首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
An experimental setup is presented here for the automated analysis of microsamples, based on the on-line coupling of a capillary SPE module and a CE unit using a two-position six-port valve, an open-closed valve to isolate electrically the sample preparation from the CE unit and a "T" interface. A C18 trapping microcolumn (dimensions 2.5 cm x 100 microm id x 360 microm od) was used for the SPE step. The utility of the proposed experimental setup was demonstrated by applying it to the determination of quinolone antibiotics in serum microsamples, which was efficiently carried out in less than 20 min (4 min for protein denaturation and 15 min for analytes preconcentration and CE-UV separation-determination). A complete optimization study was performed for preconcentration and cleanup of quinolones, the coupling of sample preparation module to the CE unit and electrophoretic separation of quinolones. A preconcentration factor of 10.4 was achieved. The volume injected with the proposed method was 125 nL versus 160 nL introduced by hydrodynamic injection. The volume required for the analysis was 2 microL, which makes the proposed experimental setup very useful for the analysis of microsamples in fields of current interest such as metabolomics or proteomics.  相似文献   

2.
New strategies for rapid, sensitive and high-throughput analysis of low abundance metabolites in biological samples are required for future metabolomic research. In this report, a direct method for sub-micromolar analyses of phosphoamino acids was developed using on-line sample preconcentration with 9-fluorenylmethyloxycarbonyl chloride (FMOC) derivatization by capillary electrophoresis (CE) and UV detection. Analyte focusing by dynamic pH junction and FMOC labeling efficiency were influenced by several experimental factors including buffer pH, ionic strength, sample injection length and FMOC concentration. About a 200-fold enhancement in concentration sensitivity was achieved under optimal conditions relative to conventional off-line derivatization, as reflected by a detection limit (S/N approximately 3) of 0.1 microM. In-capillary sample preconcentration with chemical labeling by CE offers a unique single-step analytical platform for high-throughput screening of low abundance metabolites without intrinsic chromophores.  相似文献   

3.
Yin XB 《Electrophoresis》2004,25(12):1837-1842
An on-line preconcentration method was developed for capillary electrophoresis (CE) with hydride generation-atomic fluorescence spectrometric (HG-AFS) detection of arsenite, arsenate, dimethylarsenic acid, and monomethylarsenic acid. These arsenic species were negatively charged in the sample solution with high pH. When the potential was applied to the electrophoretic capillary, the negatively charged analyte ions moved faster and stacked at the boundary of sample and CE buffer with low pH. So, high sample pH in combination with low buffer pH allowed the injection of large sample volumes (approximately 1100 nL). Comparison of the preconcentration of analyte solution, prepared with doubly deionized water and that prepared with lake or river water, indicated that preconcentration was independent on the original matrix. With injection of approximately 1100 nL sample, an enrichment factor of 37-50-fold was achieved for the four species. Detection limits for the four arsenic species ranged from 5.0 to 9.3 microg.L(-1). Precisions (RSDs, n = 5) were in the range of 4.9-6.7% for migration time, 4.7-11% for peak area, and 4.3-7.1% for peak height, respectively. The recoveries of the four species in locally collected water solution spiked with 0.1 microg.mL(-1) (as As) ranged from 83 to 109%.  相似文献   

4.
A method based on poly (methacrylic acid‐co‐ethylene glycol dimethacrylate) monolith microextraction and octadecylphosphonic acid‐modified zirconia‐coated CEC followed by field‐enhanced sample injection preconcentration technique was proposed for sensitive CE‐UV analysis of six antidepressants (doxepin, clozapine, imipramine, paroxetine, fluoxetine and chlorimipramine) in human plasma and urine. A poly(methacrylic acid‐co‐ethylene glycol dimethacrylate) monolithic capillary column was introduced for the extraction of antidepressants from urine and plasma samples. The hydrophobic main chains and acidic pendant groups of the monolithic column make it a superior material for extraction of basic analytes from aqueous matrix. After extraction, the desorption solvent, which normally provided an excellent medium to ensure direct compatibility for field‐enhanced sample injection in CE, was analyzed by CE directly. By the use of alkylphosphonate‐modified zirconia‐coated CEC for separation of the basic compounds of antidepressants, high separation efficiency and resolution were achieved because that both hydrophobic interaction between analytes and alkylphosphonate‐modified zirconia coat and electrophoretic effect work on the separation of antidepressants. The best separation was achieved using a buffer composed of 0.3 M ammonium acetate (adjusted to pH 4.5 with 1 M acetic acid) and 35% ACN v/v, with a temperature and voltage of 20°C and 20 kV, respectively. By applying both preconcentration procedures, LODs of 11.4–51.5 and 3.7–17.0 μg/L were achieved for the six antidepressants in human plasma and urine, respectively. Excellent method of reproducibility was found over a linear range of 50–5000 μg/L in plasma and urine sample.  相似文献   

