicle fusion. The formation of bilayers led to a bending of the cantilevers of 70-590 nm comparable to a surface stress of 27-224 mN/m. Physisorption of bilayers of DOPC and other bilayers on the silicon oxide surface of cantilevers led to a tensile bending of about 70 nm whereas formation of chemisorbed bilayers of mixed thiolated (DPPTE) and non-thiolated lipids (DOPC) on the gold side of cantilevers led to a compressive bending of nearly 600 nm which depended on the ratio of DPPTE to DOPC. First results on bending of bilayer-covered cantilevers due to their interaction with the pore-forming peptide melittin are shown. The results demonstrate that cantilever sensors with immobilized bilayers can be used as model systems to investigate mechanical properties of cellular membranes and may be used for screening of membrane processes involving modification, lateral expansion, or contraction of membranes.  相似文献   

3.
In this paper we present our first results on the realization of stable water/octanol, two-phase flows inside poly(dimethylsiloxane) (PDMS) microchannels. Native PDMS microchannels were coated with high molecular weight polymers to change the surface properties of the microchannels and thus stabilize the laminar flow profile. The polymers poly(2-hydroxyethyl methacrylate), poly(vinyl pyrrolidone), poly(ethylene oxide), poly(ethylene glycol), and poly(vinyl alcohol) were assessed for their quality as stabilization coatings after deposition from flowing and stationary solutions. Additionally, the influence of coating the microchannels homogeneously with a single kind of polymer or heterogeneously with two different polymers was investigated. From the experimental observations, it can be concluded that homogeneous polymer coatings with poly(2-hydroxyethyl methacrylate) and poly(vinyl pyrrolidone) led to the effective stabilization of laminar water/octanol flows. Furthermore, heterogeneous coatings led to two-phase flows which had a better-defined and more stable interface over long distances (i.e., 40-mm-long microchannels). Finally, the partitioning of fuchsin dye in the coated microchannels was demonstrated, establishing the feasibility of the use of the polymer-coated PDMS microchannels for determination of logP values in laminar octanol/water flows.  相似文献   

4.
A compact and low-power microcantilever-based sensor array has been developed and used to detect various chemical vapor analytes. In contrast to earlier micro-electro-mechanical systems (MEMS) array sensors, this device uses the static deflection of piezoresistive cantilevers due to the swelling of glassy polyolefin coatings during sorption of chemical vapors. To maximize the sensor response to a variety of chemical analytes, the polymers are selected based on their Hildebrand solubility parameters to span a wide range of chemical properties. We utilize a novel microcontact spotting method to reproducibly coat a single side of each cantilever in the array with the polymers. To demonstrate the utility of the sensor array we have reproducibly detected 11 chemical vapors, representing a breadth of chemical properties, in real time and over a wide range of vapor concentrations. We also report the detection of the chemical warfare agents (CWAs) VX and sulfur mustard (HD), representing the first published report of CWA vapor detection by a polymer-based, cantilever sensor array. Comparisons of the theoretical polymer/vapor partition coefficient to the experimental cantilever deflection responses show that, while general trends can be reasonably predicted, a simple linear relationship does not exist.  相似文献   

5.
A detailed kinetic study is provided for the oxidation of ascorbate at poly(aniline)-poly(styrene sulfonate) coated microelectrodes. Flat films with a low degree of polymer spillover and a thickness much lower than the microelectrode radius were produced by controlled potentiodynamic electrodeposition. The currents for ascorbate oxidation are found to be independent of the polymer thickness, indicating that the reaction occurs at the outer surface of the polymer film. At low ascorbate concentrations, below around 40 mM, the currents are found to be mass transport limited. At higher ascorbate concentrations the currents became kinetically limited. The experimental data for measurements at a range of potentials are fitted to a consistent kinetic model and the results summarized in a case diagram. The results obtained for the poly(aniline)-(polystyrene sulfonate) coated microelectrode are compared to those for a poly(aniline)-poly(vinyl sulfonate) coated microelectrode and to the results of an earlier study of the reaction at poly(aniline)-poly(vinyl sulfonate) coated rotating disc electrodes. For poly(aniline)-poly(styrene sulfonate) the oxidation of ascorbate is found to proceed by one electron reaction whereas for poly(aniline)-poly(vinyl sulfonate) the reaction is found to be a two electron oxidation.  相似文献   

