首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
倪海月  任世学  方桂珍  马艳丽 《色谱》2016,34(9):933-939
采用反气相色谱(IGC)法,以聚乙烯醇(PVA)为固定相,脂肪族、芳香族、醇、酮及卤代烃5类18种化合物为探针分子,研究PVA的溶解性质并获得了PVA在383.15~423.15 K范围内的溶解度参数(δ2)及相关热力学性质,并与Hansen溶解度参数法(HSP)测得的溶解度参数(δT)进行比较。结果表明,5类溶剂对PVA溶解能力的趋势为酮类 >醇类 >卤代烃、芳香类、脂肪族类>脂环族,卤代烃、芳香类和脂肪族类溶剂的溶解能力相似;在测试温度范围内PVA的δ2随温度升高而增加;采用IGC法外推出室温(298.15 K)下PVA的δ2为27.69 (J/cm30.5,与HSP法测得室温下PVA的δT(27.77 (J/cm30.5)一致。PVA溶解度参数及相关热力学参数的研究为其应用及相关研究提供了定量依据。  相似文献   

2.
Fourier transform infrared (FTIR) spectroscopic imaging was used to study the initial diffusion of different solvents in cellulose acetate butyrate (CAB) films containing different amounts of acetyl and butyryl substituents. Different solvents and solvent/non-solvent mixtures were also studied. The FTIR imaging system allowed acquisition of sequential images of the CAB films as solvent penetration proceeded without disturbing the system. The interface between the non-swollen polymer and the initial swelling front could be identified using multivariate data analysis tools. For a series of ketone solvents the initial diffusion coefficients and diffusion rates could be quantified and were found to be related to the polar and hydrogen interaction parameters in the Hansen solubility parameters of the solvents. For the solvent/non-solvent system the initial diffusion rate decreased less than linearly with the weight-percent of non-solvent present in the solution, which probably was due to the swelling characteristic of the non-solvent. For a given solvent, increasing the butyryl content of the CAB increased the initial diffusion rate. Increasing the butyryl content from 17 wt.% butyryl to 37 wt.% butyryl produced a considerably larger increase in initial diffusion rate compared to an increase in butyryl content from 37 wt.% to 50 wt.% butyryl.  相似文献   

3.
A simple, specific, sensitive, validated method was developed using liquid chromatography with tandem mass spectrometry with electrospray ionization of human plasma for the simultaneous estimation of drugs (simvastatin, ramipril, atenolol, hydrochlorothiazide, and aspirin) of PolycapTM capsule used in cardiovascular therapy. The interaction of these actives including internal standards between the stationary and mobile phase were investigated using Hansen solubility parameters. Chromatographic separation was performed on Phenomenex Synergi Polar‐RP (30 × 2 mm, 4 μm) column with a gradient mobile phase composition of acetonitrile and 5 mM ammonium formate for positive mode and 0.1% formic acid in both water and acetonitrile for negative mode. The flow rate and runtime were 1.0 mL/min and 3.5 min, respectively. Sample extraction was done by protein precipitation using acetonitrile, enabling a fast analysis. The calibration ranges from 0.1 to 100, 0.1 to 100, and 1 to 1000 ng/mL for simvastatin, ramipril, and atenolol using internal standard carbamazepine in positive mode, respectively, whereas it was 0.3–300 and 2–2000 ng/mL for hydrochlorothiazide and aspirin using internal standard 7‐hydroxy coumarin in negative mode, respectively. Hansen solubility parameters can be used as a high‐throughput optimizing tool for column and mobile phase selection in bioanalysis. This validated bioanalytical method has the potential for future fixed dose combination based preclinical and clinical studies that can save analysis time.  相似文献   

