首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
WJ Choi  KS Park  TJ Eom  MK Oh  BH Lee 《Optics letters》2012,37(14):2784-2786
We propose a label-free depth-resolved tomographic scheme for imaging a single live cell in fluid. This approach utilizes a modified time-domain full-field optical coherence tomography (FF-OCT) system combined with an optical tweezer technique. The optical trap for holding a moving specimen is made by tightly focusing a 1064 nm Q-switching pulsed laser beam with a 1.0 NA microscope objective in the sample arm of the FF-OCT part. By cosharing the probe for both systems, the optical actions of trapping and cellular resolution tomographic imaging could be achieved simultaneously. Feasibility of the combined system is demonstrated by imaging micron-sized polystyrene beads and a living suspension cell in medium.  相似文献   

2.
A multilayered scattering structure is proposed and demonstrated as a reference mirror for use with full field optical coherence tomography (FF-OCT) to increase contrast of tissue imaging and provide compensation. Common-path FF-OCT systems were built demonstrating high resolution cell profiling. The use of this mirror with frequency domain FF-OCT allows 3D images in real time.  相似文献   

3.
We developed an ultrahigh-resolution full-field optical coherence tomography (FF-OCT) microscope that is based on the spatial, rather than the temporal, coherence gating. The microscope is capable of observing three-dimensional microbiological structures as small as 0.4 μm × 0.4 μm × 1.0 μm (xyz) using quasi-monochromatic light and a liquid crystal retarder. Unlike traditional FF-OCT systems, this microscope can be operated in high resolution for any preferable wavelength with minimized defocusing and dispersion effects. High-resolution images of an onion cell are presented.  相似文献   

4.
In vivo full-field (FF) optical coherence tomography (OCT) images of human retina are presented by using a rapidly tunable laser source in combination with an ultra-high-speed camera. Fourier-domain FF-OCT provided a way to increase the speed of retinal imaging by parallel acquisition of A-scans. Reduced contrast caused by cross talk was observed only below the retinal pigment epithelium. With a 100Hz sweep rate, FF-OCT was fast enough to acquire OCT images with acceptable motion artifacts. FF-OCT allows ultrafast retinal imaging, boosting image speed by a lack of moving parts and a considerably higher irradiation power.  相似文献   

5.
宽场相干断层成像技术(WFOCT)具有提高OCT系统的扫描速率和实现高分辨率的三维显微技术等优点,成为当前研究的热点。本文阐述了WFOCT的基本原理,利用八步移相法重建出玻璃物体微细结构的断层图像,研究了宽场OCT系统对玻璃材料的纵向分辨率和探测深度,其中探测深度可达3.3 mm。在获得多幅断层图像的基础上,利用VC6.0和OpenGL混合编程,采用移动立方体(MC)算法重建出玻璃物体微细结构的三维图像。实验结果表明,WFOCT系统不但能够在生物组织检测等医学方面得到应用,而且对反射率较高的物体能够完成三维形貌显微成像探测和深度探测。  相似文献   

6.
We describe a novel optical system for bidirectional color Doppler imaging of flow in biological tissues with micrometer-scale resolution and demonstrate its use for in vivo imaging of blood flow in an animal model. Our technique, color Doppler optical coherence tomography (CDOCT), performs spatially localized optical Doppler velocimetry by use of scanning low-coherence interferometry. CDOCT is an extension of optical coherence tomography (OCT), employing coherent signal-acquisition electronics and joint time-frequency analysis algorithms to perform flow imaging simultaneous with conventional OCT imaging. Cross-sectional maps of blood flow velocity with <50-microm spatial resolution and <0.6-mm/s velocity precision were obtained through intact skin in living hamster subdermal tissue. This technology has several potential medical applications.  相似文献   

7.
双光栅快速扫描光学延迟线的色散补偿   总被引:1,自引:0,他引:1  
李栋  丁志华  孟婕 《光学学报》2007,27(3):505-509
光学相干层析成像(OCT)系统的纵向分辨力不仅与光源的带宽有关,而且与系统中两干涉臂间的色散匹配有关。如果色散没有得到精确匹配,将使光学相干层析成像系统的纵向分辨力达不到所预期的理论值。色散问题在超高分辨光学相干层析成像系统中尤为突出。提出了一种基于双光栅快速扫描光学延迟线(RSOD),用于光学相干层析成像系统的色散补偿。该方法中新增的光栅引入了光栅间距这一独立变量,其与常规单光栅快速扫描光学延迟线机构中的光栅离焦量一起,可使光学相干层析成像系统中的群速度色散(GVD)和三阶色散(TOD)同时得到补偿。分析了双光栅快速扫描光学延迟线的色散特性和色散调节原则,并提供了一个典型光学相干层析成像系统中的色散补偿实例。  相似文献   

