首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
2.
3.
Accurate isotope ratio measurements are of high importance in various scientific fields, ranging from radio isotope geochronology of solids to studies of element isotopes fractionated by living organisms. Instrument limitations, such as unresolved isobaric inferences in the mass spectra, or cosampling of the material of interest together with the matrix material may reduce the quality of isotope measurements. Here, we describe a method for accurate isotope ratio measurements using our laser ablation ionization time‐of‐flight mass spectrometer (LIMS) that is designed for in situ planetary research. The method is based on chemical depth profiling that allows for identifying micrometer scale inclusions embedded in surrounding rocks with different composition inside the bulk of the sample. The data used for precise isotope measurements are improved using a spectrum cleaning procedure that ensures removal of low quality spectra. Furthermore, correlation of isotopes of an element is used to identify and reject the data points that, for example, do not belong to the species of interest. The measurements were conducted using IR femtosecond laser irradiation focused on the sample surface to a spot size of ~12 μm. Material removal was conducted for a predefined number of laser shots, and time‐of‐flight mass spectra were recorded for each of the ablated layers. Measurements were conducted on NIST SRM 986 Ni isotope standard, trevorite mineral, and micrometer‐sized inclusions embedded in aragonite. Our measurements demonstrate that element isotope ratios can be measured with accuracies and precision at the permille level, exemplified by the analysis of B, Mg, and Ni element isotopes. The method applied will be used for in situ investigation of samples on planetary surfaces, for accurate quantification of element fractionation induced by, for example, past or present life or by geochemical processes.  相似文献   

4.
5.
In the field of isotope ratio mass spectrometry, the introduction of an interface allowing the connection of liquid chromatography (LC) and isotope ratio mass spectrometry (IRMS) has opened a range of new perspectives. The LC interface is based on a chemical oxidation, producing CO2 from organic molecules. While first results were obtained from the analysis of low molecular weight compounds, the application of compound-specific isotope analysis by irm-LC/MS to other molecules, in particular biomolecules, is presented here. The influence of the LC flow rate on the CO2 signal and on the observed delta13C values is demonstrated. The limits of quantification for angiotensin III and for leucine were 100 and 38 pmol, respectively, with a standard deviation of the delta13C values better than 0.4 per thousand. Also, accuracy and precision of delta13C values for elemental analyser-IRMS and flow injection analysis-IRMS (FIA-LC/MS) were compared. For compounds with molecular weights ranging from 131 to 66,390 Da, precision was better than 0.3 per thousand, and accuracy varied from 0.1 to 0.7 per thousand. In a second part of the work, a two-dimensional (2D)-LC method for the separation of 15 underivatised amino acids is demonstrated; the precision of delta13C values for several amino acids by irm-LC/MS was better than 0.3 per thousand at natural abundance. For labelled mixtures, the coefficient of variation was between 1% at 0.07 atom % excess (APE) for threonine and alanine, and around 10% at 0.03 APE for valine and phenylalanine. The application of irm-LC/MS to the determination of the isotopic enrichment of 13C-threonine in an extract of rat colon mucosa demonstrated a precision of 0.5 per thousand, or 0.001 atom %.  相似文献   

6.
We have demonstrated the feasibility of determining isotope ratios in very small samples of osmium by deuteron activation in the Livermore Tandem Van de Graaff accelerator. The method involves determination of cross-section ratios by using several osmium isotope mixtures carefully prepared from electromagnetically-enriched osmium isotopes. The accuracy of this method was checked by a determination of the isotope ratios in naturally-occurring osmium. Our analysis demonstrated that an osmium specimen removed from a sample of commercial grade perrhenic acid contained only 0.4% natural osmium, the rest being radiogenic187Os.Work performed under the auspices of the U. S. Department of Energy by the Lawrence Livermore National Laboratory under Contract W-7405-Eng-48.  相似文献   

7.
Two new procedures for wine ethanol 13C/12C isotope ratio determination, using high-performance liquid chromatography and gas chromatography isotope ratio mass spectrometry (HPLC/IRMS and GC/IRMS), have been developed to improve isotopic methods dedicated to the study of wine authenticity. Parameters influencing separation of ethanol from wine matrix such as column, temperature, mobile phase, flow rates and injection mode were investigated. Twenty-three wine samples from various origins were analyzed for validation of the procedures. The analytical precision was better than 0.15 per thousand, and no significant isotopic fractionation was observed employing both separative techniques coupled to IRMS. No significant differences and a very strong correlation (r = 0.99) were observed between the 13C/12C ratios obtained by the official method (elemental analyzer/isotope ratio mass spectrometry) and the proposed new methodology. The potential advantages of the developed methods over the traditional one are speed (reducing time required from hours to minutes) and simplicity. In addition, these are the first isotopic methods that allow 13C/12C determination directly from a liquid sample with no previous ethanol isolation, overcoming technical difficulties associated with sample treatment.  相似文献   

