首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
2.
A simple, rapid and reproducible reversed-phase high-performance liquid chromatographic method for the simultaneous determination of benzoic acid (BA), phenylacetic acid (PAA) and their respective glycine conjugates hippuric acid (HA) and phenaceturic acid (PA) in sheep urine is described. The procedure involves only direct injection of a diluted urine sample, thus obviating the need for an extraction step or an internal standard. The compounds were separated on a Nova-Pak C18 column with isocratic elution with acetate buffer (25 mM, pH 4.5)-methanol (95:5). A flow-rate of 1.0 ml/min, a column temperature of 35 degrees C and detection at 230 nm were employed. These conditions were optimized by investigating the effects of pH, molarity, methanol concentration in the mobile phase and column temperature on the resolution of the metabolites. The total analysis time was less than 15 min per sample. At a signal-to-noise ratio of 3 the detection limits for ten-fold diluted urine were 1.0 microgram/ml for BA and HA and 5.0 micrograms/ml for PAA and PA with a 20-microliters injection.  相似文献   

3.
The objective was to develop a simple HPLC method to quantify exenatide—a 39 amino acid residue incretin mimetic used in diabetes therapy. To date, only non‐validated, sometimes incomplete, gradient methods have been reported in the literature. Isocratic separation was achieved using a C4 column and a mixed solvent system, A–B–C (48:45:7, v/v/v; pH* 5.2), where A represents KH2PO4 (pH 4.5; 0.1 m ) and MeCN (60:40, v/v), B corresponds to NaClO4·H2O (pH 6.0; 0.2 m ) and MeCN (60:40, v/v), and C is water. Exenatide eluted at 3.64 min and the total run time was 6 min. The method was specific and the response was accurate, precise and linear from 0.75 to 25 µg/mL. It was used to quantify exenatide transport across intact and laser‐porated porcine skin in vitro as a function of laser fluence [0 (i.e. intact skin), 9 and 15 J/cm2, respectively]. Although no permeation was observed using intact skin, cumulative exenatide permeation after 8 h through laser porated skin was 9.6 ± 6.5 and 12.4 ± 6.4 µg/cm2 at fluences of 9 and 15 J/cm2, respectively. This is the first validated isocratic method for exenatide quantification and it may be of use in quality control analysis and with other biological matrices. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

4.
A high-performance liquid chromatographic (HPLC) assay method for assessing the degradation of tolmetin (TLM) is developed and validated under acidic, basic, and photoirradiated conditions. The HPLC method includes an Inertsil 5 ODS-3V column (250- x 4.6-mm i.d.), guard column of Inertsil 7 ODS-3V (50- x 4.6-mm i.d.), mobile phase of CH(3)OH-1% HOAc (64:36, v/v), and UV detection at 254 nm. The developed method satisfies the system suitability criteria, peak integrity, and resolution for the parent drug and its degradants. The established assay method exhibits good selectivity and specificity suitable for stability measurements. From the intra- and interday tests of six replicates, the coefficients of variation are between 0.20% and 1.77% for the former, and 0.12% and 3.40% for the latter. Recoveries are found to be 98.7-101.7%. TLM is determined to be more reactive when exposed to light and acidic conditions, yet TLM is stable in a basic medium. A kinetic study of the photodegradation of TLM shows that it follows an apparent first-order reaction in three alcoholic solvents.  相似文献   

5.
6.
Clarithromycin is a very important macrolide antibiotic used to treat bacterial infections in human and veterinary medicine. This study reports the development and validation of cost-effective, simple, precise, accurate, and robust high-performance liquid chromatography (HPLC) for the determination of clarithromycin (CLA) in tablets. Reversed-phase chromatography was conducted using a standard column at 55°C with ultraviolet detection at 215 nm. A mobile phase consisting of acetonitrile –2-methyl-2-propanol –potassium phosphate buffer was used at a flow rate of 1.0 mL/min. The proposed method displayed good linearity, precision, accuracy, robustness, and specificity. The present HPLC was compared with capillary electrophoresis and bioassay methods and the results indicated that there was no significant difference between these methods. Moreover, the obtained results demonstrated the validity of the isocratic HPLC, which allows reliable quantitation of CLA in pharmaceutical samples. Thus, it can be used as a substitute alternative methodology for the routine quality control of this medicine, in situations where other methods are less accessible in the laboratory.  相似文献   

