共查询到20条相似文献,搜索用时 15 毫秒
1.
Reversed-phase liquid chromatographic separation of enantiomers on polysaccharide type chiral stationary phases 总被引:5,自引:0,他引:5
The direct chiral separation by chiral stationary phases (CSPs) is one of the most important techniques to analyze enantiomeric purity as well as to get enantiomerically pure material quickly. Among various types of CSPs, polysaccharide type CSPs are well known by their versatility and durability. They are not only effective under normal-phase conditions, but also under reversed-phase conditions. In order to get a good separation under the reversed-phase conditions, it is the key to choose an appropriate mobile phase. For example, a simple mixture of water/acetonitrile or water/methanol are sufficient for a neutral analyte, while it is necessary to use an acidic solution instead of water for an acidic analyte and a solution of a chaotropic salt (or a basic solution) for a basic analyte, respectively. The paper also presents lists of more than 350 separation examples that include 22 validated methods for drug analyses from serum, plasma, or urine samples on polysaccharide type CSPs under reversed-phase conditions. 相似文献
2.
3.
High-performance liquid chromatographic separation of the enantiomers of organophosphorus pesticides on polysaccharide chiral stationary phases. 总被引:3,自引:0,他引:3
High-performance liquid chromatographic separation of the individual enantiomers of 12 organophosphorus pesticides (OPs) was obtained on polysaccharide enantioselective HPLC columns using alkane-alcohol mobile phase. The OP pesticides were crotoxyphos, dialifor, fonofos, fenamiphos, fensulfothion, isofenphos, malathion, methamidophos, profenofos, crufomate, prothiophos and trichloronate. The enantiomers of fenamiphos, fensulfothion, profenofos and crufomate were separated on CHIRALPAK AD; the enantiomers of fenamiphos were also separated on CHIRALPAK AS; the enantiomers of methamidophos, crufomate and trichloronate were separated on CHIRALCEL OD; the enantiomers of crotoxyphos, dialifor, fonofos, malathion, prothiophos and trichloronate were separated on CHIRALCEL OJ; and the enantiomers of isofenphos were separated on CHIRALCEL OG. Baseline or partial separation of the enantiomers of six of these OP pesticides was obtained on CHIRALCEL OJ. In continued method development, the separation of the enantiomers of the 12 OPs was investigated more extensively on CHIRALCEL OJ to determine whether the mobile phase composition, flow-rate and column temperature could be optimized to yield at least partial separation of the enantiomers. Chromatographic conditions were found that gave either baseline or near baseline separations of the enantiomers of the 12 OPs on the CHIRALCEL OJ column. 相似文献
4.
Many chiral pesticides exhibit enantioselectivity in biotransformation and ecotoxicity in the environment. A significant class of chiral pesticides is imidazolinone herbicides, of which enantioselectivity has not been well studied. Development of efficient chiral separation methods is the first step for allowing characterization of enantioselectivity in environmental processes. In this study, we attempted to resolve enantiomers of imidazolinone herbicides using reversed-phase and normal-phase high-performance liquid chromatography with polysaccharide-type chiral columns. Enantiomers of imazethapyr, imazaquin, and imazamox were separated on a Chiralcel OD-R column using 50mM phosphate buffer-acetonitrile as mobile phase. Enantiomers of imazapyr, imazapic, imazethapyr, imazamox and imazaquin were resolved on a Chiralcel OJ column using n-hexane (0.1% trifluoroacetic acid)-alcohol as mobile phase. The enantiomers of five methyl derivatives of imidazolinone herbicides were also resolved on the Chiralcel OJ column. The Deltak' values revealed a structure-enantioselectivity relationship for the separation behaviors of the enantiomers on the OJ column. The described method was successfully applied for chiral analysis of two imidazolinone herbicides (imazapyr and imazaquin) in spiked soil samples. 相似文献
5.
