共查询到20条相似文献,搜索用时 15 毫秒
1.
Nirogi RV Kandikere VN Shukla M Mudigonda K Maurya S 《Rapid communications in mass spectrometry : RCM》2006,20(15):2286-2292
A simple, sensitive and rapid high-performance liquid chromatography/positive ion electrospray tandem mass spectrometry (MS/MS) method was developed and validated for the assay of tizanidine in human plasma. Following liquid-liquid extraction, the analytes were separated using an isocratic mobile phase on a reversed-phase column and analyzed by MS/MS in the selected reaction monitoring mode. The assay exhibited a linear dynamic range of 50-5000 pg/mL for tizanidine in human plasma. The lower limit of quantification was 50 pg/mL with a relative standard deviation of less than 13%. Acceptable precision and accuracy were obtained for concentrations over the standard curve range. A run time of 2.5 min for each sample made it possible to analyze more than 300 human plasma samples per day. The validated method has been successfully used to analyze human plasma samples for application in pharmacokinetic, bioavailability or bioequivalence studies. 相似文献
2.
Nirogi RV Kandikere VN Shukla M Mudigonda K Maurya S Boosi R 《Biomedical chromatography : BMC》2006,20(9):888-897
A simple, sensitive and rapid high-performance liquid chromatography/electrospray ionization tandem mass spectrometry method was developed and validated for the assay of granisetron in human plasma. Following liquid-liquid extraction, the analytes were separated using an isocratic mobile phase on a reversed-phase C18 column and analyzed by MS in the multiple reaction monitoring mode using the respective [M+H]+ ions, m/z 313/138 for granisetron and m/z 409/228 for the IS. The assay exhibited a linear dynamic range of 0.1-20 ng/mL for granisetron in human plasma. The lower limit of quantification was 100 pg/mL with a relative standard deviation of less than 5%. Acceptable precision and accuracy were obtained for concentrations over the standard curve range. A run time of 2.0 min for each sample made it possible to analyze more than 400 human plasma samples per day. The validated method has been successfully used to analyze human plasma samples for application in pharmacokinetic, bioavailability or bioequivalence studies. 相似文献
3.
4.
5.
A. V. Saprygin V. M. Golik V. A. Kalashnikov O. V. Elistratov M. V. Kazantsev 《Journal of Analytical Chemistry》2010,65(14):1469-1474
A general approach for the determination of the concentration of perfluorocarbons and perfluoropolyether fluids, oils, and
lubricants in Freon-113 (C2F3Cl3) by mass spectrometry was developed. The mode of injection into the ion source, namely, via a gas chromatograph or by means
of direct probe under particular temperature conditions was selected depending on the properties of the compounds to be analyzed.
Chemical ionization in the plasma of isobutene reagent gas was applied. To enhance the sensitivity, selected negative ions
were scanned. The ions were chosen by their maximal intensity and least interference. As an example of using the method, the
results of analysis of Freon solutions with perfluorocarbon lubricant UPI, perfluoropolyether fluids PFPE-180 and PFPE-240,
and also Freon solutions prepared by the extraction of perfluoroorganic species from hydrolyzed uranium hexafluoride solutions
are presented. The linear character of the obtained calibration functions indicated the potency of the quantitative determination
with a detection limit of 0.1 μg/mL. 相似文献
6.
A simple method for the determination of some anthelmintic drugs and phenylbutazone residues in milk and muscle was developed. Following a fast and easy extraction and evaporation procedure, the extract was injected into an ultra performance liquid chromatography system coupled to a single stage Orbitrap detector. The high mass resolution of 50,000 full width at half maximum and corresponding narrow mass windows permitted a very selective and sensitive detection of analytes without requiring fragmentation of the observed [M+H]+ or [M+Na]+ ions. This eliminated some difficulties which have plagued the analysis of compounds belonging to the group of avermectins. The analytical method was validated according to the EU commission decision for Orbitrap based, but also for more traditional tandem mass spectrometry based detection and quantification. Equal repeatability but significantly higher sensitivity for critical compounds (avermectins) was obtained for the Orbitrap based detection. A result of this study was the conclusion that analytes with poor fragmentation properties (e.g. sodium-cationized molecules) can be more easily quantified by single stage high resolution mass spectrometry than by tandem mass spectrometry. 相似文献
7.
