首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
The effects of buffer gas pressure on ion trap stability, mass resolution/calibration, and choice of mass scanning are described. Pressure effects were treated phenomenologically by adding a drag term to the ion equations of motion. The resulting collisional damping enlarges the mass-dependent stability region but reduces the region in which mass-selective resonance ejection can be performed. The pressure effects can be reduced by increasing the frequency of the alternating quadrupole field.  相似文献   

2.
3.
随着质谱技术的不断发展,对超高质量颗粒物质的分析已经成为质谱领域研究的一个重要方向.离子阱颗粒质谱(particle ion trap mass spectrometry)作为用于完整颗粒质量分析的有利工具,拓展了质谱技术在巨大颗粒物质量分析中的应用范围.本文对离子阱颗粒质谱仪器的研究进展及其在各个领域的应用进行了综述,并展望了离子阱颗粒质谱未来的发展趋势.  相似文献   

4.
The fullerenes C60 and C70 can be ionized by desorption from a liquid matrix upon bombardment by Cs+ ions of 7 keV kinetic energy. The resulting radical cations, when activated in the ion trap by collisions with Xe target, in the presence of helium, undergo extensive dissociation by loss of multiple C2 units. Large internal energies are deposited into these molecular ions and the dissociation efficiency is in excess of 60%.  相似文献   

5.
An ion trap source has been designed for use with time-of-flight (TOF) mass analysis. Two thin diaphragms make up a segmented ring electrode; the end cap electrodes are planar wire mesh. The potential field produced by the rf voltage applied between the ring and end cap electrodes resembles that of the cylindrical ion trap. The trapped ion population for ions created by electron impact exhibits linear growth against a first-order loss that has a time constant of about 50 µs; no ion loss occurs when the electron beam is off. The observed value of q z at low-mass cutoff for rf ion storage is ?0.84. Pulsed extraction of all ions is accomplished by switching the trap electrodes from rf to voltages required to provide a linear dc extraction field. The TOF flight path includes a wide energy range reflectron. Better than unit mass resolution is achieved through m/z 500 without collisional ion cooling. With an extraction rate of 1 kHz and a recording rate of 4 spectra per second, a linear working curve is obtained between 36 pg and 18 ng of chlorobenzene delivered chromatographically. The system has demonstrated the potential to achieve a very high sample utilization efficiency at high spectral generation rates.  相似文献   

6.
The use of a new hybrid quadrupole/linear ion trap known as the Q TRAP offers unique benefits as a LC-MS-MS detector for both small and large molecule analyses. The instrument combines the capabilities of a triple quadrupole mass spectrometer and ion trap technology on a single platform. Product ion scans are conducted in a hybrid fashion with the fragmentation step accomplished via acceleration into the collision cell followed by trapping and mass analysis in the Q3 linear ion trap. This results in triple quadrupole fragmentation patterns with no inherent low molecular mass cutoff. In-trap fragmentation is also possible in order to provide triple MS (MS3) capabilities. There are also several scan modes that are not possible on conventional instruments that enable identification of analytes within complex biological matrixes for subsequent high sensitivity product ion scans. This report will describe the new hybrid instrument and the principles of operation, and also provide examples of the unique scan modes and capabilities of the Q TRAP for LC-MS-MS detection in metabolism identification.  相似文献   

