首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
The aim of this study was to investigate the inertial cavitation inside a phantom treated by pulsed HIFU (pHIFU). Basic bovine serum albumin (BSA) phantoms without any inherent ultrasound contrast agents (UCAs) or phase-shift nano-emulsions (PSNEs) were used. During the treatment, sonoluminescence (SL) recordings were performed to characterize the spatial distribution of inertial cavitation adjacent to the focal region. High-speed photographs and thermal coagulations, comparing with the SL results, were also recorded and presented. A series of pulse parameters (pulse duration (PD) was between 1 and 23 cycles and pulse repetition frequency (PRF) was between 0.5 kHz and 100 kHz) were performed to make a systematic investigation under certain acoustic power (APW). Continuous HIFU (cHIFU) investigation was also performed to serve as control group. It was found that, when APW was 19.5 W, pHIFU with short PD was much easier to form SL adjacent to the focal region inside the phantom, while it was difficult for cHIFU to generate cavitation bubbles. With appropriate PD and PRF, the residual bubbles of the previous pulses could be stimulated by the incident pulses to oscillate in a higher level and even violently collapse, resulting to enhanced physical thermogenesis. The experimental results showed that the most violent inertial cavitation occurs when PD was set to 6 cycles (5 μs) and PRF to 10 kHz, while the highest level of thermal coagulation was observed when PD was set to 10 cycles. The cavitational and thermal characteristics were in good correspondence, exhibiting significant potentiality regarding to inject-free cavitation bubble enhanced thermal ablation under lower APW, compared to the conventional thermotherapy.  相似文献   

2.
本文使用双束同频脉冲超声水平正交辐照,通过磺释放法检测,发现双束同频水平正交辐照亦可观察到明显的空化峰现象及声化学产额增长。  相似文献   

3.
Quantitative experimental observations of single-bubble cavitation in viscoelastic media that would enable validation of existing models are presently lacking. In the present work, single bubble cavitation is induced in an agar gel using a 1.15 MHz high intensity focused ultrasound transducer, and observed using a focused single-element passive cavitation detection (PCD) transducer. To enable quantitative observations, a full receive calibration is carried out of a spherically focused PCD system by a bistatic scattering substitution technique that uses an embedded spherical scatterer and a hydrophone. Adjusting the simulated pressure received by the PCD by the transfer function on receive and the frequency-dependent attenuation of agar gel enables direct comparison of the measured acoustic emissions with those predicted by numerical modeling of single-bubble cavitation using a modified Keller-Miksis approach that accounts for viscoelasticity of the surrounding medium. At an incident peak rarefactional pressure near the cavitation threshold, period multiplying is observed in both experiment and numerical model. By comparing the two sets of results, an estimate of the equilibrium bubble radius in the experimental observations can be made, with potential for extension to material parameter estimation. Use of these estimates yields good agreement between model and experiment.  相似文献   

4.
Nowadays, both thermal and mechanical ablation techniques of HIFU associated with cavitation have been developed for noninvasive treatment. A specific challenge for the successful clinical implementation of HIFU is to achieve real-time imaging for the evaluation and determination of therapy outcomes such as necrosis or homogenization. Ultrasound Nakagami-m parametric imaging highlights the degrading shadowing effects of bubbles and can be used for tissue characterization. The aim of this study is to investigate the performance of Nakagami-m parametric imaging for evaluating and differentiating thermal coagulation and cavitation erosion induced by HIFU. Lesions were induced in basic bovine serum albumin (BSA) phantoms and ex vivo porcine livers using a 1.6 MHz single-element transducer. Thermal and mechanical lesions induced by two types of HIFU sequences respectively were evaluated using Nakagami-m parametric imaging and ultrasound B-mode imaging. The lesion sizes estimated using Nakagami-m parametric imaging technique were all closer to the actual sizes than those of B-mode imaging. The p-value obtained from the t-test between the mean m values of thermal coagulation and cavitation erosion was smaller than 0.05, demonstrating that the m values of thermal lesions were significantly different from that of mechanical lesions, which was confirmed by ex vivo experiments and histologic examination showed that different changes result from HIFU exposure, one of tissue dehydration resulting from the thermal effect, and the other of tissue homogenate resulting from mechanical effect. This study demonstrated that Nakagami-m parametric imaging is a potential real-time imaging technique for evaluating and differentiating thermal coagulation and cavitation erosion.  相似文献   