《Electrophoresis》2017,38(7):1044-1052
Capillary electrophoresis is an important technique for the characterization of monoclonal antibodies (mAbs), especially in the pharmaceutical context. However, identification is difficult as upscaling and hyphenation of used methods directly to mass spectrometry is often not possible due to separation medium components that are incompatible with MS detection. Here a CE‐MS method for the analysis of mAbs is presented analyzing SDS‐complexed samples. To obtain narrow and intensive peaks of SDS‐treated antibodies, an in‐capillary strategy was developed based on the co‐injection of positively charged surfactants and methanol as organic solvent. For samples containing 0.2% (v/v) of SDS, recovered MS peak intensities up to 97 and 95% were achieved using cetyltrimethylammonium bromide or benzalkonium chloride, respectively. Successful removal of SDS was shown in neutral coated capillaries but also in a capillary with a positively charged coating applying reversed polarity. The usefulness of this in‐capillary strategy was demonstrated also for other proteins and for antibodies dissolved in up to 10% v/v SDS solution, and in other SDS‐containing matrices, including the sieving matrix used in a standard CE‐SDS method and gel‐buffers applied in SDS‐PAGE methods. The developed CE‐MS approaches enable fast and reproducible characterization of SDS‐complexed antibodies. 相似文献
8.
Mendes GD Arruda A Chen LS de Almeida Magalhães JC Alkharfy KM De Nucci G 《Biomedical chromatography : BMC》2012,26(1):129-136
A rapid, sensitive and specific method to quantify cyproheptadine in human plasma using amitriptyline as the internal standard (IS) is described. The analyte and the IS were extracted from plasma by liquid‐liquid extraction using a diethyl‐ether/dichloromethane (70/30; v/v) solvent. After removing and drying the organic phase, the extracts were reconstituted with a fixed volume of acetonitrile/water (50/50 v/v) + 0.1% of acetic acid. The extracts were analyzed by high performance liquid chromatography coupled to electrospray tandem mass spectrometry (LC‐MS/MS). Chromatography was performed isocratically using an Alltech Prevail C18 5 µm analytical column, (150 mm x 4.6 mm I.D.). The method had a chromatographic run time of 4 min and a linear calibration curve ranging from 0.05 to 10 ng/mL (r2 > 0.99). The limit of quantification was 0.05 ng/mL. This HPLC/MS/MS procedure was used to assess the bioequivalence of cyproheptadine in two cyproheptadine + cobamamide (4 mg + 1 mg) tablet formulations (Cobactin® [cyproheptadine + cobamamide] test formulation supplied from Zambon Laboratórios Farmacêuticos Ltda. and Cobavital® from Solvay Farma (standard reference formulation)). A single 4 mg + 1 mg [cyproheptadine + cobamamide] dose of each formulation was administered to healthy volunteers. The study was conducted using an open, randomized, two‐period crossover design with a 1‐week washout interval. Since the 90% CI for Cmax and AUCs ratios were all within the 80‐125% bioequivalence limit proposed by the US Food and Drug Administration, it was concluded that the cyproheptadine test formulation (Cobactin®) is bioequivalent to the Cobavital® formulation for both the rate and the extent of absorption of cyproheptadine. Copyright © 2011 John Wiley & Sons, Ltd. 相似文献
9.
On‐line coupling of LC and ICP‐MS has been used for fractionation and detection of species of Cu, Fe, I, Se and Zn in human serum. It has been shown that anion exchange chromatography provided better separation capability (both intra‐ and inter‐element) than size‐exclusion chromatography. The mobile phases for ion exchange chromatography consisted of Tris–HNO3 buffer and ammonium salt (nitrate, acetate or formate). Formate was found to be the best mobile phase counter ion, enabling good chromatographic separation, and is acceptable for mass spectrometry too. The quantitative evaluation of element concentrations adhering to individual fractions was performed by the peak area normalization method. The repeatability of results ranged from 3 to 15% (depending on the element concentration level) and represented the main part of the result uncertainty. The accuracy of Cu and Zn fraction determinations was confirmed by comparison with the isotope dilution technique. Copyright © 2006 John Wiley & Sons, Ltd. 相似文献
10.