7.
Analytical and Bioanalytical Chemistry - In the study presented, a simple analytical method for the direct determination of glycine in immunoglobulins by hydrophilic interaction liquid...  相似文献   

8.
Styrax camporum Pohl, known in Brazil as 'estoraque do campo' or 'cuia de brejo', has been used in the treatment of gastrointestinal diseases. The therapeutic action of S. camporum has been attributed to the ethyl acetate fraction, although the chemical composition of this fraction has not yet been analyzed. In this study, a high-performance liquid chromatography photodiode array detection (HPLC-PAD) method for analysis of Brazilian Styrax species has been developed. The compounds egonol (1) and homoegonol (2) were found to be present in all the samples investigated by HPLC. These compounds were isolated by open column chromatography followed by preparative TLC, and were identified by 1H NMR. Compounds 1 and 2 were thus proposed as phytochemical markers for Styrax, owing to their biological properties and presence in other Styrax species. The developed method has been validated and successfully applied for quantification of 1 and 2 in S. camporum dried leaves and crude ethanolic extracts from S. ferrugineus and S. pohlii aerial parts.  相似文献   

9.
A high-performance liquid chromatographic (HPLC) method for the determination of ornithine conjugation of some carboxylic acids in vitro has been developed. The ornithine conjugates of benzoic acid, p-nitrobenzoic acid, furancarboxylic acid and phenylacetic acid in an incubation mixture with kidney mitochondria were well separated on a reversed-phase C18 column using a mixture of 10 mM ammonium acetate buffer and methanol as the mobile phase. In addition, by varying the pH of the mobile phase and utilizing the absorption wavelengths (nm) of the conjugates it was possible to resolve and specifically detect each conjugate. The calibration curves were linear in the range of 0.2-16 micrograms/ml for all compounds and the detection limits were about 50 ng/ml except for the ornithine conjugate of phenyl acetic acid (S/N = 2). The ornithine conjugation of some carboxylic acids with chicken kidney mitochondria were determined by this assay method. The activity of ornithine conjugation of benzoic acid, furancarboxylic acid, p-nitrobenzoic acid and phenylacetic acid were 14.5, 5.5, 0.5 and 6.9 nmol/mg of protein, respectively. Moreover, the ornithine conjugation and the glycine conjugation of benzoic acid were examined in birds and rodents. The ornithine conjugation was observed only in chicken (14.5 nmol/mg of protein) and mallard (0.99 nmol/mg of protein).  相似文献   

10.
A new high-performance liquid chromatography method was developed and validated for the quantitation of gliclazide and repaglinide in pharmaceutical formulations. Determination was performed using a LiChroCART RP-18 column, a mobile phase containing acetonitrile-phosphate buffer (pH 2.1; 60 + 40, v/v), and ultraviolet (UV) detection at 225 nm. Repaglinide was used as an internal standard for gliclazide determination and gliclazide for repaglinide assay. The method was validated with respect to linearity, precision, robustness, ruggedness, accuracy, and specificity. The calibration graphs ranged from 0.015 to 0.09 mg/mL for gliclazide and 0.06 to 0.36 mg/mL for repaglinide. Intra- and interday relative standard deviation values for the standard solutions were 0.70 and 1.01% for gliclazide and 0.78 and 0.93% for repaglinide, respectively. Total recoveries of gliclazide and repaglinide from the laboratory-prepared mixtures were 99.82 +/- 0.58 and 101.50 +/- 0.46% for gliclazide and repaglinide, respectively [mean +/- standard deviation (SD)]. In forced degradation studies, the effect of acid, base, oxidation, UV light, and temperature on both drugs was also investigated. Finally, the method was applied for the quality control of commercial gliclazide and repaglinide tablets. Total recovery was 100.40 +/- 0.35 and 104.46 +/- 0.23% for gliclazide and repaglinide, respectively (mean +/- SD).  相似文献   

