首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
We developed and validated an on-line reverse-phase two-dimensional LC/MS/MS (2D-LC/MS/MS) system for simultaneous determination of the levels of prostaglandin (PG) E(2) as well as PGF(2alpha) and its metabolite 13,14-dihydro-15-keto PGF(2alpha) (F(2alpha)-M) in human plasma. Analytes were extracted by a three-step solid-phase extraction. Samples were then analyzed by on-line 2D-LC/MS/MS with electrospray ionization in negative mode. The 2D-LC system is composed of two reverse-phase analytical columns with a trapping column linking the two analytical columns. While an acidic buffer was used for both separation dimensions, differing organic solvents were employed for each dimension: methanol for the first and acetonitrile for the second to increase resolving power. The 2D-LC/MS/MS method was highly selective and sensitive with a significantly lower limit of quantitation (0.5 pg/mL for PGE(2) and 2.5 pg/mL for PGF(2alpha) and F(2alpha)-M, respectively). Linearity of the 2D-LC/MS/MS system was demonstrated for the calibration ranges of 0.5-50 pg/mL for PGE(2) and 2.5-500 pg/mL for PGF(2alpha) and F(2alpha)-M, respectively. Acceptable precision and accuracy were obtained throughout the calibration curve ranges. This highly selective and sensitive method was successfully utilized to determine the endogenous levels of PGE(2), PGF(2alpha), and F(2alpha)-M in plasma samples from six (four male and two female) normal volunteers. The mean concentrations for each analyte were 0.755 pg/mL for PGE(2), 5.70 pg/mL for PGF(2alpha) and 9.48 pg/mL for F(2alpha)-M.  相似文献   

2.
In a previous study utilizing benzophenone-based topological probes to study conformationally dependent changes in mouse muscle nicotinic acetylcholine receptor (nAChR) topology, electrospray ionization tandem mass spectrometric (ESI-MS/MS) analysis led to a consistent -2.0 Da mass deviation from expected values. In the present study a synthetic peptide, corresponding to nAChR alpha1 subunit residues 130-139, was photolabeled. MS/MS analysis of this peptide using an ion trap confirmed the previously observed mass deviation, associated only with fragment ions that contain the incorporated benzophenone moiety. Analysis of peak profiles for the photolabeled ions does not indicate the typical 'peak fronting' that produces a mass shift when labile ions are prematurely ejected from the ion trap. Rather, hydrogen/deuterium (H/D) exchange experiments support the hypothesis that a chemical rearrangement involving phenyl migration and ketone formation has formed an unexpected oxidized peptide, with molecular mass 2 Da less than that expected, that is isolated for collision-induced dissociation in the ion trap together with the predicted precursor due to the broad ion isolation window specified.  相似文献   

3.
To investigate the possibility of structural assignment based on negative-ion tandem multistage (MSn) mass spectral matching, four isomers of 2-aminopyridine (PA)-derivatized monosialylated oligosaccharides (i.e., complex-type N-glycans with an alpha2-3- or alpha2-6-linked sialic acid on alpha1-6 or alpha1-3 antennae) were analyzed using high-performance liquid chromatography/electrospray ion trap time-of-flight mass spectrometry (HPLC/ESI-IT-TOFMS). The negative ion [M-2H]2- is observed predominantly in the MS1 spectra without the loss of a sialic acid. The MS2 spectra derived from it are sufficiently reproducible that MS2 spectral matching based on correlation coefficients can be applied to the assignment of these isomers. The isomers containing a sialic acid on alpha1-6 or alpha1-3 antennae can be distinguished by MS2 spectral matching, but the alpha2-3 and alpha2-6 linkage types of sialic acid cannot be distinguished by their MS2 spectra. However, MS3 spectra derived from fragment ions containing a sialic acid (i.e., C4- and D-type ions) clearly differentiate the alpha2-3 and alpha2-6 linkage types of sialic acid in their MS3 spectral patterns. This difference might be rationalized in terms of a proton transfer from the reducing-end mannose to the negatively charged sialic acid. These two moieties are very close in the structural conformations of the precursor C4-type fragment ions of alpha2-6 linkage type, as predicted by molecular mechanics calculations. Thus, negative-ion MSn (n = 2, 3) spectral matching was demonstrated to be useful for the structural assignment of these four monosialylated PA N-glycan isomers.  相似文献   

