首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Lee CG  Suzuki D  Esaka F  Magara M  Kimura T 《Talanta》2011,85(1):644-649
The fission track technique is a sensitive detection method for particles which contain radio-nuclides like 235U or 239Pu. However, when the sample is a mixture of plutonium and uranium, discrimination between uranium particles and plutonium particles is difficult using this technique. In this study, we developed a method for detecting plutonium particles in a sample mixture of plutonium and uranium particles using alpha track and fission track techniques. The specific radioactivity (Bq/g) for alpha decay of plutonium is several orders of magnitude higher than that of uranium, indicating that the formation of the alpha track due to alpha decay of uranium can be disregarded under suitable conditions. While alpha tracks in addition to fission tracks were detected in a plutonium particle, only fission tracks were detected in a uranium particle, thereby making the alpha tracks an indicator for detecting particles containing plutonium. In addition, it was confirmed that there is a linear relationship between the numbers of alpha tracks produced by plutonium particles made of plutonium certified standard material and the ion intensities of the various plutonium isotopes measured by thermo-ionization mass spectrometry. Using this correlation, the accuracy in isotope ratios, signal intensity and measurement errors is presumable from the number of alpha tracks prior to the isotope ratio measurements by thermal ionization mass spectrometry. It is expected that this method will become an effective tool for plutonium particle analysis. The particles used in this study had sizes between 0.3 and 2.0 μm.  相似文献   

2.
Esaka F  Magara M  Suzuki D  Miyamoto Y  Lee CG  Kimura T 《Talanta》2010,83(2):569-573
Information on plutonium isotope ratios in individual particles is of great importance for nuclear safeguards, nuclear forensics and so on. Although secondary ion mass spectrometry (SIMS) is successfully utilized for the analysis of individual uranium particles, the isobaric interference of americium-241 to plutonium-241 makes difficult to obtain accurate isotope ratios in individual plutonium particles. In the present work, an analytical technique by a combination of chemical separation and inductively coupled plasma mass spectrometry (ICP-MS) is developed and applied to isotope ratio analysis of individual sub-micrometer plutonium particles. The ICP-MS results for individual plutonium particles prepared from a standard reference material (NBL SRM-947) indicate that the use of a desolvation system for sample introduction improves the precision of isotope ratios. In addition, the accuracy of the 241Pu/239Pu isotope ratio is much improved, owing to the chemical separation of plutonium and americium. In conclusion, the performance of the proposed ICP-MS technique is sufficient for the analysis of individual plutonium particles.  相似文献   

3.
Summary The relative uncertainty on the isotope abundance ratio measurements of uranium and plutonium samples by means of thermionic mass spectrometry at the Central Bureau for Nuclear Measurements (CBNM) in Geel, Belgium, has decreased to a level of about 2 · 10–4.The improvement was mainly achieved through the preparation of synthetic isotope mixtures of uranium and plutonium, to a relative uncertainty of 0.01% (computed on a 2s basis) on the ratios of isotopes with major abundances. This allowed to determine some error sources more precisely, such as: — isotope fractionation, — non-linearity of the ion beam current measuring system.As a consequence CBNM is able to prepare certified uranium isotopic reference materials (U IRM's) for distribution, with a relative uncertainty of 0.07% (computed on a 2s basis) on the235U isotope abundance and to provide reference values on samples for the (European) Interlaboratory Measurement Evaluation Programmes (REIMEP).
Nuklearanalytische Anwendung der Thermionen-Massenspektrometrie
  相似文献   

4.
Product quality control within the nuclear fuel cycle is a subject of special concern in Russia nowadays. Earlier, mass spectrometers of foreign production were commonly used for elemental and isotope analysis of samples. Currently, a series of domestic mass spectrometers MTI-350 has been developed and their production has been organized in Russia. The series comprises an automated MTI-350G mass spectrometer for the isotope analysis of uranium hexafluoride; thermal ionization MTI-350T mass spectrometer for the isotope analysis of uranium, plutonium, and mixed oxide (MOX) fuels; an MTI-350GS mass spectrometer for controlling the production of uranium hexafluoride; and an MTI-350GP mass spectrometer for the determination of the impurity concentration in uranium hexafluoride. The article considers operation principles, analytical characteristics, and the advantages of the above mass spectrometers.  相似文献   