5.
The use of cavitation for improving biofilm cleaning is of great interest. There is no system at present that removes the biofilm from medical implants effectively and specifically from dental implants. Cavitation generated by a vibrating dental ultrasonic scaler tip can clean biomaterials such as dental implants. However, the cleaning process must be significantly accelerated for clinical applications. In this study we investigated whether the cavitation could be increased, by operating the scaler in carbonated water with different CO2 concentrations. The cavitation around an ultrasonic scaler tip was recorded with high speed imaging. Image analysis was used to calculate the area of cavitation. Bacterial biofilm was grown on surfaces and its removal was imaged with a high speed camera using the ultrasonic scaler in still and carbonated water. Cavitation increases significantly with increasing carbonation. Cavitation also started earlier around the tips when they were in carbonated water compared to non-carbonated water. Significantly more biofilm was removed when the scaler was operated in carbonated water. Our results suggest that using carbonated water could significantly increase and accelerate cavitation around ultrasonic scalers in a clinical situation and thus improve biofilm removal from dental implants and other biomaterials.  相似文献   

6.
The study of cavitation inception in liquids rarely yields reproducible data, unless special control is taken on the cleanliness of the experimental environment. In this paper, an experimental technique is demonstrated which allows repeatable measurements of cavitation activity in liquid-particle suspensions. In addition, the method is noninvasive: cavitation bubbles are generated using a shock-wave generator, and they are photographed using a digital camera. The cavitation activity is obtained after suitable image processing steps. From these measurements, the importance of the particle's surface structure and its chemical composition is revealed, with polystyrene and polyamide particles generating the highest yields. Further findings are that cavitation nuclei become depleted with an increasing number of experiments, and the existence of nuclei with varying negative pressure thresholds. Finally, a decrease of the cavitation yield is achieved by prepressurization of the suspension-indicating that the cavitation nuclei are gaseous.  相似文献   

7.
提出一种采用B超图像实现高强聚焦超声(HIFU)治疗时声空化的时空量化监控的方法。首先,采用B模式实时成像系统对不同声辐照能量下的HIFU在凝胶仿体中引发的超声空化进行实验监测;接着,利用二维数字图像处理算法消除高强聚焦超声(HIFU)在B超图像中产生的干涉条纹,并在此基础上,对B超成像中观察到的高亮区域的面积变化情况进行量化分析;最后,进一步讨论了驱动声压或脉冲宽度对超声空化产生的高亮区域的生成速度和面积大小的影响。结果显示该方法可以有效去除B超图像中的干涉条纹,并对HIFU引发的空化现象进行实时监测。实验结果还表明辐照声能量的提高将引发更强烈的声空化行为,并且显著缩短HIFU引发的空化泡群的初始生成时间。研究结果对进一步优化HIFU治疗有重要意义。  相似文献   

8.
陈楚怡  于洁  陈功  马勇  郭霞生  屠娟  章东 《声学学报》2015,40(4):563-568
提出一种采用B超图像实现高强聚焦超声(HIFU)治疗时声空化的时空量化监控的方法。首先,采用B模式实时成像系统对不同声辐照能量下的HIFU在凝胶仿体中引发的超声空化进行实验监测;接着,利用二维数字图像处理算法消除高强聚焦超声(HIFU)在B超图像中产生的干涉条纹,并在此基础上,对B超成像中观察到的高亮区域的面积变化情况进行量化分析;最后,进一步讨论了驱动声压或脉冲宽度对超声空化产生的高亮区域的生成速度和面积大小的影响。结果显示该方法可以有效去除B超图像中的干涉条纹,并对HIFU引发的空化现象进行实时监测。实验结果还表明辐照声能量的提高将引发更强烈的声空化行为,并且显著缩短HIFU引发的空化泡群的初始生成时间。研究结果对进一步优化HIFU治疗有重要意义。  相似文献   

9.
To understand the behaviour of systems containing clouds of bubbles (multibubble system) in real sonochemical reactors, a new diagnosis method, i.e., optical cavitation probe (OCP), has been proposed. When a laser beam is introduced into the cavitation bubble cloud, the scattered light intensity changes by the collective oscillation of cavitation bubbles. The frequency domain spectrum of the scattered light contains rich information on the cavitation bubble clouds, comparable with the acoustic emission spectra detected by a hydrophone. The significant merits of OCP, such as capability for spatially resolved, non-invasive measurement of the cavitation bubble clouds, robustness even in a violent cavitation field have been experimentally demonstrated.  相似文献   