4.
To investigate the possibility of structural assignment based on negative-ion multistage tandem mass (MS(n)) spectral matching, four isomers of disialylated biantennary N-glycans (alpha2-6 and/or alpha2-3 linked sialic acid on alpha1-6 and alpha1-3 antennae) derivatized with 2-aminopyridine (PA) were analyzed by employing high-performance liquid chromatography/electrospray ionization linear ion trap time-of-flight mass spectrometry (HPLC/ESI-LIT-TOFMS), which uses helium gas for ion trapping and collision-induced dissociation (CID). It is shown that the MS(2) spectra derived from each precursor ion [M-2H](2-) are reproducible and useful for distinguishing the four isomers. Thus, they can be assigned by negative-ion MS(2) spectral matching based on correlation coefficients. In addition, MS(3) spectra derived from D-type fragment ions clearly differentiate the alpha2-3- or alpha2-6-linked sialic acid on the alpha1-6 antenna due to their characteristic spectral patterns. The C(4)-type fragment ions, which are produced from both the alpha1-6 and alpha1-3 antennae, show the characteristic MS(3) spectra reflecting alpha2-3- or alpha2-6- linkage type or a mixture of both types. Thus, the differentiation and assignment of these disialylated biantennary N-glycan isomers can also be supported with the MS(3) spectra of C(4)- and D-type ions.  相似文献   

5.
High-resolution Sustained off resonance irradiation (SORI) CID was employed to distinguish four pairs of isomeric diglycosyl flavonoids in the negative mode using the electrospray ionization Fourier transform ion cyclotron resonance mass spectrometry (ESI FTICR MS). All of these isomers can be distinguished via MS/MS data. For these diglycosyl flavones and flavanones, the deprotonated alpha1-->6 linkage diglycosyl flavonoids produce fewer fragments than the alpha1-->2 linkage type compounds and the Retro-Diels-Alder (RDA) reaction in MS/MS only takes place when the aglycone is a flavanone and glycosylated with an alpha1-->2 intersaccharide linkage disaccharide. The deprotonation sites after collisional activation are discussed according to the high mass accuracy and high-resolution data of tandem spectrometry. Some of these high-resolution SORI CID product ions from alpha1-->2 linkage diglycosyl flavonoids involve multibond cleavages; the possible mechanism is discussed based on the computer modeling using Gaussian 03 program package at the B3LYP/6-31G level of theory. Unambiguous elementary composition data provides fragmentation information that has not been reported previously.  相似文献   

6.
A sensitive liquid chromatography-electrospray ionization-tandem mass spectrometric (LC-ESI-MS/MS) method for the determination of the rat brain 5alpha-androstane-3alpha,17beta-diol (3alpha,5alpha-Adiol) has been developed and validated. The brain extract was purified using solid-phase extraction cartridges, derivatized with isonicotinoyl azide, and subjected to LC-MS/MS. The method was accurate and reproducible, and the limit of quantitation was 0.1 ng/g tissue when a 100-mg tissue sample was used. The change in the brain 3alpha,5alpha-Adiol level by immobilization stress was also analyzed using the developed method.  相似文献   

7.
Oligomers that contain both alpha- and beta-amino acid residues in a 1:1 alternating pattern have recently been shown by several groups to adopt helical secondary structures in solution. The beta-residue substitution pattern has a profound effect on the type of helix formed and the stability of the helical conformation. On the basis of two-dimensional NMR data, we have previously proposed that beta-residues with a five-membered ring constraint promote two different types of alpha/beta-peptide helix. The "11-helix" contains i, i+3 CO...H-N hydrogen bonds between backbone amide groups; these hydrogen bonds occur in 11-atom rings. The alpha/beta-peptide "14/15-helix" contains i, i+4 CO...H-N hydrogen bonds, which occur in alternating 14- and 15-atom rings. Here we provide crystallographic data for 14 alpha/beta-peptides that form the 11-helix and/or the 14/15-helix. These results were obtained for a series of oligomers containing beta-residues derived from ( S,S)- trans-2-aminocyclopentanecarboxylic acid (ACPC) and alpha-residues derived from alpha-aminoisobutyric acid (Aib) or l-alanine (Ala). The crystallized alpha/beta-peptides range in length from 4 to 10 residues. Nine of the alpha/beta-peptides display the 11-helix in the solid state, three display the 14/15-helix, and two display conformations that contain both i, i+3 and i, i+4 CO...H-N hydrogen bonds, but not bifurcated hydrogen bonds. Only 3 of the 14 crystal structures presented here have been previously described. These results suggest that longer alpha/beta-peptides prefer the 14/15-helix over the 11-helix, a conclusion that is consistent with previously reported NMR data obtained in solution.  相似文献   

