首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 546 毫秒
1.
使用普通电感耦合等离子体质谱法(ICP MS)测定一些标准参考物质中多种元素的浓度,该方法不仅可测定常规的有毒元素如As,Pb ,Hg,Cd ,还可以测定常量元素包括P ,Ca,Fe ,K ,Na等。实验研究了消解样品的方法、回收率和方法的检测限等,证明ICP MS的EPA2 0 0 8标准干扰校正方法用于测定食品和植物样品中多元素浓度是可行的。应用ICP MS的八极杆碰撞反应池(ORS)技术测定As ,Se等元素,比较了配置ORS系统与不配置ORS系统的ICP MS仪器对这两种元素测定的结果,讨论了ArCl和ArAr干扰的消除,发现ORS系统可以有效地消除样品基体产生的ArCl,ArAr等分子离子对样品中超痕量的As,Se的干扰。  相似文献   

2.
ICP-AES法测定人血清中的硒   总被引:6,自引:0,他引:6  
采用消化法预处理血清样品 ,并用ICP AES法测定样品中的Se ,同时 ,探索Fe的存在对测定的干扰情况以及干扰的消除方法。结果表明 ,Se的检测限为 0 0 0 76μg·mL- 1 ,加标回收率为 91 6 % ,1 0次测定的RSD(n =1 0 )为 2 1 4 7% ;在样品中加入KOH ,可以大大降低Fe对Se测定的干扰。  相似文献   

3.
对于食品中多无机元素的检测控制急需一种样品前处理简单快速、检出范围广的分析方法,因此通过考察不同分散剂、颗粒粒径大小、悬浊液中样品质量浓度以及内标元素对全反射X射线荧光光谱法测试结果的影响,建立了快速、便捷的悬浮液进样-全反射X射线荧光光谱法测定食品中多无机元素的方法。实验结果表明:去离子水(Milli-Q water),聚乙二醇辛基苯基醚(Triton X-100)和硝酸三种不同分散剂中,光学显微镜下形貌上Milli-Q water和Triton X-100作分散剂较HNO_3样品分散更均匀, Milli-Q water作分散剂其测量结果较Triton X-100更准确;试样经研磨,并用激光衍射粒度分析仪测定试样研磨前后的颗粒粒径大小,发现平均颗粒粒径小的样品全反射X射线荧光光谱法测试结果准确度更高;称取不同量样品于相同量分散剂中,看出随着悬浮液中样品质量浓度增加,回收率会增大或降低;实验中分别应用Ga或Se为内标元素定量分析GBW08571贻贝样品,但是由于所测元素As和Se是相邻元素,引起谱线重叠,进而Se为内标元素会影响As元素定量分析的准确度,因此为避免内标元素对测量元素产生谱线干扰,实验中选择Ga为内标元素。用该方法测定了四个有证标准物质(食品类),四个标准物质中无机元素的测量值和标准值比较,大多元素(除Ca元素)回收率集中在80%~120%间, RSD小于15%,且对于不同含量范围的元素,用该方法测定均能获得可靠的测试结果,相对于需消解的电感耦合等离子体原子发射光谱法和质谱法的方法,用悬浮液制样-全反射X射线荧光分析测定食品中的多元素更快速、便捷。  相似文献   

4.
目前硒(Se)的测定主要采用氢化物-原子荧光光谱法(HG-AFS)。实验发现采用氢气发生器为HG-AFS提供氢气(H_2),可以提高间断氢化物发生-原子荧光光谱法测定Se的灵敏度。当H_2流量达到80 mL·min~(-1)及以上时,氢气发生器提供的H_2可以先行点燃氢火焰,有效避免了点火提前或迟滞对测定的影响,提高了测定的精密度。地球化学调查通常需要测定几十种元素,需要分别进行多次消解。其中Se采用硝酸(HNO_3)-高氯酸(HClO_4)进行消解,消解后的样品采用浓盐酸(HCl)将Se(Ⅵ)还原为Se(Ⅳ)。而DZ/T 0279.3—2016电感耦合等离子体质谱法(ICP-MS)测定钡(Ba)、铍(Be)、铋(Bi)等15元素采用HNO_3-HF-HClO_4进行消解,消解后的样品采用王水溶解。实验发现地球化学样品中Se采用HNO_3-氢氟酸(HF)-HClO_4消解更加完全,消解后的样品采用王水溶解时,王水中含有的大量的氯离子(Cl~-)可以将Se(Ⅵ)还原为Se(Ⅳ)。因此HG-AFS测定Se和ICP-MS测定Ba, Be和Bi等15元素仅需一次消解,便可以分别进行测定。基于以上研究建立的外供H_2-HG-AFS测定地球化学样品中的Se的方法,检出限达到了0.007 mg·kg~(-1),精密度(n=12)在2.1%~5.3%之间。选取36个土壤和水系沉积物标准物质按照制定的方法进行测定,相对误差在-13.6%~16.9%,绝大部分误差在±10%以内,取得了非常满意的效果。  相似文献   