The column technologies play a crucial role in the development of new methods and technologies for the separation of biological samples containing hundreds to thousands compounds. This review focuses on the development of monolithic technology in micro-column formats for biological analysis, especially in capillary liquid chromatography, capillary electrochromatography and microfluidic devices in the past 5 years (2002-2007) since our last review in 2002 on monoliths for HPLC and CEC. The fabrication and functionalization of monoliths were summarized and discussed, with the aim of presenting how monolithic technology has been playing as an attractive tool for improving the power of existing chromatographic separation processes. This review consists of two parts: (i) the recent development in fabrication of monolithic stationary phases from direct synthesis to post-functionalization of the polymer- and silica-based monoliths tailoring the physical/chemical properties of porous monoliths; (ii) the application of monolithic stationary phases for one- and multi-dimensional capillary liquid chromatography, fast separation in capillary electro-driven chromatography, and microfluidic devices. 相似文献
6.
Molecularly imprinted polymers: towards highly selective stationary phases in liquid chromatography and capillary electrophoresis 总被引:3,自引:0,他引:3
Molecularly imprinted polymers (MIPs) are synthetic polymers with a predetermined selectivity for a given analyte, or group of structurally related compounds, that make them ideal materials to be used in separation processes. In this sense, it is not surprising that the first applications of MIPs were as tailor-made chiral stationary phases in liquid chromatography. However, peak broadening and tailing, especially of the more retained enantiomers, were observed. Accordingly, this paper gives an overview of the attempts carried out during the recent years to improve the chromatographic performance of MIPs in liquid chromatography and capillary electrophoresis as well as the more recent applications. We conclude that MIPs are very promising materials to be used as selective stationary phases in chromatography although further developments are necessary in order to fully exploit their potential. 相似文献
7.
A new type of bonded stationary phase for liquid chromatography, with the properties of immobilized artificial membranes, has been synthesized. Alkyl-phosphate adsorbents were obtained by modification of aminopropyl silica gel. The structures of the synthesized materials were confirmed by use of instrumental techniques--elemental analysis, infrared spectroscopy (FTIR), and (13)C and (29)Si CP/MAS NMR. Analysis revealed that the adsorbents mimic the phospholipids present in natural cell membranes. The new synthesized alkyl-phosphate stationary phases may be used for liquid chromatographic separation of biologically active compounds of different polarity. 相似文献
8.
A simple and inexpensive equipment for the optical resolution of enantiomers (and separation of diastereomers) on triacetylcellulose in ethanol at elevated pressure is described. It involves a closed circuit of solvent (pump—column—detector—pump) allowing a continuous chromatography up to 16 cycles without stopping the flow or handling fractions.This useful and versatile method permitting also the determination of enantiomeric purities is illustrated by several examples of centro-, axial- and planarchiral arenes and metallocenes.Herrn Prof. Dr.U. Schmidt, Stuttgart, zum 60. Geburtstag gewidmet. 相似文献
9.
A C Mehta 《Journal of chromatography. A》1988,426(1):1-13
The development of chiral stationary phases for HPLC has resulted in renewed interest in methods for the separation of drug enantiomers. This paper provides a brief overview of some of the more recent approaches to the direct resolution of drug enantiomers by HPLC with particular emphasis on their quantification in biological fluids. 相似文献
10.
Molecular species of phosphatidylcholine, phosphatidylethanolamine and phosphatadic acid were resolved by isocratic reversed phase high performance liquid chromatography (HPLC) using mobile phases of methanol-isopropanol containing para-toluenesulfonic acid (p-tsa). Separation by both non-polar fatty acid chain length and by polar head group functionality was achieved concurrently upon a commercially available octadecylsilane (C18) column endcapped with trimethylsilane (C1) groups. Using a mobile phase of 97.5:2.5 methanol:isopropanol with 7OmMpara-toluenesulfonic acid (p-tsa) at a pH of approximately 1, twelve phospholipid species comprised of four tail group classes (dilauroyl-,dimyristoyl-, dipamitoyl- and distearoyl-) and three head group speciations (phosphatidylcholine, phosphatidylethanolamine and phosphatadic acid) were separated. The column was then exposed to the acidic mobile phase for 48 hours continuously during which the bound phase underwent severe acid-induced hydrolysis, after which the separation of the twelve analytes resulted in the separation of the phospholipid species by non-polar tail group alone. The experimental results are discussed in terms of potential separation mechanisms including dependency of the separation on adsorption of the counter ion into the stationary phase, residual acidic silanol group interactions, and potential interactions of the surface active phospholipids with C1 groups. 相似文献
11.