8.
This Feature Article summarizes our efforts in developing a new family of foldamers from alpha-, beta- and gamma-aminoxy acids. From a series of conformational studies, we demonstrate that peptides consisting of aminoxy acids adopt several well-defined secondary structures, such as alpha N-O turns (which feature an eight-membered-ring hydrogen bond), beta N-O turns (a nine-membered-ring hydrogen bond), gamma N-O turns (a ten-membered-ring hydrogen bond), 1.8(8) helices (consecutive homochiral alpha N-O turns), 7/8 helices (alternating alpha N-O turns and gamma-turns), 1.7(9) helices (consecutive beta N-O turns), reverse turns (consecutive heterochiral alpha N-O turns) and sheet-like structures.  相似文献   

9.
The effect of hydrogen peroxide, a main component of hair dye and decolorant treatments, on methamphetamine (MA) was studied. Two analytical methods, thin-layer chromatography (TLC) and high-performance liquid chromatography/mass spectrometry (LC/MS), were used for the separation and identification of MA derivatives. Mixtures of MA solutions and hydrogen peroxide that had been incubated at 39 degrees C for 24 h were shown to contain para-hydroxy MA by TLC and para-, meta- and ortho-hydroxy MAs by LC/MS. In addition, MA N-oxide and N-hydroxy MA were found in MA/hydrogen peroxide mixtures immediately after mixing. Therefore, we concluded that MA changed to MA N-oxide and N-hydroxy MA before changing to para-, meta- and ortho-hydroxy MAs.  相似文献   

10.
Helium is considered to be the ideal carrier gas for gas chromatography/mass spectrometry (GC/MS) in general, and for use with an ion trap in particular. Helium is an inert gas, can be used without special precautions for security and, moreover, it is needed as a damping gas in the trap. A disadvantage of helium is the high viscosity resulting in long GC run times. In this work hydrogen was tested as an alternative carrier gas for GC in performing GC/MS analyses. A hydrogen generator was used as a safe source of hydrogen gas. It is demonstrated that hydrogen can be used as a carrier gas for the gas chromatograph in combination with helium as make-up gas for the trap. The analysis time was thus shortened and the chromatographic performance was optimized. Although hydrogen has proven useful as a carrier gas in gas chromatography coupled to standard detectors such as ECD or FID, its use is not mentioned extensively in the literature concerning gas chromatography-ion trap mass spectrometry. However, it is worth considering as a possibility because of its chromatographic advantages and its advantageous price when using a hydrogen generator.  相似文献   

11.
Keto-enol tautomers of curcumin were confirmed by reversed-phase liquid chromatography(RPLC)/ hybrid quadrupole ion trap/time-of-flight mass spectrometry(QIT/TOFMS).Tautomers gave different MS/MS spectra in negative mode.Different mass spectra were also obtained by hydrogen/deuterium exchange LC/MS/MS in positive mode.Our results suggest that enol form is the major form in the solution(water/acetonitrile).  相似文献   

12.
This study describes an SPE coupled with large volume injection (LVI) analytical method for the analysis of organochlorine pesticides, BHC (alpha, beta, delta), aldrin, endosulfan (alpha, beta), endrin, dieldrin, and DDT, from aqueous samples. Determination was carried out by GC with MS. The LODs of organochlorine pesticides were determined at 10 ng/L concentration levels, and the results show that SPE-LVI-GC/MS has the potential to accurately determine organochlorine pesticides in water, as it avoids analyte classes in the various steps of a typical extraction procedure.  相似文献   

