共查询到20条相似文献,搜索用时 15 毫秒
1.
In recent years, continuous separation media have attracted considerable attention because of the advantages they offer over packed columns. This research resulted in two useful monolithic material types, the first based on modified silica gel and the second on organic polymers. This work attempts to review advances in the development, characterization, and applications of monolithic columns based on synthetic polymers in capillary chromatography, with the main focus on monolithic beds prepared from methacrylate-ester based monomers. The polymerization conditions used in the production of polymethacrylate monolithic capillary columns are surveyed, with attention being paid to the concentrations of monomers, porogen solvents, and polymerization initiators as the system variables used to control the porous and hydrodynamic properties of the monolithic media. The simplicity of their preparation as well as the possibilities of controlling of their porous properties and surface chemistries are the main benefits of the polymer monolithic capillary columns in comparison to capillary columns packed with particulate materials. The application areas considered in this review concern mainly separations in reversed-phase chromatography, ion-exchange chromatography, hydrophobic and hydrophilic interaction modes; enzyme immobilization and sample preparation in the capillary chromatography format are also addressed. 相似文献
2.
E. N. Viktorova A. Yu. Kanat’eva A. A. Korolev A. A. Kurganov 《Russian Journal of Physical Chemistry A, Focus on Chemistry》2007,81(3):428-432
The effect of the conditions of synthesis of divinylbenzene-based monolithic capillary columns on their chromatographic characteristics was studied. It was demonstrated that the porosity and permeability of the column change significantly even at small deviations from the optimum conditions of polymerization of the monolith in the column. By contrast, the minimum value of HETP proved to be only slightly sensitive to the conditions of synthesis, ranging within ~10–20 μm. The conditions of polymerization of the monolith were found to produce more pronounced effect on the slope of the right branch of the van Deemter curve (parameter C), with the flattest curve being observed for columns prepared under optimum conditions. The minimum value of HETP for polymer monolithic capillary columns was found to be similar to that for silica gel monolithic capillary columns, but the latter are characterized by C values approximately an order of magnitude lower. 相似文献
3.
《Journal of separation science》2003,26(18):1623-1628
Four methacrylate ester‐based monolithic columns for capillary liquid chromatography (CLC) were prepared by radical polymerization with ammonium peroxodisulfate (3 columns) and by thermal initiation (1 column). The polymerization mixture consisted of butyl methacrylate (BMA) and ethylene glycol dimethacrylate (EDMA), propan‐1‐ol, butane‐1,4‐diol, water, and ammonium peroxodisulfate as initiator. It was necessary to add N,N,N′,N ′‐tetramethylethylenediamine (TEMED) to the polymerization mixture to activate the reaction. The amount of initiator and activator was optimized to attain quantitative polymerization. The reproducibility of three columns prepared at ambient temperature was studied. The most efficient column with HETP of 29 μm for uracil was compared to the monolithic column prepared by thermal initiation with α,α′‐azobisisobutyronitrile (AIBN). The efficiencies of all the test columns were characterized by van Deemter curves. Their total porosities were calculated from the retention time of uracil. Walters indices of hydrophobicity (HI) were calculated from the retention factors of anthracene and benzene. The columns prepared by both methods are comparable in their selectivities and efficiencies. They show the same characteristics because their total porosities and Walters indices of hydrophobicity are consistent. However, the preparation of monoliths using ammonium peroxodisulfate was less demanding, because polymerization was possible at ambient temperature. 相似文献
4.
5.
A simple approach to fabricate hybrid monolithic column within the confines of fused-silica capillaries (75 μm i.d.) was introduced. A polyhedral oligomeric silsesquioxanes (POSS) reagent containing a methacrylate group was selected as functional monomer, and copolymerized with bisphenol A dimethacrylate (BPADMA) or ethylene dimethacrylate (EDMA) in the presence of porogenic solvents via thermally initiated free radical polymerization. After optimization of the preparation conditions, two POSS-containing hybrid monoliths were successfully prepared and exhibited good permeability and stability. By comparison of the separation efficiencies of the resulting poly(POSS-co-BPADMA) and poly(POSS-co-EDMA) monoliths in capillary electrochromatography (CEC) and capillary liquid chromatography (cLC), it was indicated the former has better column efficiencies for alkylbenzenes, phenols, anilines and PAHs in CEC and cLC than the latter. Particularly, the hybrid poly(POSS-co-BPADMA) monolith is more suitable for separation of PAHs due to π–π interaction between the analytes and aromatic rings in the surface of monolithic stationary phase. 相似文献
6.