4.
A sensitive and fast method for the determination of nitrous acid (HONO) in air is described. The method combines a continuous collection of nitrous acid into a thin film of absorption liquid in a cylindrical wet effluent diffusion denuder (CWEDD) and on-line analysis of collected nitrous acid at the denuder concentrate employing a flow-injection analysis (FIA) where nitrous acid is oxidized into peroxynitrous acid and a chemiluminescent light emitted during the reaction of peroxynitrite with luminol is detected. Various absorption solutions (carbonate, bicarbonate, phosphate) as well as deionized water were compared from point of view of collection efficiency of nitrous acid at the CWEDD and selectivity and sensitivity of nitrous acid determination in air.All tested liquids provide quantitative collection of HONO in the CWEDD at the air flow rate of 1 L min−1. The detection limit of nitrous acid of 15 ppt (v/v) is the same for all tested liquids. Small positive interference of nitrogen dioxide and peroxyacetylnitrate has been found. The lowest interference of NO2 was found for 1 × 10−4 M NaHCO3 (pH 6.4; 0.18%) while for deionized water interference of NO2 (0.28%) was slightly higher. The lowest interference of peroxyacetylnitrate was found for deionized water (1.46%). No enhanced formation of HONO inside the cylindrical wet effluent diffusion denuder was observed for simultaneous bringing of nitrogen dioxide together with phenol, p-cresol, guaiacol, catechol, o-nitrophenol as well as with n-octane, n-nonane, n-decane, isoprene, α-pinene, β-pinene, camphene, 3-carene, α-phellandrene, S-limonene, benzene, toluene or o-xylene in comparison with formation of HONO only in the presence NO2.Deionized water was chosen as the optimum absorption liquid for the sampling of atmospheric nitrous acid at the CWEDD as well as for FIA chemiluminescent detection. The time resolution is 70 s and the response time is 164 s. The calibration curve is linear over 4 orders of magnitude (0.045-450 ppb HONO). The CWEDD-FIA technique has been applied to the measurement of nitrous acid in urban air.  相似文献   

5.
The sorbent–eluent systems combined from eight polymeric sorbents and seven solvents as eluents were used for the extraction of phenol and its oxidation products from water samples. The individual interactions between sorbents, eluents and analytes were characterized by Hansen solubility parameters. Principal components analysis (PCA) was used for revealing the dominant interactions (dispersive, polar, and hydrogen bonding type) in sorbent–analyte–eluent systems. The importance of solubility parameters was also determined by a novel procedure based on sum of ranking differences (SRD). Although PCA and ranking by SRD are based on different principles and calculations, they have provided very similar results. The recovery in a given system has been predicted from the magnitudes of mutual interactions (sorbent–analyte, sorbent–eluent, analyte–eluent) by multiple linear regression.  相似文献   

6.
We have applied photoacoustic (PA) technique to study the thermal properties of porous silicon (PS) films formed on p-type Si substrates by electrochemical anodic etching. Four PS samples with close thicknesses but greatly different porosities (from 20 to 60%) were examined. From the dependences of the PA signals on the modulation frequency of excitation light measured under a transmission detection configuration (TDC), effective thermal diffusivities for the two-layered PS/Si samples were determined and found to decrease greatly from 0.095 to 0.020 cm2 s-1 as the porosity increased from 20 to 60%. This revised version was published online in August 2006 with corrections to the Cover Date.  相似文献   

7.
Molecular dynamics simulations were applied to investigate the diffusion behaviors of water molecules at temperatures ranging from 323 to 443 K inside amorphous polyacrylate. The results showed that the simulated diffusion coefficients and activation energies were similar to those of experiments. Moreover, the activation energy of water molecules at high temperatures was higher than that at low temperatures by 3.16 kcal mol?1, which was close to the hydrogen‐bonding energy between water and polyacrylate. An analysis of the experimental desorption curves of water molecules and their activation energies has confirmed that there are two forms of water molecules inside rubbery polyacrylate, namely, free water and bound water. In addition, it has been concluded that bound water molecules move from one polar group of polyacrylate to another, and this is followed by occasional jumps. Simulated information is very helpful in designing new polyacrylate latex systems and optimizing existent polyacrylate systems. © 2007 Wiley Periodicals, Inc. J Polym Sci Part B: Polym Phys 45: 884–891, 2007  相似文献   

8.
采用分子动力学(MD)方法研究了熔融Li(电极)-KCl(电解质)界面上离子的扩散行为。熔融界面上离子的扩散动力学通过离子质心的均方位移(MSD)和速度自相关函数(VACF)进行研究,扩散系数由MSD(t)函数线性区间的斜率和VACF(t)函数积分得到。模拟结果表明,在熔融的Li-KCl界面上,Li+离子在浓度梯度的驱动下穿过界面发生定向迁移,导致双电层的形成和外电路上电流的输出。Li+离子的扩散系数比K+和Cl-离子的大7~8倍,说明在界面上Li+离子是主要的载荷子,热电池的电荷传输机制主要与Li+离子的扩散运动有关。由Nernst-Einstein公式对电导率进行估算,由扩散到KCl层中的Li+离子产生的电导率约为0.4 S.cm-2,对应的电流密度估算值为3.27×105A.cm-2。  相似文献   