5.
Protein A-coated magnetic beads (0.3 mum) have been trapped in a small portion of a neutrally coated capillary (50 mum id). Anti-beta-lactoglobulin (beta-LG) antibodies have then been immobilized on the beads through strong affinity with protein A to subsequently capture beta-LG from model or real samples. Once the immunocomplexes formed at physiological pH, a discontinuous buffer system has been used to release the partners and preconcentrate them by transient ITP. The antigens and antibodies have finally been separated by CZE and detected by UV absorbance. An LOQ of 55 nM has been achieved. This methodology has been applied to quantify native beta-LG in pasteurized and ultra-high-temperature-treated bovine milk. All the described procedures, including immunosorbent preparation, sample extraction, cleanup, preconcentration, and separation are completely automated on a commercial CE instrument. As this CE immunoassay method is simple, rapid, selective, and sensitive, it should be a practical and attractive technology for the analysis of complicated biological samples.  相似文献   

6.
Zhang H  Zhou L  Chen X 《Electrophoresis》2008,29(7):1556-1564
An easy, simple, and highly efficient on-line preconcentration method for polyphenolic compounds in CE was developed. It combined two on-line concentration techniques, large-volume sample stacking (LVSS) and sweeping. The analytes preconcentration technique was carried out by pressure injection of large-volume sample followed by the EOF as a pump pushing the bulk of low-conductivity sample matrix out of the outlet of the capillary without the electrode polarity switching technique using five polyphenols as the model analytes. Identification and quantification of the analytes were performed by photodiode array UV (PDA) detection. The optimal BGE used for separation and preconcentration was a solution composed of 10 mM borate-90 mM sodium cholate (SC)-40% v/v ethylene glycol, without pH adjustment, the applied voltage was 27.5 kV. Under optimal preconcentration conditions (sample injection 99 s at 0.5 psi), the enhancement in the detection sensitivities of the peak height and peak area of the analytes using the on-line concentration technique was in the range of 18-26- and 23-44-fold comparing with the conventional injection mode (3 s). The detection limits for (-)-epigallocatechin (EGC), (-)-epicatechin (EC), (+)-catechin (C), (-)-epigallocatechin gallate (EGCG), and (-)-epicatechin gallate (ECG) were 4.3, 2.4, 2.2, 2.0, and 1.6 ng/mL, respectively. The five analytes were baseline-separated under the optimum conditions and the experimental results showed that preconcentration was well achieved.  相似文献   

7.
A new on-line preconcentration technique was developed that makes possible to determine nanomolar concentrations of weak acidic analytes in CE. The method consists of long-running electrokinetic sample injection and stacking (electrokinetic immobilization) of the analytes at a boundary of two electrolytes with different pH values (pH 9.5 and 2.5) and consequent mobilization of the stacked uncharged analytes in a micellar system (containing SDS micelles). Several factors including buffer concentration, pH, applied voltage, time of preconcentration, and SDS concentration were tested to optimize the analysis method. An about 4600-fold increase of the sample concentration (in comparison with the standard CZE) can be achieved during the preconcentration step. Two preservatives applied in food industry -- benzoic acid and sorbic acid were used as model samples. The applicability of the proposed method in food analysis was demonstrated by determination of nanomolar concentrations of benzoic acid in sunflower oil. An extended version of the computer program Simul was used for modeling both the preconcentration and mobilization processes taking place in the capillary.  相似文献   

