首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
In this article, the effects of the stationary phase, buffer pH, organic modifier type, organic modifier composition, applied voltage, and temperature on the migration of several synthetic peptides in etched chemically modified open-tubular capillaries are discussed. With these solutes, migration is due to two effects: electrophoretic mobility and solute/bonded phase interactions. In addition, relative migration rates are evaluated for the peptide samples as a function of these experimental variables in order to determine which parameters might be useful for optimizing separations in open-tubular capillary electrochromatography (OTCEC). Some examples of synthetic peptide separations are presented where the sample contains a major component and several minor species, demonstrating how the resolution of these mixtures can be affected by the appropriate choice of experimental variables.  相似文献   

2.
Fused silica capillaries for use in electrophoretic analyses are etched with ammonium bifluoride in the presence of a second inorganic salt (CuCl(2), CrCl(3), NaNO(3), or (NH(4))(2)CO(3)). The effects of the presence of these inorganic components in the surface matrix on the electromigration behavior of enkephalins are evaluated. Resolution, efficiency and peak shape are used to compare the various columns. In some cases the etched surface is then modified by the addition of an octadecyl moiety using a silanization/hydrosilation procedure. The surface properties of the etched capillaries can also be evaluated by electroosmotic flow measurements. RSDs of migration times under identical experimental conditions were <1%.  相似文献   

3.
Fused silica capillaries with an I.D. of 20 microns are etched and then chemically modified by the silanization/hydrosilation method to attach an octadecyl moiety for use in electrokinetic chromatography. The etched capillaries after chemical modification are shown to have an anodic electroosmotic flow below pH 4.5. In comparison to bare 20 microns capillaries and unetched but chemically modified 20 microns capillaries, the etched C18 fused silica tubes show better separation of mixtures of lysozymes and cytochrome c's under identical conditions of buffer, pH and applied voltage. It was also demonstrated that this open tubular approach to capillary electrochromatography was amenable to a number of different types of basic compounds ranging in size from typical small amines to biomolecules. As expected, pH is an important variable that must be controlled in order to obtain an optimized separation. Reproducibility studies verify the stability of the silicon-carbon linkage produced in this modification method so that column lifetimes of at least 300 injections can be expected.  相似文献   

4.
The use of etched, chemically modified, capillaries with a rectangular inner channel for open tubular electrochromatography is investigated. Comparisons of separation capabilities are made between circular and rectangular capillaries undergoing the same etching and chemical modification processes. With the long dimension of the rectangular column aligned in the direction of the optical light path, the relative sensitivities of the two capillary geometries are evaluated. The electrochromatographic properties of two catechins found in tea are investigated on the rectangular etched octadecyl-modified capillary.  相似文献   

5.
Zeng Z  Xie C  Li H  Han H  Chen Y 《Electrophoresis》2002,23(9):1272-1278
Two host molecules, p-tert-butylcalix[6]-1,4-crown-4 and p-tert-butylcalix[6]arene were prepared and attached onto the inner surfaces of capillaries for open-tubular electrochromatography with the aid of gamma-glycidoxypropyl-trimethoxysilane (KH-560) as bridging agent. The successful bonding was confirmed by infrared (IR) results and greatly decreased electroosmotic flow (EOF). Parameters affecting separation, such as buffer pH and organic modifier were studied. The two novel stationary phases were evaluated by the separation of isomeric toluidines, a mixture of pyridine and isomeric picolines, and isomeric dihydroxybenzenes; comparisons between capillaries coated with the two stationary phases and bare capillary were investigated. The special selectivity of these two novel stationary phases showed a certain extent of supramolecular interactions between stationary phases and solutes.  相似文献   

6.
A stable polyelectrolyte multilayer (PEM) coating was investigated for use in open-tubular capillary electrochromatography (o-CEC). In this approach, the PEM consisted of the cationic polymer of a quaternary ammonium salt, poly(diallyldimethylammonium chloride) and the anionic polymeric surfactant, poly(sodium undecylenic sulfate). Both the cationic and anionic polymers were physically adsorbed to the surface of a fused-silica capillary by use of a simple coating procedure. This procedure involved an alternate rinse of the positively and negatively charged polymers. The performance of the PEM coating as a dynamic stationary phase was evaluated by use of electrochromatographic experiments and showed good selectivity for both phenols and benzodiazepines. Reproducibility of the PEM coating was also evaluated by calculating the relative standard deviations (RSDs) of the electroosomotic flow (EOF). The run-to-run and capillary-to-capillary RSD values of the EOF were less than 1.5%. The endurance of the coating was more than 100 runs. The importance of the PEM coating was illustrated by comparing separations on a bare uncoated capillary with the coated capillary. In addition, the chromatographic performance using o-CEC and micellar electrokinetic chromatography (MEKC) was compared for the separation of benzodiazepines.  相似文献   

