首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Size-exclusion chromatography (SEC) enables measurement of the average molecular weights and molecular-weight distributions of polymers. Because these characteristics may, in turn, be correlated with important performance characteristics of plastics, SEC is an essential analytical technique for characterization of macromolecules. Although SEC is one of the oldest instrumental chromatographic techniques, it is still under continuous development, as a result of the great demand for increased resolution and faster analysis in SEC. Ultra-high-pressure size-exclusion chromatography (UHPSEC) was recently introduced to satisfy the growing demands of analytical chemists. Using instrumentation capable of generating very high pressures and columns packed with small particles, this technique enables greater separation efficiency and faster analysis than are achieved with conventional SEC. UHPSEC is especially advantageous for high-resolution analysis of oligomers, for very rapid polymer separations, and as a second dimension in comprehensive two-dimensional liquid chromatography of polymers. In this paper we discuss the benefits of UHPSEC for separation of macromolecules, with examples from the literature.  相似文献   

2.
Abstract

Fast HPLC offers a definite time advantage for analyses such as content uniformity which requires, in general, a routine analysis of as many as 30 samples and for the analysis of dosage forms of developmental drugs. The columns for Fast HPLC can be used with a minimal amount of modification to conventional HPLC hardware. The resolution obtainable with a Fast HPLC column is poorer than that of a conventional column. (All references to conventional columns in the article imply, unless otherwise indicated, those columns 15-30 cm in length and 3.9-4.6 mm i.d.) Attempts to modify a mobile phase to improve the resolution of a closely eluting peak resulted in retention times not too different from typical conventional columns. Although microbore columns offered improved resolution and a savings in both solvent and sample consumption, the utility of these columns is limited by the need for specialized hardware. Since the sample volume is not a limiting factor in a typical pharmaceutical analysis and overall cost savings from lesser solvent consumption are not significant in a majority of cases as solvent can be recycled, it is concluded that the Fast HPLC columns can play a more important role than the currently available microbore columns in laboratories engaged in pharmaceutical analysis, particularly at the product development stage.  相似文献   

3.
Large aggregates (Mr: 10(6)-10(7) g/mol) of human immunoglobulins are present in extremely small concentrations in IgG preparations (<0.1%). Traces of large protein aggregates cannot be determined by conventional size-exclusion chromatography (SEC) using UV detection due to limitations in sensitivity. The conventional analysis of IgG by SEC is limited to dimers and oligomers. Using light scattering it is possible to determine significant differences concerning the aggregate composition and the extent of protein aggregation in samples of different process steps. Two different pilot preparations were analyzed by SEC with UV and static light scattering detection and compared to dynamic light scattering in the batch mode. The change of large aggregates could be monitored and data were corroborated by dynamic light scattering.  相似文献   

4.
In size-exclusion chromatography (SEC), proteins and peptides are separated according to their molecular size in solution. SEC is especially useful as an effective fractionation step to separate a vast amount of impurities from the components of interest and/or as final step for the separation of purified proteins from their aggregates, in a so-called polishing step. However, the throughput in SEC is low compared to other chromatographic processes as good resolution can be achieved only with a limited feed volume (i.e., maximal approximately 5% of the column volume can be loaded). This limitation opposed widespread application of conventional SEC in industry despite its excellent separation potential. Therefore a continuous separation process (namely preparative continuous annular chromatography) was developed and compared to a conventional SEC system both using Superdex 200 prep grade as sorbent. An immunoglobulin G sample with a high content of aggregates was chosen as a model protein solution. The influence of the feed flow-rate, eluent flow-rate and rotation rate on the separation efficiency was investigated. The height equivalent to a theoretical plate was lower for preparative continuous annular chromatography which could be explained by reduced extra column band broadening. The packing quality was proved to be identical for both systems. The productivity of conventional batch SEC was lower compared to continuous SEC, consequently buffer consumption was higher in batch mode.  相似文献   

5.
基于体积排除色谱中测得的淋出体积和动态激光光散射中测得的平动扩散系数都直接依赖于高分子的流体力学体积这一事实,本文在理论上提出了一种把淋出体积分布和平动扩散系数分布二者结合起来标定体积排除色谱的新方法,并且在实验上通过对宽分布的聚苯乙烯标准样品的测试证实了该方法的可行性.  相似文献   

6.
The high-temperature gas chromatographic (GC) separation of several semivolatile compounds is studied with a short metal capillary column packed with fibrous material, having a polydimethylsiloxane coating thereon. Taking advantage of the excellent heat-resistance of the fiber and also the combination of the surface-deactivated metal capillary, a temperature-programmed separation up to 450 degrees C is successfully demonstrated for the separation of polymer standard samples. The average molecular weight of the commercially-available polymer standard samples for size exclusion chromatography (SEC) is estimated by high-temperature GC analysis and compared with the nominal value determined by a conventional SEC method. Although a slight deviation for the number-average molecular weight is observed between the GC and SEC analysis, the data for the weight-average molecular weight shows a good agreement in these methods. The results also suggest the future possibility of the fiber-packed metal capillary as a miniaturized GC column with an increased sample loading capacity.  相似文献   