Nirogi RV Kandikere VN Shukla M Mudigonda K Maurya S Komarneni P 《Biomedical chromatography : BMC》2007,21(2):209-216
A rapid high-performance liquid chromatography/positive ion electrospray tandem mass spectrometry method was developed and validated for the quantification of fexofenadine in human plasma using mosapride as internal standard. Following solid-phase extraction, the analytes were separated using an isocratic mobile phase on a reverse-phase column and analyzed by MS/MS in the multiple reaction monitoring mode using the respective [M+H]+ ions, m/z 502/466 for fexofenadine and m/z 422/198 for the IS. The method exhibited a linear dynamic range of 1-500 ng/mL for fexofenadine in human plasma. The lower limit of quantification was 1 ng/mL with a relative standard deviation of less than 5% for fexofenadine. Acceptable precision and accuracy were obtained for concentrations over the standard curve range. The total chromatographic run time of 2 min for each sample made it possible to analyze more than 400 human plasma samples per day. The validated method has been successfully used to analyze human plasma samples for application in pharmacokinetic, bioavailability or bioequivalence studies. 相似文献
11.
Jaisson S Gorisse L Pietrement C Gillery P 《Analytical and bioanalytical chemistry》2012,402(4):1635-1641
Homocitrulline (HCit), an amino acid formed by the carbamylation of ε-amino groups of lysine residues, is considered a promising
biomarker for monitoring diseases such as chronic renal failure and atherosclerosis. This paper describes a tandem mass spectrometric
method for total, protein-bound and free HCit measurement in plasma samples. HCit was separated from other plasma components
by hydrophilic interaction liquid chromatography. Detection was achieved by monitoring transitions of 190.1 > 127.1 and 190.1 > 173.1
for HCit, and 183.1 > 120.2 for d7-citrulline used as internal standard. This method allowed HCit quantification within 5.2 min and was precise (inter-assay
CV < 5.85%), accurate (mean recoveries ranging from 97% to 106%), and exhibited a good linearity from 10 nmol/L to 1.6 μmol/L.
Plasma samples from control and uremic mice (n = 10) were analyzed. In control mice, mean total plasma HCit concentration was 0.78 ± 0.12 μmol/mol amino acids, whereas
it was increased 2.7-fold in uremic mice plasma, reaching 2.10 ± 0.50 μmol/mol amino acids (p < 0.001). In conclusion, this method exhibits good analytical performances and meets the criteria of sensitivity suitable
for HCit concentration assessment in plasma samples. 相似文献
12.
单分散磁性亚微米粒子固相萃取-液相色谱-串联质谱法测定牛奶中的双酚A 总被引:2,自引:0,他引:2
采用溶剂热还原法制备的单分散性Fe3O4磁性亚微米粒子(Fe3O4-magnetic submicron particles)进行固相萃取(SPE),结合高效液相色谱-串联质谱(HPLC-MS/MS)测定了牛奶中的双酚A(BPA)。对溶液的pH、磁性粒子用量、洗脱溶剂和体积等影响因素进行了优化,得到的最优萃取条件为: 溶液的pH 6,磁性粒子用量3.5 mg,用0.4 mL甲醇洗脱。以Agilent XDB C18柱为分析柱,流动相为乙腈-0.25 mmol/L氨水(80:20, v/v)溶液,在负离子模式下进行MS/MS测定。双酚A在1~100 μg/L范围内线性关系良好(r=0.9993);在3个添加水平下,回收率为85.3%~96.1%,相对标准偏差小于10%;通过不断稀释加标浓度确定方法的检出限(信噪比为3)为1.0 μg/L。该方法简单、准确,能用于牛奶中双酚A的快速测定。 相似文献
13.