Congying Gu Jun He Jinping Jia Nenghu Fang Robert Simmons Shahab A. Shamsi 《Journal of chromatography. A》2010,1217(4):530-539
A surfactant-bound monolithic stationary phase based on the co-polymerization of 11-acrylamino-undecanoic acid (AAUA) is designed for capillary high performance liquid chromatography (HPLC). Using D-optimal design, the effect of the polymerization mixture (concentrations of monomer, crosslinker and porogens) on the chromatographic performance (resolution and analysis time) of the AAUA–EDMA monolithic column was evaluated. The polymerization mixture was optimized using three proteins as model test solutes. The D-optimal design indicates a strong dependence of chromatographic parameters on the concentration of porogens (1,4-butanediol and water) in the polymerization mixture. Optimized solutions for fast separation and high resolution separation, respectively, were obtained using the proposed multivariate optimization. Differences less than 6.8% between the predicted and the experimental values in terms of resolution and retention time indeed confirmed that the proposed approach is practical. Using the optimized column, fast separation of proteins could be obtained in 2.5 min, and a tryptic digest of myoglobin was successfully separated on the high resolution column. The physical properties (i.e., morphology, porosity and permeability) of the optimized monolithic column were thoroughly investigated. It appears that this surfactant-bound monolith may have a great potential as a new generation of capillary HPLC stationary phase. 相似文献
7.
A. A. Korolev V. E. Shiryaeva T. P. Popova A. A. Kurganov 《Russian Journal of Physical Chemistry A, Focus on Chemistry》2014,88(9):1609-1612
Relative polarity values and retention indices for a mixture of normal paraffins C5–C10 and alkylbezenes C6–C9 are determined for four types of monolithic capillary columns based on divinylbenzene, ethylene glycol dimethacrylate, pentaerythritol tetraacrylate, and pentaerythritol triacrylate. It is established that the retention of polar sorbates increases with a rise in stationary phase polarity, while the retention of nonpolar compounds grows with a reduction in stationary phase polarity. 相似文献
8.
Takeuchi T Tatsumi S Masuoka S Hirose K Uzu H Jin JY Fujimoto C Ohta K Lee KP Ryoo JJ Choi SH 《Journal of chromatography. A》2003,1021(1-2):55-59
Split flow and bypass flow systems were assembled using Nano Y Connectors with low dead volume commercially available for capillary liquid chromatography (LC). The split ratio could be controlled by changing the dimension of restriction tubing and applied back pressure to the restriction tubing. The split flow system allowed us to use valve injectors and pumps commercially available for capillary LC. The reproducibility of the present split flow system was acceptable. The relative standard deviation for six successive measurements was 0.4% for the retention time, whereas that for the peak height and peak area was 1-3% depending on the analytes. The bypass flow system uses two Nano Y Connectors, where the eluent split at the first Nano Y Connector, which is located in the inlet of the separation column, is merged again into the effluent from the column at the second Nano Y Connector. The bypass flow system could avoid on-column detection and allowed us to use flow cells, leading to an approximate three times improvement in signal-to-noise. The present flow systems were evaluated by using aromatic hydrocarbons and alkylbenzenes as test analytes. 相似文献
9.
Summary Fused silica capillaries, ≈ 130 × 0.32mm have been packed with small reversed phase spherical silica particles, 3 or 2μm,
in order to achieve LC-systems giving high plate numbers at relatively low pressure drop in short analysis times. At optimal
conditions, columns packed with 3μm particles showed reduced plate heights, h, around 2.5, and the column flow resistance,
ϕ, was 335–625. With 2μm particles, a reduced plate height of only 3.7 was achieved, which reflects the difficulty in the
packing of such small particles. 相似文献
10.
Capillary electrochromatography (CEC) was used to separate alkyl phenol ethoxylates (APEs) as model diblock copolymers, with monolithic polymers as stationary phases. The order of elution indicate that the two polymer blocks follow distinct chromatographic modes: size-exclusion for the poly(oxyethylene) group and adsorption interaction for the alkyl part. Therefore, our experimental results were compared to the theory describing liquid exclusion-adsorption chromatography (LEAC). They were found in perfect agreement with the theory, which turned to be verified for the first time over the full range of polymer lengths. 相似文献
11.
Coufal P Cihák M Suchánková J Tesarová E Bosáková Z Stulík K 《Journal of chromatography. A》2002,946(1-2):99-106
Monolithic capillary columns (320 microm I.D.) were prepared for capillary liquid chromatography (CLC) by radical polymerization of butylmethacrylate (BMA) and ethylenedimethacrylate (EDMA) in the presence of a porogen solvent containing propan-1-ol, butane-1,4-diol and water. The influence of the contents of the porogen solvent and EDMA in the polymerization mixture on the monolith porosity and column efficiency was investigated. The composition of the polymerization mixture was optimized to attain a minimum HETP of the order of tens of microm for test compounds with various polarities. The separation performance and selectivity of the most efficient monolithic column prepared was characterized by van Deemter curves, peak asymmetry factors and Walters hydrophobicity and silanol indices. It was demonstrated that the 320-microm I.D. monolithic column exhibited CLC separation performance similar to that observed for 100- and 150-microm I.D. monolithic columns reported in the literature; moreover, the 320-microm I.D. column was easier to operate in CLC and exhibited a higher sample loadability. 相似文献
12.