13.
Mass spectrometry of charged derivatives of peptides has been a growing area of interest in the past decade. Fragmentation of charged derivatives of peptides is believed to be different from than that of protonated peptides when analyzed by collisionally activated dissociation-tandem mass spectrometry (CAD-MS/MS). The charged derivatives fragment by charge-remote fragmentation mechanisms, which are usually classified as high-energy (HE)-CAD processes. Our objective in the present study is to investigate the mechanism of fragmentation of charged derivatives of peptides when analyzed by matrix-assisted laser desorption/ionization-postsource decay-mass spectrometry (MALDI-PSD-MS) and electrospray ionization (ESI)-CAD-MS/MS (ion trap), which involve low-energy processes. Three major types of hydrogens (alpha, beta, and amide) are available for migration during the formation of the *a(n) ions (the predominant ion series produced from these charged derivatives). To pinpoint which of the three hydrogens is involved in the formation of the *a(n) ions, deuterium-labeled peptide derivatives with labels at specific sites were synthesized and analyzed by MALDI-PSD-MS and ESI-CAD-MS/MS. Our results suggest that the amide hydrogen of the residue at which the cleavage occurs shifts during the formation of *a(n); this observation serves as evidence for the mechanism proposed earlier by Liao et al. for fragmentation of such charged derivatives. The results also help elucidate the structure of the *a(n) ions, *b(n) ions, and others formed during cleavage at the proline residue, as well as the ions formed during loss of the C-terminal residue from these charged derivatives.  相似文献   

14.
Reversible protein phosphorylation mediated by protein kinases and phosphatases is the most studied post-translational modification. Efficient characterization of phosphoproteomes is hampered by (1) low stoechiometry, (2) the dynamic nature of the phosphorylation process and (3) the difficulties of mass spectrometry to identify phosphoproteins from complex mixtures and to determine their sites of phosphorylation. Combination of the phosphopeptide enrichment method with MALDI-TOFMS, or alternatively, with HPLC-ESI-MS/MS and MS(3) analysis was shown to be a step forward for the successful application of MS in the study of protein phosphorylation. In our study we used phosphopeptide enrichment performed in a simple single-tube experiment using zirconium dioxide (ZrO(2)). A simple protein mixture containing precipitated bovine milk caseins was enzymatically digested and the mixture of tryptic fragments was analysed before and after enrichment using nanoflow HPLC-ESI-MS/MS and surface-enhanced laser desorption/ionization (SELDI)-MS/MS on QqTOF instruments to compare the efficiency of the two methods in the determination of phosphorylation sites. Both approaches confirm the high selectivity obtained by the use of batch-wise, ZrO(2)-based protocol using di-ammonium phosphate as the eluting buffer. More phosphorylation sites (five for beta-casein and three for alpha(S1)-casein) were characterized by SELDI-MS/MS than by nanoflow HPLC-ESI-MS/MS. Therefore, ZrO(2)-based phosphopeptide enrichment combined with SELDI-MS/MS is an attractive alternative to previously reported approaches for the study of protein phosphorylation in mixtures of low complexity with the advance of fast in situ peptide purification. The method was limited to successful analysis of high-abundance proteins. Only one phosphorylation site was determined for the minor casein component alpha(S2)-casein by ESI-MS/MS and none for kappa-casein. Therefore an improvement in enrichment efficiency, especially for successful phosphoproteomic applications, is needed.  相似文献   

15.
N-(Dicyclohexyl)acetylpiperidine-4-benzylidene-4-carboxylic acid (1) is an excellent in vitro inhibitor of 5 alpha-reductase (5 alpha R). Compound 1 showed, however, much lower inhibition activity of 5 alpha R in vivo than in vitro, which might be caused by poor membrane permeability. The methyl ester of 1 (1a) was therefore tested as a model prodrug to see if it has better permeability properties than the corresponding acid 1. It was also monitored that this methyl ester was cleaved into the active compound 1 within the DU145 cells. Quantitative matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOFMS) and high-performance liquid chromatography/tandem mass spectrometry (HPLC/MS/MS) methods were established with reliable linearity factors (0.996 for MALDI-TOFMS and 0.998 for HPLC/MS/MS) and reproducibility (relative standard deviation = 6.5% for MALDI-TOFMS and 2.8% for HPLC/MS/MS). The samples for MS analysis were effectively prepared from the cell homogenates using solid-phase extraction, with a high recovery of 90% on average. The intracellular amount of 1a (1.7 nmol) was much higher than that of 1 (0.032 nmol) in DU145 cells after 6 h of incubation. After incubation with the ester (1a), the cleaved acid (1) was detected within the cells. The concentration of acid 1 (0.045 nmol) in this experiment was higher than the acid content (0.032 nmol) after direct incubation with 1. Surprisingly, high amounts of the cleaved compound 1 were found outside the cells after 6 h of incubation with 1a.  相似文献   

