首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 351 毫秒
1.
Within the EU Standards, Measurement and Testing Program (SMT) two clenbuterol reference materials (RMs) were developed. Since clenbuterol readily accumulates and is slowly depleted from pigmented tissues such as the retina, homogenized eye liquid content is the most sensitive tissue for the detection of clenbuterol misuse. Therefore, both of the RMs were produced from bovine eye matrix: a negative control--RM 673 eye reference material, clenbuterol free (<0.50 microg/kg eye matrix) and a positive--RM 674 eye reference material containing clenbuterol (approximately 10 microg/kg eye matrix). Eyes were sampled from 103 German Simmental cattle and the inner liquid content was homogenized to a wet homogenized liquid content (HLC). This clenbuterol negative pool was divided into two sub-pools, one of which was spiked with clenbuterol to a final concentration of 10 microg clenbuterol/kg HLC. Of each pool exactly 2.0 +/- 0.01 g (+/- 0.5%) portions were weighed into 790 containers. Lyophilization of the 1,580 containers was performed in one batch. Parameters for the filling of containers, dry matter content, and residual moisture were in accordance with EU requirements. A three-year stability study and two homogeneity studies at various storage temperatures (-60 degrees C, -20 degrees C, +4 degrees C, +20 degrees C, and +37 degrees C) were performed. Low variation was observed within all of the homogeneity studies, proving that each of the RMs were homogeneous and that this was independent of storage temperature and storage time. In the stability studies, measured clenbuterol concentrations remained constant for RM 673 under the detection limit at 0.15 +/- 0.01 microg clenbuterol equivalent/kg HLC (n = 110) and were also constant for RM 674 at 11.21 +/- 0.15 microg clenbuterol/kg HLC (n=150; measured as duplicates). These studies demonstrate that clenbuterol-containing and clenbuterol-free RMs in bovine eye matrix can be successfully produced. Based on the results described above, it is concluded that both RMs may be suitable as candidates for certification.  相似文献   

2.
The certification by interlaboratory testing of a candidate reference material (ACSL CRM 3) for the concentration (mass fraction) of the pesticides chlorfluazuron (CFZ) and fluazuron (FZN) is described. The certification process was based on a two-stage nested design described in ISO Guide 35. Analysis of results reported by collaborating laboratories provided an assessment of the homogeneity of the RM. The certified values were chlorfluazuron -1.01 mg/kg and fluazuron -1.02 mg/kg. The upper and lower 95% confidence limits for CFZ and FZN were calculated to be: CFZ upper=1.05 mg/kg, lower=0.97 mg/kg; FZN upper=1.08 mg/kg, lower=0.95 mg/kg. A certificate was prepared according to guidelines set out in ISO Guide 31.  相似文献   

3.
Beef fat samples were prepared and tested as candidate reference materials for organochlorine and organophosphorus pesticides. The CRMs consisted of beef fat spiked with pesticide solutions. One sample (ACSL CRM 1) was prepared containing close to 0.2 mg/kg of each of the organochlorine pesticides dieldrin and heptachlor epoxide. A second sample (ACSL CRM 2) was prepared containing close to 0.8 mg/kg of each of the organophosphorus pesticides diazinon, chlorpyrifos and ethion. The spiking levels and homogeneity of the materials were verified. The coefficients of variation of 5 analyses carried out to test between-jar homogeneity for each reference material were dieldrin, 3.5%; heptachlor epoxide, 1.1%; diazinon, 2.1%; chlorpyrifos, 1.2% and ethion, 3.1%. No instability in any of these compounds was detected over a twelve month period. The candidate reference materials were found to be suitable for certification by interlaboratory testing. The certification process was based on a two-stage nested design described in ISO Guide 35. Analysis of results reported by collaborating laboratories provided an assessment of the homogeneity of the reference materials. The certified values together with their upper and lower 95% confidence limits are: ACSL CRM 1*Dieldrin*0.199 mg/kg **(0.188, **0.210 mg/kg) *Heptachlor epoxide*0.194 mg/kg **(0.176, **0.212 mg/kg) ACSL CRM 2*Diazinon*0.805 mg/kg **(0.755, **0.855 mg/kg) *Chlorpyrifos*0.790 mg/kg **(0.728, **0.852 mg/kg) *Ethion*0.813 mg/kg **(0.746, **0.879 mg/kg). A certificate for each material was prepared according to the guidelines set out in ISO Guide 31. Received: 25 April 1997 / Revised: 19 August 1997 / Accepted: 28 August 1997  相似文献   