10.
The primary purpose of this study is to investigate the effects of hydrodynamic and acoustic cavitation (HAC) on the leaching efficiency of tungsten. The aim is to reduce energy use and to improve the recovery rate. The goal is also to carry out a leaching process at a much lower temperature than in an autoclave process that is currently used in the industry. Energy-efficient initiation and collapse of cavitation bubbles require optimization of (i) vibro-acoustic response of the reactor structure, (ii) multiple excitation frequencies adapted to the optimized reactor geometry, and (iii) hydrodynamic cavitation with respect to orifice geometry and flow conditions. The objective is to modify and apply a previously in house developed high power cavitation reactor in order to recover tungsten by leaching of the dissolution of scheelite in sodium hydroxide. In this process, various experimental conditions like dual-frequency excitation, different orifice geometry have been investigated. The numerically optimized reactor concept was excited by two frequencies 23 kHz and 3943 kHz in various flow conditions. The effects of leaching time, leaching temperature, ultrasonic power and geometry of orifice plates have been studied. The leaching temperature was varied from 40 °C to 80 °C. The concentration of leaching reagent sodium hydroxide (NaOH) was 10 mol/L.The results were compared to conventional chemical leaching. Energy supplement with acoustic cavitation of 130 kWh/kg concentrate resulted in a leaching recovery of tungsten (WO3) of 71.5%, compared to 36.7% obtained in absence of ultrasound. The results confirm that the method developed is energy efficient and gives a recovery rate potentially better than current autoclave technology.  相似文献   

11.
Stable cavitation (SC) has shown great potential for novel therapeutic applications. The spatiotemporal distribution of the SC activity of microbubbles circulating in a target region is not only correlated with the uniformity of treatment, but also with some undesirable effects. Therefore, it is important to achieve controllable and desirable SC activity in target regions for improved therapeutic efficiency and biosafety. This study proposes a closed-loop feedback controller based on pulse length (PL) regulation to improve the temporal stability of SC activity. Microbubbles circulating in a physiological flowing phantom were exposed to a 1 MHz focused transducer. The SC signals produced were initially received by another 7.5 MHz plane transducer, followed by high-speed signal acquisition and real-time processing. Based on the real-time-measured SC intensity excited by the current acoustic pulse, the proposed closed-loop feedback controller used three proportional coefficients to regulate the peak negative pressure (PNP) and PL of the next acoustic pulse during the acceleration and stable stages, respectively. The results show that the rise time and the temporal stability of the SC intensity of the microbubbles circulating in these two stages were improved significantly by the optimized proportional coefficients used in the proposed controller. Importantly, when compared with the traditional closed-loop feedback controller based on PNP regulation, the proposed closed-loop feedback controller based on PL regulation reduced the probability of a transition between stable and inertial cavitation, thus avoiding the risk of disadvantageous bioeffects in practical applications. These results demonstrate the effectiveness of the proposed PL-based closed-loop feedback controller and provide a feasible strategy for realization of controllable cavitation activity in applications.  相似文献   

12.
The present study reports significant improvements in the removal of ammoniacal nitrogen from wastewater which is an important problem for many industries such as dyes and pigment, distilleries and fisheries. Pilot plant studies (capacity, 1 m3/h) on synthetic wastewater using 4-amino phenol as model nitrogen containing organic compound and two real industrial effluents of high ammoniacal nitrogen content were carried out using hydrodynamic cavitation. Two reactor geometries were evaluated for increased efficiency in removal-orifice and vortex diode. Effect of initial concentration (100–500 mg/L), effect of pressure drop (0.5–5 bar) and nature of cavitating device (linear and vortex flow for cavitation) were evaluated along with effect of salt content, effect of hydrogen peroxide addition and aeration. Initial concentration was found to have significant impact on the extent of removal: ~ 5 g/m3 removal for initial concentration of 100 mg/L and up to 12 g/m3 removal at high concentration of 500 mg/L. Interestingly, significant improvement of the order of magnitude (up to 8 times) in removal of ammoniacal nitrogen could be obtained by sparging air or oxygen in hydrodynamic cavitation and a very high removal of above 80% could be achieved. The removal of ammoniacal nitrogen by vortex diode was also found to be effective in the industrial wastewaters and results on two different effluent samples of distillery industry indicated up to 75% removal, though with longer time of treatment compared to that of synthetic wastewater. The developed methodology of hydrodynamic cavitation technology with aeration and vortex diode as a cavitating device was found to be highly effective for improving the efficiency of the conventional cavitation methods and hence can be highly useful in industrial wastewater treatment, specifically for the removal of ammoniacal nitrogen.  相似文献   