5.
温控湿法消解ICP-MS测定全血中铅镉硒砷汞5种微量元素   总被引:3,自引:0,他引:3  
采用温控HNO3-H2O2湿法消解,ICP-MS测定全血中Pb, Cd, Se, As, Hg 5种微量元素的含量。在选定的测试条件下,仪器系统稳定性良好,Pb等5种元素的检出限范围2~40 ng·L-1,全过程中样品均重复测定3次,RSD均在3%内。采用国家全血溶液标准物质GBW(E)09034-09036和人发标准物质GBW09101b中的相应元素进行质量控制,检测结果和推荐值相吻合。同时,应用本方法实测了湘西汞矿区34名村民全血中的5种元素的含量,结果表明:矿区村民Se和As处于正常水平,血Pb、血Cd、血Hg含量均偏高,有较高的健康风险,应当引起有关部门的重视。本方法快速、灵敏,精密度及准确度均符合要求,适于人体全血样中Pb, Cd, Se, As, Hg等微量元素的测定。  相似文献   

6.
肺癌和癌旁组织中55个元素的原子光谱分析   总被引:6,自引:3,他引:3  
建立了利用原子光谱技术测定人肺组织中55种元素的方法。样品采用冷消化过夜,温控电热板消解。其中49种元素利用电感耦合等离子体质谱(ICP-MS)进行测定;As和Se由原子荧光分光光度计(AFS)测定,K, Na, Ca和Mg由原子吸收分光光度计(AAS)测定。24个元素的测定值与牛肝和人发两种标准物质中的参考值基本吻合。除了Cr, Er和U三元素回收率略为偏高外,其余30种元素的加标回收率均在90%~110%之间。绝大多数元素的精密度在1.7%~10%之间。统计学分析结果表明,共有20种元素的含量在所测17对癌组织和癌旁组织之间具有显著性差异。此方法简便、快速、准确。  相似文献   

7.
膨润土是由比例为2∶1的Si—O四面体和Al—O八面体交替组成具有层状结构的硅酸盐天然黏土矿物,膨润土的多孔结构、化学组成、可交换离子类型以及较小的晶体尺寸,赋予了膨润土具有化学活性表面积大、阳离子交换容量大以及孔隙率高的独特性能,广泛应用于石化、冶金、食品、医药和环保等各个领域。在膨润土的开发利用过程中,其所含元素As可能通过迁移对人体健康构成潜在风险。采用硝酸-盐酸-氢氟酸对膨润土进行微波消解,加入高氯酸在电热板上对消解溶液继续进行低温消解,利用微波等离子体原子发射光谱(MP-AES)联用多模式样品引入系统(MSIS)测定膨润土中总As含量。采用25%(w/v)碘化钾为预还原溶液对As的形态进行预还原,将As(Ⅴ)还原为As(Ⅲ),利用硼氢化钠/氢氧化钠在MSIS中将As(Ⅲ)转变为气态氢化物(AsH3),通过优化MP-AES的最佳观测位置和雾化气流量,获得最佳分析性能,选择188.979 nm为As的分析波长避开了谱线重叠干扰,使用快速线性干扰校正(FLIC)模型校正了背景干扰,选择261.542 nm为内标元素Lu的分析波长校正了基体效应。As的检出限(LOD)为0.41 μg·L-1,通过测定国家标准参考物质对分析方法进行评价,As的测定值与标准参考物质的认定值一致,相对标准偏差(RSD)≤2.80%,验证了方法的准确性好,精密度高。对来自中国不同产地的12个膨润土的分析显示,所有样品中总As的浓度相对较低(As的平均含量在3.51~12.6 mg·kg-1之间),按照中华人民共和国国家标准GB 2760—2014食品安全国家标准食品添加剂膨润土中规定的总As浓度限量标准,所有膨润土样品中的As含量均没有超标。采用大气氮气为等离子体气的MP-AES降低了运行成本,提高了分析效率,为膨润土的质量控制提供了可靠的方法,具有运行安全稳定、操作简单快速、适用性强等优点。  相似文献   

