首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 109 毫秒
1.
Zhan X  Desiderio DM 《Electrophoresis》2003,24(11):1818-1833
The long-term goal of this research program is to clarify the molecular mechanisms that participate in the formation of human pituitary macroadenomas. One approach to that goal is to characterize the differentially expressed proteins that are found by a comparison of the proteomes of control pituitary vs. macroadenoma tissues. In order to accurately perform a comparative proteomics study, based on the combination of two-dimensional polyacrylamide gel electrophoresis (2-D PAGE) and PDQuest 2-D analysis software, a reproducible 2-DE separation system with a wide linear dynamic measure range is needed. A typical horizontal system is the Multiphor II system that analyzes one gel at a time, using a precast gradient gel (180 x 245 x 0.5 mm); a typical vertical system is the Dodeca system that analyzes up to 12 gels at a time on a single-concentration gel (190 x 205 x 1.0 mm). We have evaluated (Zhan and Desiderio, Electrophoresis 2003, 24, 1834-1846) the spatial and quantitative reproducibility of the two second-dimensional gel systems to separate a human pituitary proteome; that study showed a higher reproducibility for the Dodeca gel system. This present study investigated the relationship between the spot volume and the amount of protein loaded onto the gel for those two 2-D systems. The results demonstrated that the Dodeca gel system provides a wider linear dynamic range to measure the changes in the protein abundance in pituitary proteome.  相似文献   

2.
Choe LH  Lee KH 《Electrophoresis》2000,21(5):993-1000
We tested and compared three different commercially available instruments for isoelectric focusing for proteome analysis by two-dimensional protein electrophoresis. These instruments, the Multiphor, the IPGphor, and the Protean IEF cell, were used with 18 cm immobilized pH gradient strips and run under various conditions. The total number of spots and features was obtained by Melanie software (Bio-Rad Laboratories) and separately by visual inspection. The Multiphor consistently resulted in the highest number of spots detected per gel independent of sample type, immobilized pH gradient (IPG) and method to calculate the number of spots. The Protean IEF cell had the next highest number of spots detected per gel. In the experiments performed, the IPGphor afforded good reproducibility in the total number of Melanie-detected spots from gel to gel while the Protean IEF cell offered better reproducibility in the total number of manually detected spots from gel to gel. Among gels run with the different instruments, differences in the quality of the ammoniacal silver stain were also observed. A measure of quantitative reproducibility suggests that the Protean IEF cell, which was the easiest instrument to use, performs better than the other instruments, although all three instruments had demonstrated good quantitative reproducibility in the experiments performed.  相似文献   

3.
Horizontal two-dimensional (2-D) electrophoresis with immobilized pH gradients (IPG) in the first dimension for buffer soluble proteins and for complex proteins solubilized in the presence of Nonidet P-40 (G?rg et al., Electrophoresis 1987, 8, 45-51), has been extended to analyze basic proteins of yeast cells focused under non-equilibrium and equilibrium conditions. Transient state isoelectric focusing (IEF) in IPG gels revealed sample smearing and background staining, displaying horizontal streaks in the resultant 2-D patterns. Inclusion of 0.5% carrier ampholytes (CA) to the IPG gel (IPG-CA), resulted in the formation of many sharp protein bands after transient state IEF with resultant distinct spots in the 2-D patterns; however, resolution was poor and the gel contained heavy background staining. With prolonged focusing time, background staining disappeared and there was less difference in the final steady state IEF patterns obtained with IPG and IPG-CA. Reduction of the Immobiline concentration to one third the manufacturer's recommended amount did not improve IEF resolution with respect to streaking and background staining under either transient state or equilibrium conditions. In general, spot intensities were less on 2-D gels using diluted IPG gels than with "standard" IPG gels. Optimization of 2-D electrophoresis with IPGs in the first dimension was strongly related to IEF conditions. The use of IPG gels focused to equilibrium should not only improve inter-gel reproducibility and resolution but also the quality of the final 2-D patterns with respect to background staining and horizontal streaking.  相似文献   

