首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到10条相似文献,搜索用时 39 毫秒
1.
Application of stable isotopes of water to studies of plant–soil interactions often requires a substantial preparatory step of extracting water from samples without fractionating isotopes. Online heating is an emerging approach for this need, but is relatively untested and major questions of how to best deliver standards and assess interference by organics have not been evaluated. We examined these issues in our application of measuring woody stem xylem of sagebrush using a Picarro laser spectrometer with online induction heating. We determined (1) effects of cryogenic compared to induction-heating extraction, (2) effects of delivery of standards on filter media compared to on woody stem sections, and (3) spectral interference from organic compounds for these approaches (and developed a technique to do so). Our results suggest that matching sample and standard media improves accuracy, but that isotopic values differ with the extraction method in ways that are not due to spectral interference from organics.  相似文献   

2.
Isotope ratios of carbon dioxide and water vapour in the near-surface air were continuously measured for one month in an urban area of the city of Nagoya in central Japan in September 2010 using laser spectroscopic techniques. During the passages of a typhoon and a stationary front in the observation period, remarkable changes in the isotope ratios of CO2 and water vapour were observed. The isotope ratios of both CO2 and water vapour decreased during the typhoon passage. The decreases can be attributed to the air coming from an industrial area and the rainout effects of the typhoon, respectively. During the passage of the stationary front, δ13C–CO2 and δ18O–CO2 increased, while δ2H–H2Ov and δ18O–H2Ov decreased. These changes can be attributed to the air coming from rural areas and the air surrounding the observational site changing from a subtropical air mass to a subpolar air mass during the passage of the stationary front. A clear relationship was observed between the isotopic CO2 and water vapour and the meteorological phenomena. Therefore, isotopic information of CO2 and H2Ov could be used as a tracer of meteorological information.  相似文献   

3.
We present a detailed comparison between subsequent versions of commercially available wavelength-scanned cavity ring-down water isotope analysers (L2120-i and L2130-i, Picarro Inc.). The analysers are used in parallel in a continuous mode by adaption of a low-volume flash evaporation module. Application of the analysers to ice-core analysis is assessed by comparison between continuous water isotope measurements of a glacial ice-core from Severnaya Zemlya with discrete isotope-ratio mass spectrometry measurements performed on parallel samples from the same ice-core. The great advances between instrument versions, particularly in the measurement of δ2H, allow the continuous technique to achieve the same high level of accuracy and precision obtained using traditional isotope spectrometry techniques in a fraction of the experiment time. However, when applied to continuous ice-core measurements, increased integration times result in a compromise of the achievable depth resolution of the ice-core records.  相似文献   

4.
Arctic and sub-arctic watersheds are undergoing significant changes due to recent climate warming and degrading permafrost, engendering enhanced monitoring of arctic rivers. Smaller catchments provide understanding of discharge, solute flux and groundwater recharge at the process level that contributes to an understanding of how larger arctic watersheds are responding to climate change. The North Klondike River, located in west central Yukon, is a sub-alpine permafrost catchment, which maintains an active hydrological monitoring station with a record of >40 years. In addition to being able to monitor intra-annual variability, this data set allows for more complex analysis of streamflow records. Streamflow data, geochemistry and stable isotope data for 2014 show a groundwater-dominated system, predominantly recharged during periods of snowmelt. Radiocarbon is shown to be a valuable tracer of soil zone recharge processes and carbon sources. Winter groundwater baseflow contributes 20?% of total annual discharge, and accounts for up to 50?% of total river discharge during the spring and summer months. Although total stream discharge remains unchanged, mean annual groundwater baseflow has increased over the 40-year monitoring period. Wavelet analysis reveals a catchment that responds to El Niño and longer solar cycles, as well as climatic shifts such as the Pacific Decadal Oscillation.

Dedicated to Professor Peter Fritz on the occasion of his 80th birthday  相似文献   

5.
The routine methods for stable oxygen and hydrogen isotope analysis of water involve water–CO2 gas equilibration and water reduction on hot metal (e.g. Zn, Cr, U) and subsequent mass spectrometric analysis of the evolved gases of CO2 and H2 for 18O/16O and 2H/1H ratios, respectively. Precise determination of the isotopic composition of water in brines with application of these standard methods is still problematic and technically often impossible due to detrimental influence of dissolved salts. The new method of brine desalination presented in this study overcomes the problem of the isotope salt effects encountered during the application of the routine techniques for the determination of the isotopic composition of high saline waters. The procedure combines two technical steps: (i) the chemical precipitation of Mg and Ca ions as insoluble non-hydroscopic fluorides, and (ii) the vacuum distillation of water from solution–precipitate mixture. The application of simple vacuum distillation allows full extraction of water and dehydration of remaining salts in a temperature range from 300 to 350?°C without hydrogen and oxygen isotope fractionation. The precision and accuracy of δ18O and δ2H determination of saline waters and brines with prior application of AgF desalination procedure is comparable with that usually obtained for fresh waters.  相似文献   

6.
A new technique for high-resolution simultaneous isotopic analysis of δ18O and δD in liquid water is presented. A continuous stream flash evaporator has been designed that is able to vapourise a stream of liquid water in a continuous mode and deliver a stable and finely controlled water vapour sample to a commercially available infrared cavity ring-down spectrometer. Injection of sub-microlitre amounts of the liquid water is achieved by pumping liquid water sample through a fused silica capillary and instantaneously vapourising it with 100% efficiency in a home-made oven at a temperature of 170?°C. The system's simplicity, low power consumption and low dead volume together with the possibility for automated unattended operation provides a solution for the calibration of laser instruments performing isotopic analysis of water vapour. Our work is mainly driven by the possibility to perform high-resolution online water isotopic analysis on continuous-flow analysis (CFA) systems typically used to analyse the chemical composition of ice cores drilled in polar regions. In the following, we describe the system's precision and stability and sensitivity to varying levels of sample size and we assess the observed memory effects. A test run with standard waters of different isotopic compositions is presented, demonstrating the ability to calibrate the spectrometer's measurements on a VSMOW scale with a relatively simple and fast procedure.  相似文献   