4.
Beef fat samples were prepared and tested as candidate reference materials for organochlorine and organophosphorus pesticides. The CRMs consisted of beef fat spiked with pesticide solutions. One sample (ACSL CRM 1) was prepared containing close to 0.2 mg/kg of each of the organochlorine pesticides dieldrin and heptachlor epoxide. A second sample (ACSL CRM 2) was prepared containing close to 0.8 mg/kg of each of the organophosphorus pesticides diazinon, chlorpyrifos and ethion. The spiking levels and homogeneity of the materials were verified. The coefficients of variation of 5 analyses carried out to test between-jar homogeneity for each reference material were dieldrin, 3.5%; heptachlor epoxide, 1.1%; diazinon, 2.1%; chlorpyrifos, 1.2% and ethion, 3.1%. No instability in any of these compounds was detected over a twelve month period. The candidate reference materials were found to be suitable for certification by interlaboratory testing. The certification process was based on a two-stage nested design described in ISO Guide 35. Analysis of results reported by collaborating laboratories provided an assessment of the homogeneity of the reference materials. The certified values together with their upper and lower 95% confidence limits are: ACSL CRM 1*Dieldrin*0.199 mg/kg **(0.188, **0.210 mg/kg) *Heptachlor epoxide*0.194 mg/kg **(0.176, **0.212 mg/kg) ACSL CRM 2*Diazinon*0.805 mg/kg **(0.755, **0.855 mg/kg) *Chlorpyrifos*0.790 mg/kg **(0.728, **0.852 mg/kg) *Ethion*0.813 mg/kg **(0.746, **0.879 mg/kg). A certificate for each material was prepared according to the guidelines set out in ISO Guide 31.  相似文献   

5.
A project was undertaken to develop mussel reference materials that were certified for their mass fractions of saxitoxin and decarbamoyl-saxitoxin. Fifteen laboratories from various European countries participated. Three of these had major responsibility for substantial parts of the work and overall coordination of the project. The project involved 4 main activities: (1) procurement and characterization of calibrants; (2) improvement of analytical methodology; (3) preparation of reference materials, including homogeneity and stability studies; (4) 2 interlaboratory studies and a certification exercise. The joint activities resulted in 3 homogeneous and stable reference materials: 2 lyophilized mussel materials with and without naturally incurred paralytic shellfish poisoning (PSP) toxins, and a saxitoxin enrichment solution. The reference materials were certified with respect to their saxitoxin and decarbamoyl-saxitoxin content. The lyophilized mussel material with PSP toxins (CRM 542) contained <0.07 mg saxitoxin x 2HCl/kg and 1.59 +/- 0.20 mg decarbamoyl-saxitoxin x 2HCl/kg. The lyophilized mussel material without PSP toxins (CRM 543) contained <0.07 mg saxitoxin x 2HCl/kg and <0.04 mg decarbamoyl-saxitoxin x 2HCl/kg. The certified value of the saxitoxin mass fraction in the saxitoxin enrichment solution (CRM 663) was 9.8 +/- 1.2 microg/g.  相似文献   

6.
Analyses of nutritive elements are routinely performed in grass or hay for animal feed in order to improve the state of health and growth of domestic animals. To control the quality of such determinations, the Community Bureau of Reference (BCR) so far has produced two certified reference materials: Hay Powder (CRM 129) and Rye Grass (CRM 281). After a careful preparation procedure of the materials, a homogeneity study and a long-term stability study, the contents of the elements Ca, K, Mg, P, S, Zn, I, N and Kjeldahl-N were certified in CRM 129, whereas CRM 281 was certified for As, B, Cd, Cu, Hg, Mn, Mo, Ni, Pb, Sb, Se and Zn. This paper presents the certification exercise and especially concentrates on the elements I, B and Mo as examples of analytical work. Indicative values for Co, Cr, Fe, Cl and Na were also obtained.  相似文献   

7.
Analyses of rainwater are routinely performed by a number of organisations to monitor the contribution from rainwater to the component occurrences in the environment and the acidification of the environment. To control the quality of such determinations, the Community Bureau of Reference (BCR) has organised a certification campaign to produce two simulated rainwater reference materials (CRM 408, low mineral content and CRM 409, high mineral content). The materials were carefully prepared (addition of pro analysis and supra pure reagents with the mentioned elements to silica-free deionised water) and its homogeneity and long-term stability were verified. The materials were certified for their contents of ammonium (106 mol/kg) (CRM 409), calcium (7.68 and 15.5 mol/kg), chloride (67.3 and 113 mol/kg), hydronium (16.6 and 48.0 mol/kg), magnesium (6.14 and 12.3 mol/kg), nitrate (20.1 and 78.1 mol/kg), potassium (4.25 mol/kg) (CRM 409), sodium (42.0 and 82.9 mol/kg) and sulphate (10.5 and 53.2 mol/kg). Indicative values (not certified) are given for ammonium and potassium in CRM 408. This paper presents the certification work performed, as well as the analytical work for the certification of the contents of relevant species.  相似文献   