5.
Summary The recent discovery of the migration of plutonium in groundwater away from underground nuclear tests at the Nevada Test Site has spawned considerable interest in the mechanisms by which plutonium may be released to the environment by a nuclear explosion. A suite of solid debris samples was collected during drilling through an expended test cavity and the overlying collapse chimney. Uranium and plutonium were analyzed for isotope ratios and concentrations using high precision magnetic sector inductively coupled mass spectrometry. The data unequivocally shows that plutonium may be dispersed throughout the cavity and chimney environment at the time of the detonation. The 239Pu/240Pu ratios are also fractionated relative to initial plutonium isotope ratio for the test device. Fractionation is the result of the volatilization of uranium and production of 239Pu by the reaction 238U(n,γ). We conclude that for the test under consideration plutonium was deposited outside of the confines of the cavity by dynamic processes in early-time and it is this plutonium that is most likely transferred to the groundwater regime.  相似文献   

6.
This report assesses the utility of lanthanum-halide detectors for isotope identification and total mass measurements for uranium and plutonium isotopes. Comparisons to similar measurements with NaI detectors are made.  相似文献   

7.
萃取色层分离同位素稀释ICP-MS测定空气中费克 量钚   总被引:6,自引:0,他引:6  
ICP-MS测定环境样品中超痕量^2^3^9Pu时,^2^3^8UH^+会对m/z239的测量带来干扰。测得UH^+的产生几率为4.6×10^-^5,通过三正辛胺色层分离后,对铀的去除率为10^4,可以有效地去除^2^3^8UH^+离子峰对^2^3^9Pu测定的干扰。钚的回收率为75%。同位素稀释法对^2^3^9Pu的检出限为4.5×10^-^1^5g/mL,方法的定量测定限为16×10^-^1^5g/mL。用所建立的方法测得我国某地区空气中^2^3^9Pu的浓度为4.8×10^-^1^7g/m^3。  相似文献   

8.
A stable solid spike for the measurement of uranium and plutonium content in nitric acid solutions of spent nuclear fuel by isotope dilution mass spectrometry has been prepared at the European Commission Institute for Reference Materials and Measurements in Belgium. The spike contains about 50 mg of uranium with a 19.838% (235)U enrichment and 2 mg of plutonium with a 97.766% (239)Pu abundance in each individual ampoule. The dried materials were covered with a thin film of cellulose acetate butyrate as a protective organic stabilizer to resist shocks encountered during transportation and to eliminate flaking-off during long-term storage. It was found that the cellulose acetate butyrate has good characteristics, maintaining a thin film for a long time, but readily dissolving on heating with nitric acid solution. The solid spike containing cellulose acetate butyrate was certified as a reference material with certified quantities: (235)U and (239)Pu amounts and uranium and plutonium amount ratios, and was validated by analyzing spent fuel dissolver solutions of the Tokai reprocessing plant in Japan. This paper describes the preparation, certification and validation of the solid spike coated with a cellulose derivative.  相似文献   

9.
A ratio derivative spectrophotometric method has been developed for the simultaneous determination of uranium and plutonium at mg levels in 1M HNO3 medium. In this method the overlapping spectra of uranium and plutonium are well resolved by making use of the first derivative of the ratios of their direct absorption spectra. The derivative ratio absorbances of uranium and plutonium are measured at 411.2 and 473.8 nm, respectively for their quantification. The method is simple, fast and does not require separation of uranium and plutonium. Another salient feature of the method is that it does not lead to generation of analytical waste thereby minimising the efforts required for the recovery of plutonium. Uranium in the conc. range of 10–25 mg/g and plutonium in the conc. range of 0.5 to 2 mg/g (U/Pu ratio varying from about 10 to 25) were determined in the same aliquot with a precision and accuracy of about 0.5% and 1%, respectively.  相似文献   

10.
As a rule the analysis of nuclear oxide fuel includes the determination of uranium, plutonium, their isotopic composition, cation impurities, carbon, nitrogen, chlorine, fluorine, oxygen coefficient. In this paper we discuss different methods for the a analysis of unirradiated uranium and plutonium oxide fuelds used in the laboratories of the Analytical Chemistry Department: coulometry, emission analysis, chromatography, X-ray analysis. Much consideration is being given to the analysis of uranium and plutonium oxide samples and uranium-plutonium mixed fuels irradiated in the BOR-60 using mass-spectrometric (isotope dilution method) and radiometric techniques. The results of uranium and plutonium determination by these methods are compared. The main analytical characteristics of the methods are given.  相似文献   