7.
Triacylglycerols (TAGs) isolated from a biological sample provide a challenge for mass spectrometric analysis because of the complexity of naturally occurring TAGs, which may contain different fatty acyl substituents resulting in a large number of molecular species having the identical elemental composition. We have investigated the use of mass spectrometry to obtain unambiguous information as to the individual TAG molecular species present in a complex mixture of triacylglycerols using a linear ion trap mass spectrometer. Ammonium adducts of TAGs, [M+NH4]+, were generated by electrospray ionization, which permitted the molecular weight of each TAG molecular species to be determined. The mechanisms involved in the decomposition of the [M+NH4]+ and subsequent fragment ions were investigated using deuterium labeling, MS/MS, and MS3 experiments. Collision induced decomposition of [M+NH4]+ ions resulted in the neutral loss of NH3 and an acyl side-chain (as a carboxylic acid) to generate a diacyl product ion. MS/MS data were used to identify each acyl group present for a given [M+NH4]+ ion, and this information could be combined with molecular weight data to identify possible TAG molecular species present in a biological extract. Subsequent MS3 experiments on the resultant diacyl product ions, which gave rise to acylium (RCO+) and related ions, enabled unambiguous TAG molecular assignments. These strategies of MS, MS/MS, and MS3 experiments were applied to identify components within a complex mixture of neutral lipids extracted from RAW 264.7 cells.  相似文献   

8.
The current status of quadrupole ion trap mass spectrometry is reviewed, with particular emphasis on liquid chromatographic coupling, membrane inlet introduction, laser desorption/ionisation and selective chemical ionisation. The flexibility, high sensitivity and multi-stage tandem mass spectrometric capability of the quadrupole ion trap are all illustrated.  相似文献   

9.
A two‐step laser desorption lamp ionization source coupled to an ion trap mass spectrometer (LDLI‐ITMS) has been constructed and characterized. The pulsed infrared (IR) output of an Nd:YAG laser (1064 nm) is directed to a target inside a chamber evacuated to ~15 Pa causing desorption of molecules from the target's surface. The desorbed molecules are ionized by a vacuum ultraviolet (VUV) lamp (filled with xenon, major wavelength at 148 nm). The resulting ions are stored and detected in a three‐dimensional quadrupole ion trap modified from a Finnigan Mat LCQ mass spectrometer operated at a pressure of ≥ 0.004 Pa. The limit of detection for desorbed coronene molecules is 1.5 pmol, which is about two orders of magnitude more sensitive than laser desorption laser ionization mass spectrometry using a fluorine excimer laser (157 nm) as the ionization source. The mass spectrum of four standard aromatic compounds (pyrene, coronene, rubrene and 1,4,8,11,15,18,22,25‐octabutoxy‐29H,31H‐phthalocyanine (OPC)) shows that parent ions dominate. By increasing the infrared laser power, this instrument is capable of detecting inorganic compounds. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

10.
A linear ion trap (LIT) with electrospray ionization (ESI) for top-down protein analysis has been constructed. An independent atmospheric sampling glow discharge ionization (ASGDI) source produces reagent ions for ion/ion reactions. The device is also meant to enable a wide variety of ion/ion reaction studies. To reduce the instrument's complexity and make it available for wide dissemination, only a few simple electronics components were custom built. The instrument functions as both a reaction vessel for gas-phase ion/ion reactions and a mass spectrometer using mass-selective axial ejection. Initial results demonstrate trapping efficiency of 70% to 90% and the ability to perform proton transfer reactions on intact protein ions, including dual polarity storage reactions, transmission mode reactions, and ion parking.  相似文献   

11.
Acylglycines are an important class of metabolites that have been used in the diagnosis of several inborn errors of metabolism (IEM). However, current analytical methods detect only a few acylglycines. There is a need to profile these metabolites in a comprehensive manner for studying their functions and improving their diagnostic values for different IEM and potentially other diseases. We describe a sensitive method that combines the chromatographic resolving power of ultra-performance liquid chromatography (UPLC) to separate closely related metabolites including isomers with tandem mass spectrometry (MS/MS). Acylglycines were extracted from urine using an anion exchange solid-phase extraction (SPE) cartridge. After UPLC separation, the acylglycines were detected on a hybrid triple quadrupole linear ion trap mass spectrometer. A set of standards were used for the development of an optimal MS acquisition method. Several acquisition modes using information derived from collisioninduced dissociation breakdown curves were used to detect acylglycines. Using this method, 18 acylglycines were detected in the urine of healthy individuals and confirmed using standards, while 47 additional acylglycines were detected and tentatively identified, based on their retention and fragmentation pattern. Among the 65 acylglycines detected, only 18 of them have been previously reported in biofluids of healthy individuals. These results will be deposited in a public human metabolome database. This example illustrates that by developing a method tailored to the analysis of a class of metabolites sharing similar structural moieties, we can potentially identify many more new metabolites, thereby expanding the overall metabolome coverage.  相似文献   