7.
Etched chemically modified capillaries with two different bonded groups (pentyl and octadecyl) are compared for their migration behavior of several common proteins and metalloproteins as well as metalloproteinases. Migration times, efficiency and peak shape are evaluated over the pH range of 2.1-8.1 to determine any effects of the bonded group on the electrochromatographic behavior of these compounds. One goal was to determine if the relative hydrophobicity of the stationary phase has a significant effect on proteins in the open tubular format of capillary electrochromatography as it does in HPLC. Reproducibility of the migration times is also investigated.  相似文献   

8.
Qu Q  Zhang X  Shen M  Liu Y  Hu X  Yang G  Wang C  Zhang Y  Yan C 《Electrophoresis》2008,29(4):901-909
Octadecylamine-capped gold nanoparticles (ODA-Au-NPs) were prepared and characterized by using UV-Vis adsorption spectrum, transmission electron chromatography (TEM), SEM, and FT-IR. A simple but robust hydrophobic coating was easily developed by flushing a capillary with a solution of ODA-Au-NPs, because the positive charges were carried by the nanoparticles which strongly adsorb to the negatively charged inner surface of a fused-silica capillary via electrostatic and hydrophobic interactions. The chromatographic characteristics of the coated capillary was investigated by varying the experimental parameters such as buffer pH, buffer concentration, and percentage of organic modifier in the mobile phase. The results show that (i) resolution between thiourea and naphthalene is almost the same when comparing the electrochromatograms obtained using pH 7 buffer as mobile phase after and before the capillary column was operated using pH 11 and 3 mobile phase; (ii) no significant changes in retention time and deterioration in peak efficiency were found after 60 runs of test aromatic mixtures; and (iii) column efficiency up to 189 000 theoretical plates/meter for testosterone was obtained. All of the results indicated that the coating could act as a stable stationary phase for open tubular CEC as well as for bioanalysis.  相似文献   

9.
Sapphyrin coating of the inner wall of the capillary results in a distinct interaction of the phosphate residue-possessing compounds as proven by a seven-membered model mixture of nucleoside mono- and diphosphates and ATP. Modification of the inner surface of the capillary not only alters the endoosmotic flow (as would have been expected) but brings about an electrochromatographic effect based on the interaction of tested phosphate moiety-bearing solutes with the immobilized sapphyrin layer. Elution of the sample can be achieved by using either 25 mM borate-acetate buffer in which monophosphates are not only separated from each other, but also selectively separated from di- and triphosphates (ATP). With the other two buffer systems tested, i.e. borate-phosphate and Tris-HCl, better selectivity (though smaller interaction with the capillary coating) was observed. The coating is relatively stable (can be used for 20 subsequent runs at least), simple to materialize, and in spite of a strong UV absorbancy of sapphyrin at the wavelength used (254 nm), decreases the limit of detection by no more than one order of magnitude as compared to the untreated capillary. Resolution factors (calculated to the preceding peak) are in most cases better in the electrochromatographic separation mode as compared to the separation in the untreated capillary, which reflects both the decrease in the electroosmotic flow and the interaction with the capillary wall coating.  相似文献   

10.
We describe the use of the polymeric surfactant poly(sodium undecylenic sulfate) (poly-SUS) as a stationary phase coating in open-tubular capillary electrochromatography (OT-CEC) coupled with electrospray ionization-mass spectrometry (ESI-MS) for the analysis of beta-blocker and benzodiazepine analytes. The production of a polymeric surfactant coating on the capillary inner wall involves (i) adsorption of the cationic polymer poly(diallyldimethylammonium chloride) (PDADMAC) to the inner surface of capillary, and (ii) adsorption of the negatively charged poly-SUS onto the cationic polymer layer via strong physical interaction of the two polymer layers. As compared with micellar electrokinetic chromatography (MEKC) coupled with ESI-MS, the main advantage of this proposed method is minimization of introduction of the monomeric or polymeric surfactant into the mass spectrometer, thus avoiding the interference of the nonvolatile micelle in ESI-MS. The effects of buffer pH and applied voltage on the separation of the analytes are also discussed. Under optimum conditions, four of the five beta-blockers and four benzodiazepines are separated.  相似文献   