7.
Abstract

A review is given of the use of low angle laser light scattering (LALLS) detection in conjunction with size exclusion chromatography (SEC) to measure polymer molecular weight distributions without conventional SEC column calibration methods. A summary of light scattering theory is presented, and instrument configurations and principles of operation are described for two LALLS photometers. Also discussed are the overall performance of the SEC/LALLS technique and data from selected applications.  相似文献   

8.
提供了一种体积排除色谱(SEC)的绝对定量分析方法以解决复杂的二元混合物组成的定量分析问题.首先对传统的SEC数据处理方法作了改进,将示差检测响应信号H(V)除以样品进样质量,得到单位质量的示差折光检测响应分布Hw(V)和累积分布Iw(V),这两个分布与试样的检测响应常数有关.然后将Hw(V)除以总面积,再得到常规的归一化分布F(V).混合物检测响应常数的不同,提供了一种从单独组分的Hw(V)或Iw(V)分布,运用加和计算共混物的Hw(V)或Iw(V)分布,得出二元混合物的组成.运算过程利用最小差方和的枚举计算方法,在一个自行编写的Mathcad程序工作单上进行.应用该方法对一种工业沥青和两种稀释剂配成的二元混合物作了范例分析,得到满意结果.  相似文献   

9.
Reversible dimer formation in size exclusion chromatography (SEC) can cause peak splitting, merging, tailing, and fronting. Such behavior can be predicted by the association rate and the dissociation rate relative to the convection rate. Slow association and dissociation result in separated monomer and dimer peaks. Fast association and slow dissociation result in one single dimer peak. Slow association and fast dissociation result in one single monomer peak. Intermediate association and dissociation result in a merged, broad peak with either fronting when monomers dominate or tailing when dimers dominate. A diagram based on the two relative rates is generated to predict general peak shape and retention behavior in SEC.  相似文献   

10.
The aim of the present study was to set‐up a Fast gas chromatography/mass spectrometry method for the analysis of cholesterol oxidation products (COPs). A silylated mixture of seven oxysterol standards was injected into a Fast GC/MS system. A capillary GC column (10 m×0.1 mm internal diameter×0.1 μm film thickness) coated with 95% dimethyl‐ and 5% diphenyl‐polysiloxane, was used. The method gave a fast (total analysis time=3.5 min) and satisfactory resolution (R>1.2) of the COPs standards, with a good repeatability and sensitivity, similar to those of conventional GC/MS; recoveries were tested on mice liver. Fast GC/MS method suitability for COPs analysis in food was also tested on an oxidized sardine fillet, which had been previously saponified and purified by NH2 solid‐phase extraction (SPE); a good repeatability and sensitivity was also obtained. The analytical performance of the Fast GC/MS method for the determination of COPs, together with the consequent significant reduction of the analysis time and consumables, demonstrates that Fast GC/MS represents a valid alternative to conventional GC/MS and evinces the great potential of such an analytical technique, which could be applied for both food and biological samples.  相似文献   

11.
A new one-step cleanup procedure, based on size-exclusion chromatography (SEC), usable for the extracts from accelerated solvent extraction (ASE), Soxhlet extraction, or ultrasonic extraction (USE), is described. The method is suitable for the determination of polycyclic aromatic hydrocarbons (PAHs), especially from very complicated plant matrices (e.g. pine needles, deciduous leaves, mosses). The main improvement compared with previous conventional procedures is that analyte peaks barely overlap with matrix peaks in the chromatograms and that it is a very rapid and simple one-step procedure with clearly improved analytical performance. Essential advantages of this SEC procedure are the sharper GC-MS chromatograms for the PAH fraction at retention times between 9.2 and 12.0 min, distinctly separated substance peaks resulting in better analysis, shorter running times, and lower solvent consumption.  相似文献   

12.
A 5 m x 50 microm capillary column with 0.05 microm stationary phase film thickness, with a calculated efficiency of almost 20,000 plates per metre (under optimum conditions), was used for very fasthigh resolution GC analysis of lime essential oil. The total analysis time of this volatile essential oil was less than 90 s. Fast GC is shown to be appropriate for essential oil quality assurance analysis, and quantitative results of key components are comparable with those obtained by using conventional GC analysis. The fast GC analysis is approximately 33 times faster than the conventional GC method.  相似文献   

13.
In the production of monoclonal antibodies, separate chains of the antibody are often present in the product mixture as well as other contaminating proteins. These fragments should be removed from the whole antibodies. This paper shows the purification of monoclonal immunoglobulin G (IgG) from its heavy chain contaminant. The heavy chain fragment is simulated experimentally using bovine serum albumin (BSA), which has approximately the same molecular weight. The purification is performed using traditional size-exclusion chromatography (SEC) and using surfactant-aided SEC (SASEC), testing two different surfactants (C(12)E(23) and Tween20) and two different gels (Sephacryl S200HR and Sephacryl S300 HR). Pulse experiments show that with SASEC both BSA and IgG are more distributed towards the solid phase than compared to using SEC. This effect is larger on IgG, the largest component than on BSA. As a consequence, azeotropes will be formed at a specific surfactant concentration. Above this concentration the selectivity is reversed and increased to values higher than obtained with conventional SEC. At 7.5% (w/w) of C(12)E(23), BSA actually elutes before IgG. These experiments further show that when using SASEC larger productivity, higher yields and lower solvent consumption can be achieved without loss of purity of IgG when compared to conventional SEC. Mathematical simulation of the separation of BSA and IgG using simulated moving bed (SMB) chromatography indicates a large increase in productivity when applying a surfactant gradient in SASEC SMB compared to conventional isocratic SEC-SMB. Furthermore, solvent consumption reductions with a factor 15 prove possible as well as concentrating the IgG by a factor 2.  相似文献   