8.
Thermal-light full-field optical coherence tomography   总被引:2,自引:0,他引:2  
We have built a high-resolution optical coherence tomography (OCT) system, based on a Linnik-type interference microscope, illuminated by a white-light thermal lamp. The extremely short coherence length of the illumination source and the large aperture of the objectives permit resolution close to 1 microm in three dimensions. A parallel detection scheme with a CCD camera provides cross-section (x-y) image acquisition without scanning at a rate of up to 50 Hz. To our knowledge, our system has the highest resolution demonstrated to date for OCT imaging. With identical resolution in three dimensions, realistic volume rendering of structures inside biological tissues is possible.  相似文献   

9.
Tao YK  Ehlers JP  Toth CA  Izatt JA 《Optics letters》2010,35(20):3315-3317
We demonstrate in vivo human retinal imaging using an intraoperative microscope-mounted optical coherence tomography system (MMOCT). Our optomechanical design adapts an Oculus Binocular Indirect Ophthalmo Microscope (BIOM3), suspended from a Leica ophthalmic surgical microscope, with spectral domain optical coherence tomography (SD-OCT) scanning and relay optics. The MMOCT enables wide-field noncontact real-time cross-sectional imaging of retinal structure, allowing for SD-OCT augmented intrasurgical microscopy for intraocular visualization. We experimentally quantify the axial and lateral resolution of the MMOCT and demonstrate fundus imaging at a 20Hz frame rate.  相似文献   

10.
A new optical coherence tomography system using a wavelength-scanning laser source is presented. The system has the advantage that the depth resolution can be controlled by the scanning range. In general, rapid scanning of the wavelength varies the output power of the laser source, and it is difficult to detect a weak signal of reflected light from the scattering object. By synchronizing the intensity-integrated detector with the variation, the dynamic range of the detection has been improved. To confirm the performance, tomographic imaging of biological tissues is demonstrated.  相似文献   

11.
We have developed a novel phase-resolved optical coherence tomography (OCT) and optical Doppler tomography (ODT) system that uses phase information derived from a Hilbert transformation to image blood flow in human skin with fast scanning speed and high velocity sensitivity. Using the phase change between sequential scans to construct flow-velocity imaging, this technique decouples spatial resolution and velocity sensitivity in flow images and increases imaging speed by more than 2 orders of magnitude without compromising spatial resolution or velocity sensitivity. The minimum flow velocity that can be detected with an axial-line scanning speed of 400 Hz and an average phase change over eight sequential scans is as low as 10 microm/s, while a spatial resolution of 10 microm is maintained. Using this technique, we present what are to our knowledge the first phase-resolved OCT/ODT images of blood flow in human skin.  相似文献   

12.
周琳  丁志华  俞晓峰 《光学学报》2005,25(9):181-1185
光学相十层析成像(光学相干层析成像术)的轴向分辨力由光源带宽和探测光束的聚焦条件共同决定。提高光学相干层析成像术轴向分辨力的方法主要基于带宽光源技术。提出了一种将变迹术与光学相十层析成像术相干门有机结合的方法来提高其轴向分辨力。通过适当形式的光瞳滤波器.使光学相干层析成像术系统轴向响应的主瓣宽度缩小到相干门之内,而其旁瓣则处于相干门之外.不对相干成像产生有效贡献。这样.就能在光源带宽不变的条件下,有效提高光学相十层析成像术的轴向分辨力,避免了采用宽带光源所带来的费用昂贵和系统复杂等缺陷。  相似文献   

13.
低相干光断层扫描系统的噪声分析与研究   总被引:3,自引:0,他引:3  
低相干光断层扫描,是近十几年来发展起来集多种前沿科学和技术为一体的超高精度成像技术。介绍了该技术的理论原理及本实验室建立的基于时域线性调制和光纤迈克耳孙干涉仪的低相干光断层扫描系统并给出了初步的实验结果。重点对光源谱型和参考臂扫描速度不均匀性对系统输出信噪比的影响进行了理论模拟计算和实验研究。通过运用傅里叶频谱的分析方法,从工程设计的角度出发给出了基于实验结果的参量特性分析以及这些特性将会给实际光学相干层析系统测量结果带来的影响,从而获得了低相干光断层扫描系统改进的方法。  相似文献   

14.
A nonreciprocal fiber-optic interferometer is demonstrated in an optical coherence tomography (OCT) system. The increased power efficiency of this system provides a 4.1-dB advantage over standard Michelson implementations. In addition, a new linear-scanning fiber-optic catheter is demonstrated that avoids the rotary optical junction that is required in circumferential scanning systems. These advancements have permitted the clinical implementation of OCT imaging in the human gastrointestinal tract.  相似文献   

