共查询到20条相似文献,搜索用时 15 毫秒
1.
Olivia J. Maselli Diedrich Fritzsche Lawrence Layman Joseph R. McConnell Hanno Meyer 《Isotopes in environmental and health studies》2013,49(3):387-398
We present a detailed comparison between subsequent versions of commercially available wavelength-scanned cavity ring-down water isotope analysers (L2120-i and L2130-i, Picarro Inc.). The analysers are used in parallel in a continuous mode by adaption of a low-volume flash evaporation module. Application of the analysers to ice-core analysis is assessed by comparison between continuous water isotope measurements of a glacial ice-core from Severnaya Zemlya with discrete isotope-ratio mass spectrometry measurements performed on parallel samples from the same ice-core. The great advances between instrument versions, particularly in the measurement of δ2H, allow the continuous technique to achieve the same high level of accuracy and precision obtained using traditional isotope spectrometry techniques in a fraction of the experiment time. However, when applied to continuous ice-core measurements, increased integration times result in a compromise of the achievable depth resolution of the ice-core records. 相似文献
2.
Adam Porowski 《Isotopes in environmental and health studies》2019,55(1):41-55
The routine methods for stable oxygen and hydrogen isotope analysis of water involve water–CO2 gas equilibration and water reduction on hot metal (e.g. Zn, Cr, U) and subsequent mass spectrometric analysis of the evolved gases of CO2 and H2 for 18O/16O and 2H/1H ratios, respectively. Precise determination of the isotopic composition of water in brines with application of these standard methods is still problematic and technically often impossible due to detrimental influence of dissolved salts. The new method of brine desalination presented in this study overcomes the problem of the isotope salt effects encountered during the application of the routine techniques for the determination of the isotopic composition of high saline waters. The procedure combines two technical steps: (i) the chemical precipitation of Mg and Ca ions as insoluble non-hydroscopic fluorides, and (ii) the vacuum distillation of water from solution–precipitate mixture. The application of simple vacuum distillation allows full extraction of water and dehydration of remaining salts in a temperature range from 300 to 350?°C without hydrogen and oxygen isotope fractionation. The precision and accuracy of δ18O and δ2H determination of saline waters and brines with prior application of AgF desalination procedure is comparable with that usually obtained for fresh waters. 相似文献
3.
Watheq Al-Basheer AbdulAziz Al-Jalal Khaled Gasmi 《Isotopes in environmental and health studies》2018,54(1):106-112
The 18O/16O and 2H/1H ratios of 18 water brands representing the most popular bottled water brands in the Saudi market were measured using a system based on the latest advancements in tunable off-axis integrated cavity output diode laser spectroscopy (OA-ICOS) in the near-infrared spectral region. Utilizing δ18O and the δ2H values of locally produced water samples, a meteoric water line (δ2H?=?7.84 δ18O?+?2.11) was extracted and found to be consistent with the slope of the global meteoric water line (GMWL) and the geographic location of Saudi Arabia. 相似文献
4.
Pooja Devi Ashok Kumar Jain M. Someshwer Rao Bhishm Kumar 《Isotopes in environmental and health studies》2013,49(3):426-438
A continuous and reliable time series data of the stable isotopic composition of atmospheric moisture is an important requirement for the wider applicability of isotope mass balance methods in atmospheric and water balance studies. This requires routine sampling of atmospheric moisture by an appropriate technique and analysis of moisture for its isotopic composition. We have, therefore, used a much simpler method based on an isotope mass balance approach to derive the isotopic composition of atmospheric moisture using a class-A drying evaporation pan. We have carried out the study by collecting water samples from a class-A drying evaporation pan and also by collecting atmospheric moisture using the cryogenic trap method at the National Institute of Hydrology, Roorkee, India, during a pre-monsoon period. We compared the isotopic composition of atmospheric moisture obtained by using the class-A drying evaporation pan method with the cryogenic trap method. The results obtained from the evaporation pan water compare well with the cryogenic based method. Thus, the study establishes a cost-effective means of maintaining time series data of the isotopic composition of atmospheric moisture at meteorological observatories. The conclusions drawn in the present study are based on experiments conducted at Roorkee, India, and may be examined at other regions for its general applicability. 相似文献
5.
