首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
The potential for using testosterone and nandrolone esters in racehorses to boost the biological concentrations of these steroids and enhance athletic performance is very compelling and should be seriously considered in formulating regulatory policies for doping control. In order to regulate the use of these esters in racehorses, a sensitive and validated method is needed. In this paper, we report such a method for simultaneous separation, screening, quantification and confirmation of 16 testosterone and nandrolone esters in equine plasma by ultra high performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS). Analytes were extracted from equine plasma by liquid-liquid extraction using a mixture of methyl tert-butyl ether and ethyl acetate (50:50, v/v) and separated on a sub-2 micron C(18) column. Detection of analytes was achieved on a triple-quadrupole mass spectrometer by positive electrospray ionization mode with selected reaction monitoring (SRM). Mobile phase comprised 2 mM ammonium formate and methanol. Deuterium-labeled testosterone enanthate and testosterone undecanoate were used as dual-internal standards for quantification. Limits of detection (LOD) and quantification (LOQ) were 25-100 pg/mL and 100-200 pg/mL, respectively. The linear dynamic range of quantification was 100-10,000 pg/mL. For confirmation of the presence of these analytes in equine plasma, matching of the retention time with mass spectrometric ion ratios from MS/MS product ions was used. The limit of confirmation (LOC) was 100-500 pg/mL. The method is sensitive, robust, selective and reliably reproducible.  相似文献   

2.
In this work, the suitability of the microporous membrane liquid–liquid extraction (MMLLE) technique for the concentration of several organophosphate esters (OPs) in water samples is assessed. Analytes were first extracted into a few microlitres of an organic solvent, immobilized in the pores of a hollow polypropylene membrane, and then determined by gas chromatography with nitrogen–phosphorus detection (GC–NPD). Main parameters controlling the efficiency of the extraction step were identified and their effects on the performance of the technique discussed. Under final working conditions, 2 cm long polypropylene membranes, containing about 7 μL of octanol in the pores, were dipped in a glass vial filled with 115 mL of water with a 30% of sodium chloride. Extractions were carried out for 12 h, at room temperature, under magnetic stirring. After that, analytes were recovered from the membrane with 0.2 mL of ethyl acetate. This extract was mixed with the internal standard (50 μL of a tripentyl phosphate solution in the same solvent) and finally reduced to ca. 50 μL. Overall enrichment factors for the optimized method ranged from 35 to 1400 times, and the achieved limits of quantification from 0.008 to 0.12 ng mL−1, depending on the considered compound. Globally, the method showed an acceptable linearity and precision for all species, except for tris(2-ethylhexyl) phosphate (TEHP). Performance of the MMLLE approach is compared with that reported for other solid- and liquid-phase microextraction techniques and its suitability for the analysis of real water samples discussed.  相似文献   

3.
A multiresidue analytical method for the determination of emerging pollutants belonging to personal care products (PCPs) (antimicrobials, preservatives), benzotriazole UV stabilizers (BUVSs) and organophosphorus compounds (OPCs) in fish has been developed using high speed solvent extraction (HSSE) followed by silica gel clean up and ultra fast liquid chromatography coupled with tandem mass spectrometry (UFLC–MS/MS) analysis. Developed extraction and clean up method yielded good recovery (>70%) for all the four groups of emerging pollutants, i.e. antimicrobials (78.5–85.6%), preservatives (85.0–89.4%), BUVSs (70.9–112%) and OPCs (81.6–114%; except for TEP – 68.9% and TPeP – 58.1%) with RSDs ranging from 0.7 to 15.4%. Intra- and inter-day repeatabilities were less than 19.8% and 19.0%, respectively at three spiked levels. The concentrations were given in lipid weight (lw) basis, and the method detection limits were achieved in the lowest range of 0.001–0.006 ng g−1 for two antimicrobials, 0.001–0.015 ng g−1 for four preservatives, 0.0002–0.009 ng g−1 for eight BUVSs and 0.001–0.014 ng g−1 for nine OPCs. Finally, the method was successfully validated as a simple and fast extraction method for the determination of 23 compounds belonging to PCPs, BUVSs and OPCs and applied to the analysis of three species of fish from Manila Bay, the Philippines. Concentrations ranged from 27 to 278 ng g−1 for antimicrobials, 6.61 to 1580 ng g−1 for paraben preservatives, −1 for BUVSs and ND (not detected) to 266 ng g−1 for OPCs suggesting the ubiquitous contamination by these emerging pollutants in Manila Bay. This is the first method developed for the determination of triclocarban, four paraben preservatives and four BUVSs, in fish.  相似文献   