8.
Rapid and direct online preconcentration followed by CE with capacitively coupled contactless conductivity detection (CE‐C4D) is evaluated as a new approach for the determination of glyphosate, glufosinate (GLUF), and aminophosphonic acid (AMPA) in drinking water. Two online preconcentration techniques, namely large volume sample stacking without polarity switching and field‐enhanced sample injection, coupled with CE‐C4D were successfully developed and optimized. Under optimized conditions, LODs in the range of 0.01–0.1 μM (1.7–11.1 μg/L) and sensitivity enhancements of 48‐ to 53‐fold were achieved with the large volume sample stacking‐CE‐C4D method. By performing the field‐enhanced sample injection‐CE‐C4D procedure, excellent LODs down to 0.0005–0.02 μM (0.1–2.2 μg/L) as well as sensitivity enhancements of up to 245‐ to 1002‐fold were obtained. Both techniques showed satisfactory reproducibility with RSDs of peak height of better than 10%. The newly established approaches were successfully applied to the analysis of glyphosate, glufosinate, and aminophosphonic acid in spiked tap drinking water.  相似文献   

9.
黄林芳  何蔓  陈贝贝  胡斌 《色谱》2014,32(10):1066-1078
毛细管电泳(CE)具有分析速度快、分离效率高、样品消耗少、成本低廉等优点,已被应用于无机离子、有机小分子、蛋白质、核酸及细胞等的分析中。CE中最常用的检测方式是紫外检测(UV),但由于常规进样样品体积小、检测光程短,CE-UV的灵敏度往往不能满足复杂样品中痕量物质直接分析的要求。CE中的在柱富集技术包括堆积、动态pH界面、吹扫和瞬间等速电泳等,可在很大程度上提高CE-UV的检测灵敏度;另外,固相和液相微萃取技术及其与在柱富集技术相结合应用在CE中也能净化样品基质,进一步提高富集倍数,改善分析灵敏度,从而拓宽了CE-UV在复杂样品分析中的应用范围。  相似文献   

10.
An analytical method of CE-MS and CE with an online preconcentration technique induced by a dynamic pH junction, addition of organic solvent and large volume injection was developed for sensitive determination of peptides in biological samples. Leucine enkephalin, methionine enkephalin, dynorphin A, β-endorphin and angiotensin II were used as model peptides. The optimal online preconcentration conditions were obtained at a sample matrix consisting of 100?mM borate buffer (pH 10.0) with 50% v/v acetonitrile and a BGE containing 1?M formic acid at pH 2.0, along with a 25-cm injection length. Under the optimized conditions, a 4.0×10(3)-1.1×10(4)-fold increase in peak intensity was achieved without degrading the peak shape. This online preconcentration method was applied to analyze the intracellular angiotensin II within the peptides extracted from HL1 cells and approximately increase of 1×10(4)-fold sensitivity was achieved compared to normal condition. Thus, the developed method could be applied to the analysis of various peptides for peptidomics study in biological samples.  相似文献   

11.
Electrokinetic supercharging (EKS) combines field-amplified sample injection with transient isotachophoresis (tITP) to create a powerful on-line preconcentration technique for capillary electrophoresis. In this work, EKS is enhanced with a positive pressure (pressure-assisted EKS, or PA-EKS) during injection to improve stacking of non-steroidal anti-inflammatory drugs (NSAIDs). Several parameters, including buffer composition and concentration, terminating electrolyte, organic modifier, and injection voltage and injection time of both terminating electrolyte and sample were optimized. Detection limits for seven NSAIDs were determined and an enhancement in sensitivity of almost 50,000-fold was obtained. The PA-EKS method has the potential to be a simple MS compatible preconcentration method to improve the sensitivity of CE.  相似文献   

12.
Single drop microextraction (SDME) is a convenient and powerful preconcentration method for CE before injection. By simple combination of sample‐handling sequences without modification of the CE apparatus, a drop of an aqueous acceptor phase covered with a thin organic layer was formed at the tip of a capillary; 10 min SDME of fluorescein and 6‐carboxyfluorescein from a donor phase of pH 1 to an acceptor phase of pH 9 provided 110‐fold enrichments without stirring the donor phase. To improve the concentration effect further, SDME was coupled with an on‐line (after injection) sample preconcentration method, sweeping, in which analytes in a long sample zone are accumulated at the boundary of a pseudostationary phase penetrating into the sample zone. It is thus necessary to inject a sample of much larger volume than that of a drop in typical SDME. A Teflon sleeve over the capillary inlet allowed a large volume drop to be held stably during extraction. By in‐line coupling 10 min SDME and sweeping of a 30 nL sample using a cationic surfactant dodecyltrimethylammonium, enrichment factors of the double preconcentration were increased up to 32 000.  相似文献   

