首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 944 毫秒
1.
《X射线光谱测定》2004,33(6):414-420
Airborne particles were investigated in the central part of Riga during October 2000. Mass, black carbon and elemental concentrations of airborne particles were measured on Teflon filters from a dichotomous impactor, which samples fine (<2.5 µm) and coarse (2.5–10 µm) fractions of particles. In order to obtain more detailed information on the size distributions of different elements, a seven‐stage Batelle cascade impactor was used, in which quartz plates treated with silicone grease were utilized as backing for the different stages. Total reflection x‐ray fluorescence (TXRF) and energy‐dispersive x‐ray fluorescence (EDXRF) spectrometry were used for elemental analysis on the quartz plates and Teflon filters. The environmentally mobile part of the fine particle elements in the aerosol was determined by subtraction of x‐ray spectra measured before and after sequential leaching of the aerosol filters. The results of the different measurements show that naturally generated street dust and soil particles are dominant in coarse particles, whereas particles generated by human activities are dominant in the size fraction <0.5 µm. Copyright © 2004 John Wiley & Sons, Ltd.  相似文献   

2.
Trace elements in near‐ground atmospheric aerosols were investigated in Dar es Salaam, Tanzania. Particles were collected at two sites, one urban and one rural, during two months with different meteorological conditions. The samplers, dichotomous impactors, segregate the particles into two size fractions, fine (PM2.5, da < 2.5 µ m) and coarse (2.5 < da < 10 µ m). A sharp cyclone was used to sample finer particles (PM1, da < 1 µ m). Meteorological parameters were also examined at both sites. An EDXRF spectrometer, based on three‐axial geometry, was used for quantitative elemental analysis. Concentrations of elements heavier than phosphorus were determined. Also, the content of black carbon on the filters was measured with a reflectometer. The elemental concentrations were compared with respect to season and geographical location in the city. The levels of different species in Dar es Salaam were also compared with similar data from other African and European countries. This showed low values of Pb with respect to the size of the city and no legislation on the use of leaded petrol, that often is the main source of lead. High values of Cl were also found, as would be expected in a coastal city. The coarse particles in the air, originating from soil, had a different composition in Dar es Salaam than in Gaborone, Botswana, and the concentration of black carbon was higher than in other cities. On the basis of the data collected, source assignments were made and the following sources found; sea‐spray, soil, city road dust, biomass burning, industries and traffic. Comparing the concentrations of different elements in PM2.5 and PM1 revealed that black carbon, Zn, Pb, K and Br are present only in the smallest particles. Copyright © 2004 John Wiley & Sons, Ltd.  相似文献   

3.
The aim of this study was to determine and evaluate the temporal profiles of the concentration of chemical elements in the suspended particulate matter present inside a small bronze and an iron foundry industry. To collect the samples, we used a streaker sampler that separates particles with aerodynamic diameters smaller than 10 µm (PM10) in two fractions: fine (particles with aerodynamic diameters less than 2.5 µm; PM2.5) and coarse (between 2.5 µm and less than 10 µm; PM10–2.5). The collection of samples was taken every 20 min during a total time of 8 and 5 h of molding and casting of bronze and iron, respectively. The samples collected in the form of strips on a filter (fine fraction) and an impactor (coarse fraction) were analyzed by the energy dispersive X‐ray fluorescence technique. In the excitation, an X‐ray tube with Mo target and Zr filter was used, operated at 30 mA/30 kV. For detecting the characteristic of X‐rays, a semiconductor Si(Li) detector was used, coupled to a multi‐channel spectrometer, with a 300 s excitation/detection time. The results of the temporal profiles of chemical element concentrations in coarse and fine fractions were discussed and compared with the maximum levels set by the Brazilian and international environmental agencies. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