12.
The feasibility of experimental design in combination with subsequent response surface modelling was illustrated for the prediction and interpretation of tandem mass spectrometric (MS/MS) fragmentation data using a linear quadrupole ion trap under various experimental conditions. The instrumental parameters included were (i) the pressure of the collision gas, (ii) the collision energy, (iii) the fill time of the linear ion trap and (iv) the scan rate. The spectral intensity and width of five fragment ions of the doubly charged neuro-active peptide bombesin were used for evaluation, and all experiments were performed so as to resemble the results obtained from a liquid chromatographic peak. The reported results show how fairly simple mathematical tools can be utilized successfully to describe fundamental mechanisms associated with multiple collisional activation and collision-induced dissociation processes without an extensively controlled experimental environment. Most beneficial, using the suggested approach, is the ability to study interaction (synergistic) effects between various parameters. As was realized from the results, many interaction effects are indeed significant. For example, the effect on the signal intensity of different collision gas pressure settings is strongly dependent on the settings of the other parameters. The described approach can easily be adopted for optimization purposes of any MS/MS experiment.  相似文献   

13.
A linear-geometry, radio-frequency, quadrupole ion trap has been developed to generate, purify, accumulate and study atomic and molecular ions in the gas phase. By employing a trap-based system, both reactant and product ions can be stored for significant time periods, which can both enhance the efficiency of gas-phase reaction processes and create an environment to observe collision products after vibrational and rotational excitations have had time to relax. Relaxation occurs via viscous cooling with a dilute buffer gas or via laser cooling. Furthermore, the setup is particularly useful for performing optical spectroscopy on the trapped ions.Atomic and molecular ovens are used to generate thermal beams of neutral species, which are then ionized by electron bombardment. The ions can be trapped, or they can be collided with neutral molecules (e.g. C60) under well defined experimental conditions. The collision energies are variable over a range from nearly 0 to 200 eV. This feature makes possible studies of complex formation, charge transfer and collision-induced fragmentation as a function of kinetic energy. A wide range of masses of up to 4000 u can be stored and manipulated with this apparatus.Two mass spectrometric techniques for the analysis of trapped ionic species are presented. In one method, parametric excitation of the secular motion is used to generate mass spectra with resolutions as high as 1 part in 800 with a simple experimental setup. The second method is capable of quickly generating mass spectra over the entire range of trapped masses, but has only moderate resolution. These spectra are generated by linearly sweeping the rf-trapping voltage to zero and detecting ions as their trap depth falls below a threshold value. In the trapping volume, which is 10 cm in length and 200 μm in diameter, 106 ions can be loaded and stored, corresponding to an ion density above 108 cm−3. Such densities facilitate spectroscopy of the stored ions. Both laser-induced fluorescence and photodissociation measurements have been carried out with a cw laser system providing near-infrared, visible, and ultraviolet beams. Absolute, total cross-sections and branching ratios of the photodissociation of MgC+60 have been measured.  相似文献   

14.
This article presents the specificities of low pressure chemical ionization in ion trap mass spectrometry. One main feature is the ability to perform chemical ionization with liquid reagents as readily as with "conventional" gases (methane, isobutane and ammonia). The reactivities and analytical applications of gas and liquid reagents are summarized from literature data and are compared when possible.  相似文献   