6.
We investigated the response of symmetric poly(styrene-block-4vinylpyridine) P(S-b-4VP) diblock copolymer micelles to surface fields of variable strength at free surfaces and substrate interfaces when the micelles as spun were subjected to solvent annealing. Free surface interactions were controlled with solvent annealing in solvents of varied selectivity. On exposure to vapors of a solvent strongly selective for PS, the micelles retained their spherical shape but grew into cylindrical micelles or lamellar nanostructures via fusion on exposure to slightly selective or neutral solvent vapors. Giant 2D disks that completely wetted PS-grafted substrates resulted when spherical micelles were exposed to vapors of a highly selective solvent for P4VP. The interfacial interactions were controlled through subjecting them to UV/ozone (UVO) substrates initially coated with an end-grafted layer of short PS chains, with which the grafted PS chains became oxidized, degraded, or totally removed through UVO treatment for a controlled duration. When thin films were annealed in vapors of THF, the structural transition from spherical to cylindrical micelles depended on the interfacial field. On applying selective UVO exposure of optimal duration, we fabricated a substrate with two interfacial chemistries that promoted varied micellar species (spherical and cylindrical micelles) with a sharp boundary developed within thin films through solvent annealing for a controlled duration.  相似文献   

7.
The thickness of films of poly(methyl methacrylate) (PMMA), poly(vinyl acetate) (PVAc), and polystyrene (PS) adsorbed on Pyrex glass was studied by measuring the flow rates of polymer solutions and the corresponding pure solvents through sintered filter disks. Adsorption isotherms were in agreement with those reported by other workers and showed saturation adsorption equivalent to 2–8 condensed monolayers of monomer units. Film thicknesses were of the order of magnitude of the free coil diameters in solution and were directly proportional to the intrinsic viscosity of the polymer, except for PS in benzene where the thicknesses leveled off as molecular weight increased. It was concluded that polymers adsorb from solution in monolayers of compressed or interpenetrating coils; that below some critical molecular weight which varies with polymer and solvent, a much larger fraction of the segments lies directly in the interface; that adsorbed films may consist of a dense layer immediately adjacent to the surface and a deep layer of loops extending into the solvent; and that it is the segment—solvent interaction rather than the segment—surface interaction which dominates the conformation of the adsorbed chain.  相似文献   

8.
In this work we use the vapor-sorption equilibrium data to show the degree of solvent upturn in each solvent-polymer system. For this purpose, sixty-one isothermal data sets for forty copolymer + solvent binaries and for fourteen of their parent homopolymer + solvent binaries have been used in the temperature range of 23.5-80 °C. Solvents studied are acetone, acetonitrile, 1-butanol, 1,2-dichloroethane, chloroform, cyclohexane, hexane, methanol, octane, pentane, and toluene. Copolymers studied are poly(acrylonitrile-co-butadiene), poly(styrene-co-acrylonitrile), poly(styrene-co-butadiene), poly(vinyl acetate-co-ethylene), and poly(vinyl acetate-co-vinyl chloride). All copolymers are random copolymers. Some homopolymers are also studied: polyacrylonitrile, poly(cis-1,4-butadiene), poly(ethylene oxide), polystyrene and poly(vinyl acetate).According to these data sets, solvent weight fraction in the polymer is plotted against solvent vapor activity that is calculated assuming an ideal gas phase of pure solvent vapor neglecting the vapor pressure of the polymer. We use the Flory-Huggins theory to obtain dimensionless interaction parameter, χ. Also the Zimm-Lundberg clustering theory and non-ideality thermodynamic factor, Γ are used to interpret the equilibrium data.  相似文献   