In this study, divinylbenzene (DVB) was used as the cross-linker to prepare alkyl methacrylate (AlMA) monoliths for incorporating π-π interactions between the aromatic analytes and AlMA-DVB monolithic stationary phases in capillary LC analysis. Various AlMA/DVB ratios were investigated to prepare a series of 30% AlMA-DVB monolithic stationary phases in fused-silica capillaries (250-μm i.d.). The physical properties (such as porosity, permeability, and column efficiency) of the synthesized AlMA-DVB monolithic columns were investigated for characterization. Isocratic elution of phenol derivatives was first employed to evaluate the suitability of the prepared AlMA-DVB columns for small molecule separation. The run-to-run (0.16–1.20%, RSD; n = 3) and column-to-column (0.26–2.95%, RSD; n = 3) repeatabilities on retention times were also examined using the selected AlMA-DVB monolithic columns. The π-π interactions between the aromatic ring and the DVB-based stationary phase offered better recognition on polar analytes with aromatic moieties, which resulted in better separation resolution of aromatic analytes on the AlMA-DVB monolithic columns. In order to demonstrate the capability of potential environmental and/or food safety applications, eight phenylurea herbicides with single benzene ring and seven sulfonamide antibiotics with polyaromatic moieties were analyzed using the selected AlMA-DVB monolithic columns. 相似文献
13.
A novel monolithic capillary column (530 microm i.d.) was prepared for capillary liquid chromatography (CLC) by in situ copolymerization of octyl methacrylate (MAOE) and ethylene dimethacrylate (EDMA) in the presence of a porogen solvent containing 1-propanol, 1,4-butanediol, and water with azobisisobutyronitrile as the initiator. The influences of the contents of the porogen solvent, EDMA and the various concentration ratios of 1-propanol to 1,4-butanediol in the polymerization mixture on the morphology, porosity, globule size, stability and column efficiency were investigated. The morphology and pore size distribution of monolithic capillary columns were characterized by SEM and mercury intrusion porosimetry, respectively. Chromatographic evaluations of the columns were performed under CLC mode. The results showed that good permeability and stability can be obtained under optimal experimental conditions. The separation results of some acid, neutral and basic analytes demonstrated the hydrophobicity and low affinity to basic analytes of the new column. Three metal ions, i.e. Mg(II), Zn(II) and Cd(II) were also separated under ion-pair mode on the new monolithic capillary column and the results were acceptable. 相似文献
14.
The present work aims at the optimisation of the synthesis of methyl-silsesquioxane monolithic capillary columns using a sol-gel based protocol. The influence of reaction conditions such as temperature, reaction mixture composition and catalyst concentration has been examined. The morphology of the products was studied by scanning electron microscopy and nitrogen adsorption. Monolithic capillary columns were obtained with a skeleton-like structure with open pores. Pore diameters vary from 0.8 to 15 microm, diameters of the xerogel network vary from 0.4 to 12 microm, respectively. Specific surface areas up to 334 m2/g have been observed, however, many materials did not possess areas above few m2/g which represents the limit of detection of the nitrogen porosimetry measurements. Excellent adhesion to the capillary wall was observed in all cases, and drying was possible at ambient conditions without the formation of cracks. 相似文献
15.
Eeltink S Desmet G Vivó-Truyols G Rozing GP Schoenmakers PJ Kok WT 《Journal of chromatography. A》2006,1104(1-2):256-262
A method is proposed for the comprehensive characterization and comparison of columns in the high-performance liquid chromatographic (HPLC) and capillary electrochromatographic (CEC) modes. Using this approach, column parameters such as the number of plates, the eddy-diffusion and mass-transfer contributions to peak broadening, the permeability, and the analysis time are incorporated in a single graph and a comparison in terms of efficiency and speed is obtained. The chromatographic performance of silica-based and polymer-based monolithic capillary columns is discussed and a comparison is made with the performance of packed columns. Also, the potential of ultra-high-pressure liquid chromatography is discussed in this context. In the HPLC mode, the best results were obtained with silica monoliths; in the CEC mode, the low-density methacrylate-ester-based monoliths showed the best performance. 相似文献
16.