4.
Wang C  Li L  Xie T  Zhang W  Liu C  Zhu N 《色谱》2011,29(8):731-736
以丙酮为萃取溶剂,采用微波辅助萃取技术对纺织品中禁用有机磷阻燃剂进行萃取,萃取液进行气相色谱/串联质谱测定,从而建立了一种微波萃取-气相色谱/串联质谱分析方法,对纺织品中禁用有机磷阻燃剂进行了测定。6种禁用有机磷阻燃剂三-(1-氮杂环丙烯基)氧化膦(TEPA)、三-(2-氯乙基)磷酸酯(TCEP)、三-(2,3-二氯丙基)磷酸酯(TDCP)、二-(2,3-二溴丙基)磷酸酯(DDBPP)、三-(邻甲苯基)磷酸酯(TOCP)和三-(2,3-二溴丙基)磷酸酯(TRIS)的线性范围分别为9.17~366.80、0.95~75.98、1.04~83.20、41.60~832.00、3.80~75.90、40.48~809.60 ?g/L,在S/N=10的条件下,检出限分别为3.0、0.2、0.3、25.0、2.5、29.0 ?g/kg。方法精密度为3.80~8.79 %,回收率为82.62~96.88 %。气相色谱/串联质谱母离子和子离子一一对应的多反应监测模式有效地去除了基体杂质干扰和假阳性现象。该方法简便快速、灵敏度高,定性准确,可完全满足纺织品中禁用有机磷阻燃剂的检测要求。  相似文献   

5.
A rapid and reliable LC-MS/MS method for the simultaneous confirmation of twelve non steroidal anti-inflammatory drugs (NSAIDs) in bovine milk was developed and fully validated in accordance with the European Commission Decision 2002/657/EC. The validation scheme was built in accordance with the MRLs or target analytical levels (EU-CRL recommended concentrations and detection capabilities) of the analytes, except for diclofenac for which the lower level of validation achieved was 0.5 μg kg(-1) whereas its MRL is 0.1 μg kg(-1). The NSAIDs investigated were as follows: phenylbutazone (PBZ), oxyphenylbutazone (OPB), naproxen (NP), mefenamic acid (MF), vedaprofen (VDP), flunixin (FLU), 5-hydroxyflunixin (FLU-OH), tolfenamic acid (TLF), meloxicam (MLX), diclofenac (DC), carprofen (CPF) and ketoprofen (KTP). Several extraction procedures had been investigated during the development phase. Finally, the best results were obtained with a procedure using only methanol as the extraction solvent, with an evaporation step included and no further purification. Chromatographic separation was achieved on a C18 analytical column and the run was split in 2 segments. Matrix effects were also investigated. Data acquisition implemented for the confirmatory purpose was performed by monitoring 2 MRM transitions per analyte under the negative electrospray mode. Mean relative recoveries ranged from 94.7% to 110.0%, with their coefficients of variation lying between 2.9% and 14.7%. Analytical limits expressed in terms of decision limits (CCα) were evaluated between 0.69 μg kg(-1) (FLU) and 27.54 μg kg(-1) (VDP) for non-MRL compounds, and at 0.10 (DC), 15.37 (MLX), 45.08 (FLU-OH), and 62.96 μg kg(-1) (TLF) for MRL compounds. The validation results proved that the method is suitable for the screening and confirmatory steps as implemented for the French monitoring plan for NSAID residue control in bovine milk.  相似文献   