8.
A candidate environmental certified reference material (CRM) for the determination of multielements in tea leaves and materials of similar matrix, NIES CRM No. 23 Tea Leaves II, has been developed and characterized by the National Institute for Environmental Studies (NIES), Japan. The origin of the material was tea leaves, which were ground, sieved through a 106-μm mesh, homogenized, and then subdivided into amber glass bottles. The results of homogeneity and stability tests indicated that the material was sufficiently homogeneous and stable for use as a reference material. The property values of the material were statistically determined based on chemical analyses by a network of laboratories using a wide range of methods. Sixteen laboratories participated in the characterization, and nine certified values and five reference values were obtained. These property values of the candidate CRM, which are expressed as mass fractions, were close to the median and/or mean values of the mass fractions of elements in various tea products. The candidate CRM is appropriate for use in analytical quality control and in the evaluation of methods used in the analysis of tea and materials of similar matrix.  相似文献   

9.
The methylmercury content in two new marine bivalve mollusk tissue Standard Reference Materials (SRMs) has been certified using results of analyses from the National Institute of Standards and Technology (NIST) and two other laboratories. The certified concentrations of methylmercury were established based on the results from four and six different (independent) analytical methods, respectively, for SRM 1566b Oyster Tissue (13.2 +/- 0.7 microg/kg) and SRM 2977 Mussel Tissue (organic contaminants and trace elements) (36.2 +/- 1.7 microg/kg). The certified concentration of methylmercury in SRM 1566b is among the lowest in any certified reference material (CRM).  相似文献   

10.
The development and certification of a coal fly ash certified reference material (CRM) for polycyclic aromatic hydrocarbons (PAH) is described; this is the first natural matrix CRM for organic environmental analysis in China. The homogeneity and stability of this material have been tested by HPLC. The concentrations of several PAH were determined by use of two independent, different methods--solvent extraction-HPLC analysis with UV detection coupled with fluorescence detection (FLD) and solvent extraction, isolation with a silica column, and GC analysis with flame ionization detection (FID). Five certified values were determined: phenanthrene 7.1 +/- 2.6 microg g(-1), anthracene 2.0 +/- 0.8 microg g(-1), fluoranthene 7.4 +/- 1.9 microg g(-1), pyrene 7 +/- 2 microg g(-1), and benzo[a]pyrene 1.3 +/- 0.3 microg g(-1). Reference values for several other PAH are also suggested.  相似文献   

11.
The use of reference materials (RMs) is a key activity for the improvement and maintenance of a worldwide coherent measurement system. As detailed in ISO Guide 33, RMs with different characteristics are used in measurement processes, for the purpose of precision control, bias assessment, calibration, assigning values to other materials, and maintaining conventional scales, to name a few. For the establishment of metrological traceability of measurement results to international scales or other measurement standards, proper use of certified reference materials (CRMs) is essential. From the perspective of a reference material producer, the documentation that is provided with an RM is the value-adding component of the material; for the user, the document is critical for the correct implementation and use of the RM in the measurement process. The ISO Committee on Reference Materials (ISO/REMCO) recognised the importance of the documentation that accompanies a reference material as early as 1981 when the first edition of ISO Guide 31 was published. The third edition of the Guide that was published recently considers the appropriate accompanying documentation for all types of reference materials, i.e. CRMs and non-certified RMs.  相似文献   

12.
13.
14.
Summary Analyses of plankton are performed by a number of organisations to investigate the transfer and uptake of toxic elements along the trophic chain and to monitor the levels of contamination of different aquatic environments. In order to obtain reliable transfer functions in environmental models or to use plankton as an indicator organism for the assessment of environmental pollution, these analyses should give accurate results. As accuracy requires quality control and the application of certified reference materials (CRMs), a certification campaign has been conducted by the Community Bureau of Reference (BCR). A plankton material was collected in a freshwater pond, lyophilised, homogenised and bottled and its homogeneity and long-term stability were verified. The material (CRM 414) was analysed by a group of 15 selected laboratories having given proof of their adequate QC and using different analytical methods. The contents of As, Cd, Cr, Cu, Hg, Mn, Ni, Pb, Se, V and Zn are certified. This paper presents the certification work performed.  相似文献   

15.
 Cabbage is frequently used in environmental monitoring and food control, and, hence, cabbage reference materials (RMs) are required for ensuring quality assurance. A cabbage RM was prepared in view of certification of specific elements from the "black list" of high toxicological interest and nutritive importance. All tasks of the RM production (production of the plant material, cutting and freeze-drying, determination of the residual water content, preparation of the RM, homogeneity testing, stability testing, certification measurements) are described in detail. Received: 12 November 1999 / Accepted: 29 January 2000  相似文献   