9.
A systematic comparison of the diffusion coefficients of cations (Al, Cd, Co, Cu, Mn, Ni, Pb, Zn) and oxyanions (Al, As, Mo, Sb, V, W) in open (ODL) and restricted (RDL) diffusive layers used by the DGT technique was undertaken. Diffusion coefficients were measured using both the diffusion cell (Dcell) method at pH 4.00 and the DGT time-series (DDGT) method at pH 4.01 and 7.04 (pH 8.30 was used instead of 7.04 for Al) using the Chelex-Metsorb mixed binding layer. The performance of Chelex-Metsorb as a new DGT binding layer for Al uptake was also evaluated for the first time. Reasonable agreement was observed between Dcell and DDGT measurements for both ODL and RDL, except for V and W. The ratios of Dcell/DDGT for V of 0.44 and 0.39, and for W of 0.66 and 0.63 with ODL and RDL respectively, were much lower due to the formation of a high proportion of polyoxometalate species at the higher concentrations required with the Dcell measurements. This is the first time that D values have been reported for several oxyanions using RDL. Except for Al at pH 8.30 with ODL, all DDGT measurements were retarded relative to diffusion coefficients in water (DW) for both diffusive hydrogels. Diffusion in RDL was further retarded compared with ODL, for all elements (0.66–0.78) with both methods. However, the degree of retardation observed changed for cations and anions at each pH. At pH 7.04 cations had a slightly higher DDGT and oxyanions had a slightly lower DDGT than at pH 4.01 for both ODL and RDL. It is proposed that this is due to partial formation of acrylic acid functional groups (pKa ≈4.5), which would be fully deprotonated at pH 7.04 (negative) and mostly protonated at pH 4.01 (neutral). As Al changes from being cationic at pH 4.01 to anionic at pH 8.30 the results were more complex.  相似文献   

10.
The influence of the sample preparation parameters (the choice of the solvent and of the matrix:analyte ratio) was investigated and optimal conditions were established for MALDI mass spectrometry analysis of the pristine low molecular weight polyvinyl acetate (PVAc). It was demonstrated that comparison of polymer’s and solvent’s Hansen solubility parameters could be used as a guide when choosing the solvent for MALDI sample preparation. The highest intensity PVAc signals were obtained when ethyl acetate was used as a solvent along with the lowest matrix–analyte ratio (2,5-dihydroxybenzoic acid was used as a matrix in all experiments). The structure of the PVAc was established with high accuracy using the matrix-assisted laser desorption/ionization-Fourier transform mass spectrometry (MALDI-FTMS) analysis. It was demonstrated that PVAc undergoes unimolecular decomposition by losing acetic acid molecules from its backbone under the conditions of FTMS measurements. Number and weight average molecular weights as well as polydispersity indices were determined with both MALDI-TOF and MALDI-FTMS methods. The sample preparation protocol developed was applied to the analysis of a chewing gum and the molecular weight and structure of the polyvinyl acetate present in the sample were established. Thus, it was shown that optimized MALDI mass spectrometry could be used successfully for characterization of polyvinyl acetate in commercially available chewing gum.  相似文献   

11.
A gold nanoparticle embedding technique is used to determine how vacuum and pressured carbon dioxide (CO2) affect polystyrene (PS) thin film properties. The pressured CO2 greatly increased the gold nanoparticle embedding depth, possibly due to a low cohesive energy density near the film surface. For the monodisperse PS used in this study (Mn = 214,000), two spin‐coated thin films with intimate contact can be bonded below the bulk glass transition temperature (Tg) under CO2 pressure when the embedded depth is larger than half of the gyration radius of PS molecules. © 2009 Wiley Periodicals, Inc. J Polym Sci Part B: Polym Phys 47: 1535–1542, 2009  相似文献   