4.
Particulate matter is an important air pollutant, especially in closed environments like a tunnel. The aim of this study was to determine the mass, black carbon, and elemental concentrations of particulate matter of two size fractions at an underground tram station in Hammarkullen, Gothenburg, Sweden. Samples were collected during June 2007 using a dichotomous virtual impactor separating the sampled aerosol particles into coarse (PM(2.5–10)) and fine (PM2.5) fractions. To minimize the possible influence of waiting passengers, the platform for trams going towards the suburb Angered was chosen. The elemental analysis of the samples, collected on Teflon filters, was carried out using energy dispersive x‐ray fluorescence (EDXRF) spectrometry, resulting in concentrations of 14 elements in most of the samples. Principal component analysis (PCA) was applied to identify possible sources for the elements in the particles. Owing to the tunnel environment, the elemental difference between the fine and coarse particle fractions was not as large as that in similar particles collected under normal outdoor ambient conditions. Likewise, the influence of the local weather situation was not significant. Particle content from the tram traffic was identified by PCA, with Fe being the major element in both coarse and fine particles. The particle mass concentration was higher in the tunnel compared to the ambient concentration at the monitoring station Femman in downtown Gothenburg. In some days, the mass concentration exceeded the Swedish daily ambient air quality standard of 50 µg m?3, but it was lower than the limits in the environmental work act, 5 mg m?3. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

5.
Small aerosol particles have for a long time been known to be harmful to humans, and are today regarded to cause a larger number of deaths than traffic accidents globally. Energy dispersive x‐ray fluorescence (EDXRF) is a well known method that has been used for identification of toxic as well as non‐toxic elements in the particles. The combination of elements will together with other information help to identify the sources and predict the effects of particles on environment and human health. The present work was conducted in Kwabenya, a suburb of the capital Accra of Ghana, which is frequently exposed to Harmattan dust from the Sahara–Sahel region. In total 171 filters each of PM2.5 and PM(2.5–10) were collected during 1 year. Levels of elements, black carbon (BC) and mass, were determined for both particle sizes. Principal component analysis (PCA) was performed on the datasets from Harmattan and non‐Harmattan periods. The daily average of PM10 was very high, 179 µg m?3 and the BC contents were 4 µg m?3. The presence of crustal elements was large in PM(2.5–10) as well as in PM2.5, and had a more than tenfold increase in PM(2.5–10) during the Harmattan period. Major characteristic elements for different sources were identified from correlation coefficients and regression analysis of the data. Sahara sand aerosol was the major source in both study periods, but influence from biomass burning, sea‐spray and metal industries was also observed. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

6.
The aim of the study was to determine the mass, black carbon (BC), and elemental concentrations in fine particles (PM2.5) and their variations at two sites in Ouagadougou, the capital city of Burkina Faso. The weather situation in Ouagadougou during the field campaign was dominated by high pressure with variable cloudiness and no precipitation. Diurnal temperatures varied between 19 and 38 °C and relative humidity between 10 and 60%. Winds in Ouagadougou were generally coming in from the north, showing a diurnal pattern with gusts of up to 6 m/s during daytime, while evenings and nights were calmer with very stable atmospheric conditions. However, during part of this field campaign, a period of nighttime moderately stable atmospheric conditions occurred with increased wind speed and more easterly winds. Cyclones were used for the PM2.5 particle collection at both sites. The elemental analysis was done using energy dispersive x‐ray fluorescence (EDXRF) spectroscopy. Cl, K, Ca, Ti, Mn, Fe, Cu, Zn, Br, Rb, Sr, and Pb were identified and quantified in most of the samples. The particle mass concentration was 27–164 µg/m3 while BC varied between 1.3 and 8.2 µg/m3. No influence of leaded gasoline was found. Soil dust was identified as a major component of the particles, which was confirmed by comparing with the elements in a soil sample. A significant difference in elemental, BC, and mass concentrations was seen between periods with very stable and moderately stable atmospheric conditions. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

7.
Makkah city, Saudi Arabia, represents the most attractive place for religious tourism for Muslims all over the world. More than 15 million visitors come to the city per year, especially during Hajj (pilgrimage) and Ramadan seasons. Due to the lack of air quality assessment data for Makkah, measurement of different pollutants in Makkah is of great interest. In the present work, airborne particulate matter with aerodynamic diameter equal to or less than 2.5 µm (PM2.5) has been collected from two different sites in the city, namely the Grand mosque and Al‐Shraie, from December 2012 to January 2014 covering the different seasons of the year. The average mass concentrations at the sites are comparable, 48 ± 28 µg/m3 and 53 ± 27 µg/m3 for the Grand mosque and Al‐Shraie sites, respectively. For quantitative elemental analysis, energy dispersive X‐ray fluorescence (EDXRF) spectrometry was used. Twenty elements (Si, S, Cl, K, Ca, Sc, Ti, V, Cr, Mn, Fe, Ni, Cu, Zn, Ga, Se, Br, Rb, Sr and Pb) were quantified in the PM2.5 samples. Fortunately, the obtained results of Pb and S are below the maximum allowance level of European commission for air quality. However, the average concentration of Ni in both sites is close to the maximum allowance level 20 ng/m3 and the Ni concentration reaches 25 ng/m3 at Grand mosque site during August 2013. Based on the Positive Matrix Factorization (PMF) analysis, four source factors were found, some signalling mixed sources, showing the main influence from mineral dust, anthropogenic/industrial sources and a marine source. Copyright © 2017 John Wiley & Sons, Ltd.  相似文献   