7.
ABSTRACT

We explored a novel doubly labelled water (DLW) method based on breath water (BW-DLW) in mice to determine whole body CO2 production and energy expenditure noninvasively. The BW-DLW method was compared to the DLW based on blood plasma. Mice (n?=?11, 43.5?±?4.6?g body mass (BM)) were administered orally a single bolus of doubly labelled water (1.2?g H218O kg BM?1 and 0.4?g 2H2O kg BM?1, 99 atom% (AP) 18O or 2H). To sample breath water, the mice were placed into a respiration vessel. The exhaled water vapour was condensed in a cold-trap. The isotope enrichments of breath water were compared with plasma samples. The 2H/1H and 18O/16O isotope ratios were measured by means of isotope ratio mass spectrometry. The CO2 production (RCO2) was calculated from the 2H and 18O enrichments in breath water and plasma over 5 days. The isotope enrichments of breath water vs. plasma were correlated (R2?=?0.89 for 2H and 0.95 for 18O) linearly. The RCO2 determined based on breath water and plasma was not different (113.2?±?12.7 vs. 111.4?±?11.0?mmol?d–1), respectively. In conclusion, the novel BW-DLW method is appropriate to obtain reliable estimates of RCO2 avoiding blood sampling.  相似文献   

8.
Stable isotopes of water (δ2H, δ18O) and δ13CTIC were used as a tool to trace the recharge processes, natural carbon (organic and inorganic) source and dynamics in the aquifers of the central Gangetic basin, India. Stable isotope (δ2H, δ18O) record of groundwater (n?=?105) revealed that the groundwater of Piedmont was recharged by meteoric origin before evaporation, while aquifers of the older and younger alluvium were recharged by water that had undergone evaporation loss. River Ganges and its tributaries passing through this area have very little contribution in recharging while ponds play no role in the recharging of adjacent aquifers. The connectivity of shallow aquifers of aquitard formation (comprised of clay/sandy clay with thin patches of fine grey sand), i.e. 25–60?m below ground level (bgl) with the main upper aquifer (at a depth of >120?m?bgl) was found to be higher in older and younger alluvium. Negative values of δ13CTIC (median ?9.6 ‰; range ?13.2 to ?5.4 ‰) and high TIC (median 35?mM; range 31–46?mM) coupled with low TOC (median 1.35?mg/L; range 0.99–1.77?mg/L) indicated acceleration in microbial activity in the younger alluvium, especially in the active floodplain of river Ganges and its proximity.  相似文献   

9.
New isotope laboratories can achieve the goal of reporting the same isotopic composition within analytical uncertainty for the same material analysed decades apart by (1) writing their own acceptance testing procedures and putting them into their mass spectrometric or laser-based isotope-ratio equipment procurement contract, (2) requiring a manufacturer to demonstrate acceptable performance using all sample ports provided with the instrumentation, (3) for each medium to be analysed, prepare two local reference materials substantially different in isotopic composition to encompass the range in isotopic composition expected in the laboratory and calibrated them with isotopic reference materials available from the International Atomic Energy Agency (IAEA) or the US National Institute of Standards and Technology (NIST), (4) using the optimum storage containers (for water samples, sealing in glass ampoules that are sterilised after sealing is satisfactory), (5) interspersing among sample unknowns local laboratory isotopic reference materials daily (internationally distributed isotopic reference materials can be ordered at three-year intervals, and can be used for elemental analyser analyses and other analyses that consume less than 1 mg of material) – this process applies to H, C, N, O, and S isotope ratios, (6) calculating isotopic compositions of unknowns by normalising isotopic data to that of local reference materials, which have been calibrated to internationally distributed isotopic reference materials, (7) reporting results on scales normalised to internationally distributed isotopic reference materials (where they are available) and providing to sample submitters the isotopic compositions of internationally distributed isotopic reference materials of the same substance had they been analysed with unknowns, (8) providing an audit trail in the laboratory for analytical results – this trail commonly will be in electronic format and might include a laboratory information management system, (9) making at regular intervals a complete backup of laboratory analytical data (both of samples logged into the laboratory and of mass spectrometric analyses), being sure to store one copy of this backup offsite, and (10) participating in interlaboratory comparison exercises sponsored by the IAEA and other agencies at regular intervals.  相似文献   

10.
The GasBench II peripheral along with MAT 253 combination provides a more sensitive platform for the determination of water isotope ratios. Here, we examined the role of adsorbed moisture within the gas chromatography (GC) column of the GasBench II on measurement uncertainties. The uncertainty in 18O/16O ratio measurements is determined by several factors, including the presence of water in the GC. The contamination of GC with water originating from samples as water vapour over a longer timeframe is a critical factor in determining the reproducibility of 18O/16O ratios in water samples. The shift in isotope ratios observed in the experiment under dry and wet conditions correlates strongly with the retention time of analyte CO2, indicating the effect of accumulated moisture. Two possible methods to circumvent or minimise the effect of adsorbed water on isotope ratios are presented here. The proposed methodology includes either the regular baking of the GC column at a higher temperature (120 °C) after analysis of a batch of 32 sample entries or conducting the experiment at a low GC column temperature (22.5 °C). The effects of water contamination on long-term reproducibility of reference water, with and without baking protocol, have been described.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号