8.
ICP-OES同时测定水性油墨中8种可溶性重金属元素   总被引:1,自引:1,他引:0  
建立了全谱直读电感耦合等离子体光谱(ICP-OES)测定5种不同颜色水性油墨中As、Ba、Cd、Cr、Hg、Pb、Sb、Se 8种可溶性重金属元素的分析方法,研究了元素分析谱线选择、背景校正扣除、样品基体及待测元素间干扰等因素.结果表明,基体元素对测定没有明显干扰;在选定的波长下测定,元素间也没有干扰.该方法快速,准确可靠,各元素检出限0.0018-0.026μg/mL,加标回收率为92.6%-101.8%,相对标准偏差RSD均小于2.0%,适于水性油墨中8种可溶性重金属的日常检验.  相似文献   

9.
研究应用电感耦合等离子体串联质谱(ICP-MS/MS)技术建立准确测定野生藜蒿中12个微量元素的分析方法。采用MS/MS模式,以O2为反应气,元素As和Se与O2发生质量转移反应生成AsO和SeO,通过测定AsO和SeO消除质谱干扰;以NH3/He为反应气,元素Cr,Mn,Fe,Co,Ni,Cu,Zn与NH3/He发生质量转移反应形成团簇离子,通过测定团簇离子消除质谱干扰。元素Cd,Hg和Pb采用标准模式进行测定。12个待测元素的校准曲线在0~200 μg·L-1范围内具有良好的线性关系,各元素的检出限为0.64~49.61 ng·L-1。通过测定国家标准物质芹菜(GBW10048),采用t检验法进行差异性检验表明,测定值与标准值之间无显著性差异,验证了方法的准确可靠性。各元素的加标回收率在92.0%~106.1%之间,相对标准偏差(RSD)为1.6%~4.9%。分析了来自国内不同地区的4个野生藜蒿样品,结果显示,不同来源样品中12个元素的含量各有差异,Mn,Fe,Zn的含量远高于其余九种元素,毒理性元素As,Cd,Hg和Pb的含量处于极低水平。方法能准确测定野生藜蒿中的多种微量元素,为野生藜蒿的食用营养和安全提供科学的理论依据。  相似文献   

10.
黄晓文  张念  黄小龙 《光谱实验室》2009,26(5):1095-1099
建立碰撞池ICP-MS测定大米中Ca、Mn、Fe、Cu、Ni、As、Se、Sr、Cd、Ba和Hg的分析方法。采用微波消解方法消解样品后直接进行ICP-MS分析,并采用碰撞池技术消除质谱干扰,混合内标溶液校正基体干扰和漂移。方法的精密度均小于5%,回收率为85%—113%,并对标准物质(大米)GBW 10010GSB-1进行方法验证,获得较满意的结果。本法快速、简单,能满足大米中常量、微量、痕量金属元素同时测定的分析需求。  相似文献   

11.
An analytical study is carried out to optimize X‐ray fluorescence (XRF) and flame atomic absorption spectrometry (FAAS) quantitative analysis of Zn, Pb, and S in ZnO samples commonly used to obtain industrial ceramic enamels. Pb and S in the raw materials often contaminate ZnO and are very detrimental in industrial applications. Thus, very accurate analytical determination of these elements in ceramic samples is extremely important. First of all, a mineralogical study by X‐ray diffraction (XRD) on the different components in these raw materials and the materials produced during the firing process is performed in order to establish the mineral forms in a reference sample for analysis by XRF spectrometry. The working conditions are optimized for XRF multielemental analysis, using the sample in the form of pellets, due to high loss on ignition (LOI) values. The preparation of suitable standards and working conditions for FAAS analysis have also been optimized. The content of these elements was determined by FAAS for the reference sample and several samples for industrial use, and the results were compared with those obtained by XRF. Comparison of the results obtained from XRF and FAAS analysis of Pb and Zn show more accurate values for FAAS. For ZnO, an accuracy of 0.11% with ±0.1% precision by FAAS and 0.46% accuracy with ±0.2% precision by XRF are found. For PbO, 1.06% accuracy and ±0.06% precision using FAAS and 5.6% accuracy and ±0.35% precision by XRF were found. For SO3 determined only by XRF, accuracy was 4.76% with ±0.25% precision. These values are highly satisfactory given that these two elements are only found in small proportions.  相似文献   