8.
Aerosol samples were collected at an urban background site in Skopje, Former Yugoslavic Republic of Macedonia, during four measurement campaigns from December 2006 to October 2007. An impactor was used to collect particulate matter (PM2.5) aerosol particles and the samples were analyzed for the concentrations of particulate mass, black carbon (BC), and 17 elements. The 12‐h average PM2.5 concentrations varied in the range 10–140 µg m?3 with the highest concentrations measured during wintertime pollution episodes and during the summer period. Pair‐wise correlations and crustal enrichment were studied and the data set was analyzed by factor analysis and positive matrix factorization. Major aerosol components were identified as mineral dust (main observed tracers Si, K, Ca, Ti, Fe, Sr, and Rb), combustion (BC, S, K, V, and Ni), traffic‐related aerosol (Pb and Zn), and secondary sulfate combined with mineral dust. Combustion sources dominated during wintertime and were likely due to heavy oil combustion, biomass burning, and other industrial activities within the city area. Mineral dust was observed throughout the year, but the concentrations peaked during the unusually hot and dry summer of 2007. It is concluded that Skopje suffers from serious air pollution due to central and residential heating, the transport sector, and industrial activities within the city, and contributions from mineral dust increase the PM2.5 concentrations under dry periods. Topography and meteorological conditions aggravate the problems and make the air quality comparable with the conditions in other highly polluted cities in Southern Europe and worldwide. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

9.
We applied proton microbeam particle‐induced X‐ray emission (µ‐PIXE) for mapping Ca, Zr, Ba and Yb, and atomic force microscopy (AFM) for imaging the surface landscape of a dental composite which releases Ca2+ and F? for the protection of hard dental tissues. Three areas ~250 × 250 µm2 located ~0.5–2 mm apart on a smooth surface specimen were mapped with 3.1 MeV protons focused to a ~3.0 µm spot and at ~3.9 µm pixel size sampling. The maps evidenced particles with diameters of 3.2–32 µm (Ca), 20–60 µm (Zr), ≤ 4 µm (Ba) and 10–50 µm (Yb). Cross‐section area histograms of Ca‐rich particles fitted with 2–6 Poisson functions revealed a polydisperse size distribution and substantial differences from an area to another, possibly implying large local variations of Ca2+ released in the hard tissue near a dental filling of a few millimeters in diameter. Such imbalances may lead to low local Ca2+ protection of the dental tissue, favoring the onset of secondary caries. Similarly, AFM images showed high zone‐dependent differences in the distributions of grains with apparent diameters of 1–4 µm, plausibly recognized as Ca‐ and Ba‐containing particles. In a simple model based on demineralization data, lateral diffusion of Ca2+ between adjacent domains containing high‐ and low‐area Ca‐rich grains is described by exponential concentration gradients. These gradients may generate appreciable electromotive forces, which may enhance electrochemically the local tissue demineralization. Similar effects are to be expected in the protective action of F? ions released from microgranules of YbF3 and of Ba fluoroaluminosilicate glass. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

10.
Rock‐shelter paintings of Bhimbetka world‐heritage site near Bhopal, India have been investigated using a portable Raman spectrometer. These paintings in the rock shelters belong to periods starting from pre‐historic to the 19th century AD (Gond period). In addition, tiny fragments of pigments (100–200 µm in size) extracted from some of the artworks were also studied in laboratory using a micro‐Raman spectrometer and analyzed using energy‐dispersive X‐ray analysis for elemental composition. Based on the Raman spectra and the elemental analysis mineral‐based pigments such as calcite, gypsum, hematite, whewellite, and goethite could be identified. A comparison of the spectra recorded on‐site using a light‐weight portable spectrometer with those using laboratory equipment is also made and discussed. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