15.
Graf RN  Brown WJ  Wax A 《Optics letters》2008,33(12):1285-1287
We use a parallel frequency-domain optical coherence tomography (FDOCT) system to generate a scatter-mode image of the hamster cheek pouch epithelium. To our knowledge, this is the first optical coherence tomography (OCT) image of a biological sample obtained using a thermal light source in the frequency domain. The system employs an imaging spectrometer to acquire depth-resolved profiles from adjacent spatial points without the need for any scanning. To enable this imaging modality, we have considered that signals originating from multiple depths combine in a different manner in FDOCT compared to time-domain optical coherence tomography (TDOCT). Because a multicomponent FDOCT signal is a coherent sum, it is necessary to limit the number of modes that contribute to the detected signal. Conversely, multicomponent TDOCT signals can be represented as incoherent sums, where increasing the number of modes improves the signal.  相似文献   

16.
赵晨  陈志彦  丁志华  李鹏  沈毅  倪秧 《物理学报》2014,63(19):194201-194201
针对玻璃缺陷在线无损检测的迫切需求,本文报道了一种基于线照明并行谱域光学相干层析成像系统的大视场检测系统.该系统采用快速面阵CMOS相机,单次拍摄即可获取完整的横截面(B-scan)图像.基于线照明面阵探测器的并行谱域光学相干层析成像系统,可以同时获取沿线照明方向各位置处的深度分辨信息,避免了横向扫描机构的应用.研制系统的轴向分辨率为17.9μm,并行方向上的横向分辨率55.7μm,扫描方向上的横向分辨率为24.8μm,轴向扫描速率为128 000 A-scan/s,横向视场为32 mm,空气中成像深度大于6 mm,成像灵敏度达到62 dB以上.利用研制的线照明并行谱域光学相干层析成像系统,开展了不同类型玻璃表面及其内部缺陷的检测应用研究.  相似文献   

17.
Full-range Fourier domain optical coherence tomography (FD-OCT) is generally achieved using a phase shifting algorithm. A novel design is presented for a one-shot full-range Fourier domain optical coherence tomography (FD-OCT) system utilizing orthogonally polarized light. The phase-shifted interferograms required to reconstruct the sample structure are obtained using an apochromatic quarter-wave retarder rather than a mechanical scanning operation, and thus the imaging results are free of vibrational-induced errors. The numerical analysis shows that it enhances the quality of high resolution FD-OCT and reduces the acquisition time. Moreover, the simulation results show that the proposed system is robust toward both the presence of noise in the power spectrum of the super luminescent diode (SLD) and a slight non-orthogonality of the two light beams incident on the spectrum analyzers, respectively.  相似文献   

18.
Xie T  Mukai D  Guo S  Brenner M  Chen Z 《Optics letters》2005,30(14):1803-1805
A fiber-optic-bundle-based optical coherence tomography (OCT) probe method is presented. The experimental results demonstrate this multimode optical fiber-bundle-based OCT system can achieve a lateral resolution of 12 microm and an axial resolution of 10 microm with a superluminescent diode source. This novel OCT imaging approach eliminates any moving parts in the probe and has a primary advantage for use in extremely compact and safe OCT endoscopes for imaging internal organs and great potential to be combined with confocal endoscopic microscopy.  相似文献   

19.
高分辨率快速数字化光声CT乳腺肿瘤成像   总被引:3,自引:0,他引:3       下载免费PDF全文
向良忠  邢达  郭华  杨思华 《物理学报》2009,58(7):4610-4617
提出了一种基于聚焦线性阵列探测器的快速光声计算机断层成像技术(光声CT).在光声二维图像重建中,根据阵列探测器机械扫描和电子扫描相结合的组合扫描模式,提出了改进的有限场滤波反投影重建算法.一方面该算法适合多元探测器旋转扫描模式,另一方面探测器的指向性函数作为反投影的权重因子提高了系统的横向分辨率.同时,该成像系统还利用柱面声透镜实现Z轴方向上的聚焦扫描以实现三维层析成像.实验中,这套成像系统空间分辨率达到0.2mm,Z轴方向分辨率为1.5mm,扫描一幅二维图像仅需150s,得到 关键词: 光声CT 有限场滤波反投影算法 声透镜聚焦 乳腺肿瘤检测  相似文献   

20.
为了同时获取样品的表面和深度信息,研究光学相干层析的成像原理,建立了基于光学相干层析技术的内窥系统,实现了旋转扫描成像,系统的工作波长为1 310 nm,工作带宽为80 nm.理论推导及计算机仿真得到了系统信噪比与干涉仪的分光比、反射率之间的关系并分析了理论分辨率和探测深度.提出外径为5 mm的内窥镜扫描探头,聚焦距离为12 mm,数值孔径NA为0.47,折射率分布常量A=0.218 7.利用微型电机驱动直角棱镜实现扫描,旋转速度为25 rpm,旋转一周得到640个采样点.采用多层盖玻片和洋葱表皮作为样品进行实验分析,得到了盖玻片和洋葱的图像,横向分辨率和纵向分辨率分别为10 μm和15 μm.结果表明,设计的光学相干层析内窥系统能够用于旋转扫描成像,获取更多的组织信息.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号