16.
A certified reference material (CRM) for the determination of perfluorooctane sulfonate (PFOS) in acrylonitrile-butadiene-styrene (ABS) resin (NMIJ CRM 8155-a) has been issued by the National Metrology Institute of Japan (NMIJ). The bulk material was prepared by mixing commercial ABS resin powder and potassium PFOS and cut into square plates (20 × 20 mm, 2 mm thick) as the CRM. Analytical processes combined with isotope-dilution mass spectrometry and liquid chromatography/mass spectrometry were optimised and applied for characterisation. One of the approaches adopted by NMIJ for certification is that results from two or more primary methods of measurement should be used; thus, two optimised isotope-dilution mass spectrometric methods (Methods 1 and 2 with reprecipitation and with reprecipitation/solid phase extraction, respectively, were validated mutually and employed) were used to determine the certified value. Homogeneity and stability of the square plates were evaluated and their uncertainty contributions (as relative standard uncertainties) were 1.43% for inhomogeneity and 6.96% for approximately two years’ instability. The certified mass fraction of linear PFOS (heptadecafluoro-1-octanesulfonic acid) in the CRM with expanded uncertainty (coverage factor k = 2, approximately 95% confidence interval) was (33.1 ± 5.0) mg kg?1 as free acid of PFOS.  相似文献   

17.
Both (206)Pb-labeled trimethyllead (TML) and triethyllead (TEL) were synthesized from (206)Pb-enriched metallic Pb certified reference material (NIST SRM 983) and iodomethane or iodoethane through a one-process reaction in a closed system using centrifuge tubes, respectively. Organolead compounds in an urban dust reference material (BCR CRM 605) were extracted with an acetic acid/methanol (1:1) solution, which was mechanically shaken for 24 h. After adjusting the pH of the extracted solution to pH 5, the extracted organolead compounds were derivatized by tetrabutylammonium tetrabutylborate (TATB) and measured with GC-ICPMS. The analytical results of TML and TEL for BCR CRM 605 were 8.22 +/- 0.04 microg kg(-1) (mean +/- standard deviation, n = 3) and 1.12 +/- 0.06 microg kg(-1), respectively. The analytical results of TML agreed well with the certified value (7.9 +/- 1.2 microg kg(-1)).  相似文献   

18.
 The principles of the ISO "Guide to the expression of uncertainty in measurement" are applied to the analysis of solid materials by graphite furnace atomic absorption spectrometry. Assessment of trueness is achieved by the analysis of a certified reference material (CRM) under fixed instrumental conditions. For the evaluation of the method's uncertainty (as part of the validation) a model equation is derived, considering all significant contributions, including the uncertainty in the CRM value and the uncertainty in the CRM analysis. A concrete example is presented and discussed (soya flour as an unknown sample and CRM BCR rye grass). For routine analysis a pooled estimate from the validation experiment can be used, leading to an acceptable small uncertainty range even in the case of "duplicate determination". The test for trueness (acceptance) of the result of the CRM analysis is applied and the correction for detected bias is discussed. Received: 28 June 1998 · Accepted: 13 July 1998  相似文献   

19.
A Certified Reference Material (CRM) for determination of aromatic hydrocarbons in air was developed. The CRM 562 consists of aromatic hydrocarbons sorbed on charcoal in glass tubes. Initial feasibility studies established that a homogeneous and stable batch could be prepared. Three intercomparisons prior to the certification allowed the identification of various sources of error. Then, a batch of about 3000 tubes was charged and certified on the basis of analyses carried out in 15 European laboratories. The preparation of the reference material and the results of the certification exercise is described. An overview on the analytical techniques used and the quality control guidelines are also presented. The certified values are 15.0 ± 0.4 μg benzene, 147.3 ± 3.8 μg toluene, 96.4 ± 2.5 μg m-xylene and 93.0 ± 2.9 μg o-xylene per tube. This reference material is recommended for quality control of measurements in the field of occupational hygiene.  相似文献   

20.
Arsenate [As(V)] solution reference material, National Metrology Institute of Japan (NMIJ) certified reference material (CRM) 7912-a, for speciation of arsenic species was developed and certified by NMIJ, the National Institute of Advanced Industrial Science and Technology. High-purity As2O3 reagent powder was dissolved in 0.8 M HNO3 solution and As(III) was oxidized to As(V) with HNO3 to prepare 100 mg kg-1 of As(V) candidate CRM solution. The solution was bottled in 400 bottles (50 mL each). The concentration of As(V) was determined by four independent analytical techniques—inductively coupled plasma mass spectrometry, inductively coupled plasma optical emission spectrometry, graphite furnace atomic absorption spectrometry, and liquid chromatography inductively coupled plasma mass spectrometry—according to As(V) calibration solutions, which were prepared from the arsenic standard of the Japan Calibration Service system and whose species was guaranteed to be As(V) by NMIJ. The uncertainties of all the measurements and preparation procedures were evaluated. The certified value of As(V) in the CRM is (99.53 ± 1.67) mg kg-1 (k = 2).  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号