9.
Resonant microcantilevers have demonstrated that they can play an important role in the detection of chemical and biological agents. Molecular interactions with target species on the mechanical microtransducers surface generally induce a change of the beam's bending stiffness, resulting in a shift of the resonance frequency. In most biochemical sensor applications, cantilevers must operate in liquid, even though damping deteriorates the vibrational performances of the transducers. Here we focus on diamond-based microcantilevers since their transducing properties surpass those of other materials. In fact, among a wide range of remarkable features, diamond possesses exceptional mechanical properties enabling the fabrication of cantilever beams with higher resonant frequencies and Q-factors than when made from other conventional materials. Therefore, they appear as one of the top-ranked materials for designing cantilevers operating in liquid media. In this study, we evaluate the resonator sensitivity performances of our diamond microcantilevers using grafted carboxylated alkyl chains as a tool to investigate the subtle changes of surface stiffness as induced by electrostatic interactions. Here, caproic acid was immobilized on the hydrogen-terminated surface of resonant polycrystalline diamond cantilevers using a novel one-step grafting technique that could be also adapted to several other functionalizations. By varying the pH of the solution one could tune the -COO(-)/-COOH ratio of carboxylic acid moieties immobilized on the surface, thus enabling fine variations of the surface stress. We were able to probe the cantilevers resonance frequency evolution and correlate it with the ratio of -COO(-)/-COOH terminations on the functionalized diamond surface and consequently the evolution of the electrostatic potential over the cantilever surface. The approach successfully enabled one to probe variations in cantilevers bending stiffness from several tens to hundreds of millinewtons/meter, thus opening the way for diamond microcantilevers to direct sensing applications in liquids. The evolution of the diamond surface chemistry was also investigated using X-ray photoelectron spectroscopy.  相似文献   

10.
In this work the intrinsic viscosity of poly(ethylene glycol)/poly(vinyl pyrrolidone) blends in aqueous solutions were measured at 283.1–313.1 K. The expansion factor of polymer chain was calculated by use of the intrinsic viscosities data. The thermodynamic parameters of polymer solution (the entropy of dilution parameter, the heat of dilution parameter, theta temperature, polymer–solvent interaction parameter and second osmotic virial coefficient) were evaluated by temperature dependence of polymer chain expansion factor. The obtained thermodynamic parameters indicate that quality of water was decreased for solutions of poly(ethylene oxide), poly(vinyl pyrrolidone) and poly(ethylene oxide)/poly(vinyl pyrrolidone) blends by increasing temperature. Compatibility of poly(ethylene oxide)/poly(vinyl pyrrolidone) blends were explained in terms of difference between experimental and ideal intrinsic viscosity and solvent–polymer interaction parameter. The results indicate that the poly(ethylene glycol)/poly(vinyl pyrrolidone) blends were incompatible.  相似文献   

11.
Microfabricated silicon cantilever sensor arrays represent a powerful platform for sensing applications in physics, chemistry, material science, biology and medicine. The sensor response is mechanical bending due to absorption of molecules. In gaseous environment, polymer-coated microcantilevers are used as electronic nose for characterization of vapors, resulting in cantilever bending due to polymer swelling upon exposure. Medical applications involve fast characterization of exhaled patient's breath samples for detection of diseases, based on the presence of certain chemicals in breath. We present a portable, compact, modular microcantilever setup, which uses a micropump for aspiration and a bluetooth interface for remote data acquisition.  相似文献   

12.
An off‐the‐shelf, moisture‐responsive, acetate‐backed adhesive tape is investigated as a commercially available smart material for fabricating low‐cost, multifunctional, humidity‐responsive millimeter‐scale structures. Laser ablation is used for cutting and thinning‐down the tape to enhance its response. Water‐submerged cantilevers show a radius of curvature of 3 mm or lower (for laser‐thinned cantilevers). Additionally, their humidity response is a function of the angle between the longitudinal axis of the cantilever and polymer orientation. A cut angled at 80° with respect to this orientation results in a tip rotation of up to 25°, enabling the formation of bending cantilevers with twisting behavior. The tape cantilevers are further functionalized with magnetic nanoparticles and used to create four‐finger grippers that close underwater within minutes and can sample 100 µL of liquid. A cyclic humidity monitor is also fabricated using a tape strip that walks unidirectionally on a ratchet‐shaped surface upon exposure to humidity variations. © 2013 Wiley Periodicals, Inc. J. Polym. Sci., Part B: Polym. Phys. 2013 , 51, 1263–1267  相似文献   