4.
The number of protein spots detected on two-dimensional polyacrylamide gel electrophoresis (2-D PAGE) gels increases as the gel size increases. The largest commercially available systems resolve a few thousand spots, being only a fraction of the total proteome. We have developed an extremely long isoelectric focusing (IEF) system aimed at more complete protein profiling. The system is especially well suited to sensitive detection methods, such as radioactive detection. The major constraint preventing progress in this area has been the inability to create an even density gradient during the immobilized pH gradient (IPG) casting process. We demonstrate for the first time that this constraint can be effectively overcome, to enable greatly increased IEF separating power with all the advantages of IPG technology,  相似文献   

5.
Danos O  Svinartchouk F 《Electrophoresis》2006,27(17):3475-3479
2-DE is an important tool in proteomics research. However, intrinsic gel-to-gel variability of 2-DE often masks the biological differences between the samples and compromises quantitative comparison of protein expression levels. Here, we describe a modification of 2-DE that results in improved matching and quantification of proteins. This was accomplished by performing IEF of two samples in two IPG strips separated by a dialysis membrane. After IEF running, the strips were separated and the SDS-PAGE dimension was accomplished on two individual gels. After gel staining with CBB, ImageMaster 2D Platinum software (Amersham) was used for spot detection and quantification. Analysis of protein extracts from C2C12 myoblasts by this method resulted in 99% spot-matching efficiency and CV in stain intensity (% volume) was less than 0.5 for 98% of spots. We conclude that this technique, called dialysis-assisted gel electrophoresis, gives superior spot matching and quantitative reproducibility compared to IEF conducted on separate strips.  相似文献   

6.
A new isoelectric focusing (IEF) system for two-dimensional polyacrylamide gel electrophoresis (2-D PAGE) has been proposed. In this system, a super-soft and tough IEF gel was achieved by casting polyacrylamide gel down to 2.0% T using a loose multifilament string (LMS) of nylon as a gel support. The IEF apparatus for the LMS-gel, fabricated from acrylic boards, had a cooling water chamber, and eliminated the need of electrode solutions by directly connecting the two ends of individual gels to platinum electrodes. The carrier ampholyte-generated pH gradients using the new IEF system was stable over a long duration of time and a wide range of voltages, and the IEF time became shorter using a 2.0% T gel than using a 4.0% T gel. Also, the LMS-gels prepared in different runs exhibited excellent reproducibility. The new IEF system was applied to 2-D PAGE of a chicken skeletal muscle extract, and it was found that the protein loading capacity, protein entry into the LMS-gels, and protein transfer efficiency from the first-dimensional to the second-dimensional gels were significantly improved by using a low-concentration (2.5% T) gel. Also, proteins of high molecular weight of more than 200 kDa were observed in the 2-D maps, and therefore the new IEF system has a very good potential to be applied for fast 2-D PAGE of high molecular-weight proteins.  相似文献   

7.
J Asakawa 《Electrophoresis》1988,9(9):562-568
Two-dimensional electrophoresis (2-DE) with immobilized pH gradient (IPG) gels in capillary tubes was used in the first-dimensional isoelectric focusing (IEF) for the separation of human platelet polypeptides. Two types of IPG tube gels, pH ranges 4-8 and 7-10, containing 8 M urea, 1% Nonidet P-40 and 0.1% pH 3.5-10 Ampholine carrier ampholytes (CA) were prepared by a simple method not requiring special equipment. The addition of CA to both gel and sample solutions was essential in the tube gel IPG system. Proteins were visualized by a modification of Wray's silver-staining technique. The degree of resolution and the number of spots observed on an IPG 2-DE gel with pH 4-8 were comparable with those obtained with O'Farrell's high-resolution 2-DE. Approximately 200 basic polypeptides, which are difficult to separate by conventional CA-based IEF 2-DE or the non-equilibrium pH gradient system, were well resolved by 2-DE with a pH 7-10 IPG tube gel in the first-dimension. The gel patterns with either pH gradient 4-8 or 7-10 were highly reproducible among gels prepared and run simultaneously. These results demonstrated the potential and usefulness of the 2-DE system with IPG gels in capillary tubes.  相似文献   