Hua Zhang Haiyan Lu Haichun Huang Jianchuan Liu Xiaowei Fang Bi-Feng Yuan Yu-Qi Feng Huanwen Chen 《Analytica chimica acta》2016
Polycyclic aromatic hydrocarbons (PAHs) are a group of ubiquitous environmental contaminants raising worldwide concerns due to their carcinogenic effects. In this study, 1-hydroxypyrene (1-OHP, the most widely used biomarker of internal dose of PAHs exposure) in undiluted human urine samples (10 mL) was selectively enriched by polypyrrole-coated Fe3O4 magnetite nanocomposites (termed as Fe3O4@Ppy, 1 mg) and then directly eluted by the electrospraying solvent (acetone/benzene/acetic acid (v/v/v, 90/10/1); 100 uL) biased with −3.5 kV to produce the deprotonated 1-OHP anions for mass spectrometric analysis. The method established here significantly improved the current performance for detection of urinary 1-OHP, providing the speed for a single sample analysis within 4 min, the limits of detection (LOD) of 0.0001 μg L−1, the linear response range of 0.001–5.000 μg L−1 (R2 = 0.9994), recovery rates of 90.6–96.1%, and relative standard deviation (RSD, n = 6) values between 2.9% and 8.0%. Human samples including raw human urine collected from 10 healthy volunteers (5 smokers and 5 nonsmokers) and 7 lung cancer patients have been successfully analyzed, showing that magnetic solid-phase extraction (MSPE) coupled with internal extractive electrospray ionization mass spectrometry (iEESI-MS) is an alternative strategy for high throughput quantitative detection of urinary 1-OHP for health risk assessment of PAHs exposure. 相似文献
14.
Chainet F Courtiade M Lienemann CP Ponthus J Donard OF 《Journal of chromatography. A》2011,1218(51):9269-9278
A method for the speciation of silicon compounds in petroleum products was developed using gas chromatography coupled to mass spectrometry (GC-MS). Prior to analysis, several precautions about storage and conservation were applied for all samples. In spiked gasoline samples, limits of detection between 24 and 69 μg kg(-1) for cyclic siloxanes (D(4)-D(6)) and between 1 and 7 μg kg(-1) for other species were obtained. In this study, cyclic siloxanes (D(n)) and one ethoxysilane were quantified for the first time in petroleum products by a specific method based on response factor calculation to an internal standard. This method was applied to four samples of naphthas and gasolines obtained from a steam cracking process. Cyclic siloxanes were predominant in four investigated samples with concentrations ranging between 101 and 2204 μg kg(-1). Cyclic siloxane content decreased with an increase in their degree of polymerization. During a steam cracking process, silicon concentrations determined by GC-MS SIM (single ion monitoring) significantly increase. This trend was confirmed by ICP-OES (inductively coupled plasma optical emission spectroscopy) measurements but a difference on the total silicon content was observed, certainly highlighting the presence of unknown silicon species. GC-MS SIM method gives access to the chemical nature of the silicon species, which is crucial for the understanding of hydrotreatment catalyst poisoning in the oil and gas industry. 相似文献
15.
Becker JS Becker JS Zoriy MV Dobrowolska J Matucsh A 《European journal of mass spectrometry (Chichester, England)》2007,13(1):1-6
Of all the inorganic mass spectrometric techniques, laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) plays a key role as a powerful and sensitive microanalytical technique enabling multi- element trace analysis and isotope ratio measurements at trace and ultratrace level. LA-ICP-MS was used to produce images of detailed regionally-specific element distribution in 20 microm thin sections of different parts of the human brain. The quantitative determination of copper, zinc, lead and uranium distribution in thin slices of human brain samples was performed using matrix-matched laboratory standards via external calibration procedures. Imaging mass spectrometry provides new information on the spatially inhomogeneous element distribution in thin sections of human tissues, for example, of different brain regions (the insular region) or brain tumor tissues. The detection limits obtained for Cu, Zn, Pb and U were in the ng g(-1) range. Possible strategies of LA-ICP-MS in brain research and life sciences include the elemental imaging of thin slices of brain tissue or applications in proteome analysis by combination with matrix-assisted laser desorption/ionization MS to study phospho- and metal- containing proteins will be discussed. 相似文献
16.
17.