Ryuichi Wada Satoru Takanashi Yuichiro Nakai Tomoki Nakayama Mai Ouchi 《Isotopes in environmental and health studies》2016,52(6):603-618
We conducted continuous, high time-resolution measurements of CO2 and water vapour isotopologues (16O12C16O, 16O13C16O and 18O12C16O for CO2, and H218O for water vapour) in a red pine forest at the foot of Mt. Fuji for 9 days from the end of July 2010 using in situ absorption laser spectroscopy. The δ18O values in water vapour were estimated using the δ2H–δ18O relationship. At a scale of several days, the temporal variations in δ18O-CO2 and δ18O-H2O are similar. The orders of the daily Keeling plots are almost identical. A possible reason for the similar behaviour of δ18O-CO2 and δ18O-H2O is considered to be that the air masses with different water vapour isotopic ratios moved into the forest, and changed the atmosphere of the forest. A significant correlation was observed between δ18O-CO2 and δ13C-CO2 values at nighttime (r2≈0.9) due to mixing between soil (and/or leaf) respiration and tropospheric CO2. The ratios of the discrimination coefficients (Δa/Δ) for oxygen (Δa) and carbon (Δ) isotopes during photosynthesis were estimated in the range of 0.7–1.2 from the daytime correlations between δ18O-CO2 and δ13C-CO2 values. 相似文献
6.
Shannon P. O'Grady Lindsey E. Enright Janet E. Barnette Thure E. Cerling James R. Ehleringer 《Isotopes in environmental and health studies》2013,49(4):476-483
The isotope ratio analysis of body water often involves large sample numbers and lengthy sample processing. Here we demonstrate the ability of isotope ratio infrared spectroscopy (IRIS) to rapidly and accurately analyse the isotope ratios of water in urine. We analysed water extracted from human urine using traditional isotope ratio mass spectrometry (IRMS) and compared those values with IRIS-analysed extracted water and un-extracted urine. Regression analyses for δ2H and δ18O values between (1) extracted water analysed via IRMS and IRIS and (2) urine and extracted water analysed via IRIS were significant (R 2=0.99). These results indicate that cryogenic distillation of urine was not required for an accurate estimate of the isotopic composition of urine when using IRIS. 相似文献
7.
Hatem Elmarami Hanno Meyer Gudrun Massmann 《Isotopes in environmental and health studies》2017,53(2):184-197
Stable isotopes of hydrogen and oxygen are often used for water balance calculations of lakes. We present an approach combining the lake water balance with an isotope mass balance to constrain the sources and sinks of the water of a small dimictic lake subjected to eutrophication. Meteorological and hydraulic data in combination with measured isotope signatures of the different water compartments enabled to assess the degree of surface water/groundwater interaction and the amount of overland flow into the lake. Groundwater could be excluded as a lake water source, as its water level was always below the lake water level. In the absence of a channelled inflow, precipitation and overland flow were the remaining options, whereby the latter was only active during periods of exceptionally high rainfall. While the groundwater signatures adjacent to the lake showed an influence of lake water, the lake water balance itself indicated that the associated volumetric water loss to groundwater is rather negligible. In the present case, only a combined assessment of hydrological and isotopic data allowed for an accurate characterization of the studied lake and a quantification of its water sources and sinks, highlighting the importance of using more than one methodological approach for such a purpose. 相似文献
8.
Anna Pierchala Kazimierz Rozanski Marek Dulinski Zbigniew Gorczyca Michal Marzec Robert Czub 《Isotopes in environmental and health studies》2019,55(3):290-307
A thorough evaluation of measurement uncertainty together with control of short-term and long-term precision of measurements should be a basis of any successful quality assurance/quality control (QA/QC) strategy aimed at maintaining a high quality of the analytical process. Here we present the results of a comprehensive assessment of the analytical performance of a Picarro L2140-i CRDS laser spectrometer analysing δ2H, δ18O and δ17O in water. The assessment is based on results obtained during 15 months of continuous operation of this instrument (February 2017 to May 2018). The short-term precision of measured and derived quantities was 0.11, 0.036, 0.028, 0.23 ‰ and 11 per meg, for δ2H, δ18O, δ17O, d-excess and Δ17O, respectively, and is comparable to the precision reported by the manufacturer. The long-term precision of the L2140-i, defined as standard uncertainty of the time series of 153 analyses of a laboratory standard conducted throughout 15 months, was roughly two times lower (0.24, 0.053, 0.038, 0.37 ‰ and 21 per meg, for δ2H, δ18O, δ17O, d-excess and Δ17O). In-depth assessment of the measurement uncertainty of a single analysis revealed that assigned uncertainty of the calibration standards is an important component of the uncertainty budget, especially in case of δ2H analysis. 相似文献
9.