11.
The plutonium determination by alpha-particle spectrometry with semiconductor detectors in the presence of uranium has been described. It has been found that plutonium as well as uranium can be electrodeposited quantitatively on nickel or stainless steel discs from solutions in isopropanol. The time of deposition does not exceed 35–40 min. The determination of plutonium is possible within the uranium to plutonium weight ratio of 4000 with the accuracy better than 2%.  相似文献   

12.
Precise long-term measurements of uranium and thorium isotope ratios was carried out in 1 μg/L solutions using a quadrupole inductively coupled plasma mass spectrometer (ICP-QMS). The isotopic ratios of uranium (235U/ 238U = 1, 0.02 and 0.00725) were determined using a cross-flow nebulizer (CFN, at solution uptake rate of 1 mL/min) and a low-flow microconcentric nebulizer (MCN, at solution uptake rate of 0.2 mL/min) over 20 h. For 1 μg/L uranium solution (235U/238U = 1) relative external standard deviations (RESDs) of 0.05% and 0.044% using CFN and MCN, respectively, can be achieved. Additional short term isotope ratio measurements using a direct injection high-efficiency nebulizer (DIHEN) of 1 μg/L uranium solution (235U/238U = 1) at a solution uptake rate of 0.1 mL/min yielded an RSD of 0.06–0.08%. The sensitivity of solution introduction by DIHEN for uranium, thorium and plutonium (145 MHz/ppm, 150 MHz/ppm and 177 MHz/ppm, respectively) increased significantly compared to CFN and MCN and the solution uptake rate can be reduced to 1 μL/ min in DIHEN-ICP-MS. Isotope ratio measurements at an ultralow concentration level (e.g. determination of 240Pu/ 239Pu isotope ratio in a 10 ng/L Pu waste solution) were carried out for the characterization of radioactive waste and environmental samples.  相似文献   

13.
Mixed-actinide microstandard particles have been produced for calibration and performance testing of isotope-ratio mass spectrometers and ion and electron microprobe instruments. The spherical micrometer-size particles consist of an aluminosilicate matrix loaded with 2.2% by weight of isotopically certified uranium and 0.11% by weight of isotopically certified plutonium. The uranium and plutonium isotopic compositions have been verified by both thermal ionization mass spectrometry and secondary ionization mass spectrometry (SIMS). The elemental composition of the microspheres has been determined by both electron microprobe and SIMS analysis.  相似文献   

14.
A new method for the determination of (237)Np and Pu isotopes in large soil samples has been developed that provides enhanced uranium removal to facilitate assay by inductively coupled plasma mass spectrometry (ICP-MS). This method allows rapid preconcentration and separation of plutonium and neptunium in large soil samples for the measurement of (237)Np and Pu isotopes by ICP-MS. (238)U can interfere with (239)Pu measurement by ICP-MS as (238)UH(+) mass overlap and (237)Np via (238)U peak tailing. The method provides enhanced removal of uranium by separating Pu and Np initially on TEVA Resin, then transferring Pu to DGA resin for additional purification. The decontamination factor for removal of uranium from plutonium for this method is greater than 1×10(6). Alpha spectrometry can also be applied so that the shorter-lived (238)Pu isotope can be measured successfully. (239) Pu, (242)Pu and (237)Np were measured by ICP-MS, while (236)Pu and (238)Pu were measured by alpha spectrometry.  相似文献   

15.
A derivative spectrophotometric method has been developed for the simultaneous determination of uranium and plutonium at trace levels in various process streams in 3M HNO3 medium using Arsenazo III. The method was developed with the objective of measuring both uranium and plutonium in the same aliquot in fairly high burn-up fuels. The first derivative absorbances of the uranium and plutonium Arsenazo III complexes at 632 nm and 606.5 nm, respectively, were used for their quantification. Mixed aliquots of uranium (20–28 μg/ml) and plutonium (0.5–1.5 μg/ml) with U/Pu ratio varying from 25 to 40 were analysed using this technique. A relative error of about 5% was obtained for uranium and plutonium. The method is simple, fast and does not require separation of uranium and plutonium. The effect of presence of many fission products, corrosion products and complexing anions on determination of uranium and plutonium was also studied.  相似文献   