16.
Endosufan, alpha and beta, and three conversion products, sulphate, ether and lactone, were simultaneously determined in human serum by means of an analytical procedure which combines extraction with organic solvents, clean-up with H(2)SO(4) and by liquid column chromatography, and detection by gas chromatography (GC) using electron capture detection (ECD) and tandem mass spectrometry (MS/MS). The procedure was validated and the values of some merit figures, such as linear range, detection and quantitation limits, accuracy, precision and recovery, obtained with the GC/ECD and the GC/MS/MS methods, were compared. The lower limits of detection in GC/ECD and GC/MS/MS were 0.03 and 0.05 microg I(-1), respectively. The recovery of the pesticides at the 20 microg I(-1) concentration level was 60-65%, with the exception of endosufan alpha. Recovery studies at higher levels (100 and 200 microg I(-1)) were independent of pesticide concentration in serum samples. The application of the proposed analytical methodology to the determination of endosulfans and their metabolites in real samples was tested by analyzing serum samples from a population living in agricultural areas of Almeria (Spain). The results show the advantage of MS/MS over the ECD detector in the analysis of serum samples where matrix interferences can be confused with target pesticides.  相似文献   

17.
Recently, mass spectrometry has been applied to studies of hydrogen exchange of backbone amides, allowing analysis of large proteins at physiological concentrations. Low resolution spatial information is obtained by digesting proteins after exchange into D2O, using electrospray ionization liquid chromatography/mass spectrometry (ESI-LC/MS) to measure deuteration by mass increases of resulting peptides. This study develops modeling paradigms to increase resolution, using the signal transduction kinase ERK2 as a prototype for larger, less stable proteins. In-exchange data for peptides were analyzed by nonlinear least squares and a maximum entropy method, distinguishing amides into fast, intermediate, slow, and nonexchanging classes. Analysis of completely nonexchanging or in-exchanging peptides and peptides with sequence overlaps showed that nonexchanging amides were generally hydrogen bonded and sterically constrained or buried > or = 2.2 A from the protein surface, while fast exchanging hydrogens were generally exposed at the protein surface. In order to more fully understand the intermediate and slow exchanging classes, an empirical model was developed by analyzing published exchange rates in cytochrome c. The model correlated protection factors with a combined dependency on surface accessibility, hydrogen bond length, and position of residues from alpha helix ends. Together with analysis of partial proteolytic products, the derived rules for exchange allowed modeling of exchange behavior of peptides. Substantial deviation from the predicted rates in some cases suggested a role for conformational freedom in regulating fast and intermediate exchanging amides.  相似文献   

18.
We report the observation of a new physical phenomenon of the addition of 2 hydrogen atoms to molecular ions thus forming [M + 2H]+ ions. We demonstrate such second hydrogen atom abstraction onto the molecular ions of pentaerythritol and trinitrotoluene (TNT). We used both gas chromatography mass spectrometry (GC‐MS) with supersonic molecular beam (SMB) with methanol added into its make‐up gas and electron ionization (EI) liquid chromatography mass spectrometry (LC‐MS) with SMB with methanol as the LC solvent. We found that the formation of methanol clusters resulted upon EI in the formation of dominant protonated pentaerythritol ion at m/z = 137 plus about 70% relative abundance of pentaerythritol molecular ion with 2 additional hydrogen atoms at m/z = 138 which is well above the 5.7% natural C13 isotope abundance of protonated pentaerythritol. Similarly, we found an abundant protonated TNT ion at m/z = 228 and a similar abundance of TNT molecular ion with 2 additional hydrogen atoms at m/z = 229. Upon the use of deuterated methanol (CD3OD) as the solvent, we observed an abundant m/z = 231 (M + 2D)+ of TNT with 2 deuterium atoms. We found such abundant second hydrogen atom abstraction with butylglycolate and at low abundances in dioctylphthalate, Vitamin K3, phenazine, and RDX. At this time, we are unable to report the magnitude and frequency of occurrence of this phenomenon in standard electrospray LC‐MS. This observation could have important implications on the provision of elemental formula from mass spectra that are involved with protonated molecules. Accordingly, while accurate mass measurements can serve for the generation of elemental formula, their further support and improvement via isotope abundance analysis are questionable. Consequently, if a given compound can be analyzed by both GC‐MS and LC‐MS, its GC‐MS analysis can be superior for the provision of accurate elemental formulae if its EI mass spectrum exhibits abundant molecular ions such as with GC‐MS with SMB (also known as cold EI).  相似文献   