6.
Xu Y  Shou LF  Wu YL 《Journal of chromatography. A》2011,1218(38):6663-6666
This paper presents a rapid analytical method for the simultaneous determination of flonicamid and its metabolites N-(4-trifluoromethylnicotinoyl) glycine (TFNG), 4-trifluoromethylnicotinic acid (TFNA), and 4-trifluoromethylnicotinamide (TFNA-AM) in vegetables using QuEChERS by liquid chromatography-tandem mass spectrometry (LC-MS/MS). Samples were extracted with acetonitrile. The extract was purified through QuEChERS method with primary secondary amine (PSA) and graphite carbon black (GCB). Then the extract was diluted with 0.1% formic acid in water, and analyzed by LC-MS/MS on a Waters Acquity BEH C18 column with methanol/0.1% formic acid in water as mobile phase with gradient elution. The linearity of the analytical response across the studied range of concentrations (0.20-500 μg/L) was excellent, obtaining correlation coefficients higher than 0.998. No significant matrix effects were observed. Recovery studies were carried out on spiked spinach and cucumber blank samples, at four concentration levels (0.01, 0.05, 0.50 and 2.0 mg/kg) performing six replicates at each level. Mean recoveries of 81.3-94.8% with CVs of 2.4-7.0% were obtained. The method demonstrated to be suitable for the simultaneous determination of flonicamid and its metabolites in vegetables.  相似文献   

7.
This paper describes the development and validation of a method for the simultaneous determination of 53 multi-class emerging organic pollutants in water samples using solid-phase extraction (SPE) followed by liquid chromatography-tandem mass spectrometry (LC-MS/MS), using electrospray ionisation (ESI) in both positive and negative modes. Target compounds include acidic herbicides, UV filters, insect repellents, organophosphorous flame retardants, a bactericide, pharmaceuticals and metabolites. A single SPE consisting on the loading of 200-500 mL of sample adjusted to pH 7 on Oasis HLB 200mg cartridges and elution with methanol, permitted obtaining good recoveries: higher than 60% for tap, surface and wastewater in most cases. The 7 isotopically labelled internal standards effectively compensated losses during sample preparation and matrix effects at LC-MS/MS determination. The precision of the method, calculated as relative standard deviation (RSD) was below 15% for all compounds and all tested matrices. Detection limits (LODs) based on the confirmation, less intense, MRM (multiple reaction monitoring) transition and considering blanks varied between 0.3 and 30 ngL(-1). Finally, the developed method was applied to the determination of target analytes in various samples, including tap, surface and waste water. Among the tested emerging pollutants, 31 were found in wastewater in concentrations reaching up to 10 microgL(-1) in the case of ibuprofen. Also, 13 species were detected in tap water with concentrations up to 0.13 microgL(-1) for tri(chloropropyl) phosphate (TCPP).  相似文献   

8.
A fast, robust and highly sensitive analysis method for determination of trace levels of organophosphate ester (OPE) flame retardants and plasticizers in lipid-rich samples was presently developed, and based on ultra-high performance liquid chromatography-tandem mass spectrometry coupled to a positive atmospheric pressure chemical ionization source (UHPLC-MS/MS-APCI(+)). The target OPEs in the sample were extracted from the biota samples, such as egg and liver, by ultrasonic extraction, and cleaned up further by dispersive solid phase extraction (d-ESP). As a result, background contamination was largely reduced. Different dispersive ESP sorbents were tested and primary secondary amine (PSA) bonded silica sorbents showed the best recoveries for these target OPEs. The recoveries obtained were in the range 54–113% (RSD 17%), with method limits of quantification (MLOQs) ranging between 0.06 and 0.29 ng/g in egg, and 0.05 and 0.50 ng/g w.w. in liver sample. The matrix effects (MEs) associated with using APCI(+) and ESI(+) sources were investigated. APCI(+) showed much less ion suppression than ESI(+) for the determination of these OPEs. For egg and liver samples, the APCI(+) ME values ranged from 40% to 94%, while ESI(+) ME values ranged from 0% to 36%. Although APCI(+) was used for the determination of OPEs, the ionization mechanism might mainly be a thermospray ionization process. This UHPLC-MS/MS-APCI(+) method showed good response linearity for calibration (R2 > 0.99). The proposed method was applied to real environmental bird egg and fish samples, where several OPE were quantifiable and different OPE patterns was observed between samples.  相似文献   