13.
An on-line preconcentration capillary electrophoresis (CE) technique, which combines a large volume sample stacking with a dynamic pH junction technique, is introduced in this paper. This dynamic pH junction with co-electroosmotic migration is formed between sodium borate pH 9.5 and sodium phosphate pH 2.5 with 150 mM sodium dodecylsulfate (SDS). A full capillary based injection allows determination of weak acidic compounds at ppb concentration levels (achieved LOD for benzoic acid was 11 nmol L(-1)). The proposed preconcentration method was compared with ITP/ITP (LOD 120 nmol L(-1)), ITP/CZE (LOD 740 nmol L(-1)) and a simple CZE method (LOD 23,330 nmol L(-1)). The analytical potential of this method was assessed with juice test samples.  相似文献   

14.
Simple, selective yet sensitive methods to quantify low-abundance bacterial biomarkers derived from complex samples are required in clinical, biological, and environmental applications. In this report, a new strategy to integrate sample pretreatment with chemical analysis is investigated using on-line preconcentration with chemical derivatization by CE and UV detection. Single-step enantioselective analysis of muramic acid (MA) and diaminopimelic acid (DAP) was achieved by CE via sample enrichment by dynamic pH junction with ortho-phthalaldehyde/N-acetyl-L-cysteine labeling directly in-capillary. The optimized method resulted in up to a 100-fold enhancement in concentration sensitivity compared to conventional off-line derivatization procedures. The method was also applied toward the detection of micromolar levels of MA and DAP excreted in the extracellular medium of Escherichia coli bacterial cell cultures. On-line preconcentration with chemical derivatization by CE represents a unique approach for conducting rapid, sensitive, and high-throughput analyses of other classes of amino acid and amino sugar metabolites with reduced sample handling, where the capillary functions simultaneously as a concentrator, microreactor, and chiral selector.  相似文献   

15.
A method for the in-line preconcentration and enantioseparation of clenbuterol by transient isotachophoresis-capillary zone electrophoresis-UV absorbance detection (transient ITP-CZE-UV) has been developed. It implies the use of dimethyl-beta-cyclodextrin as chiral selector and the application of a hydrodynamic counterflow during the ITP step. ITP is used to focus the sample constituents prior to CE whereas a counterpressure counterbalances the electrophoretic migration of the compounds. The sample is then focused and kept stationary in the proximity of the capillary inlet before CZE separation, leading to an extended-volume ITP-CZE system. A new strategy for the fast optimization of the counterpressure has been developed which implies the measurement of the hydrodynamic and electrophoretic velocities of the analyte during ITP. The in-line preconcentration and enantioseparation of clenbuterol selected as model compound was optimized using this method. Salbutamol was chosen as internal reference in order to check the reproducibility of the method. A 173-nl volume of aqueous ample solution was injected which implies an improvement of the injection volume of about 16 and a resolution of 4.8 was obtained for the clenbuterol enantiomers. A concentration detection limit of 10(-6) mol/l was readily achieved for clenbuterol and salbutamol using only 3 min ITP preconcentration in in-line counterflow transient ITP-CZE-UV. Thanks to its fast optimization, the method is applicable to any enantioseparation by means of only five very short preliminary measurements.  相似文献   

16.
The popularity of ionic liquids (ILs) has grown during the last decade in enhancing the sensitivity of CE through different off‐line or on‐line sample preconcentration techniques. Water‐insoluble ILs were commonly used in IL‐based liquid phase microextraction, in all its variants, as off‐line sample preconcentration techniques combined with CE. Water‐soluble ILs were rarely used in IL‐based aqueous two phase system (IL‐ATPS) as an off‐line sample preconcentration approach combined with CE in spite of IL‐ATPS predicted features such as more compatibility with CE sample injection due to its relatively low viscosity and more compatibility with CE running buffers avoid, in some cases, anion exchange precipitation. Therefore, the attentions for the key parameters affecting the performance of IL‐ATPSs were generally presented and discussed. On‐line CE preconcentration techniques containing IL‐based surfactants at nonmicellar or micellar concentrations have become another interesting area to improve CE sensitivity and it is likely to remain a focus of the field in the endeavor because of their numerous to create rapid, simple and sensitive systems. In this article, significant contributions of ILs in enhancing the sensitivity of CE are described, and a specific overview of the relevant examples of their applications is also given.  相似文献   