13.
Macroalgae have a tremendous potential to become an important renewable resource for valuable biomolecules and chemicals. New and improved ways of cell disruption and of enhancing rate as well as yield of extraction of valuable products from macroalgae are needed to fully realise this potential. In this work, hydrodynamic cavitation (HC) was used for intensifying rate and yield of extraction of phycoerythrin, proteins and carbohydrates from marine macroalgae Palmaria palmata. We use vortex-based HC devices which do not use small restrictions like orifice-based HC devices or moving parts like rotor–stator based HC devices. A bench scale setup with a nominal slurry flow rate of 20 LPM was established. Dried and powdered macroalgae was used. Influence of key operating parameters like pressure drop and number of passes on extraction performance (the rate and yield) was measured. A simple, yet effective model was developed and used for interpreting and describing experimental data. The results indicate that there exists an optimum pressure drop across the device at which extraction performance is maximum. The extraction performance with HC was found to be significantly better than the stirred vessels. HC has resulted in 2 to 20 times improvement in the rate of extraction of phycoerythrin (R-PE), proteins and carbohydrates. Based on the results obtained in this work, pressure drop of 200 kPa and number of passes through the HC devices of about 100 were found to be most effective for HC-assisted intensified extraction from macroalgae. The presented results and model will be useful for harnessing vortex-based HC devices for intensifying the extraction of valuable products from macroalgae.  相似文献   

14.
Investigations have been performed on various methods of increasing cavitation activity measured by the intensity of sonoluminescence. It is shown that the effect of the combined action of (a) pulsed modulation of an acoustic field, (b) liquid degassing and cooling and (c) increasing the static pressure considerably exceeds the sum of the effects achieved by each of these methods individually. A more than 250-fold increase of the sonoluminescence intensity has been attained compared with continuous irradiation under normal conditions (room temperature, atmospheric pressure, gas-saturated liquid). An interpretation of the results obtained is proposed.  相似文献   

15.
应用高光谱仪探测叶片反射光谱中的荧光   总被引:1,自引:0,他引:1  
介绍了一种利用光谱仪进行荧光测量的方法。采用LI 1800_12S积分球,耦合ASD地物光谱仪,在光源前面分别加载长波通、短波通截止滤光片,按照不同算法提取叶片表观反射光谱中的荧光。结果表明利用长波通滤光片测得的表观反射率差值光谱可以代表荧光光谱,在红光区和远红光区表现为明显的双峰特征,不同截止波长滤光片提取的荧光强度不同。采用短波通滤光片可直接获得荧光光谱,不同植物种类荧光光谱差异明显。此法对于植物被动荧光遥感探测及叶绿素荧光仪的研制和开发具有一定参考价值。  相似文献   

16.
17.
J. H. Todd 《Ultrasonics》1970,8(4):234-238
Decomposition of water by cavitation produces the same free radicals as ionizing radiations. Standard chemical dosimeters have been used to measure the chemical activity of cavitation, and to obtain an indirect determination of the relative yields of the primary products of the sonolysis of water. It is shown that the yields are dependent only upon the energy deposited, and are completely independent of the frequency, intensity or intensity distribution of the ultrasonic field, and also of the gas content of the solution. The cavitation bubbles are found to deposit chemical energy in a manner very similar to that of slow -particles.  相似文献   

18.
The present work demonstrates the application of a hydrodynamic cavitation reactor for the synthesis of biodiesel with used frying oil as a feedstock. The synthesis involved the transesterification of used frying oil (UFO) with methanol in the presence of potassium hydroxide as a catalyst. The effect of geometry and upstream pressure of a cavitating orifice plate on the rate of transesterification reaction has been studied. It is observed that the micro level turbulence created by hydrodynamic cavitation somewhat overcomes the mass transfer limitations for triphasic transesterification reaction. The significant effects of upstream pressure on the rate of formation of methyl esters have been seen. It has been observed that flow geometry of orifice plate plays a crucial role in process intensification. With an optimized plate geometry of 2 mm hole diameter and 25 holes, more than 95% of triglycerides have been converted to methyl esters in 10 min of reaction time with cavitational yield of 1.28 × 10?3 (Grams of methyl esters produced per Joule of energy supplied). The potential of UFO to produce good quality methyl esters has been demonstrated.  相似文献   

19.
20.
We quantitatively study cavitation damage non-invasively, in-place and time-resolved at microsecond resolution. A single, laser-induced bubble is generated in an aqueous NaCl solution close to the surface of an aluminum sample. High-speed chronoamperometry is used to record the corrosion current flowing between the sample and an identical aluminum electrode immersed in the same solution. This configuration makes it possible to measure the cavitation damage in the nanometer thin passive layer of the aluminum surface via the corrosion current from the repassivation. Synchronously with the corrosion current, the bubble dynamics is recorded via high-speed imaging. Correlation between the two measurements allows contributing cavitation damage to the respective stages of the bubble dynamics. The largest cavitation-induced currents were observed for the smallest initial bubble-to-surface stand-off distances. As the bubble re-expands and collapses again in several stages, further current peaks were detected implying a sequence of smaller damage. At intermediate stand-offs, the bubble was not damaging and at large stand-off distances, the bubble was only damaging during the second collapse which again occurs at the solid surface.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号