8.
The goal of integrative top–down proteomics (i.e., two-dimensional gel electrophoresis [2DE] coupled with liquid chromatography and tandem mass spectrometry [LC/MS/MS]) is a routine analytical approach that fully addresses the breadth and depth of proteomes. To accomplish this, there should be no addition, removal, or modification to any constituent proteoforms. To address two-decade old claims of protein losses during front–end proteome resolution using 2DE, here we tested an alternate rehydration method for immobilized pH gradient strips prior to isoelectric focusing (IEF; i.e., faceup compared to facedown) and quantitatively assessed losses during the front–end of 2DE (rehydration and IEF). Using a well-established high-resolution, quantitative 2DE protocol, there were no detectable proteoform losses using the alternate faceup rehydration method. Although there is a <0.25% total loss of proteoforms during standard facedown rehydration, it is insignificant in terms of having any effect on overall proteome resolution (i.e., total spot count and total spot signal). This report is another milestone in integrative top–down proteomics, disproving long-held dogma in the field and confirming that quantitative front–end 2DE/LC/MS/MS is currently the only method to broadly and deeply analyze proteomes by resolving their constituent proteoforms.  相似文献   

9.
H P K?st 《Electrophoresis》1992,13(9-10):660-661
Isoelectric focusing (IEF) runs, e.g. on ultrathin gels, are characterized by an extensive change of gel electric parameters, caused by the rearrangement of carrier ampholyte components from a uniform distribution to a highly ordered pH gradient. A particularly important parameter is the specific resistance rho [Ohm*cm] which has been determined in polymerization mixtures (with and without carrier ampholytes) and in 125 x 0.15 mm ultrathin gels, pH 3-10 with 5% T, 3% C, 5% Servalyt carrier ampholytes, pH 3-10. The starting specific resistance rho of ultra-thin IEF gels, calculated from the geometric gel dimensions and electric current values (V, mA), is in agreement with the data determined directly in 30 mL samples of polymerization mixtures by using a conductivity meter. Electric specific conductivity/Volthour (Vh) plots proved to be a valuable tool for the evaluation of gel systems with and without protein samples during IEP runs. These plots are usually S-shaped, indicating that the key part of pH gradient formation takes places in a relatively short time. A "good" ultrahin gel, after a short lag phase, shows a rapid increase in specific resistance due to a rapid pH gradient formation and a slope of about 18 Ohm*cm/Vh. IEF is finished in about 3000 Vh. After prolonged gel storage, and especially in partially dried gels, the electrical parameters approach equilibrium only slowly, as indicated by the relatively shallow slope (8.9 Ohm*cm/Vh). Accordingly, separations need more than 4000 Vh.(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

10.
Cerebrospinal fluid (CSF) is in close proximity to the brain and changes in the protein composition of CSF may be indicative of altered brain protein expression in neurodegenerative disorders. Analysis of brain-specific proteins in CSF is complicated by the fact that most CSF proteins are derived from the plasma and tend to obscure less abundant proteins. By adopting a prefractionation step prior to two-dimensional gel electrophoresis (2-DE), less abundant proteins are enriched and can be detected in complex proteomes such as CSF. We have developed a method in which liquid-phase isoelectric focusing (IEF) is used to prefractionate individual CSF samples; selected IEF fractions are then analysed on SYPRO-Ruby-stained 2-D gels, with final protein identification by matrix-assisted laser desorption/ionisation time-of-flight mass spectrometry (MALDI-TOFMS). To optimise the focusing of the protein spots on the 2-D gel, the ampholyte concentration in liquid-phase IEF was minimised and the focusing time in the first dimension was increased. When comparing 2-D gels from individual prefractionated and unfractionated CSF samples it is evident that individual protein spots are larger and contain more protein after prefractionation of CSF. Generally, more protein spots were also detected in the 2-D gels from prefractionated CSF compared with direct 2-DE separations of CSF. Several proteins, including cystatin C, IgM-kappa, hemopexin, acetyl-coenzyme A carboxylase-alpha, and alpha-1-acid glycoprotein, were identified in prefractionated CSF but not in unfractionated CSF. Low abundant forms of posttranslationally modified proteins, e.g. alpha-1-acid glycoprotein and alpha-2-HS glycoprotein, can be enriched, thus better resolved and detected on the 2-D gel. Liquid-phase IEF, as a prefractionation step prior to 2-DE, reduce sample complexity, facilitate detection of less abundant protein components, increases the protein loads and the protein amount in each gel spot for MALDI-MS analysis.  相似文献   