11.
This paper reports on a new strategy to coat fused silica capillaries through ionic adsorption of gold nanoparticles (AuNPs) on a polyelectrolyte multilayer (PEM) modified capillary wall. The coating was constructed in situ by alternating rinses with positively charged poly(diallydimethylammonium chloride), negatively charged poly(sodium-4-styrenesulfonate), and positively charged AuNPs. After self-assembly of n-octadecanethiol onto the surface of AuNPs, the modified capillary was investigated as a new medium for the separation of neutral analytes and proteins in open-tubular capillary electrochromatography (OT-CEC). The surface coverage of the capillary wall was increased using the high density of AuNPs which were dynamically capped with 4-dimethylaminopyridine (DMAP). The chromatographic performance of the column coated with positively charged AuNPs was remarkably improved compared with a column modified with negatively charged AuNPs. The coating was robust over more than 810 runs in this study and also showed high stability against 0.01 M NaOH, 0.01 M HCl, and electrolyte concentrations up to 70 mM. The run-to-run, day-to-day, and capillary-to-capillary reproducibilities of electroosmotic flow were satisfying with relative standard deviation values of less than 1% in all cases. The AuNP-coated PEM modified capillary column not only showed good performance for neutral analytes but also was suitable for the analysis of both basic and acidic proteins.  相似文献   

12.
M A Rehder  L B McGown 《Electrophoresis》2001,22(17):3759-3764
DNA aptamers that form a G-quartet conformation were covalently attached to a capillary surface for open-tubular capillary electrochromatographic separation of bovine beta-lactoglobulin variants A and B, which vary by 2 of their 162 amino acid residues. Separation was achieved using a 4-plane, G-quartet aptamer stationary phase with tris(hydroxymethyl)aminomethane (Tris) or phosphate buffer as the mobile phase. In control experiments, separation did not occur using either an oligonucleotide of similar base composition but which does not form a G-quartet structure, or using capillary zone electrophoresis on a bare capillary under similar experimental conditions. Separation was achieved using a capillary coated only with the covalent linker molecule. In phosphate buffer, the separations were similar for aptamer-coated and linker-only stationary phases, while in Tris buffer, retention times were almost doubled for the linker-only capillary. When Tris buffer is the mobile phase, there appears to be weaker interactions between the proteins and the stationary phase that may result in a gentler, less denaturing separation than is commonly achieved using hydrocarbon-based stationary phases.  相似文献   

13.
By an on-column sol-gel process, a chiral monolithic stationary phase was prepared by the fusion of permethyl-beta-cyclodextrin-silica (Chira-Dex-silica) particles and by linking them to the internal capillary wall. The resulting monolith is stable toward voltage (30 kV) and pressure (300 bar) and possesses a high efficiency (up to 100,000 theoretical plates per meter). Efficient enantiomeric separation of various chiral compounds by pressure-supported capillary electrochromatography (CEC) was achieved. When comparing this method to capillary liquid chromatography (LC) employing the same column in an unified equipment, CEC shows a twofold higher column efficiency at comparable elution times and hence better resolution factors.  相似文献   

14.
We have used alkanethiol self-assembly and dithiol layer-by-layer (LBL) self-assembly processes to prepare an Au nanoparticle (NP)-coated open tubular capillary electrochromatography (OTCEC) column for the separation of three neutral steroid drugs (testosterone, progesterone, and testosterone propionate). The CEC column was fabricated through LBL self-assembly of Au NPs on a 3-aminopropyltrimethoxysilane (APTMS)-modified fused-silica capillary and subsequent surface functionalization of the Au NPs through self-assembly of alkanethiols. We investigated the electrochromatographic properties of the resulting Au NP-coated CEC column using a "reversed phase" test mixture of three steroid drugs. We found that the key factors affecting the separation performance were the number of Au NP layers, the length of the carbon-atom chain of the alkanethiol self-assembled on the Au NPs, the percentage of organic modifier, and the pH of the running electrolyte. This study reveals that the self-assembly of alkanethiols and dithiols onto Au NPs provides stationary phases for CEC separation that are easy to prepare and whose retention behavior is highly controllable and reproducible. We believe that our findings will contribute to further studies of the application of nanotechnology to separation science.  相似文献   