8.
Laser ablation has been combined with dual tunable diode laser absorption spectrometry to measure 152Gd:160Gd isotope ratios in micron-size particles. The diode lasers are tuned to specific isotopes in two different atomic transitions at 405.9 nm (152Gd) and 413.4 nm (160Gd) and directed collinearly through the laser ablation plume, separated on a diffraction grating, and detected with photodiodes to monitor transient absorption signals on a shot-by-shot basis. The method has been characterized first using Gd metal foil and then with particles of GdCl3·xH20 as binary and ternary mixtures with 152Gd:160Gd isotope ratios ranging from 0.01 to 0.43. These particulate mixtures have been diluted with Columbia River sediment powder (SRM 4350B) to simulate environmental samples and we show the method is capable of detecting a few highly-enriched particles in the presence of a >100-fold excess of low-enrichment particles, even when the Gd-bearing particles are a minor component (0.08%) in the SRM powder and widely dispersed (1178 particles detected in 800,000 ablation laser shots). The implications for monitoring 235U:238U enrichment ratios in airborne particle samples, as related to the nuclear industry, are discussed.  相似文献   

9.
Effects of surfactant/water volume ratios and dye amounts on the properties of micelles and fluorescence silica nanoparticles were studied in microemulsions containing nonionic surfactant Triton X-100, hexanol as co-surfactant, cyclohexane as organic solvent, and metal organic dye (tris(2,2′-bipyridyl)dichlororuthenium) via fluorescence probe technique, TEM, and XPS. Fluorescence probe measurements show that the micelle microenvironment becomes stable at the surfactant/water volume ratio higher than 3.5 and the incubation time longer than 10 h. The data suggest that the silica shell, which is formed at the surfactant/water ratio of 3.5, yields an efficient protection of dye molecules against the e-beam irradiation and result in high photostability of fluorescent silica. We pioneered the localization of dye molecules on the surface of dye-doped silica and found that an increase of dye amounts, beyond a threshold, in the microemulsion cannot enhance the fluorescence intensity of dye-doped nanoparticles. These results are of significant importance for optimizing the synthesis of fluorescent nanoparticles with high photostability and low cost.  相似文献   

10.
Esaka F  Magara M  Suzuki D  Miyamoto Y  Lee CG  Kimura T 《Talanta》2010,83(2):569-573
Information on plutonium isotope ratios in individual particles is of great importance for nuclear safeguards, nuclear forensics and so on. Although secondary ion mass spectrometry (SIMS) is successfully utilized for the analysis of individual uranium particles, the isobaric interference of americium-241 to plutonium-241 makes difficult to obtain accurate isotope ratios in individual plutonium particles. In the present work, an analytical technique by a combination of chemical separation and inductively coupled plasma mass spectrometry (ICP-MS) is developed and applied to isotope ratio analysis of individual sub-micrometer plutonium particles. The ICP-MS results for individual plutonium particles prepared from a standard reference material (NBL SRM-947) indicate that the use of a desolvation system for sample introduction improves the precision of isotope ratios. In addition, the accuracy of the 241Pu/239Pu isotope ratio is much improved, owing to the chemical separation of plutonium and americium. In conclusion, the performance of the proposed ICP-MS technique is sufficient for the analysis of individual plutonium particles.  相似文献   

11.
A method is described for the measurement of 67Zn/6*Zn and 70ZN/68Zn ratios by inductively coupled plasma/mass spectrometry with ultrasonic nebulization. The method provides sufficient accuracy and precision for zinc bioavailability studies that use samples of human feces or blood plasma. Extraction of zinc from ashed samples yields aqueous solutions sufficiently devoid of matrix ions that could affect count rates and isotope ratios. Effects of sodium matrix, zinc concentration, and instrumental parameters on the precision of isotope ratio determinations are documented. Additions of spikes enriched in 67Zn and 70Zn to natural-abundance fecal samples verify that ratios can be determined on solutions 30 μM in zinc (<300 nmol of zinc per sample) with relative accuracies of <1% and relative standard deviations (r.s.d.) of ?1% over the range from natural abundance to 370 atom% excess of 70Zn and to 84 atom% excess of 67Zn.  相似文献   

12.
13.
A low dead volume oxygen scrubbing system was introduced in a commercially available liquid chromatography/isotope ratio mass spectrometry (LC/IRMS) interface to enhance the analytical capability of the system. In the LC/IRMS interface carbon from organic samples is converted into CO(2) inside the mobile phase by wet chemical oxidation using peroxodisulfate (Na(2)S(2)O(8)). After passing the hot reaction zone, surplus oxygen (O(2)) remains dissolved in the liquid phase. Both CO(2) and O(2) diffuse through a transfer membrane into the helium carrier and are transferred to the mass spectrometer. The presence of O(2) in the ion source may have detrimental effects on measurement accuracy and precision as well as on filament lifetime. As a remedy, a new on-line O(2)-removing device has been incorporated into the system.The new O(2) scrubber consists of two parallel hot copper reduction reactors (0.8 mm i.d., active length 120 mm) and a switch-over valve between them. One reactor is regenerated using He/H(2) while the other is actively scavenging O(2) from the gas stream. The capacity of each reduction reactor, expressed as usage time, is between 40 and 50 min. This is sufficient for a single LC run for sugars and organic acids. A further increase of the reduction capacity is accompanied by a peak broadening of about 100%. After switching to a freshly reduced reactor the oxygen background and the delta(13)C values of the reference gas need up to 500 s to stabilize. For repeated injections the delta(13)C values of sucrose remain constant (+/-0.1 per thousand) for about 3000 s. The long-term stability for measurements of sucrose was 0.11 per thousand without the reduction oven and improved slightly to 0.08 per thousand with the reduction oven. The filament lifetime improved by more than 600%, thereby improving the long-term system stability and analytical efficiency. In addition the costs per analysis were reduced considerably.  相似文献   