11.
Laboratory-scale experiments pertinent to pulverised fuel (PF) combustion are often carried out in drop-tube furnaces (DTFs) at air-fuel equivalence ratios and cooling rate for quenching flue gas that are much higher than those in PF boilers. This paper reports the effect of flue gas cooling conditions on the properties of PM with aerodynamic diameter of <10 µm (PM10) from biomass combustion. This study considers four cooling rates (1000, 2000, 6000 and 20,000 °C/s) and two biomass feeding rates (0.05 and 0.25 g/min) that represents flue gases with significantly-different concentrations of inorganic vapours. The PSDs of PM10 have a bimodal distribution with a fine mode within PM with aerodynamic diameter of <1 µm (PM1) and a coarse mode within PM with aerodynamic diameter of 1–10 µm (PM1–10). All experimental conditions produce PM10 with similar PM1 and PM1–10 yields (~0.8 and ~1.6 mg/g_biomass, respectively) and similar coarse mode diameters (i.e. 6.863 µm). However, at a biomass feeding rate of 0.05 g/min, the fine mode diameter shifts from 0.022 to 0.077 µm when the cooling rate decreases from 20,000 to 1000 °C/s, indicating more profound heterogeneous condensation at a lower cooling rate. As the biomass feeding rate increases to 0.25 g/min, the fine mode diameter further shifts to 0.043 µm and at 20,000 °C/s but remained at 0.077 µm at 1000 °C/s though a clear shift of PSD to larger diameters is evident. These are attributed to enhanced heterogeneous condensation and coagulation of small particulates resulting from increased particle population density in hot flue gas. Chemical analyses show PM1 contains dominantly volatile elements (i.e. Na, K and Cl) while PM1–10 consists of mainly Ca. Similar trends are also observed for elemental PSDs and yields. It is also observed that slow cooling of hot flue gas leads to an increased yield of Cl in PM1–10 due to enhanced chlorination of Ca species.  相似文献   

12.
Workplace exposure to nanoparticles from gas metal arc welding (GMAW) process in an automobile manufacturing factory was investigated using a combination of multiple metrics and a comparison with background particles. The number concentration (NC), lung-deposited surface area concentration (SAC), estimated SAC and mass concentration (MC) of nanoparticles produced from the GMAW process were significantly higher than those of background particles before welding (P < 0.01). A bimodal size distribution by mass for welding particles with two peak values (i.e., 10,000–18,000 and 560–320 nm) and a unimodal size distribution by number with 190.7-nm mode size or 154.9-nm geometric size were observed. Nanoparticles by number comprised 60.7 % of particles, whereas nanoparticles by mass only accounted for 18.2 % of the total particles. The morphology of welding particles was dominated by the formation of chain-like agglomerates of primary particles. The metal composition of these welding particles consisted primarily of Fe, Mn, and Zn. The size distribution, morphology, and elemental compositions of welding particles were significantly different from background particles. Working activities, sampling distances from the source, air velocity, engineering control measures, and background particles in working places had significant influences on concentrations of airborne nanoparticle. In addition, SAC showed a high correlation with NC and a relatively low correlation with MC. These findings indicate that the GMAW process is able to generate significant levels of nanoparticles. It is recommended that a combination of multiple metrics is measured as part of a well-designed sampling strategy for airborne nanoparticles. Key exposure factors, such as particle agglomeration/aggregation, background particles, working activities, temporal and spatial distributions of the particles, air velocity, engineering control measures, should be investigated when measuring workplace exposure to nanoparticles.  相似文献   