14.
15.
Toxicology is a classic field of forensic medicine. Forensic toxicology includes the analysis of medical and illegal drugs and dangerous substances in order of courts, investigating authorities and hospitals. Fast and easy immunological techniques for assying drug familys or single drugs are available. The conventional methods for detection of drugs are generally instrumental procedures such as gas chromatography, high‐performance liquid chromatography and chromatography‐mass spectrometry.  相似文献   

16.
Liquid chromatography of polymers is traditionally a slow technique with analysis times of typically 30 min per sample. For the application of liquid chromatographic techniques to combinatorial materials research the analysis time per sample must be reduced considerably. Analysis time in SEC can be reduced to about 2 min per sample when high‐throughput columns are used. For HPLC small columns with improved separation efficiencies can be used. As compared to conventional technology, time savings of more than 80% are achieved.

Chromatogram from conventional SEC column compared to high‐speed SEC column tested on an identical instrument with polystyrene standards in THF.  相似文献   


17.
The performance of size-exclusion electrochromatography (SEEC) for the mass distribution analysis of synthetic polymers was studied and compared to conventional, pressure-driven size-exclusion chromatography (SEC). Electroosmotic flow control, within-day, day-to-day and column-to-column repeatability were determined for SEEC with respect to retention and separation efficiency. It was shown that by using the retention ratio instead of the migration time, the precision of the mass distribution calculations is sufficiently high, and that similar distributions were obtained for a sample analyzed by pressure-driven SEC and by SEEC. Furthermore, hexafluoroisopropanol was demonstrated to be a new and potent solvent for SEEC. It was used for the separation of narrow polymethylmethacrylate standards and several commercially important polymers such as polycarbonate, polycaprolactam and poly(ethylene terephthalate), using UV detection in the deep UV region (195-230 nm).  相似文献   

18.
Nanogels are highly branched, swellable polymer structures with average diameters between 1 and 100nm. Size-exclusion chromatography (SEC) fractionates materials in this size range, and it is commonly used to measure nanogel molar mass distributions. For many nanogel applications, it may be more important to calculate the particle size distribution from the SEC data than it is to calculate the molar mass distribution. Other useful nanogel property distributions include particle shape, area, and volume, as well as polymer volume fraction per particle. All can be obtained from multi-detector SEC data with proper calibration and data analysis methods. This work develops the basic equations for calculating several of these differential and cumulative property distributions and applies them to SEC data from the analysis of polymeric nanogels. The methods are analogous to those used to calculate the more familiar SEC molar mass distributions. Calibration methods and characteristics of the distributions are discussed, and the effects of detector noise and mismatched concentration and molar mass sensitive detector signals are examined.  相似文献   

19.
In recent years, two-dimensional liquid chromatography (2D-LC) has been used increasingly for the analysis of synthetic polymers. A 2D-LC analysis provides richer information than a single chromatography analysis at the cost of longer analysis time. The time required for a comprehensive 2D-LC analysis is essentially proportional to the analysis time of the second dimension separation. Many of 2D-LC analyses of synthetic polymers have employed size exclusion chromatography (SEC) for the second-dimension analysis due to the relatively short analysis time in addition to the wide use in the polymer analysis. Nonetheless, short SEC columns are often used for 2D-LC analyses to reduce the separation time, which inevitably deteriorates the resolution. In this study, we demonstrated that high temperature SEC can be employed as an efficient second-LC in the 2D-LC separation of synthetic polymers. By virtue of high temperature operation (low solvent viscosity and high diffusivity of the polymer molecules), a normal length SEC column can be used at high flow rate with little loss in resolution.  相似文献   

20.
蛋白质聚集现象是生物制药行业面临的重大问题之一,对蛋白质药物有效性、安全性、质量可控性有很大影响。体积排阻色谱技术是蛋白质药物及其聚集体检测分析的标准技术,具有操作简单、分离条件温和、基本不破坏蛋白质药物结构等优点。但由于蛋白质与固定相存在非特异性相互作用,采用该法检测时存在洗脱延迟、色谱峰拖尾、基线漂移、蛋白质回收率低等问题。该文介绍了体积排阻色谱的分离原理及实际应用,并对该技术在蛋白质药物检测中存在的非特异性吸附问题及相关方法优化做了简要概述。同时列举了几种与体积排阻色谱互补的可用于蛋白质药物聚集体分析的技术。最后,对体积排阻色谱技术的发展前景进行了展望。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号