14.
A method was developed to improve the precision of inductively coupled plasma quadrupole mass spectrometry (ICP-QMS) for the determination of boron isotope ratios (11B/10B) in various environmental materials including seawater. This approach is based on the common analyte internal standardization (CAIS) chemometric algorithm. The sample solution obtained after digestion is spiked with lithium, and both 7Li/6Li and 11B/10B values are measured using long-counting periods (20 min). The CAIS algorithm corrects the measured 11B/10B values for (a) statistical fluctuations resulting from short-term noise; (b) drift in 11B-to-10B ratio as a result of long-term deviation in instrumental parameters likely to occur during long counting times; (c) change in 11B-to-10B ratio caused by variation in matrix elements concentrations; and (d) drift in mass bias correction factor. Comparing boron isotopic ratios in seawater measured by conventional and the new isotope ratio methods validates the procedure. A synthetic isotopic mixture of boron SRM 951 and enriched 10B SRM 952 also was examined. The CAIS method provided a measured boron isotopic ratio precision of 0.05% R.S.D. while eliminating 5.1% matrix concentration error and 0.25% instrumental drift error.  相似文献   

15.
With HOD initially in its vibrational ground state, we present a new detailed interpretation of the OD/OH branching ratio (approximately 3) in the photoinduced process D+OH<--HOD-->H+OD, in the first absorption band. Using semiclassical arguments, we show that the branching ratio has little to do with the initial distribution of configurations, but the initial momentum distribution plays a key role in determination of the branching ratio. The formation of D+OH arises from initial situations where OD is stretching, and it stretches faster than OH, whereas all other motions lead to H+OD. This picture is confirmed by quantum wave-packet calculations.  相似文献   

16.
We demonstrate a high-precision measurement of the isotopomer abundance ratio 14N(15)N(16)O/15N(14)N(16)O/14N(14)N(16)O (approximately 0.37/0.37/100) using three wavelength-modulated 2 microm diode lasers combined with a multipass cell which provides different optical pathlengths of 100 and 1 m to compensate the large abundance difference. A set of absorption lines for which the absorbances have almost the same temperature dependence are selected so that the effect of a change in gas temperature is minimized. The test experiment using pure nearly natural-abundance N(2)O samples showed that the site-selective 15N/14N ratios can be measured relative to a reference material with a precision of +/-3 x 10(-4) (+/-0.3 per thousand) in approximately 2 h.  相似文献   

17.
We report in this paper, the first determination of the isotope ratio (238/235) in an uranium sample by optical emission spectroscopy on a laser-produced plasma at reduced pressure (2.67 Pa). Investigations aimed at developing a new application of laser ablation for analytical isotope control of uranium are presented. Optimized experimental conditions allow one to obtain atomic emission spectra characterized by the narrowest possible line widths of the order of 0.01 nm for the investigated transition UII 424.437 nm. We show the possibility to achieve a relative precision in the range of 5% for an enrichment of 3.5% 235U. The influence of different relevant plasma parameters on the measured line width is discussed.  相似文献   

18.
19.
The highly qualified primary method of species-specific isotope dilution analysis has been employed in this work to evaluate for the first time the levels of butyltin compounds in the estuary of the river Eo (Northwest Spain) where there is, since many years, a high oyster farming activity. A spike solution containing mono-, di- and tributyltin enriched in 119Sn allowed the simultaneous determination of the three compounds in different marine environmental and biological samples collected in this area (seawater samples, sediments and biological tissues of four different marine species). The results obtained in this work showed toxic TBT levels for many marine species in 45% of the seawater samples analyzed whereas significant organotin concentrations were found to be obtained only in one of the sediments analyzed. On the other hand, TBT levels ranging from 20 to almost 200 ng g− 1 (dry weight) were obtained in the different biological tissues analyzed demonstrating the bioaccumulation of organotin compounds in certain marine species.  相似文献   

20.
Gas chromatography/combustion/mass spectrometry (GC-C-MS) and elemental analysis/mass spectrometry (EA-MS) techniques are proposed to estimate delta(13)C and delta(15)N values in heroin, morphine, cocaine and hemp leaves, for the purposes of tracing the geographical origins of seized drugs. The values of isotope ratios for pure drugs and drugs with impurities were compared. It was demonstrated that large samples (up to 3 x 10(-6) g C) were combusted completely, so that the results obtained were valid. The data are considered to be an essential supplement to a wide-scale database designed specifically for the delta(13)C and delta(15)N values of drugs. The potential forensic and academic significance of the results is discussed.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号