11.
The mobilities of several free and conjugated 5 beta-bile acids, cholesterol and analogues, and alpha, beta-unsaturated sterols and steroidal acids have been investigated with a microbore reversed-phase high-performance liquid chromatographic column (50 cm X 1 mm I.D., 12% C18) with appropriate solvent mixtures at flow-rates of 50-100 microliter/min and a UV monitor set at 193, 198, 212, or 243 nm. With a solvent mixture of 2-propanol-10 mM phosphate buffer, pH 7.0 (160:340) bile acids or their conjugates were separated in a manner similar to those by microBondapak columns (10% C18). The lower detection limit of the conjugates was 20 pmoles with the UV detector set at 193 nm, whereas the lower limit for alpha, beta-unsaturated keto sterols or steroidal acids was 5 pmoles at 243 nm. The detection limit for cholesterol with the UV monitor at 198 nm was 10 pmoles. Contributions of substituent groups of sterols to their time of elution (capacity factor) were calculated for several substituted 4-cholesten-3-ones.  相似文献   

12.
Ganciclovir is a nucleoside analogue widely used in the treatment of cytomegalovirus infections, which affects mainly immunocompromised patients. Recently, new pharmaceutical dosage forms based on the use of albumin nanoparticles have been developed for improving the efficacy of this drug. The aim of this study was to develop an analytical HPLC method for the determination of ganciclovir in both pharmaceuticals (i.e. albumin nanoparticles) and biological medium samples. The chromatography was performed on a reversed-phase encapped column (LiChrospher Select B C8) with a mobile phase consisting of acetonitrile in 0.05 M ammonium acetate (pH 6.5; 2: 98, v/v). Acyclovir was used as internal standard and the detection wavelength was 254 nm. The limit of quantitation of ganciclovir was 50 ng/ml and the average recoveries over a concentration range of 0.05–10 μg/ml ranged from 98 to 102%. Precision did not exceed 5%. In summary, this assay is a selective, sensitive and reproducible method for the determination of the ganciclovir in albumin nanoparticles. It can be successfully applied to the estimation of the ganciclovir uptake by cultured human corneal fibroblasts.  相似文献   

13.
A procedure was proposed for the determination of free bile acids and their conjugates in blood plasma by the reversed-phase HPLC using the column Lichrospher 100 RP-18 (250 + 4.6 mm) with gradient elution and UV-detection at 206 nm. The procedure allowed the simultaneous determination of diagnostically important cholic acids, tauro-and glyco-cholates in blood plasma of patients with no preliminary separation of the analytes into subtypes. The bile acids and their conjugates were isolated from the sample matrix by solid phase extraction in a Sep-Pack C18 cartridge. The limits of detection were 0.11–0.15 mM for free acids and 0.015–0.025 mM for conjugates.  相似文献   

14.
High-performance liquid chromatography is a very powerful technique for the separation and isolation of nucleic acids. Nucleic acids can be generally characterized as long, negatively charged polymers with hydrophobic nucleobases. Chromatographic processes which use electrostatic interactions (anion-exchange), hydrophobic interactions (reversed-phase or salting-out) or both types of interactions (mixed-mode) are most effective for resolution of these materials.  相似文献   

15.
A four-step development, optimization and validation strategy for high-performance liquid chromatography (HPLC) fingerprints of Ginkgo biloba extract is described. A suitable chromatographic system was selected first. The following step was performing a screening design to select important parameters. After selecting some controllable parameters and their range to further optimize, gradient optimization with uniform design was done. At last, method validation including determination of injection precision, repeatability, and a sample stability test, was performed. Through this effective and integrated four-step method, a feasible and reliable HPLC fingerprint to identify and assess the Ginkgo biloba quality can easily be established using a linear gradient elution with acetonitrile/0.1% phosphoric acid (from 14/86 to 30/70, v/v, in 40 min) as mobile phase, a column temperature of 30 degrees C and a detection wavelength of 350 nm. The strategy can also be applied for the development of fingerprints in the quality control of other herbal medicines.  相似文献   