13.
Metal–polymer hybrid films are prepared by deposition of polymer‐coated PtCo nanoparticles onto block copolymer templates. For templating, a thin film of the lamella‐forming diblock copolymer poly(styrene‐b‐methyl methacrylate) P(S‐b‐MMA) is chemically etched and a topographical surface relief with 3 nm height difference is created. Two types of polymer‐grafted PtCo nanoparticles are compared to explore the impact of chemical selectivity versus the topographical effect of the nanotemplate. A preferable wetting of the polystyrene (PS) domains with poly(styrenesulfonate) (PSS)‐coated PtCo nanoparticles (instead of residing in the space between the domains) is observed. Our investigation reveals that the interaction between PSS‐coated nanoparticles and PS domains dominates over the topographical effects of the polymer surface. In contrast, a non‐selective deposition of poly(N‐vinyl‐2‐pyrrolidone) (PVP)‐coated PtCo nanoparticles and the formation of large metal‐particle aggregates on the film is observed.  相似文献   

14.
In this work we use the vapor-sorption equilibrium data to show the degree of solvent upturn in each solvent-polymer system. For this purpose, 23 isothermal data sets for four polymer + solvent binaries, one block copolymer + solvent binary and for the corresponding polymer pairs have been used in the temperature range of 25-70 °C. Solvents studied are benzene, carbon tetrachloride, chloroform and pentane. Homopolymers studied are polyisobutylene, poly(ε-caprolactone), poly(ethylene oxide), n-heptadecane, polystyrene, poly(vinyl chloride), poly(vinyl methyl ether), and n-tetracosane.According to these data sets, solvent weight fraction in the polymer is plotted against solvent-vapor activity that is calculated assuming an ideal gas phase of pure solvent vapor neglecting the vapor pressure of the polymer. We use the Flory-Huggins theory to obtain dimensionless interaction parameter, χ. Also the Zimm-Lundberg clustering theory and non-ideality thermodynamic factor, Γ are used to interpret the equilibrium data.  相似文献   

15.
The degradative effects of γ-radiation on diethyl ether solutions of poly(alkyl vinyl ethers) under a variety of conditions were studied by polymer molecular weight measurements. Poly(methyl vinyl ether) (PMVE), poly(ethyl vinyl ether) (PEVE), poly(isopropyl vinyl ether) (PIPVE), and poly(isobutyl vinyl ether) (PIBVE) exhibited similar degradative behavior, with G(SC) values between 0.3 and 0.9 scissions/100 eV at 0°C. Chemically polymerized and radiation-polymerized PEVE samples gave comparable results. Chain degradation was much more pronounced for samples of poly(tert-butyl vinyl ether) (PTBVE) which yielded a G(SC) value of 3.6 at 0°C. Degradation experiments conducted on PEVE in air resulted in significantly higher rates of scission: G(SC) = 5.6 scissions/100 eV at 0°C. Chain scission was not measurably influenced by changing the solvent from diethyl ether to di-isopropyl ether. Increased polymer concentration was found to reduce the rate of polymer degradation.  相似文献   

16.
Solubilities of several solvents were measured in four molten polymers by using an isobaric vapor-pressure apparatus. Solvent concentration ranged from 0.5 to 15 wt-%. The systems polyisoprene–benzene and polyisobutylene–benzene were studied at 80.0°C; polyisobutylene–cyclohexane was studied at 100.0°C; ethylene–vinyl acetate copolymer (EVA)–cyclohexane, EVA–isooctane, and poly(vinyl acetate)–isooctane were studied at 110.0°C. Of six polymer–solvent systems studied, all except poly(vinyl acetate)–isooctane appear to exhibit hysteresis in a single sorption–desorption cycle starting with dry polymer. The desorption curves of solvent activity plotted versus solvent weight fraction show an inflection point, suggesting localized adsorption of solvent molecules. Experimental data were analyzed with a theory which takes into account adsorption of solvent by polymer in addition to differences in free volumes and intermolecular forces. The theory gives a semiquantitative representation of the experimental data.  相似文献   