《Spectrochimica Acta Part B: Atomic Spectroscopy》2006,61(7):841-849
The particle size distribution in laser ablation inductively coupled plasma mass spectrometry is known to be a critical parameter for complete vaporization of particles. Any strategy to reduce the particle size distribution of laser generated aerosols has the potential to increase the ion signal intensity and to reduce fractionation effects. Due to the fact that vapor generation, nucleation, condensation, and agglomeration take place within an extremely short period of time, ablation under atmospheric pressure might not allow influencing these processes while under reduced pressure condition the cooling of the aerosol and therefore the condensation is expected to be slower. In this study, a low pressure laser ablation cell for the generation of laser aerosols was coupled to an ICP-MS. In contrast to the previously developed trapped ablation mode, the newly designed cell allows the adjustment of the pressure in the ablation cell between 20 and 1400 mbar prior to the ablation.Ablation experiments carried out using this configuration showed a dependence of the aerosol properties (size distribution and particle structure) on the ablation cell pressure. The intensity ratio U/Th measured as a figure of merit for complete vaporization within the ICP indicated a change in the aerosol structure at approximately 500 mbar toward smaller particle size. A significant difference between low pressure and at ambient pressure ablated aerosol was observed. The intensity ratios (U/Th) of the ablated sample moves closer to the bulk composition at lower pressures at the expense of sensitivity. Therefore the decrease in the ICP-MS signal intensity in the low pressure cell can be attributed to vapor deposition within the ablation cell walls.Moreover, scanning electron microscope images of aerosols collected on filters after the low pressure ablation cell suggest the possibility of a slower cooling velocity of the aerosol, which was observed in the condensed material on the surface of ejected spherical particles. The expansion of the laser aerosol was also investigated using polished brass substrates in the expansion path-way for particle collection. 相似文献
18.
The combination of supramolecular chemistry and MS has not only been fruitful in the field of gas-phase fundamental studies of host-guest complexes and supramolecular assemblies. Mass spectrometric analysis has also benefited from the ability of supramolecular systems to behave as pseudophases in which solutes partition from the bulk solvent phase. Supramolecular systems-based extraction and concentration schemes and separation techniques have been widely used in different fields of analytical chemistry and are ideally suited for coupling with MS. This review describes the present status of the application of supramolecular chemistry in mass spectrometric analysis and includes topics such as the use of coacervative liquid-liquid extraction and hemimicelle/admicelle-based SPE of organic compounds prior to chromatography and electrophoresis. It also discusses the recent advances in enantioselective analysis using CD in electrophoresis- and chromatography-MS. The potential and analytical challenges of these approaches in environmental and bioanalytical chemistry, where one can expect significant developments in the future, are outlined. 相似文献
19.
We have analyzed phosphorus in an enzymatically digested DNA molecule using capillary electrophoresis (CE) hyphenated with inductively coupled plasma mass spectrometry (ICP-MS). The DNA concentration was quantified by the phosphorus value obtained in the CE-ICP-MS analysis. The CE-ICP-MS measurement, for which the interface device AIF-01 equipped three layered nebulizer was adopted, was achieved with limited μL/min nebulizing without loss of sample in the vaporizing chamber. The samples of nucleotides and free phosphate were separated well in the CE-ICP-MS measurement, and the calibration curve (0.1-10μg/mL) of the phosphorus showed a linear (R(2)=0.999) increase in intensity. After digestion of the 100-bp double-strand DNA sample to deoxyribonucleotide-5'-monophosphates (dNMPs) by phosphodiesterase-I, phosphorus was detected by CE-ICP-MS without further purification steps. In this study, we applied two calculation schemes of DNA analysis using a dNMP concentration obtained from CE-ICP-MS. Comparative CE-ICP-MS analysis with DNA digested to dNMPs showed that the assay gave an equal value obtained from the total DNA quantification using fluorescence detection. The detection limits of the DNA sample obtained from these species and phosphorus in nucleotides using CE-ICP-MS were 3.1-26ng/mL. These LOD values were equal to the conventional fluorescence determination of DNA. 相似文献
20.
Capillary electrophoresis coupled to mass spectrometry (CE-MS) is reported for the first time as an alternative and powerful analytical method for the characterization and monitoring of N-substituted 1-amino-1-deoxyketoses (Amadori compounds). It allows rapid separation and identification of Amadori compounds, while benefiting from the well-known advantages of MS, such as specificity and sensitivity. Amadori compounds of several amino acids, such as glycine, valine, isoleucine, methionine, proline, and phenylalanine, as well as a cysteine-derived compound, were separated and/or discriminated using CE-MS/MS under standard conditions. The technique may also be useful to study the stability and degradation kinetics of other labile charged Maillard intermediates that play an important role in food and medical science. 相似文献