15.
16.
The potential of boundary-effect activated dissociation (BAD) in ion trap tandem mass spectrometry (MS/MS) is discussed. Several classes of compounds were investigated and the BAD product ion tandem mass spectra were compared with those from collisionally activated dissociation (CAD) where an auxilliary r.f. ‘tickle’ voltage is used. The energy deposition in BAD MS/MS is generally lower than that for optimized CAD, but the experiments are easier to perform. An example of the BAD MS/MS of C10 alkylbenzenes and benzothiophene in diesel fuel using gas chromatographic introduction and predicted r.f. and d.c. voltages is presented.  相似文献   

17.
It is demonstrated that laser desorption ion trap mass spectrometry (LD-ITMS) can be successfully applied to the chemical analysis of a monolayer of adsorbates on a solid surface. Negative ion spectra obtained from LD-ITMS of self-assembled monolayers adsorbed from solutions of alkanethiols (CH3(CH2)nSH with N = 5, 9, and 15) onto polycrystalline gold surfaces displayed clear ion peaks corresponding to the sulfonate adsorbate species. Sulfonate ions with the general formula CH3(CH2)nSO3 were detected at m/z 165, 221, and 305, respectively, and were derived from the partial oxidation of the corresponding alkanethiol self-assembled monolayers. Little fragmentation and no clustering was observed in these mass spectra. These results indicate that the sensitivity of LD-ITMS is sufficient to allow its application to a wide array of problems in surface science.  相似文献   

18.
Discovery stage studies that address issues of absorption, distribution, metabolism and excretion (ADME) are vital for lead optimization resulting in new drug candidates. Often pharmacokinetics (PK) is assessed in these experiments without regard for the metabolism of the compound or the potential for metabolites to circulate in vivo. This work presents a strategy for drug level determination and detection of metabolites using dried blood spots for sample collection. Initially, metabolites are detected from microsomal incubations and characterized using tandem mass spectrometry. Data dependent enhanced MS and enhanced product ion (EMS-EPI) scanning with dynamic background subtraction was used on a hybrid quadruple linear ion trap mass spectrometer. On-the-fly background subtraction greatly improved the detection of metabolites. These data were used to build a multiple reaction monitoring (MRM) method for the parent and metabolites. MRM-EPI scanning was used to analyze the extracted dried blood spots from the PK study. Circulating metabolites were detected using MRM and their identities confirmed on the basis of fragment ion spectra collected simultaneously. The use of dried blood spots provides a means for re-analysis of PK samples for metabolite identification without the need for complex sample storage and preparation. Both parent compound and metabolite information can be collected in these studies, resulting in a savings of time and resources.  相似文献   

19.
A comprehensive study on the fragmentation pattern of the antimicrobial growth promoter avilamycin A was conducted in a quadrupole ion trap mass spectrometer equipped with an electrospray ionization (ESI) source. Performing multiple-stage experiments on the deprotonated molecule (m/z 1401) and its principal product ions showed that a sequential shortening of the oligosaccharide backbone took place, which can be attributed to the localization of the negative charge in the terminal dichloroisoeverninic acid. Under (+)-ESI conditions, avilamycin A readily formed an intense sodium-cationized molecule, [M + Na](+) (m/z 1425). Structural elucidation of the second-, third- and fourth-generation fragment ions revealed that all of the structures shared a common molecular portion comprising a central monosaccharide. This observation allowed us to assign confidently the complexation site of the alkali metal cation. In addition to the monosodiated molecule, the full-scan mass spectral acquisition also yielded a less abundant disodiated molecule, [M - H + 2Na](+) (m/z 1447). Multiple-stage experiments on this ion indicated that the second sodium ion compensates for the negative charge located at either of two positions within the molecule. While deprotonation of the phenolic hydroxyl group in the dichloroisoeverninic acid moiety was suggested to be driven by charge stabilization in the aromatic ring (in analogy with the deprotonated molecule in the (-)-ESI mode), the deprotonation at an alpha-carbon of an ester side-chain substituent in the oligosaccharide part was believed to provide a stable chelation-like coordination site for the cation.  相似文献   

20.
设为首页 | 免责声明 | 关于勤云 | 加入收藏