9.
A method is described for the identification and the quantitative determination of the triphenylmethane dyes, malachite green (MG), crystal violet (CV), brilliant green (BG) and leuco malachite green (LMG) and leuco crystal violet (LCV). The analytes were isolated from the matrix by liquid-liquid extraction with acetonitrile. Determination was performed using LC-MS/MS with positive electrospray ionisation. 4 different deuterated internal standards were introduced to improve the quantitative performance of the method. The method has been validated in line with the EU criteria of Commission Decision 2002/657/EC in accordance with the minimum required performance limit (MRPL) set at 2 μgkg(-1) for the sum of MG and LMG. For all the monitored compounds, accuracy, intra-day and inter-day precision were determined at each level of fortification (0.5, 0.75, 1.0 and 2.0 μgkg(-1)). Decision limits CCα and detection capabilities CCβ were calculated according to the standard ISO 11843-2. A study on the applicability of the method was conducted on various aquacultured species with the aim to assess the matrix effects. The presence of residues of leuco brilliant green in fish has also been confirmed from experimental study performed on trout treated with brilliant green, using LTQ-Orbitrap mass spectrometer.  相似文献   

10.
A procedure for the determination of 10 organophosphates, used as flame retardants and plasticizers, in sediment samples is presented. Microwave-assisted extraction (MAE) and gas chromatography with inductively coupled plasma mass spectrometry (GC-ICP-MS) were used for sample preparation and analytes determination, respectively. Influence of different variables on the performance of extraction and determination processes is thoroughly discussed. Temperature, type and amount of organic solvent showed a major effect on the yield of MAE. Regarding GC-ICP-MS detection, the combination of pulsed splitless injection with low radio frequency (rf) power, hard extraction conditions (referred to lens voltage) and addition of nitrogen (0.03 L min−1) to the argon plasma provided the best sensitivity. Under final working conditions, recoveries between 78% and 105%, for samples spiked at different concentration levels, and limits of quantification from 2 to 4 ng g−1 were achieved. Analysis of unspiked sediments confirmed the excellent selectivity of the proposed method for real-life polluted sample analysis.  相似文献   

11.
何静  叶曦雯  汤志旭  牛增元  罗忻  邹立 《色谱》2020,38(6):679-686
建立了悬浮固化-分散液液微萃取结合液相色谱-串联质谱测定纺织废水中5种痕量磷系阻燃剂的方法。通过对萃取过程中萃取剂、分散剂的种类与体积、盐浓度、溶液pH值等对萃取效率的影响因素优化,确立了最佳萃取条件。采用了密度小于水的十一烷醇(400μL)为萃取剂,甲醇(300μL)为分散剂,控制溶液pH值在6~9之间,NaCl添加量为2 g,萃取时间为涡旋2 min。在优化的萃取条件下,该方法在2~100μg/L均有良好的线性关系,相关系数大于0.995,除二(2,3-二溴丙基)磷酸酯(BIS)的检出限为5μg/L外,三(2-氯乙基)磷酸酯(TCEP)、三(1,3-二氯-异丙基)磷酸酯(TDCP)、三(1-氮丙啶基)氧化膦(TEPA)和三(2,3-二溴丙基)磷酸酯(TRIS)的检出限均为2μg/L。后整理、染色和印花等实际废水样品加标试验表明,方法的平均回收率为71.6%~114.5%, RSD为2.7%~11.2%(n=6)。对11个样品进行检测,其中3个废水样品检出TCEP与TDCP化合物,含量为2.6~3.4μg/L。本方法简单,快速,灵敏度好且环保绿色,能够对纺织废水中的5种痕量磷系阻燃剂...  相似文献   