12.
固态化合物熔盐电解冶金在21世纪初被提出后受到学术界和工业界的广泛关注.根据固态化合物电解的动态三相电化学界线模型,固态金属氧(硫)化物阴极在电解还原过程中,涉及O2?(S2?)在电解生成的多孔金属层中的液相扩散,但由于一直以来缺乏方便可靠的理论和实验方法,相关传质过程动力学的研究鲜有文献报道.本文引入多孔电极瞬时离子释放扩散模型,以粉末微腔电极为微型多孔电极,设计双电势阶跃实验研究了WS2在等摩尔比NaCl+KCl熔盐中电解时固态阴极中的液相扩散.实验结果与理论模型符合良好,973 K时,硫离子在孔隙率为69%的多孔金属钨层中的扩散系数为0.92×10?5 cm2/s,扩散活化能为53.4 kJ/mol.研究表明,二硫化钨在NaCl+KCl混盐体系中能够快速电解还原生成纳米金属钨,其中,S2?的扩散传质是整个电解过程的速度控制步骤.  相似文献   

13.
14.
The precise estimation of the degree of derivatization of functional groups in polymers is important for determining their macroscopic properties. In this work, the quantitative estimation of the extent of esterification of novolac copolymers with di-tert-butyl dicarbonate was studied. Although the extent of esterification has been calculated previously by quantifying the signals from FT-IR and UV-Vis spectroscopy, these were restricted to monitoring the progress of the derivatization process. The 13C NMR signal intensities from the inverse-gated 1H-decoupled NMR spectrum have been used recently for the quantitative estimation of the degree of esterification of polymers. An alternative methodology has been suggested by us based on the fully relaxed 1H chemical shift intensities. However, since the proton signals of novolac resins are generally broad and overlapping, the proton decoupled 13C NMR spectrum was used to identify the 1H NMR signals using the 2-D HSQC technique. A TOCSY experiment was also performed to confirm further the 1H NMR signal assignments and, finally, the deconvoluted 1H NMR spectrum was used for the calculation of the extent of derivatization.  相似文献   

15.
An amperometric pesticides inhibition biosensor has been developed and used for determination of pesticides in vegetable samples. To eliminate the interference of ascorbic acid, multilayer films of polyelectrolyte (chitosan/polystyrensulfonate) were coated on the glass carbon electrode. Then, acetylcholinesterase was immobilized on the electrode based on surface-treated nanoporous ZrO2/chitosan composite film as immobilization matrix. As a modified substrate, acetylthiocholine was hydrolysed by acetylcholinesterase and produced thiocholine which can be oxidized at +700?mV vs. SCE. Pesticides inhibit the activity of enzyme with an effect of decreasing of oxidation current. The experimental conditions were optimized. The electrode has a linear response to acetylthiocholine within 9.90?×?10?6 to 2.03?×?10?3?M. The electrode provided a linear response over a concentration range of 6.6?×?10?6 to 4.4?×?10?4?M for phoxim with a detection limit of 1.3?×?10?6?M, over a range of 1.0?×?10?8 to 5.9?×?10?7?M for malathion, and over a range of 8.6?×?10?6 to 5.2?×?10?4?M for dimethoate. This biosensor has been used to determine pesticides in a real vegetable sample.  相似文献   

16.
The synthesis of sequential full interpenetrating polymer networks (IPNs) based on poly (N‐isopropylacrylamide) (PNIPAAm) and negatively charged poly(N‐vinyl‐2‐pyrrolidone) (PNVP) was described and their swelling, drug release, and diffusion studies were investigated. PNIPAAm was used as a host network. According to swelling experiments, IPNs gave relatively lower swelling ratios compared to PNIPAAm hydrogel due to the higher cross‐linking density. Lidocaine (LD) was used as a model drug for the investigation of drug release behavior of IPNs. LD uptake of the IPNs were found to increase from 24 to 166 (mg LD / g dry gel) with increasing amount of PNIPAAm and AMPS contents in the IPN structure. It was observed that the specific interaction between drug and AMPS co‐monomer influenced the drug release profile. In the diffusion transport mechanism study in water, the results indicated that the swelling exponents n for all IPNs are in the range from 0.50 to 0.72. This implies that the swelling transport mechanism was transferred from Fickian to non‐Fickian transport, with increasing AMPS content and NIPAAm character in the IPN structure. In addition, diffusion of LD within the IPNs showed similar trend. The incorporation of AMPS leads to an increase in electrostatic interaction between charge sites on carboxylate ions and cationic LD molecules. Therefore, the highest diffusion coefficient (D) of drug was found for IPN2 sample. Copyright © 2007 John Wiley & Sons, Ltd.  相似文献   