Vasileios Gkinis Trevor J. Popp Sigfus J. Johnsen Thomas Blunier 《Isotopes in environmental and health studies》2013,49(4):463-475
A new technique for high-resolution simultaneous isotopic analysis of δ18O and δD in liquid water is presented. A continuous stream flash evaporator has been designed that is able to vapourise a stream of liquid water in a continuous mode and deliver a stable and finely controlled water vapour sample to a commercially available infrared cavity ring-down spectrometer. Injection of sub-microlitre amounts of the liquid water is achieved by pumping liquid water sample through a fused silica capillary and instantaneously vapourising it with 100% efficiency in a home-made oven at a temperature of 170?°C. The system's simplicity, low power consumption and low dead volume together with the possibility for automated unattended operation provides a solution for the calibration of laser instruments performing isotopic analysis of water vapour. Our work is mainly driven by the possibility to perform high-resolution online water isotopic analysis on continuous-flow analysis (CFA) systems typically used to analyse the chemical composition of ice cores drilled in polar regions. In the following, we describe the system's precision and stability and sensitivity to varying levels of sample size and we assess the observed memory effects. A test run with standard waters of different isotopic compositions is presented, demonstrating the ability to calibrate the spectrometer's measurements on a VSMOW scale with a relatively simple and fast procedure. 相似文献
10.
Yuliya Vystavna Dmytro Diadin Frédéric Huneau 《Isotopes in environmental and health studies》2018,54(2):147-167
Stable isotopes of hydrogen (2H) and oxygen (18O) of the water molecule were used to assess the relationship between precipitation, surface water and groundwater in a large Russia/Ukraine trans-boundary river basin. Precipitation was sampled from November 2013 to February 2015, and surface water and groundwater were sampled during high and low flow in 2014. A local meteoric water line was defined for the Ukrainian part of the basin. The isotopic seasonality in precipitation was evident with depletion in heavy isotopes in November–March and an enrichment in April–October, indicating continental and temperature effects. Surface water was enriched in stable water isotopes from upstream to downstream sites due to progressive evaporation. Stable water isotopes in groundwater indicated that recharge occurs mainly during winter and spring. A one-year data set is probably not sufficient to report the seasonality of groundwater recharge, but this survey can be used to identify the stable water isotopes framework in a weakly gauged basin for further hydrological and geochemical studies. 相似文献
11.
Phil-Goo Kang Bernhard Mayer Myron J. Mitchell 《Isotopes in environmental and health studies》2013,49(3):410-420
Pretreatment methods for measuring stable sulphur (δ34S) and oxygen (δ18O) isotope ratios of dissolved sulphate from watersheds have evolved throughout the last few decades. The current study evaluated if there are differences in the measured stable S and O isotope values of dissolved sulphate from forested watersheds when pretreated using three different methods: Method 1 (M1): adsorb sulphate on anion exchange resins and send directly to isotope facility; Method 2 (M2): adsorb sulphate on anion exchange resins, extract sulphate from anion exchange resins, and send the produced BaSO4 to the isotope facility; and Method 3 (M3): directly precipitate BaSO4 without anion exchange resins with the precipitates being sent to the isotope facility. We found an excellent agreement of the δ34Ssulphate values among all the three methods. However, some differences were observed in the δ18Osulphate values (M1 versus M2:?1.5 ‰; M1 versus M3:?1.2 ‰) associated with possible O contamination before isotope measurement. Several approaches are recommended to improve the pretreatment procedures for δ18Osulphate analysis. 相似文献
12.
Peter Junghans Solvig Görs Martina Langhammer 《Isotopes in environmental and health studies》2013,49(6):561-572
ABSTRACTWe explored a novel doubly labelled water (DLW) method based on breath water (BW-DLW) in mice to determine whole body CO2 production and energy expenditure noninvasively. The BW-DLW method was compared to the DLW based on blood plasma. Mice (n?=?11, 43.5?±?4.6?g body mass (BM)) were administered orally a single bolus of doubly labelled water (1.2?g H218O kg BM?1 and 0.4?g 2H2O kg BM?1, 99 atom% (AP) 18O or 2H). To sample breath water, the mice were placed into a respiration vessel. The exhaled water vapour was condensed in a cold-trap. The isotope enrichments of breath water were compared with plasma samples. The 2H/1H and 18O/16O isotope ratios were measured by means of isotope ratio mass spectrometry. The CO2 production (RCO2) was calculated from the 2H and 18O enrichments in breath water and plasma over 5 days. The isotope enrichments of breath water vs. plasma were correlated (R2?=?0.89 for 2H and 0.95 for 18O) linearly. The RCO2 determined based on breath water and plasma was not different (113.2?±?12.7 vs. 111.4?±?11.0?mmol?d–1), respectively. In conclusion, the novel BW-DLW method is appropriate to obtain reliable estimates of RCO2 avoiding blood sampling. 相似文献
13.