13.
《X射线光谱测定》2005,34(6):493-497
Scanning electron microscopes are usually equipped with energy‐dispersive X‐ray detectors for electron probe microanalysis. This widespread analytical method allows investigators to determine the elemental composition of specimens with a spatial resolution of about 1 µm. However, owing to the electron–specimen interaction, the emitted spectra reveal, in addition to characteristic lines, also a high level of continuous bremsstrahlung background. As a result, elements with low concentrations cannot be identified. The minimum detection limit can be diminished by two orders of magnitude if the characteristic lines are excited as fluorescence by an additional x‐ray source. In this case, the emergence of bremsstrahlung is considerably reduced. Combining a high‐brilliance microfocus x‐ray tube with efficient polycapillary optics enables one to realize an experimental arrangement for performing local fluorescence analysis at the same point where the electron beam hits the sample. The polycapillary optics under consideration focuses the emitted x‐radiation onto focal spots between 30 and 100 µm in diameter. Count rates of several thousands cps have been achieved. Elemental maps have been obtained by means of the motorized specimen stage of the microscope. Copyright © 2005 John Wiley & Sons, Ltd.  相似文献   

14.
The high‐brilliance X‐ray beams from undulator sources at third‐generation synchrotron facilities are excellent tools for solving crystal structures of important and challenging biological macromolecules and complexes. However, many of the most important structural targets yield crystals that are too small or too inhomogeneous for a `standard' beam from an undulator source, ~25–50 µm (FWHM) in the vertical and 50–100 µm in the horizontal direction. Although many synchrotron facilities have microfocus beamlines for other applications, this capability for macromolecular crystallography was pioneered at ID‐13 of the ESRF. The National Institute of General Medical Sciences and National Cancer Institute Collaborative Access Team (GM/CA‐CAT) dual canted undulator beamlines at the APS deliver high‐intensity focused beams with a minimum focal size of 20 µm × 65 µm at the sample position. To meet growing user demand for beams to study samples of 10 µm or less, a `mini‐beam' apparatus was developed that conditions the focused beam to either 5 µm or 10 µm (FWHM) diameter with high intensity. The mini‐beam has a symmetric Gaussian shape in both the horizontal and vertical directions, and reduces the vertical divergence of the focused beam by 25%. Significant reduction in background was achieved by implementation of both forward‐ and back‐scatter guards. A unique triple‐collimator apparatus, which has been in routine use on both undulator beamlines since February 2008, allows users to rapidly interchange the focused beam and conditioned mini‐beams of two sizes with a single mouse click. The device and the beam are stable over many hours of routine operation. The rapid‐exchange capability has greatly facilitated sample screening and resulted in several structures that could not have been obtained with the larger focused beam.  相似文献   

15.
The aim of the work was to develop a Monte Carlo (MC) method and combine it with micro‐beam X‐ray fluorescence (XRF) technique for determination of chemical composition of individual particles. A collection of glass micro‐spheres, made of NIST (National Institute of Standards and Technoly) K3089 material of known chemical composition, with diameters in the range of 25–45 µm was investigated. The micro‐spheres were measured in a scanning micro‐beam XRF spectrometer utilising X‐ray tube as a source of primary radiation. Results obtained for low Z elements showed high dependence on particle size. It was found that the root mean square of concentration uncertainty, for the all elements present in the particle, increases with growing sample size. More accurate results were obtained for high Z elements such as Fe–Pb, as compared to others. The elemental percentage uncertainty did not exceed 14% for any particular sample and 6% for the whole group of the measured micro‐spheres as an average. Results obtained by the Monte Carlo method were compared with other analytical approaches. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

16.
This study proposes simple techniques involving the use of a thin wire set close to the sample surface to measure the elemental depth distribution in microbeam X‐ray fluorescence analysis. One is the X‐ray fluorescence detection in energy‐dispersive mode using a solid‐state detector in combination with the sample movement, and the other is in projection mode using an X‐ray charge‐coupled device camera. The minimum depth resolution (spatial resolution) obtained with a thin Mo wire is about 15 µm. Compared with a confocal depth‐profiling method, wire depth‐profile analysis is easy to implement, flexible, and has reasonable sensitivity. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