16.
Electrochemically modulated separations (EMS) are shown to be a rapid and selective means of extracting and concentrating Pu from complex solutions prior to isotopic analysis by inductively coupled plasma mass spectrometry (ICP‐MS). This separation is performed in a flow injection mode, on‐line with the ICP‐MS. A three‐electrode, flow‐by electrochemical cell is used to accumulate Pu at an anodized glassy carbon electrode by redox conversion of Pu(III) to Pu (IV&VI). The entire process takes place in 2% (v/v) (0.46 M) HNO3. No redox chemicals or acid concentration changes are required. Plutonium accumulation and release is redox dependent and controlled by the applied cell potential. Large transient volumetric concentration enhancements can be achieved. Based on more negative U(IV) potentials relative to Pu(IV), separation of Pu from uranium is efficient, thereby eliminating uranium hydride interferences. EMS‐ICP‐MS isotope ratio measurement performance will be presented for femtogram to attogram level plutonium isotope injections.  相似文献   

17.
Isotopic dilution mass spectrometry has been applied to assess the plutonium concentration in samples such as those obtained from the dissolution of irradiated uranium fuels in a reprocessing plant. Prior to the analysis, plutonium is taken through a redox cycle and is separated from uranium and fission products by extraction into TTA-xylene. The extraction procedure, the standardization of the spike solution and the mass assay of the plutonium are described; typical results under plant conditions are given. The overall precision of a single measurement of the plutonium concentration is 0.6%, expressed as relative standard deviation, including the plant sampling error, dilution error and analytical error.  相似文献   

18.
《Analytical letters》2012,45(8-9):563-574
Abstract

The method uses basic anion resin to adsorb plutonium and uranium from 7–8 M HNO3 solutions containing dissolved spent reactor fuels. After equilibrating the resin with the solution, a single bead is used to determine the isotopic composition of plutonium and uranium on sample sizes as small as 10?9 to 10?10 g of each element per bead. Isotopic measurements are essentially free of isobaric interferences and fission product contamination in the mass spectrometer is eliminated. A very small aliquot of dissolver solution containing 10?6 g of U and 10?8 g of Pu is sufficient sample for chemically preparing several resin beads. A single prepared bead is loaded onto a rhenium filament and analyzed in a two-stage mass spectrometer using pulse counting for ion detection to obtain the high sensitivity required. Total quantity of the elements, in addition to isotopic abundances, can be determined by isotope dilution. Other areas where the method may be useful are: in plutonium production, isotope separations, and for trace detection of contamination on reactor parts.  相似文献   

19.
Precise long-term measurements of uranium and thorium isotope ratios was carried out in 1 μg/L solutions using a quadrupole inductively coupled plasma mass spectrometer (ICP-QMS). The isotopic ratios of uranium (235U/ 238U = 1, 0.02 and 0.00725) were determined using a cross-flow nebulizer (CFN, at solution uptake rate of 1 mL/min) and a low-flow microconcentric nebulizer (MCN, at solution uptake rate of 0.2 mL/min) over 20 h. For 1 μg/L uranium solution (235U/238U = 1) relative external standard deviations (RESDs) of 0.05% and 0.044% using CFN and MCN, respectively, can be achieved. Additional short term isotope ratio measurements using a direct injection high-efficiency nebulizer (DIHEN) of 1 μg/L uranium solution (235U/238U = 1) at a solution uptake rate of 0.1 mL/min yielded an RSD of 0.06–0.08%. The sensitivity of solution introduction by DIHEN for uranium, thorium and plutonium (145 MHz/ppm, 150 MHz/ppm and 177 MHz/ppm, respectively) increased significantly compared to CFN and MCN and the solution uptake rate can be reduced to 1 μL/ min in DIHEN-ICP-MS. Isotope ratio measurements at an ultralow concentration level (e.g. determination of 240Pu/ 239Pu isotope ratio in a 10 ng/L Pu waste solution) were carried out for the characterization of radioactive waste and environmental samples. Received: 1 December 1998 / Revised: 25 January 1999 / Accepted: 31 January 1999  相似文献   

20.
Studies on the individual potentiometric determination of uranium and plutonium in a single aliquot have been initiated recently in our laboratory. It was required to adapt the reported procedures (for the precise determination of uranium and plutonium individually when present together in a sample) at various stages to make them suitable for the successive application of the procedures to the same aliquot. Two alternative schemes are proposed in the present work. In the first, plutonium is determined by HClO4 oxidation followed by the determination of total uranium and plutonium by Zn(Hg) reduction. In the second, plutonium is determined by AgO oxidation following the determination of total uranium and plutonium by Zn(Hg) reduction. Amount of uranium is computed in both cases from the difference of two determinations. Precision for the assay of plutonium and uranium was found to be ±0.25% and ±0.35%, respectively, at milligram levels.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号