12.
Streamlined quantitative metabolomics in central metabolism of bacteria would be greatly facilitated by a high-efficiency liquid chromatography (LC) method in conjunction with accurate quantitation. To achieve this goal, a methodology for LC-tandem quadrupole mass spectrometry (LC-MS/MS) involving a pentafluorophenylpropyl (PFPP) column and culture-derived global (13)C-labeled internal standards (I.Ss.) has been developed and compared to hydrophilic interaction liquid chromatography (HILIC)-MS/MS and published combined two-dimensional gas chromatography and LC methods. All 50 tested metabolite standards from 5 classes (amino acids, carboxylic acids, nucleotides, acyl-CoAs and sugar phosphates) displayed good chromatographic separation and sensitivity on the PFPP column. In addition, many important critical pairs such as isomers/isobars (e.g. isoleucine/leucine, methylsuccinic acid/ethylmalonic acid and malonyl-CoA/3-hydroxybutyryl-CoA) and metabolites of similar structure (e.g. malate/fumarate) were resolved better on the PFPP than on the HILIC column. Compared to only one (13)C-labeled I.S., the addition of global (13)C-labeled I.Ss. improved quantitative linearity and accuracy. PFPP-MS/MS with global (13)C-labeled I.Ss. allowed the absolute quantitation of 42 metabolite pool sizes in Methylobacterium extorquens AM1. A comparison of metabolite level changes published previously for ethylamine (C2) versus succinate (C4) cultures of M. extorquens AM1 indicated a good consistency with the data obtained by PFPP-MS/MS, suggesting this single approach has the capability of providing comprehensive metabolite profiling similar to the combination of methods. The more accurate quantification obtained by this method forms a fundamental basis for flux measurements and can be used for metabolism modeling in bacteria in future studies.  相似文献   

13.
An ultra performance liquid chromatography–tandem mass spectrometry (UPLC‐MS/MS) method has been developed for the determination of nifedipine in human plasma using nifedipine‐d6 as the internal standard (IS). The plasma samples were prepared by solid‐phase extraction on Phenomenex Strata‐X cartridges employing 200 μL human plasma. Chromatography was carried out on Waters Acquity UPLC BEH C18 (50 × 2.1 mm, 1.7 µm particle size) analytical column under isocratic conditions using a mobile phase consisting of 4.0 mm ammonium acetate‐acetonitrile (15:85, v/v). The precursor → product ion transitions for nifedipine (m/z 347.2 → 315.2) and IS (m/z 353.1 → 318.1) were monitored on a triple quadrupole mass spectrometer, operating in the multiple reaction monitoring and positive‐ion mode. The method was validated over a wide dynamic concentration range of 0.050–150 ng/mL. Matrix effect was assessed by post‐column analyte infusion and the mean extraction recovery was 95.6% across four quality control levels. The method is rugged and rapid with a total run time of 1.2 min and was applied to a bioequivalence study of 20 mg nifedipine tablet formulation in 30 healthy Indian subjects under fasting condition. Assay reproducibility was confirmed by reanalysis of 116 incurred samples. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

14.
罗碧容  钱蜀  谢振伟  姚欢  熊杰  赵红 《色谱》2015,33(7):740-745
以地表水环境质量标准严格控制的特定项目为依据,建立了直接进样-高效液相色谱-串联质谱同时测定水中13种化学性质差异较大的有机污染物的分析方法,这13种有机污染物为乐果、敌敌畏、敌百虫、对硫磷、甲基对硫磷、马拉硫磷、内吸磷、丙烯酰胺、苯胺、联苯胺、甲萘威、微囊藻毒素-LR、阿特拉津。水样经0.22 μm尼龙66滤膜过滤后,采用Kromasil 100-5 C18柱(150 mm×2.1 mm, 5 μm)分离,以甲醇-0.01%甲酸水溶液为流动相进行梯度洗脱,流速0.5 mL/min,柱温40 ℃,电喷雾正离子模式(ESI+)电离,多反应监测模式(MRM)进行检测,外标法定量。13种化合物的浓度与其峰面积在一定浓度范围内均呈现良好的线性关系(r≥0.9995),方法检出限为0.02~0.1 μg/L。测定低、中、高浓度的加标样品,13种化合物的相对标准偏差为0.5%~5.0%(n=6),实际样品加标平均回收率为81.2%~112%。此方法灵敏度高、干扰小、分析速度快,可适用于地表水、地下水中这13种有机污染物的同时分析。  相似文献   