11.
The use of cup-loading for sample application has become widely used in two-dimensional electrophoresis (2-DE) for resolution of basic proteins, but no side-by-side quantitative study has been published which compares cup-loading with the alternative passive and active rehydration methods to fully promote one type of loading method over another. Replicate 2-D gels from each loading method were quantitatively evaluated for gel-to-gel reproducibility using IPG 6-11 strips and semipreparative protein loads (300 microg). Gels were stained with SYPRO Ruby and analyzed with PDQuest. An inexpensive home-made assembly for cup-loading was used with the Protean IEF Cell for separation of whole cell extracts from the archaeon, Sulfolobus solfataricus. Cup-loading was determined to be far superior for IPG 6-11 separations than active or passive rehydration methods. Cup-loading consistently produced the greatest number of detectable spots, the best spot matching efficiency (56%), lowest spot quantity variations (28% coefficient of variation, CV), and the best-looking gels qualitatively. The least satisfactory results were obtained with active rehydration, followed closely by passive rehydration in off-line tubes. Passive rehydration experiments, performed using an on-line isoelectric focusing (IEF) tray, produced comparable spot numbers to cup-loading (84%), with 55% of the spots having higher intensity but 10% more spot quantity variance than cup-loading.  相似文献   

12.
SYPRO Ruby IEF Protein Gel Stain is an ultrasensitive, luminescent stain optimized for the analysis of protein in isoelectric focusing gels. Proteins are stained in a ruthenium-containing metal complex overnight and then rinsed in distilled water for 2 h. Stained proteins can be excited by ultraviolet light of about 302 nm (UV-B transilluminator) or with visible light of about 470 nm. Fluorescence emission of the dye is maximal at approximately 610 nm. The sensitivity of the SYPRO Ruby IEF protein gel stain is superior to colloidal Coomassie blue stain and the highest sensitivity silver staining procedures available. The SYPRO Ruby IEF protein gel stain is suitable for staining proteins in nondenaturing or denaturing carrier ampholyte isoelectric focusing and immobilized pH gradient gel electrophoresis. The stain is compatible with N,N'-methylenebisacrylamide or piperazine diacylamide cross-linked polyacrylamide gels as well as with agarose gels and high tensile strength Duracryl gels. The stain does not contain extraneous chemicals (formaldehyde, glutaraldehyde, Tween-20) that frequently interfere with peptide identification in mass spectrometry. Successful identification of stained proteins by peptide mass profiling is demonstrated.  相似文献   

13.
在微流控芯片上构建多维分离系统,为蛋白质组学研究提供了一个有发展前景的高效分离分析技术平台。本文介绍了二维芯片电泳系统耦联模式选取及正交性评价的方法;综述了针对蛋白质/多肽分离分析的各种耦联模式微流控二维芯片电泳分析系统,如胶束电动力学色谱(MEKC)与毛细管区带电泳(CZE),开管电色谱(OECE)与CZE,等电聚焦(IEF)与CZE, IEF与SDS毛细管凝胶电泳(CGE), SDS-CGE与MEKC等。特别对二维电泳芯片切换接口的类型进行了分类,探讨了用于微流控二维芯片电泳系统的检测技术,并展望了微流控二维电泳芯片在蛋白质组学研究中的应用前景和发展方向。  相似文献   