12.
铬、砷、硒、镉、锑、钡、汞和铅8种有害元素是玩具安全领域必检项目。目前,标准方法大多需采用湿化学法处理样品,再用仪器进行测试,前处理过程复杂,耗时长、成本高。EDXRF法具有无须样品前处理、对样品非破坏性、成本低、效率高等优点,已广泛用于电子电气产品中有害物质的快速筛选分析,但由于玩具材料和待测元素种类多,大多元素限量较低,目标元素间存在重叠干扰,导致难以准确测试,尚未见应用于玩具中8种有害元素的测定。通过研究分析线、滤光片、管电压、分析时间等测试条件的选择和样品厚度对结果的影响,并根据目标元素的特性,确定了最佳的3种条件组合方式。通过经验系数法校正了塑料中分析元素相互之间引起的吸收-增强效应,利用Rh康普顿散射线作为内标校正了样品的颗粒度效应,并通过干扰重叠系数法校正了元素间谱线重叠干扰。根据玩具常用塑料样品基体类型特性,选用聚乙烯(PE)和聚氯乙烯(PVC)两类塑料标准样品分别制作工作曲线,建立了EDXRF法快速测定玩具塑料中8种有害元素含量的新方法。各元素在7.6~1 298 mg·kg-1范围内线性良好,方法检出限在0.5~37 mg·kg-1之间,能够满足目前玩具安全标准限量筛选要求。采用PP,PE,ABS和PVC等不同玩具塑料样品验证了方法的准确度和精密度,并将样品测试结果与样品参考值比较,计算相对误差均在25%以内,除某样品中个别元素RSD(n=6)在9%~15%稍大外,其他样品各元素的RSD(n=6)均在6%以内,精密度较好。如将单个条件的测试时间从30 s延长到2 min后,所有样品测定结果RSD均可降至5%以下。本方法操作简便、成本低、快速、准确,可用于玩具塑料中有害元素的快速筛选分析。  相似文献   

13.
全反射X射线荧光光谱(TXRF)分析是一种应用广泛、经济快捷的多元素显微与痕量分析方法。随着现代科技机器自动化的快速发展,样品制备成为TXRF分析定量的关键问题。本实验以茶叶粉末为分析对象,探讨了在TXRF分析过程中分散剂、样品量及粒径对粉末悬浮样品的制样效果、制样过程重复性及测量准确性的影响。结果表明:(1)通过分析粒径范围大于180目的茶叶粉末样品的五个独立重复试样,测试了TXRF法的整体精密度,分析了仪器的稳定性与样品制备过程中的不确定度,结果表明不论在何种元素与浓度范围下,与样品制备步骤相关的不确定度对获得的结果的全局精度都有显著贡献(>60%),样品的制备是分析误差的主要来源;(2)通过将粒径范围大于180目的茶叶粉末样品分散于1% Triton X-100与去离子水两种分散剂中,对分散剂的影响进行了研究,相较于非离子型表面活性剂,去离子水重复性更好,RSD在2.45%~11.64%之间,更适合作为粒径大于180目的茶叶粉末样品的分散剂,使得中、高Z元素的定量更为准确;(3)通过添加不同质量的粉末样品于5 mL去离子水中对样品量进行分析。样品量过低会导致制样重复性较差,而过高的进样量会导致样品薄膜厚度超过射线的测量厚度,有可能不再处于全反射条件下。对于植物粉末样品20 mg/5 mL是一个较为合适的样品量;(4)通过对7种粒径范围的粉末样品进行测量分析,研究了粒径对测量结果的影响。在粒径小于180目的范围内净计数随粒径的减小而增大;在粒径小于200目的范围内精密度随粒径的减小而提升;除Mn之外的元素粒径对准确性未有显著影响;在80~200目的范围内,不确定度迅速降低,大于200目后不确定度低于10%。综合考虑净计数、精密性与准确性,在制样过程中粒径范围建议研磨至200~300目之间,该研究结果可为植物粉末样品制样方法提供有效借鉴。  相似文献   

14.
微波消解FAAS测定新疆出口番茄酱中的微量元素   总被引:2,自引:0,他引:2  
陈兆慧  解成喜  张旭龙 《光谱实验室》2007,24(1):I0042-I0044
采用微波消解试样,FAAS法对新疆4个厂家出口番茄酱中的微量元素进行测定.经过回收率和精密度试验,结果表明:6种微量元素的相对标准偏差在0.23%-2.10%;回收率在94.8%-104.5%;并以番茄叶的标准样品(ESP-1)进行比较测定,标准样品的测定值与参考值基本一致,该方法获得了满意的精密度和准确度.  相似文献   