Michael Thoma Jay Frentress Massimo Tagliavini 《Isotopes in environmental and health studies》2018,54(4):403-417
We used pore water samplers (PWS) to sample for isotope analysis (1) only water, (2) soil under laboratory conditions, and (3) soil in the field comparing the results with cryogenic extraction (CE). In (1) and (2), no significant differences between source and water extracted with PWS were detected with a mean absolute difference (MAD) always lower than 2?‰ for δ2H and 1?‰ for δ18O. In (2), CE water was more enriched than PWS-extracted water, with a MAD respect to source water of roughly 8?‰ for δ2H and 4?‰ for δ18O. In (3), PWS water was enriched relative to CE water by 3?‰ for δ2H and 0.9?‰ for δ18O. The latter result may be due to the distinct water portions sampled by the two methods. Large pores, easily sampled by PWS, likely retain recent, and enriched, summer precipitation while small pores, only sampled by CE, possibly retain isotopically depleted water from previous winter precipitation or irrigation inputs. Accuracy and precision were greater for PWS relative to CE. PWS is therefore suggested as viable tool to extract soil water for stable isotope analysis, particularly for soils used in this study (sandy and silty loams). 相似文献
14.
Leonard I. Wassenaar Liang-Feng Han Thomas Schiefer Gustav Kainz Luis Araguas-Araguas Pradeep K. Aggarwal 《Isotopes in environmental and health studies》2018,54(3):274-287
Tritium (3H) is an essential tracer of the Earth's water cycle; yet widespread adoption of tritium in hydrologic studies remains a challenge because of analytical barriers to quantification and detection of 3H by electrolytic pre-concentration. Here, we propose a simple tritium electrolytic enrichment system based on the use of solid polymer electrolyte membranes (PEMs) that can be used to enrich 3H in 250–3000?mL environmental water samples to a 10-mL final volume. The IAEA PEM-3H system reported here can produce high enrichment factors (>70-fold) and, importantly, removes some of the deterrents to conventional 3H enrichments methods, including the use of toxic electrolysis and neutralization chemicals, spike standards, a complex electrolysis apparatus that requires extensive cooling and temperature controls, and improves precision by eliminating the need for tracking recovery gravimetrics. Preliminary results with varying operating conditions show 3H enrichments to 70-fold and higher are feasible, spanning a wide range of tritium activities from 5 to 150 TU with a precision of ~4.5?%. Further work is needed to quantify inter-sample memory and to establish lower 3H detection limits. The IAEA PEM-3H system is open source, with 3-D CAD and design files made freely available for adoption and improvement by others. 相似文献
15.
Haiping Qi Tyler B. Coplen Lauren Tarbox Jennifer M. Lorenz Martha Scholl 《Isotopes in environmental and health studies》2014,50(4):442-447
A new secondary isotopic reference material has been prepared from Puerto Rico precipitation, which was filtered, homogenised, loaded into glass ampoules, sealed with a torch, autoclaved to eliminate biological activity, and calibrated by dual-inlet isotope-ratio mass spectrometry. This isotopic reference material, designated as USGS48, is intended to be one of two isotopic reference waters for daily normalisation of stable hydrogen (δ2H) and stable oxygen (δ18O) isotopic analysis of water with a mass spectrometer or a laser absorption spectrometer. The δ2H and δ18O values of this reference water are?2.0±0.4 and?2.224±0.012 ‰, respectively, relative to Vienna Standard Mean Ocean Water on scales normalised such that the δ2H and δ18O values of Standard Light Antarctic Precipitation reference water are?428 and?55.5 ‰, respectively. Each uncertainty is an estimated expanded uncertainty (U=2uc) about the reference value that provides an interval that has about a 95 % probability of encompassing the true value. This isotopic reference water is available by the case of 144 glass ampoules containing 5 mL of water in each ampoule. 相似文献
16.