17.
Sorption isotherms, sorption enthalpies, and diffusion coefficients for water in an 11 μm thick PEO/PAA multi-layer film have been measured at 30, 40, and 60 °C for relative humidities between 0 and 70%. All quantities were measured on the same film using the quartz crystal microbalance/heat conduction calorimeter. Water diffusion coefficients in the film are several orders of magnitude lower than in the separate components. Sorption isotherms are of type III at 30 and 40 °C and linear at 60 °C. Water vapor permeabilities are calculated as the product of Henry's law solubility and diffusion coefficient. The permeability of the PEO/PAA multilayer film is exceedingly low compared to other polymer films used as membranes. The enthalpy of water sorption determined from the sorption isotherms using the van’t Hoff relation is 32.9 ± 0.3 kJ/mol. Calorimetric enthalpies of water sorption range from 42 to 34 kJ/mol at 30 and 40 °C over the humidity range studied. The change in motional resistance, a quantity proportion to the loss compliance of the film, has also been recorded at all three temperatures, and a common trend is an increase in loss compliance with increasing relative humidity, indicating plasticization of the film by water.  相似文献   

18.
TiO2 nanoparticles were produced in the diffusion flame reactor, and the size and anatase/rutile content of TiO2 were examined by a Particle Size Analyzer and X-ray diffraction, respectively. Increase in fuel/O2 ratio, initial concentration of TiCl4 or total gas flow rate causes the larger particle size and the higher rutile composition. The photocatalytic activities of TiO2 powders were tested on the decompositions of phenol and toluene in the aqueous solution under UV irradiation. The degradation rate increases as the TiO2 particle size decreases and as the initial concentration of phenol or toluene increases. The photodegradation rate of phenol by TiO2 particles is higher than that of toluene at the same process conditions. The computational method was used to simulate the gas temperature, velocity and species mass fractions inside the diffusion flame reactor during synthesis of TiO2 nanoparticles. The measured and simulated temperature results were compared on several positions above the burner and both of them show good agreements. The typical contours of TiCl4, TiO2 mass fractions and gas velocities in flame reactor were presented.  相似文献   

19.
The concentration of an active pharmaceutical ingredient (povidone) in a commercial eyewash solution has been measured directly through a plastic (low-density polyethylene: LDPE) container using a wide area illumination (WAI) Raman scheme. The WAI scheme allows excitation using a 6 mm laser spot (focal length: 248 mm) that is designed to cover a wide sample area. As a result, it has the potential to improve the reliability Raman measurements by significantly enhancing representative sample interrogation, thus improving the reproducibility of sampling. It also decreases the sensitivity of sample placement with regard to the excitation focal plane. Simultaneously, isobutyric anhydride was placed in front of the bottles to use for a synchronous external standard configuration. This helps to correct the problematic variation of Raman intensity from the inherent fluctuation in laser power. Using the WAI Raman scheme combined with the synchronous standard method, the povidone concentration was successfully measured with spectral collection that was performed through a plastic barrier. The conventional Raman scheme was difficult to employ for the same purpose because of the degraded spectral reproducibility resulting from the smaller laser illumination area and the sensitivity of such an approach to the position of the sample bottle. The result from this study suggests that the WAI scheme exhibits a strong potential for the non-destructive quantitative analysis of pharmaceuticals measured directly in plastic containers. Preliminary work also shows that similar measurements can also be made in glass bottles. If implemented, this technique could be utilized as a simple and rugged method for quality assurance of final products in a manner consistent with Process analytical technology (PAT) requirements.  相似文献   

20.
Summary Comparative molecular field analysis (CoMFA) has been used as a three-dimensional quantitative structure-activity relationship (QSAR) method to correlate the affinities of several antagonists towards CCK-A receptors with their steric and electrostatic fields. In this publication, we describe, for the first time, a field-fit operation as an alignment technique. These results could serve as a guide for the design of new non-peptide antagonists.  相似文献   