17.
In this work, correlations for the estimation of the infinite dilution activity coefficients of non-polar solvents in polystyrene (PS), poly(vinyl acetate) (PVAc), poly(n-butyl methacrylate) (PBMA), poly(dimethyl siloxane), poly(methyl methacrylate) (PMMA), poly(ethylene oxide) (PEO), poly(vinyl chloride) (PVC), polyisobutylene and polyethylene (PE), and that of polar solvents in PS, PVAc, PBMA, PMMA, PEO, PVC and PE are proposed. A total of 205 polymer/non-polar solvent systems with 1708 data points, and 118 polymer/polar solvent systems with 695 data points were used to develop the correlations. The overall average errors were 9.6% and 11.3%, respectively, significantly lower than other predictive models. Since the new correlations require only the connectivity indices of the solvents in the calculations, and the connectivity indices can be calculated easily once the molecular structure of the substance in question is known, they are easy to apply, and are useful for process design and development.  相似文献   

18.
The adsorption of spin-labelled poly(vinyl acetate) from dilute solutions in ethyl acetate, chloroform and toluene onto three silica adsorbents of different surface silanol contents was studied. The adsorption capacities of the three silica samples, which decreased with decreasing surface silanol content, were dependent on the nature of the solvent, being greatest in the poor solvent toluene and least in the good solvent ethyl acetate. The ESR spectra of the polymer adsorbed on the silica of highest silanol content suggested that the polymer had a relatively flat conformation when toluene or chloroform was solvent and a more looped conformation when ethyl acetate was solvent. With the silica of intermediate silanol content, the polymer adsorbed from chloroform solution also had a loopy conformation. The silica of lowest silanol content was prepared by treating the first silica absorbent with trimethylchlorosilane. The line-shapes in the ESR spectrum of the labelled polymer adsorbed on this modified silica indicated a change in mode of adsorption.  相似文献   

19.
The phenomenon of spontaneous changes in the linear dimensions (elongation-contraction) is described for commercial and laboratory samples of acetate yarns processed by wet spinning from high- molecular -mass cellulose diacetate in vapors of a mesophas ogenic solvent (which is able to form a lyotropic LC phase with the polymer), nitromethane, and its mixtures with water. The thermodeformational, elastic- plastic, physicomechanical, and surface characteristics of the yarns at different stages of their spontaneous deformation are analyzed. When samples are treated with probe vapors, orientational processes in the polymer matrix are activated, and this observation makes it possible to prepare yarns with improved physicomechanical characteristics and with low linear density. A new phenomenon (to our knowledge) of cyclic three- stage deformation of acetate monofilaments in nitromethane vapors is discovered. This evidence is interpreted from the standpoint of phase (amorphous glassy-liquid crystalline state) and conformational transitions as well as by the mechanism of interaction between polymers and solvent vapors and related development of the LC phase.  相似文献   

20.
The real time changes occurring within films of cylinder-forming poly(α-methylstyrene-block-4-hydroxystyrene) (PαMS-b-PHOST) were monitored as they were swollen in tetrahydrofuran (THF) and acetone solvent vapors. In situ information was obtained by combining grazing incidence small angle X-ray scattering (GISAXS) with film thickness monitoring of the solvent vapor swollen films. We show that for self assembly to occur, the polymer thin film must surpass a swollen thickness ratio of 212% of its original thickness when swollen in THF vapors and a ratio of 268% for acetone vapor annealing. As the polymer becomes plasticized by solvent vapor uptake, the polymer chains must become sufficiently mobile to self assemble, or reorganize, at room temperature. Using vapors of a solvent selective to one of the blocks, in our case PHOST-selective acetone, an order-order transition occured driven by the shift in volume fraction. The BCC spherical phase assumed in the highly swollen state can be quenched by rapid drying. Upon treatment with vapor of a non-selective solvent, THF, the film maintained the cylindrical morphology suggested by its dry-state volume fraction. In situ studies indicate that self-assembly occurs spontaneously upon attaining the threshold swelling ratios.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号