17.
A semiconductor device, a microSD card, was measured by using two XRF instruments. 2D elemental images were obtained using a micro‐XRF system with a spatial resolution of 10 µm. Elemental distributions of the near‐surface region of the sample were clearly shown. Titanium was observed in the resin constituting the sample. Nickel and gold were observed on a terminal and localization of the sample. Elemental distribution of copper reflected the circuit structure of the measurement area that was in the neighborhood of the sample surface. Moreover, the elemental depth distributions of the sample were measured by using a confocal micro‐XRF instrument. The confocal micro‐XRF instrument was constructed in the laboratory with fine‐focus polycapillary x‐ray optics. The depth resolution of the developed spectrometer was 13.7 µm at an energy of Au Lβ (11.4 keV). The elemental images obtained at near‐surface by confocal micro‐XRF were the same as the results obtained from 2D micro‐XRF. However, different Cu images were obtained at a depth of several tens of micrometers. This indicates that microSD cards consist of a few different Cu‐circuit structure designs. The elemental depth distributions of each circuit structure of the semiconductor device were clearly shown by confocal micro‐XRF. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

18.
Inhalation exposure to airborne nanoparticles (NPs) has been reported during manual activities using typical fume hoods. This research studied potential inhalation exposure associated with the manual handling of NPs using two new nanoparticle-handling enclosures and two biological safety cabinets, and discussed the ability to contain NPs in the hoods to reduce environmental release and exposure. Airborne concentrations of 5 nm to 20 μm diameter particles were measured while handling nanoalumina particles in various ventilated enclosures. Tests were conducted using two handling conditions and concentrations were measured using real-time particle counters, and particles were collected on transmission electron microscope grids to determine particle morphology and elemental composition. Airflow patterns were characterized visually using a laser-light sheet and fog. The average number concentration increase at breathing zone outside the enclosure was less than 1,400 particle/cm3 for each particle size at all tested conditions and the estimated overall mass concentration was about 83 μg/m3 which was less than the dosage of typical nanoparticle inhalation exposure studies. The typical front-to-back airflow was used in the studied hoods, which could potentially induce reverse turbulence in the wake region. However, containment of NPs using studied hoods was demonstrated with excellent performance. Smoke tests showed that worker’s hand motion could potentially cause nanoparticle escape. The challenge of front-to-back airflow can be partially overcome by gentle motion, low face velocity, and front exhaust to reduce nanoparticle escape.  相似文献   

19.
BioCARS, a NIH‐supported national user facility for macromolecular time‐resolved X‐ray crystallography at the Advanced Photon Source (APS), has recently completed commissioning of an upgraded undulator‐based beamline optimized for single‐shot laser‐pump X‐ray‐probe measurements with time resolution as short as 100 ps. The source consists of two in‐line undulators with periods of 23 and 27 mm that together provide high‐flux pink‐beam capability at 12 keV as well as first‐harmonic coverage from 6.8 to 19 keV. A high‐heat‐load chopper reduces the average power load on downstream components, thereby preserving the surface figure of a Kirkpatrick–Baez mirror system capable of focusing the X‐ray beam to a spot size of 90 µm horizontal by 20 µm vertical. A high‐speed chopper isolates single X‐ray pulses at 1 kHz in both hybrid and 24‐bunch modes of the APS storage ring. In hybrid mode each isolated X‐ray pulse delivers up to ~4 × 1010 photons to the sample, thereby achieving a time‐averaged flux approaching that of fourth‐generation X‐FEL sources. A new high‐power picosecond laser system delivers pulses tunable over the wavelength range 450–2000 nm. These pulses are synchronized to the storage‐ring RF clock with long‐term stability better than 10 ps RMS. Monochromatic experimental capability with Biosafety Level 3 certification has been retained.  相似文献   

20.
A focusing system based on a polycapillary half‐lens optic has been successfully tested for transmission and fluorescence µ‐X‐ray absorption spectroscopy at a third‐generation bending‐magnet beamline equipped with a non‐fixed‐exit Si(111) monochromator. The vertical positional variations of the X‐ray beam owing to the use of a non‐fixed‐exit monochromator were shown to pose only a limited problem by using the polycapillary optic. The expected height variation for an EXAFS scan around the Fe K‐edge is approximately 200 µm on the lens input side and this was reduced to ~1 µm for the focused beam. Beam sizes (FWHM) of 12–16 µm, transmission efficiencies of 25–45% and intensity gain factors, compared with the non‐focused beam, of about 2000 were obtained in the 7–14 keV energy range for an incoming beam of 0.5 × 2 mm (vertical × horizontal). As a practical application, an As K‐edge µ‐XANES study of cucumber root and hypocotyl was performed to determine the As oxidation state in the different plant parts and to identify a possible metabolic conversion by the plant.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