15.
16.
Effective heat dissipation is critical for reproducible and efficient separations in electrically driven separation systems. Flow rate, retention kinetics, and analyte diffusion rates are some of the characteristics that are affected by variation in the temperature of the mobile phase inside the column. In this study, we examine the issue of Joule heating in packed capillary columns used in capillary electrochromatography (CEC). As almost all commonly used CEC packings are poor thermal conductors, it is assumed that the packing particles do not conduct heat and heat transfer is solely through the mobile phase flowing through the system. The electrical conductivity of various mobile phases was measured at different temperatures by a conductivity meter and the temperature coefficient for each mobile phase was calculated. This was followed by measurement of the electrical current at several applied voltages to calculate the conductivity of the solution within the column as a function of the applied voltage. An overall increase in the conductivity is attributed to Joule heating within the column, while a constant conductivity means good heat dissipation. A plot of conductivity versus applied voltage was used as the indicator of poor heat dissipation. Using theories that have been proposed earlier for modeling of Joule heating effects in capillary electrophoresis (CE), we estimated the temperature within CEC columns. Under mobile and stationary phase conditions typically used in CEC, heat dissipation was found to be not always efficient. Elevated temperatures within the columns in excess of 23 degrees C above ambient temperature were calculated for packed columns, and about 35 degrees C for an open column, under a given set of conditions. The results agree with recently published experimental findings with nuclear magnetic resonance (NMR) thermometry, and Raman spectroscopic measurements.  相似文献   

17.
Capillaries for use in electrophoretic analyses are etched with ammonium bifluoride and in some cases a second inorganic salt is included in the process. The effects of the presence of these inorganic components in the surface matrix on the electromigration of heterocyclic aromatic amines and enkephalins are evaluated. Resolution, efficiency, and peak shape are used to compare the various columns. In one instance, the etched surface is then modified by the addition of an octadecyl moiety using a silanization/hydrosilation procedure. The surface properties of the various etched capillaries are also compared by electroosmotic flow measurements.  相似文献   

18.
In this investigation, various capillary electrochromatographic (CEC) experiments have been employed to characterize the properties of etched, chemically-modified surfaces of open tubular capillary columns with peptides as solute probes and under conditions of variable voltage, temperature and solvent composition. The separation performance of etched capillaries with either n-octadecyl or liquid crystal moieties derived from a cholesterol phase bonded to the surface were compared. With the liquid crystal bonded species, interesting and significantly different variations in retention behavior of peptides are obtained compared to those observed with the corresponding n-octadecyl modified surfaces by changes in temperature, solvent composition and field strength. These peptide separations illustrate the usefulness of this CEC approach for practical applications, where both the retention characteristics of the charged analytes as well as the selectivity differences due to the surface properties of the etched chemically-modified surfaces of open tubular capillary columns can be rationally modulated. As in HPLC, appropriate choice of CEC experimental variables, including the chemical properties of the immobilized ligand(s), represents a powerful tool for optimizing resolution.  相似文献   

19.
Monolithic stationary phases based on poly(ethylene glycol) diacrylates for capillary electrochromatography were developed. Several poly(ethylene glycol) diacrylates (Mn 250, 575, and 700) were used as single monomers and the resulting columns were carefully compared. Methanol and ethyl ether were selected as porogenic solvents, and in all cases ultraviolet radiation was selected as initiation method to prepare polymeric monoliths. The influence of the monomer chain length and ratio monomer/porogen on the morphological and electrochromatographic properties of the resulting monoliths was investigated. Several families of compounds with different polarity (alkyl benzenes, organophosphorous pesticides, benzoic acid derivatives, and sulfonamides) were selected to evaluate the performance of the fabricated monolithic columns. The best results were obtained for poly(ethylene glycol) diacrylate 700 monoliths affording efficiencies of 144 000 plates/m for retained polar aromatic small molecules and excellent reproducibility in column preparation (RSD values below 2.5%).  相似文献   

20.
In this paper, an open tubular affinity capillary electrochromatography (OT‐ACEC) was developed by physical adsorption of rabbit platelets on the inner surface of capillary. The interactions between small molecules include adenosine diphosphate (ADP) (positive control), protocatechuic acid (negative control) and seven natural products (salvianolic acid B, salvianic acid A sodium, hydroxysafflor yellow A, ferulic acid, chlorogenic acid, sinapic acid, caffeic acid) and platelets were evaluated by their retention factors and binding constants obtained based on peak‐shift assay. Then, the activities of anti‐platelet aggregation induced by thrombin (THR), ADP and arachidonic acid (AA) for those small molecules (except ADP) were evaluated by turbidimetric method. The results indicate that: (i) ADP, a platelet aggregation inducer, had strong interaction with platelet, while protocatechuic acid that had no inhibition on platelet aggregation behaved no specific interaction; (ii) there was a positive correlation between the anti‐platelet aggregation activities of small molecules and their interactions with platelet, generally those compounds with higher binding constants with platelet exhibited higher activities. Therefore, the OT‐ACEC method developed in the present study can be a potential method to evaluate affinity interactions between small molecules and platelets, so as to predict the biological activities such as anti‐platelet aggregation for the small molecules.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