14.
Over the past several years, a large effort has been focused on improvements of two-dimensional (2-D) gel electrophoresis-based proteomics technology, and on development of novel approaches for proteome analysis. Here, we describe the application of an alternative strategy for the analysis of complex proteomes. The strategy combines isoelectric focusing in immobilized pH gradient strips (in-gel IEF), mass spectrometry (MS), and bioinformatics. A protein mixture is separated by in-gel IEF, and the entire strip is cut into a set of gel sections. Proteins in each gel section are digested with trypsin, and the tryptic peptides are subjected to liquid chromatography-nanoelectrospray-quadrupole ion-trap tandem mass spectrometry (LC-ESI-MS/MS). The LC-ESI-MS/MS data are used to identify the proteins through searches of a protein sequence database. Using this in-gel IEF-LC-MS/MS strategy, we have identified 127 proteins from a human pituitary. This study demonstrates the potential of the in-gel IEF-LC-MS/MS approach for analyses of complex mammalian proteomes.  相似文献   

15.
Two-dimensional gel electrophoresis using immobilized pH gradient tube gels   总被引:1,自引:0,他引:1  
An apparatus for the preparation of gels for immobilized pH gradient isoelectric focusing (IPG) in glass tubes was developed. Using this apparatus, the highly reproducible immobilized pH gradient can be formed with Immobilines in polyacrylamide gels, and IPG gels at all possible pH ranges can be easily prepared at low cost. The IPG tube gels in the first dimension in two-dimensional gel electrophoresis was used to separate and identify a number of rice embryo proteins in the proteome analysis. There was no difference in resolution of proteins between the tube gels and the commercially available slab gels; after electrophoresis, however, we could efficiently obtain a larger amount of the purified proteins from the tube gels than from the slab gels.  相似文献   

16.
《Electrophoresis》2018,39(7):965-980
Two‐dimensional gel electrophoresis (2DE) in proteomics is traditionally assumed to contain only one or two proteins in each 2DE spot. However, 2DE resolution is being complemented by the rapid development of high sensitivity mass spectrometers. Here we compared MALDI‐MS, LC‐Q‐TOF MS and LC‐Orbitrap Velos MS for the identification of proteins within one spot. With LC‐Orbitrap Velos MS each Coomassie Blue‐stained 2DE spot contained an average of at least 42 and 63 proteins/spot in an analysis of a human glioblastoma proteome and a human pituitary adenoma proteome, respectively, if a single gel spot was analyzed. If a pool of three matched gel spots was analyzed this number further increased up to an average of 230 and 118 proteins/spot for glioblastoma and pituitary adenoma proteome, respectively. Multiple proteins per spot confirm the necessity of isotopic labeling in large‐scale quantification of different protein species in a proteome. Furthermore, a protein abundance analysis revealed that most of the identified proteins in each analyzed 2DE spot were low‐abundance proteins. Many proteins were present in several of the analyzed spots showing the ability of 2DE‐MS to separate at the protein species level. Therefore, 2DE coupled with high‐sensitivity LC‐MS has a clearly higher sensitivity as expected until now to detect, identify and quantify low abundance proteins in a complex human proteome with an estimated resolution of about 500 000 protein species. This clearly exceeds the resolution power of bottom‐up LC‐MS investigations.  相似文献   

17.
Intact protein masses can be measured directly from immobilized pH gradient (IPG) isoelectric focusing (IEF) gels loaded with mammalian and prokaryotic samples, as demonstrated here with murine macrophage and Methanosarcina acetivorans cell lysates. Mass accuracy and resolution is improved by employing instruments which decouple the desorption event from mass measurement; e.g., quadrupole time-of-flight instruments. MALDI in-source dissociation (ISD) is discussed as a means to pursue top-down sequencing for protein identification. Methods have been developed to enzymatically digest all proteins in an IEF gel simultaneously, leaving the polyacrylamide gel attached to its polyester support. By retaining all gel pieces and their placement relative to one another, sample handling and tracking are minimized, and comparison to 2-D gel images is facilitated. MALDI-MS and MS/MS can then be performed directly from dried, matrix-treated IPG strips following whole-gel trypsin digestion, bottom-up methodology. Side-to-side proteomics, highlighting the link between virtual and classical 2-D gel electrophoresis, is introduced to describe a method whereby intact masses are measured from one side (the IEF gel), while proteins are identified based on analyses performed from the other side (the SDS-PAGE gel).  相似文献   