17.
An effective sample preconcentration technique for proteins and peptides was recently developed using capillary electrophoresis (CE) with discontinuous buffers [C.A. Nesbitt, J.T.-M. Lo, K.K.-C. Yeung, J. Chromatogr. A 1073 (2005) 175]. Two buffers of different pH created a junction to trap the sample molecules at their isoelectric points and resulted in over 1000-fold preconcentration for myoglobin within 30 min. To study the formation of pH junctions in CE, a pH indicator, bromothymol blue, is used in this work to reveal the pH changes at the discontinuous buffer boundary. Bromothymol blue (BTB) exhibits a drastic change in its visible absorption spectrum (300-600 nm) going from the acidic to basic pH conditions, and is therefore ideal for visualizing the changes in pH at the junctions created by various buffer combinations. Preconcentration of myoglobin was performed in discontinuous buffers containing BTB. Major differences in the BTB absorption profiles were identified from buffer systems that differ significantly in preconcentration performance, which in turn, allowed for the identification of ideal buffers for sample preconcentration. Up to 2000-fold preconcentrations of myoglobin were achieved in the buffer systems studied in this work. In addition, the role of the electroosmotic flow (EOF) on the preconcentration performance was investigated. A low EOF was found to be desirable, as the pH junction could stay longer in the capillary for accumulation of proteins. The pH junction also displayed characteristics to resist bandbroadening. Potential laminar flow resulted from the mismatched residual EOFs under the two pH conditions within the discontinuous buffers appeared to have minimal effect on the preconcentration. In fact, external applied pressure can be used to control the migration of the pH junction without compromising the protein preconcentration.  相似文献   

18.
In the present paper a capillary zone electrophoresis (CZE)-compatible preconcentration technique for anions, based on ion exchange, is described. The described preconcentration approach has found limited use until recently because of the inherent elution step that leads to contamination of the sample with eluent components. In this paper, we describe an improved anion exchange-based preconcentration technique in which contamination of the sample with the eluent constituents, which occurs during anion elution from the preconcentration column, is eliminated by on-line chemical suppression on a packed-bed suppressor column. In the present communication, the basic principles of the proposed anion enrichment system are presented. The system was optimized, resulting in a minimal additional dilution of the eluted sample plug. This was achieved by the use of a computer-controlled, sensing/switching system. The effectiveness of the developed method was later tested on the determination of some anions in a synthetic sample using CE apparatus.  相似文献   

19.
A capillary electrophoretic (CE) method with UV detection at 278 nm has been developed for analysis of the immunosuppressant rapamycin (sirolimus) in human blood at low microg.L(-1) levels. Separation has been achieved in an acidic carrier electrolyte containing sodium dodecyl sulfate and 20% v/v methanol. For sample cleanup and preconcentration, both an off-line solid-phase extraction step using a silica-based reversed-phase material and a newly developed on-capillary focusing technique have been employed. The subsequent treatment of rapamycin under alkaline conditions leads to a cleavage of the lacton bond of the molecule, generating a negatively charged carboxylic group which allows electrokinetic injection into the CE instrument. During the injection process, the negatively charged analyte migrates into an acidic carrier electrolyte, so that it becomes neutral due to protonation and is focused at the capillary inlet. Injection times of 300 s at -7.5 kV could be applied without band-broadening. Results for real samples indicated that the method is fully suited for routine applications and may be an attractive alternative to established liquid chromatographic techniques.  相似文献   

20.
Sweeping in capillary electrophoresis (CE) involves the interaction of a pseudostationary phase (PS) in the separation solution and a sample in the matrix that is free of the PS used. The PS includes not only the PSs employed in electrokinetic chromatography, but also complexation reagents such as borate. The sample matrix could have a lower, similar, or higher conductance than the separation solution. Thus, the basic condition for sweeping is a sample matrix free of the additive. The accumulation of analyte molecules during the interaction makes this interesting phenomenon very useful as an on-line preconcentration method for CE. Preconcentration occurs due to chromatographic partitioning, complexation, or any interaction between analytes and PS. Contact between analyte and PS is facilitated by the action of electrophoresis and is independent of electroosmosis. The analyte, PS, or both should have electrophoretic velocities when an electric field is applied. The extent of preconcentration is dictated by the strength of the interaction involved. From tens to several thousand-fold improvements in detector response for many neutral and charged analytes have been achieved with this technique, suggesting sweeping as a general approach to on-line preconcentration in CE. The mechanism and applications of the sweeping phenomenon under different experimental conditions are discussed in this review, with particular emphasis on a better understanding of the sweeping mechanism under reduced electric field (high conductivity) in the sample zone.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号