Nadalini G Dondi F Massi A Dondoni A Zhang T Cavazzini A 《Journal of chromatography. A》2006,1126(1-2):357-364
The chromatographic behavior of a set of racemic dihydropyrimidines (DHPMs) has been evaluated on two polysaccharide-derived chiral stationary phases under normal phase conditions. One of these is coated, the other chemically immobilized. The outstanding solvent compatibility of the immobilized chiral stationary phase (CSP) permits the use of solvents such as ethyl acetate (EtOAc) that are unsuitable for coated supports, for which traditional 2-propanol:hexanes mixtures have been employed. Drastic changes in the chromatographic retention and resolution of DHPMs and, in general, in the separation performances have been observed for the two systems. From a practical point of view, EtOAc has been proven to be a better choice for the separation of this important class of compounds. By comparing molecules different in specific positions of their scaffolds, hypotheses concerning the role of individual chemical groups on retention and selectivity have been done. These effects have been quantified, in some cases, in terms of standard Gibbs energy variations. Even if no chromatographic measurements have been made under nonlinear conditions, clear indications of the potential use of immobilized chiral adsorptive media operated with EtOAc:hexanes mixtures for preparative separations of DHPMs have been evidenced. 相似文献
12.
A variety of racemic compounds were resolved using reversed-phase thin-layer chromatography (TLC) with mobile phases containing highly concentration solutions of beta-cyclodextrin (beta-CD). These include the drugs labetalol and mephenytoin, metallocenes, crown ethers, methyl-p-toluenesulfinate, nornicotine derivaties and several dansyl and beta-naphthylamide substituted amino acids. It was possible to resolve some racemates that could not be separated on beta-CD bonded phase liquid chromatography (LC) columns with this technique. Likewise there were some compounds that could be resolved with the LC approach that failed to separate with the present TLC method. In cases of racemates that could be resolved by either approach, it was found that the retention order was exactly opposite for the two methods. Enantiomeric resolution is highly dependent on mobile phase composition. In particular, the type and amount of organic modifier as well as the concentration of beta-CD affect the observed resolution. Possible reasons for the chromatographic behavior are discussed. Several diastereoisomeric compounds were separated as well, including steroid epimers and pharmaceutical compounds. 相似文献
13.
14.
Polysaccharide-based chiral stationary phases for high-performance liquid chromatographic enantioseparation 总被引:17,自引:0,他引:17
Yashima E 《Journal of chromatography. A》2001,906(1-2):105-125
Recent developments of polysaccharide-based chiral stationary phases (CSPs) for the direct separation of enantiomers in high-performance liquid chromatography (HPLC) are mainly reviewed together with the results on mechanistic studies by means of chromatography, NMR and mass spectroscopies, and computational methods. Miscellaneous applications of polysaccharide derivatives to the newly developed, chiral dynamic high-performance liquid chromatography (DHPLC) for obtaining a nonracemic compound are also described. 相似文献
15.
<正>A method of high performance liquid chromatographic separation of clausenamide enantiomers with chiral-AGP(α_1-acid glycoprotein) stationary phases has been established.The absolute configurations of(-)clausenamide and(+)clausenamide are 3S, 4R,5R,6S and 3R,4S,5S,6R,respectively.The present method has been used to analyze the(-)clausenamide and(+)clausenamide and its analogues such as the major metabolite and synthetic derivatives of clausenamide. 相似文献
16.