Ravi Rangarajan 《Isotopes in environmental and health studies》2013,49(4):498-511
The GasBench II peripheral along with MAT 253 combination provides a more sensitive platform for the determination of water isotope ratios. Here, we examined the role of adsorbed moisture within the gas chromatography (GC) column of the GasBench II on measurement uncertainties. The uncertainty in 18O/16O ratio measurements is determined by several factors, including the presence of water in the GC. The contamination of GC with water originating from samples as water vapour over a longer timeframe is a critical factor in determining the reproducibility of 18O/16O ratios in water samples. The shift in isotope ratios observed in the experiment under dry and wet conditions correlates strongly with the retention time of analyte CO2, indicating the effect of accumulated moisture. Two possible methods to circumvent or minimise the effect of adsorbed water on isotope ratios are presented here. The proposed methodology includes either the regular baking of the GC column at a higher temperature (120 °C) after analysis of a batch of 32 sample entries or conducting the experiment at a low GC column temperature (22.5 °C). The effects of water contamination on long-term reproducibility of reference water, with and without baking protocol, have been described. 相似文献
17.
Dieter Rank Katharina Schott Silvia Weigand Armin Oblin 《Isotopes in environmental and health studies》2018,54(2):115-136
The Austrian network of isotopes in rivers comprises about 15 sampling locations and has been operated since 1976. The Danube isotope time series goes back to 1963. The isotopic composition of river water in Central Europe is mainly governed by the isotopic composition of precipitation in the catchment area; evaporation effects play only a minor role. Short-term and long-term isotope signals in precipitation are thus transmitted through the whole catchment. The influence of climatic changes has become observable in the long-term stable isotope time series of precipitation and surface waters. Environmental 3H values were around 8 TU in 2015, short-term 3H pulses up to about 80 TU in the rivers Danube and March were a consequence of releases from nuclear power plants. The complete isotope data series of this network will be included in the Global Network of Isotopes in Rivers database of the International Atomic Energy Agency (IAEA) in 2017. This article comprises a review of 50 years isotope monitoring on rivers and is also intended to provide base information on the (isotope-)hydrological conditions in Central Europe specifically for the end-users of these data, e.g. for modelling hydrological processes. Furthermore, this paper includes the 2006–2015 supplement adding to the Danube isotope set published earlier. 相似文献
18.
19.
Yuri V. Dublyansky Alexander B. Klimchouk Sergey V. Tokarev Gennady N. Amelichev Christoph Spötl 《Isotopes in environmental and health studies》2013,49(5):419-437
ABSTRACTKarst springs in the Main Range of the Crimean Mountains and the Crimean Piedmont show a restricted range of values (δ18O?=?–10.5 to –8.0 ‰, δ2H?=?–72 to –58 ‰), somewhat more negative than the weighted mean of meteoric precipitation. This suggests preferential recharge at higher elevations during winter months. Groundwater tapped by boreholes splits in three groups. A first group has isotopic properties similar to those of the springs. The second group shows significantly lower values (δ18O?=?–13.3 to –12.0 ‰, δ2H?=?–95 to –82 ‰), suggesting recharge during colder Pleistocene times. The third group has high isotope values (δ18O?=?–2.5 to +1.0 ‰, δ2H?=?–24 to –22 ‰); the data points are shifted to the right of the Local Meteoric Water Line, suggesting water–rock exchange processes in the aquifer. These boreholes are located in the Crimean Plains and discharge mineralized (ca. 25 g L?1) thermal (65°C) water from a depth of 1600–1800 m. Groundwater associated with mud volcanoes on the Kerch peninsula have distinct isotope characteristics (δ18O?=?–1.6 to +9.4 ‰, δ2H?=?–30 to –18 ‰). Restricted δ2H variability along with variable and high δ18O values suggest water–rock interactions at temperatures exceeding 95 °C. 相似文献
20.
Karsten Müller 《Isotopes in environmental and health studies》2014,50(2):277-284
The accurate ultra-trace analysis of six fluorobenzoic acids (FBAs) via isotope dilution gas chromatography mass spectrometry through their deuterated analogues is described. North Sea reservoir and ground water samples were spiked with six deuterated FBAs (dFBAs), enriched using solid-phase extraction (SPE) and analysed using GC/MS after derivatisation with BF 3· MeOH. All FBAs were enriched and determined simultaneously. SPE allowed a 250-fold enrichment of the acids if 100 mL of sample volume was used. The method enables the determination of FBAs down to the range of 8–37 ng L ?1 with recoveries between 66 % and 85 %. It uses low amounts of chemicals and is adaptable to larger and smaller sample volumes. 相似文献