18.
The characteristics of protein detection and quantitation with SYPRO Ruby protein gel stain in one- and two-dimensional polyacrylamide gels were evaluated. Sodium dodecyl sulfate-polyacrylamide gel electrophoresis (SDS-PAGE) analyses of three different purified recombinant proteins showed that the limits of detection were comparable to the limits of detection with ammoniacal silver staining and were protein-specific, ranging from 0.5 to 5 ng. The linearity of the relationship between protein level and SYPRO Ruby staining intensity also depended on the individual protein, with observed linear dynamic ranges of 200-, 500-, and, 1000-fold for proteins analyzed by SDS-PAGE. SYPRO Ruby protein gel stain was also evaluated in two-dimensional electrophoretic (2-DE) analysis of Escherichia coli proteins. The experiment involved analysis of replicates of the same sample as well as dilution of the sample from 0.5 to 50 nug total protein across gels. In addition to validating the 2-DE system itself, the experiment was used to evaluate three different image analysis programs: Z3 (Compugen), Progenesis (Nonlinear Dynamics), and PDQuest (Bio-Rad). In each program, we analyzed the 2-DE images with respect to sensitivity and reproducibility of overall protein spot detection, as well as linearity of response for 20 representative proteins of different molecular weights and pI. Across all three programs, coefficients of variation (CV) in total number of spots detected among replicate gels ranged from 4 to 11%. For the 20 representative proteins, spot quantitation was also comparable with CVs for gel-to-gel reproducibility ranging from 3 to 33%. Using Progenesis and PDQuest, a 1000-fold linear dynamic range of SYPRO Ruby was demonstrated with a single known protein. These two programs were more suitable than Z3 for examining individual protein spot quantity across a series of gels and gave comparable results.  相似文献   

19.
To separate and analyze giant and small proteins in the same electrophoresis gel, we have used a 3–15% polyacrylamide gradient gel containing 2.6% of the crosslinker bisacrylamide and 0.2 M of Tris‐acetate buffer (pH 7.0). Samples were prepared in a sample buffer containing lithium dodecyl sulphate and were run in the gel described above using Tris‐Tricine‐SDS‐sodium bisulfite buffer, pH 8.2, as electrophoresis buffer. Here, we show that this system can be successfully used for general applications of SDS‐PAGE such as CBB staining and immunoblot. Thus, by using Tris‐acetate 3–15% polyacrylamide gels, it is possible to simultaneously analyze proteins, in the mass range of 10–500 kDa, such as HERC1 (532 kDa), HERC2 (528 kDa), mTOR (289 kDa), Clathrin heavy chain (192 kDa), RSK (90 kDa), S6K (70 kDa), β‐actin (42 kDa), Ran (24 kDa) and LC3 (18 kDa). This system is highly sensitive since it allows detection from as low as 10 μg of total protein per lane. Moreover, it has a good resolution, low cost, high reproducibility and allows for analysis of proteins in a wide range of weights within a short period of time. All these features together with the use of a standard electrophoresis apparatus make the Tris‐acetate‐PAGE system a very helpful tool for protein analysis.  相似文献   

20.
Kashino Y  Koike H  Satoh K 《Electrophoresis》2001,22(6):1004-1007
Membrane protein complexes such as the reaction center complexes of oxygenic photosynthesis or the complex I of mitochondira are composed of many subunit polypeptides. To analyze their polypeptide compositions by sodium dodecyl sulfate-polyacrylamide gel electrophoresis (SDS-PAGE), a wide range of molecular sizes has to be resolved, especially in the low molecular mass range. We have improved the traditional Tris/HCI buffer systems adopting a Tris/2-(N-morpholino)ethanesulfonic acid (MES) buffer system containing 6 M urea. This gel system was used with an 18-24% acrylamide gradient for the separation of polypeptides with molecular masses from below 5 kDa to over 100 kDa. This buffer system can also be applied to the usual uniform concentration of acrylamide gel and also to minislab gels.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号