Xu M Brahmachary E Janco M Ling FH Svec F Fréchet JM 《Journal of chromatography. A》2001,928(1):25-40
Uniformly sized macroporous polymer beads, which can be used as chiral stationary phase (CSP), have been prepared by the staged templated suspension polymerization process using chiral monomer as one of the copolymerization components. This approach enables the preparation of CSPs for which properties such as pore size, pore volume, surface area, chemistry, and chiral ligands can be tuned over a broad range. Several types of well-defined chiral monomers were prepared and allowed to assess synergistic effect of multiple selectors attached to a branched linker as well as the effect of the length and chemistry of the linker. Microscale batch screening was used for simple and rapid evaluation of selectivity. The most promising candidate CSPs were prepared on a larger scale and packed into HPLC columns. Their performance was demonstrated on the separation of racemic N-(3,5-dinitrobenzoyl)-alpha-amino acid alkylamides. The highest separation factors alpha of up to 27 were observed for CSPs prepared from monomers containing the branched spacer. These highly selective CSPs also enabled the separation of larger amounts of the target racemates upon column overload conditions. 相似文献
17.
18.
Synthetic materials that can specifically recognize proteins will find wide application in many fields.In this report,bovine serum albumin was chosen as the template protein.Acrylamide and N,N’-methylenebisacrylamide were employed as the functional and cross-linker monomers,respectively.Molecularly imprinted macroporous monolithic materials that can preferentially bind the template protein in an aqueous environment were prepared by combination of molecular imprinting technique and freezing/thawing preparation method.The resulted imprinted macroporous monolithic columns were evaluated by utilizing as stationary phase in high performance liquid chromatography and solid-phase extraction materials.The experimental results indicated that the imprinted macroporous monolithic column exhibited good recognition for template protein,as compared with the control protein(hemoglobin),whereas the non-imprinted polymer(prepared under the same conditions except without addition template protein) had no selective properties. 相似文献
19.
To improve the therapeutic potential of anti-HIV nucleoside analogues (d4T, AZT, 3TC and ddl), the delivery of the corresponding monophosphate from neutral, membrane-permeable prodrugs has been realised by the synthesis of lipophilic phosphoramidate triester prodrugs, such as the simple phenyl-L-alaninephosphate derivatives. However, the present non-stereoselective synthesis results in a mixture of 1:1 diastereomers, which differ from the configuration of the phosphorus atom asymmetric center. Since each diastereomer may have different biological activity and pharmacokinetic profile, analytical methods have to be developed for their separation. This work aims at showing the ability of a polysaccharide-type chiral stationary phase to resolve such diastereomers in reversed-phase high-performance liquid chromatography. The influence of operating parameters has been studied to optimise the separation; a thermodynamic approach has also been investigated to gain an insight in the retention mechanism of the prodrugs. Preliminary validation study (linearity, accuracy, repeatability) has yielded good results; in addition, the feasibility of HPLC-electrospray-mass spectrometry (HPLC-ESI-MS) coupling has been demonstrated and it is expected that this will lead to lower detection limits. 相似文献
20.
Rahul S. Pawar Erich Grundel Eugene Mazzola Kevin D. White Alexander J. Krynitsky Jeanne I. Rader 《Journal of separation science》2010,33(2):200-205
Enantioseparation of the pyrrolizidine alkaloid isomers intermedine and lycopsamine, isolated from Symphytum uplandicum, is discussed. The separatory power of two immobilized carbohydrate‐based chiral HPLC columns, Chiralpak IA and IC, in different chromatographic conditions is compared. The study demonstrated the importance of solvent and column selection while developing such chiral HPLC separation methods. The baseline HPLC separation of the two alkaloid isomers in preparatory scale is reported for the first time. The optimized separations were achieved on a Chiralpak IA column with mobile phases of ACN/methanol (80:20) and methanol/methyl‐t‐butyl ether (90:10), both containing 0.1% diethylamine. 相似文献