15.
微波消解-ICP-AES测定植物样品中多种微量元素   总被引:2,自引:1,他引:1  
诸堃  王君  李刚 《光谱实验室》2009,26(5):1168-1171
用微波消解仪消解植物样品,ICP-AES同时测定样品中硼、硫、磷、钾、钠、钙、镁、铜、锌、锶、钡、锰、铁等13个元素。方法检出限为0.087-6.03μg/g,精密度(RSD%,n=12)为0.49%—2.28%。对大米、茶叶、豆角、紫菜、花粉、黄芪国家一级标准物质进行测定,测定值与推荐植相符。结果表明,该方法可以满足植物样品中微量元素测定的要求。  相似文献   

16.
本文采取在标样和试样中加入绝对量一致的内标元素控制的ICP-AES法,对合金中的多元组分进行同时测定。通过对Ag-Mg-Ni合金中Mg、Ni的分析研究和试样测定,获得较好的准确度、精密度,相对误差Mg<±0.5%,Ni<±3.0%,相对标准偏差均小于0.5%,能满足对合金分析的要求。适当调整称样量及待测溶液定容体积,可扩大测定范围。采用绝对量内标控制,大大减小了由称量和稀释溶液体积带入的误差,从而提高了分析的准确度和精密度  相似文献   

17.
锌冶炼浸出渣是湿法炼锌工艺产出的冶炼固废渣,占锌冶炼固废产出总量的75% 以上,因含有Zn,Cu,Pb,Ag,Cd和As等多种有价金属元素,其资源化利用潜力巨大.然而由于其成分含量不稳定,检测精度不足等原因,导致关键元素的资源转化效率难以保证,因此对浸出渣关键资源组分的精准定量分析在锌冶炼行业绿色发展方面具有重大意义....  相似文献   

18.
ICP-AES法测定古代车师人肋骨中的痕量元素   总被引:2,自引:0,他引:2  
近几十年来 ,古代人群的食谱研究已经成为现代科技考古学的一个重要组成部分 ,也是当前国际科技考古学研究领域的一项前沿性课题。人类骨骼的微量元素分析为重建古代居民的食谱提供了大量信息。本文用硝酸 盐酸消解样品 ,采用电感耦合等离子发射光谱仪 (ICP AES) ,在选定的最佳条件下 ,对新疆地区古代车师人肋骨中的Sr,Zn ,Ca ,Cu ,Mg,Fe ,Ba ,Mn等 8种痕量元素进行了测定 ,该方法采用一次溶样 ,多元素同时测定 ,回收率为 87 4 %~ 1 0 6 6 %之间。相对标准偏差为 0 5 %~ 3 3%。该方法简单 ,快捷可靠 ,适用于古代骨样品的测定 ,结果令人满意。其结果为考古学和人类学的研究提供了科学的依据。同时考察了不同酸度对分析结果的影响和共存元素间的相互干扰 ,此外还进行了精密度实验。  相似文献   

19.
双向视ICP-OES法同时测定褐煤中锗和一些主要成灰元素   总被引:3,自引:1,他引:2  
描述了ICP-OES(高频电感耦合等离子体光学发射光谱)同时测定褐煤中Ge和一些主要成灰元素Fe,Al,Ca,Mg,K,Na,Ti的方法。所使用的仪器是一台安装有双向视等离子体炬管和一个同时检测器的ICP光谱仪,这种技术允许分别在侧视和端视方式下同时测定主成分和微量元素。作者选取了适宜的仪器工作条件、选择了无干扰的分析谱线和合理地扣除了光谱背景,样品灰化后用HNO3/HF/HClO4混合酸消解,测定结果与国标方法吻合。仪器的检出限为0.000 39~0.10 μg·mL-1,方法的精密度RSD为0.79%~2.84%,样品平均回收率为92.38%。建立的方法可简便、快速、准确地对褐煤中锗及其他多种元素同时进行测定。  相似文献   

20.
ICP-AES法测定蚂蚁粉中多种微量元素   总被引:6,自引:1,他引:5  
研究了ICP-AES法测定蚂蚁粉中多种微量元素的方法,通过方法试验确认采用低温灰化法制备样品,不仅能满足ICP-AES法测定的要求,同时具有样品处理方法简单,快速,经济等优点,其方法的回收率在92.0-100.7%之间,精密度在0.20%-9.29%之间,实验数据证明该方法完全可以满足同类样品的微量元素检测要求。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号