15.
A liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the determination of ziprasidone (ZIP) in human plasma was developed. ZIP and N-methyl ziprasidone as internal standard (IS) were extracted from alkalinized plasma using tert- butyl methyl ether. Separation was performed isocratically on a C8 column with 90% acetonitrile containing 2 mmol/L ammonium acetate as a mobile phase with a total run time of 2.5 min. MS/MS transitions of m/z 413 --> 194 and m/z 427 --> 177 of the analyte and internal standard were used for quantification. Confirmatory ions of m/z 413 --> 177 and m/z 427 --> 180 were collected as well. The calibration curve based on peak-area ratio was linear up to at least 200 ng/mL with a detection limit of 0.1 ng/mL. The method showed satisfactory reproducibility with a coefficient of variation of less than 5%. The method was successfully applied to the analysis of ZIP in spiked human plasma.  相似文献   

16.
We developed a simple and rapid method for the simultaneous determination of phosphorus-containing amino acid herbicides (glyphosate, glufosinate, bialaphos) and their major metabolites, aminomethylphosphonic acid (AMPA) and 3-methylphosphinicopropionic acid (MPPA), in human serum. Serum samples were filtrated through an ultrafiltration membrane to remove proteins. The filtrate was then washed with chloroform, and injected into a liquid chromatography-tandem mass spectrometry (LC-MS/MS) system. Chromatographic separation was achieved on a hydrophilic interaction chromatography (HILIC) column. Determination of the target herbicides and metabolites was successfully carried out without derivatization or solid phase extraction (SPE) cartridge clean-up. The recoveries of these compounds, added to human serum at 0.2μg/mL, ranged from 94% to 108%, and the relative standard deviations (RSDs) were within 5.9%. The limits of detection (LODs) were 0.01μg/mL for MPPA, 0.02μg/mL for AMPA, 0.03μg/mL for both glyphosate and glufosinate, and 0.07μg/mL for bialaphos, respectively.  相似文献   

17.
Li Y  Dong F  Liu X  Xu J  Li J  Kong Z  Chen X  Song W  Wang Y  Zheng Y 《Journal of chromatography. A》2011,1218(38):6667-6674
A novel and sensitive method was developed for the simultaneous determination of fenbuconazole and its main metabolites enantioselectively using chiral liquid chromatography coupled with tandem mass spectrometry. The separation and determination were performed using reversed-phase chromatography on a cellulose chiral stationary phase, a Chiralcel OD-RH (150 mm×4.6 mm) column, under isocratic conditions at 0.5 mL/min flow rate. The effects of three cellulose-based columns and three amylose-based columns on the separation were also investigated. The elution orders of the eluting enantiomers were identified by an optical rotation detector. The QuEChERS (acronym for Quick, Easy, Cheap, Effective, Rugged and Safe) method and solid-phase extraction (SPE) were used for the extraction and clean-up of the soil and water samples, respectively. Parameters including the matrix effect, linearity, precision, accuracy and stability were evaluated. Under optimal conditions, the mean recoveries for all enantiomers from the soil samples were 82.5-104.1% with 2.7-9.5% intra-day relative standard deviations (RSD) and 5.7-11.2% inter-day RSD at 5, 25 and 50 μg/kg levels; the mean enantiomer recoveries from the water samples were 81.8-104.6% with 2.6-11.4% intra-day RSD and 5.3-10.4% inter-day RSD at 0.25, 0.5 and 2.5 μg/L levels. Coefficients of determination R2≥0.9991 were achieved for each enantiomer in the soil and water matrix calibration curves within the range of 1.0-125 μg/L. The limits of detection (LOD) for all enantiomers in the soil and water were less than 0.8 μg/kg, whereas the limit of quantification (LOQ) did not exceed 2.5 μg/kg. The results of the method validation confirm that this proposed method is convenient and reliable for the enantioselective determination of the enantiomers of fenbuconazole and its main metabolites in soil and water.  相似文献   

18.
建立了分析测定水环境中十氯酮的液相色谱-串联质谱法。水样经液液萃取、净化后,采用Eclipse plus C18柱(100 mm×2.1 mm,3.5 μm)分离,乙腈和水为流动相进行梯度洗脱,在电喷雾负离子多反应监测模式下进行检测,同位素内标法定量。结果表明:采用液相色谱-质谱联用技术,证实了十氯酮在甲醇中以半缩醛的形式存在,而在丙酮/乙腈中以偕二醇的形式存在。由于十氯酮极性较强,在净化时难以洗脱,并且不耐酸,所以不能与其他有机氯农药一起分析。十氯酮在5~100 μg/L范围有良好的线性关系,相关系数r2=0.999,检出限及定量限分别为0.70 ng/L和2.8 ng/L;在5、40和100 ng/L 3个浓度添加水平的平均回收率为95.1%~98.9%,相对标准偏差为3.85%~4.72%。本方法具有良好的灵敏度、回收率和重现性,适用于水环境中十氯酮的测定。  相似文献   