16.
A method is described for the simultaneous determination of major bile acids by high-performance liquid chromatography without prior hydrolysis. A mixture of bile acids is divided into the free, glyco- and tauro-conjugate groups by thin-layer chromatography. Separation of each group into cholate, ursodeoxycholate, chenodeoxycholate, deoxycholate and lithocholate is attained in two stages on a muBondapak C18 column; first, 0.3% ammonium carbonate-acetonitrile (9:4) is used as a mobile phase for the separation of the last three compounds. Subsequently cholate and ursodeoxycholate are resolved by chromatography in 0.3% ammonium carbonate-acetonitrile (11:4).  相似文献   

17.
The present study describes a rapid and sensitive HPLC method for the quantification of huperzine A (HupA) in Huperzia crispata (Huperziaceae). The sample extraction and preparation involved a simple, time-saving, single-solvent extraction, with each sample being analyzed within 12 min. The mobile phase was ammonium acetate (0.1 M, pH 6.0)--methanol (64 + 36, v/v) at a flow rate of 1.0 mL/min. Detection was at 308 nm. The calibration curve was linear from 0.049 to 7.84 microg (R2 = 0.9997), with intraday and interday precision RSD of less than 2%. The extraction recovery rate was over 98.49%. Quantification of HupA was performed using this modified method, and the content of HupA was 1.86 times higher in the whole plant of H. crispata (218.17 +/- 1.55 microg/g) than in that of H. serrata (117.03 +/- 2.97 microg/g). In the whole plant of H. crispata, HupA mainly accumulated in the actively growing shoot tips, the apical bud, and the 10 youngest leaves, reaching 455.23 +/- 2.97 microg/g. The content of HupA in the samples from sunshine-sheltered sites was 3.45 times higher than in that from sunshine-abundant sites. The satisfactory results indicate that this modified method can be applied in the quality control of large-scale Huperziaceae plant extracts and that changes should be made in the cultivation of H. crispata so as to maximize the production of HupA.  相似文献   

18.
A qualitative and quantitative analysis of the conjugated 1 beta- and 6 alpha-hydroxy bile acids, including common bile acids, in human urine using high-performance liquid chromatography with chemiluminescence detection is described. After extraction of urine with C18 silica cartridges, the bile acids were separated into non-conjugated, glycine, taurine and sulphate fractions by ion-exchange chromatography on a lipophilic gel. Solvolysis of the sulphate was carried out by treatment with trifluoroethanol in acetone containing hydrochloric acid, and the liberated amino acid conjugates were fractionated again. The individual bile acids were separated on a reversed-phase C18 column (Bile Pak II), with detection by an immobilized 3 alpha-hydroxysteroid dehydrogenase enzyme reactor and chemiluminescence reaction of the generated NADH using 1-methoxy-5-methylphenazinium methylsulphate-isoluminol-microperoxidase system. The assay method showed the detection limits ranging from 8 to 250 pmol for the bile acids tested. Analysis of urine samples obtained from newborns, non-pregnant women and women in late pregnancy showed a large difference in bile acid composition and conjugation mode, suggesting that bile acid metabolism is different during fetal and neonatal periods.  相似文献   

19.
A new, simple and sensitive high-performance liquid chromatographic (HPLC) method was developed for the determination of chamazulene carboxylic acid (CCA) in serum. The technique is based on a single liquid-liquid extraction of the substance using ibuprofen as internal standard (I.S.). The separation was achieved on a C(18) reversed-phase column using acetonitrile/water (4:6, pH 3) as mobile phase. The effluent was monitored at 221 and 286 nm. The calibration curves were linear over the concentration range of 0.1-30 microg/ml. The intra- and inter-day RSDs were in all cases less than 15 and 11%, respectively. The limit of quantitation was 0.1 microg/ml. The assay was developed and validated to be applied in a pharmacokinetic study in healthy volunteers.  相似文献   

20.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号