Schlemmer B Bandari R Rosenkranz L Buchmeiser MR 《Journal of chromatography. A》2009,1216(13):2664-2670
Monolithic capillary columns were prepared via electron beam triggered free radical polymerization within the confines of 0.2 and 0.1mm I.D. capillary columns using ethyl methacrylate and trimethylolpropane triacrylate as monomers as well as 2-propanol, 1-dodecanol and toluene as porogenic system. The influence of column diameter on reproducibility and separation performance was investigated. For evaluation, a protein standard consisting of five proteins in the range of 5800-66,000 g mol(-1) was used. Reproducibility was checked by determining the relative standard deviations in retention times, peak widths at half height, asymmetry and resolution. Excellent run-to-run reproducibility was found for both 0.2 and 0.1mm I.D. columns; batch-to-batch reproducibility was good for both column types. In order to enhance the non-polar character of the monolithic columns, lauryl methacrylate-based capillary columns were prepared. These were successfully used for the separation of proteins and a cytochrome c digest. 相似文献
17.
Capillary liquid chromatography (cLC) has great potential for protein and peptide separation, with advantages of high efficiency, high resolution, low sample consumption, and high sensitivity when coupled with mass spectrometry. In recent years, monoliths have been widely used as the stationary phases for capillary columns, owing to easy preparation, high permeability, fast mass transfer, and low backpressure. This review summarizes recent advances (2007–2012) in monolithic columns for protein and peptide separation by cLC. After a brief introduction on the preparation of monolithic capillary columns, the emphasis of this review is focused on the recent application of such columns for protein and peptide separation by cLC. Furthermore, the challenges and potential hot points of monolithic capillary columns in the future are discussed. 相似文献
18.
Pavel Jandera Jiří Urban Veronika Škeříková Pavel Langmaier Romana Kubíčková Josef Planeta 《Journal of chromatography. A》2010,1217(1):22-33
We prepared hybrid particle-monolithic polymethacrylate columns for micro-HPLC by in situ polymerization in fused silica capillaries pre-packed with 3–5 μm C18 and aminopropyl silica bonded particles, using polymerization mixtures based on laurylmethacrylate–ethylene dimethacrylate (co)polymers for the reversed-phase (RP) mode and [2-(methacryloyloxy)ethyl]-dimethyl-(3-sulfopropyl) zwitterionic (co)polymers for the hydrophilic interaction (HILIC) mode. The hybrid particle-monolithic columns showed reduced porosity and hold-up volumes, approximately 2–2.5 times lower in comparison to the pure monolithic columns prepared in the whole volume of empty capillaries. The elution volumes of sample compounds are also generally lower in comparison to packed or pure monolithic columns. The efficiency and permeability of the hybrid columns are intermediate in between the properties of the reference pure monolithic and particle-packed columns. The chemistries of the embedded solid particles and of the interparticle monolithic moiety in the hybrid capillary columns contribute to the retention to various degrees, affecting the selectivity of separation. Some hybrid columns provided improved separations of proteins in comparison to the reference particle-packed columns in the reversed-phase mode. Zwitterionic hybrid particle-monolithic columns show dual mode retention HILIC/RP behaviour depending on the composition of the mobile phase and allow separations of polar compounds such as phenolic acids in the HILIC mode at lower concentrations of acetonitrile and, often in shorter analysis time in comparison to particle-packed and full-volume monolithic columns. 相似文献
19.
Over the last decade, monoliths or continuous beds have emerged as an alternative to traditional packed-bed columns for use in capillary electrochromatography (CEC) and micro-high performance liquid chromatography (micro-HPLC). Monolithic columns can be divided into two categories: silica-based monolithic columns and rigid organic polymer-based monolithic columns resulting from the polymerization of acrylamide, styrene, acrylate or methacrylate monomers. In this paper, the chemistry and most recent applications of these various types of monoliths in both CEC and micro-HPLC are presented. 相似文献
20.
Freitag R 《Journal of chromatography. A》2004,1033(2):267-273
Porous monoliths based on N,N-dimethylacrylamide (DMAA) or methacrylamide (MAA) were prepared inside fused silica capillaries as stationary phases for nano-chromatography. The columns were characterized in terms of flow rate and backpressure and showed, e.g. differences as a function of the salt concentration added to the polymerization mixture. When the columns were investigated for the separation of uncharged (polar hydroxylated aromatic compounds) and charged (amino acids) analytes under pressure driven conditions (pLC), differences to the previously observed behavior under voltage driven conditions (CEC) were observed. Whereas the non-charged analytes showed similar behavior in both cases--thus, corroborating the previous assumption of a mainly chromatographic separation mode driven by hydrophilic interactions in CEC--the charged amino acids did not. Assuming that the separation was governed by chromatographic phenomena in the pLC mode and by both chromatographic and electrophoretic effects in the CEC mode, the experiments allowed deconvoluting the two contributions. In particular, the charged amino acids appeared to interact with the stationary phases mainly by electrostatic interactions modified by some hydrophilic effects. 相似文献