19.
王锦  叶开晓  田艳  刘珂  梁柳玲  李青倩  黄宁  王欣婷 《色谱》2023,41(3):241-249
抗生素作为环境介质中一种典型的新污染物,在各类环境水样中检出频率高且浓度低。为快速、灵敏、准确地分析各类水体中的抗生素,建立了固相萃取-高效液相色谱-串联质谱法(SPE-HPLC-MS/MS)同时测定环境水样中4种青霉素类、12种喹诺酮类和6种大环内酯类共22种抗生素的分析方法。针对抗生素特性和样品基质特点优化前处理方法,重点优化固相萃取柱、水样pH值、水样中乙二胺四乙酸二钠(Na2EDTA)加入量。在200 mL水样中加入0.5 g Na2EDTA,并调节水样的pH值至3,经HLB固相萃取柱富集净化,以乙腈-0.15%(v/v)甲酸水溶液为流动相进行梯度洗脱,采用电喷雾电离源,在正离子模式下使用多反应监测模式进行定性定量分析。结果显示,22种抗生素的相关系数(r)≥0.995,呈现良好的线性关系,方法检出限和定量限分别为2.3~10.7 ng/L和9.2~42.8 ng/L,地表水中3个水平下的加标回收率为61.2%~157%,相对标准偏差(RSD)为1.0%~21.9%,废水中3个水平下的加标回收率为50.1%~129%, RSD为1.2%~16.9%。该方法成功用于水库、地表水、污水处理厂出口、畜禽养殖场等不同类型水样中抗生素的同时测定,其中地表水和畜禽养殖废水中大部分抗生素有检出,在地表水中林可霉素检出率为90%,在畜禽养殖废水中氧氟沙星的检出含量最高,为127 ng/L。该方法检出限和回收率满足定量分析要求,且具有富集水样体积少、分析时间短、适用范围广等优势,特别适用于突发环境污染应急监测,同时为摸清新污染物环境赋存底数和新污染物治理与管控提供有力支撑。  相似文献   

20.
A sensitive assay method was developed for a parallel, rapid and precise determination of dopamine and its metabolites, homovanillic acid, 3-methoxytyramine and 3,4-dihydroxyphenylacetic acid, from brain microdialysates. The method consisted of a pre-treatment step, freeze-drying (lyophilization), to concentrate dopamine and its metabolites from the microdialysates, and a detection step using liquid chromatography combined with electrospray ionization tandem mass spectrometry (LC-ESI-MS/MS). In particular, the reaction monitoring mode was selected for its extremely high degree of selectivity and the stable-isotope-dilution assay for its high precision of quantification. The developed method was characterized by the following parameters: the precision of the developed method was determined as ≥88.6% for dopamine, ≥89.9% for homovanillic acid, ≥86.1% for 3-methoxytyramine and ≥88.1% for 3,4-dihydroxyphenylacetic acid; the mean accuracy was determined as ≥88.2% for dopamine, ≥88.3% for homovanillic acid, ≥85.9% for 3-methoxytyramine and ≥88.6% for 3,4-dihydroxyphenylacetic acid. The developed method was compared to (1) other combinations of pre-treatment methods (solid phase extraction and nitrogen stripping) with LC-MS and (2) another detection method, liquid chromatography, with electrochemical detection. The novel developed method using combination of lyophilization with LC-ESI-MS/MS was tested on real samples obtained from the nucleus accumbens of rat pups after an acute methamphetamine administration. It was proven that the developed assay could be applied to both a simultaneous analysis of all four substrates (dopamine, homovanillic acid, 3-methoxytyramine and 3,4-dihydroxyphenylacetic acid) in microdialysis samples acquired from the rat brain and the monitoring of their slight concentration changes on a picogram level over time following methamphetamine stimulus.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号