19.
The novel and rapid assay presented here combines high-performance liquid chromatography and electrospray ionisation tandem mass spectrometry (HPLC-ESI-MS/MS) to directly measure and quantify the CoA esters of 3alpha,7alpha,12alpha-trihydroxy- and 3alpha,7alpha-dihydroxy-5beta-cholestan-26-oic acid (THCA and DHCA). The latter are converted inside peroxisomes to the primary bile acids, cholic and chenodeoxycholic acids, respectively. Prior to MS/MS, esters were separated by reversed-phase HPLC on a C(18) column using an isocratic mobile phase (acetonitrile/water/2-propanol) and subsequently detected by multiple reaction monitoring. For quantification, the CoA ester of deuterium-labelled 3alpha,7alpha,12alpha-trihydroxy-5beta-cholan-24-oic acid (d(4)-CA) was used as internal standard. To complete an assay took less than 8 min.To verify the validity of the assay, the effect of peroxisomal proteins on the efficacy of extraction of the CoA esters was tested. To this end, variable amounts of the CoA esters were spiked with a fixed amount of either intact peroxisomes or peroxisomal matrix proteins and then extracted using a solid-phase extraction system. The CoA esters could be reproducibly recovered in the range of 0.1-4 micromol l(-1) (linear correlation coefficient R(2) > 0.99), with a detection limit of 0.1 micromol l(-1).In summary, electrospray ionization tandem mass spectrometry combined with HPLC as described here proved to be a rapid and versatile technique for the determination of bile acid CoA esters in a mixture with peroxisomal proteins. This suggests this technique to become a valuable tool in studies dealing with the multi-step biosynthesis of bile acids and its disturbances in disorders like the Zellweger syndrome.  相似文献   

20.
Mass spectrometry as an analytical tool to study protein folding and structure by hydrogen/deuterium exchange is a relatively new approach. In this study, site-specific amide deuterium content was measured in oxidized and reduced E. coli thioredoxins by using the b(n) ions in electrospray ionization CID MS/MS experiments after 20-s incubation in D(2)O phosphate-buffered solution (pH 5.7). The deuterium levels correlated well with reported NMR-determined H/D exchange rate constants. The deuterium measured by y(n) ions, however, showed much less reliable correlation with rate exchange data. In general, residues in alpha helices and beta sheets, when measured by b(n) ions, showed low incorporation of deuterium while loops and turns had high deuterium levels. Most amide sites in the two protein forms showed similar deuterium levels consistent with the expected similarity of their structures, but there were some differences. The turn consisting of residues 18-22 in particular showed more variability in deuterium content consistent with reported structural differences in the two forms. The deuterium uptake by thioredoxins alkylated at Cys-32 by S-(2-chloroethyl)glutathione and S-(2-chloroethyl)cysteine, in peptides 1-24 and 45-58, was similar to that observed for oxidized and reduced thioredoxins, but several residues, particularly Leu-53 and Thr-54, showed slightly elevated deuterium levels, suggesting that structural changes had occurred from alkylation of the protein at Cys-32. It is concluded that b(n) ions are reliable for determining the extent of site-specific amide hydrogen isotope exchange and that mass spectrometry is useful as a complementary technique to NMR and other analytical methods for probing regional structural characteristics of proteins.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号