首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 62 毫秒
1.
A liquid chromatography/electrospray ionization tandem mass spectrometric method for analyzing organophophorus flame retardants and plasticizers in drinking and environmental waters was developed. Five alkyl phosphates, three chlorinated alkyl phosphates, two aryl phosphate and triphenylphosphine oxide were selected for this study. These compounds were extracted from water samples by a hydrophilic polymeric solid-phase extraction cartridge. Accuracy and precision were evaluated analyzing 0.5 L of water samples spiked at concentrations of 10 and 100 ng/L for drinking water and at 300 and 1000 ng/L for river water. Except for trimethyl phosphate, analyte recoveries were better than 80%, and were not dependent on the type of aqueous matrix in which they were dissolved. At the spike levels considered, within-day precision was between 3 and 12% for tap water and between 4 and 14% for river water, and estimated method quantification limits ranged from 0.2 to 3.9 ng/L. A short survey conducted by analyzing some river water samples (River Tiber) ascertained the presence of ten organophosphorus compounds at concentration levels ranging from a few nanograms per liter to 323 ng/L for tris(2-butoxyethyl) phosphate.  相似文献   

2.
This paper describes a method for determining 11 pharmaceuticals in various water sources by SPE followed by LC-(ESI) MS. SPE was carried out with Oasis HLB and the recoveries were 33-67% for 250 and 100 mL sewage water, 55-77% for 500 mL river water and 72-98% for 1 L tap water, with the exception of sulfamethoxazole and omeprazole which showed lower recoveries in all kinds of sample. The LODs in river water were of 5 ng/L for sulfadiazine, trimethoprim, sulfamethazine, sulfamethoxazole, and ranitidine and 10 ng/L for the other compounds. The highest concentrations found in river waters were for sulfamethoxazole (50 ng/L). In influent sewage waters, ranitidine was the most commonly detected compound with a maximum value of 0.24 microg/L.  相似文献   

3.
Iodinated contrast media belong to the most frequently applied compounds in medicine. They exhibit a high polarity and are very persistent against metabolism by the organism and environmental degradation. A sensitive method for the determination of five iodinated contrast media in aqueous matrices is described. Solid phase extraction utilizing Isolute ENV+ material was used for sample enrichment. The contrast media were partially separated on a RP-C18 column, and detection was achieved using electrospray-tandem MS (API III plus and API 365) allowing the sensitive quantitation of these compounds down to the lower ng/L range. The recovery rates generally exceeded 70%, for spiked surface water as well as tap water. The analytes were detected in native samples such as municipal sewage treatment plant (STP) effluent, the river Rhine and even in tap water.  相似文献   

4.
Iodinated contrast media belong to the most frequently applied compounds in medicine. They exhibit a high polarity and are very persistent against metabolism by the organism and environmental degradation. A sensitive method for the determination of five iodinated contrast media in aqueous matrices is described. Solid phase extraction utilizing Isolute ENV+ material was used for sample enrichment. The contrast media were partially separated on a RP-C18 column, and detection was achieved using electrospray-tandem MS (API III plus and API 365) allowing the sensitive quantitation of these compounds down to the lower ng/L range. The recovery rates generally exceeded 70%, for spiked surface water as well as tap water. The analytes were detected in native samples such as municipal sewage treatment plant (STP) effluent, the river Rhine and even in tap water.  相似文献   

5.
There is increasing interest in and demand for simultaneously monitoring pesticides as well as related degradation products (DPs) in natural waters, as the latter compounds can be even more toxic than the former ones. A method for determining parts per trillion levels of phenylurea herbicides and their DPs, that is their dealkylated forms and aromatic amines, is described. This method is based on solid-phase extraction with a Carbograph 4 cartridge followed by liquid chromatography (LC) with electrospray (ES) mass spectrometric detection. A study aimed at optimizing the response of the ES-MS detector for very weakly basic chloroanilines was conducted. Results showed that ion signal intensities of the above species were dependent on the composition of the LC mobile phase to an astonishing degree. At concentration levels of a few hundred ng/l, laboratory experiments showed that the aromatic amines considered here were mostly associated to dissolved humic acids (HAs) by both reversible and irreversible bindings. The addition of a reducing agent, i.e., NaBH4, succeeded in liberating that fraction of aromatic amines, which being reversibly bound to quinoidal structures of HAs are bioavailable. Analyte recoveries were better than 85% on extraction from 4 l of drinking water (spike level, 25 ng/l), 2 l of ground water (spike level, 50 ng/l) and 0.5 l of river water (spike level, 200 ng/l). Relative standard deviations ranged between 4.6 and 20% for drinking water, 4.3 and 15% for ground water, 5.9 and 13% for river water. Method detection limits calculated for drinking water, groundwater and surface water were between 3 and 11, 6 and 21, 36 and 75 ng/l, respectively.  相似文献   

6.
A method has been developed for confirmation and quantitation of ten sulfonylurea herbicides (nicosufuron, thifensulfuron-methyl, metsulfuron-methyl, sulfometuron-methyl, chlorsulfuron, ethametsulfuron-methyl, tribenuron, bensulfuron-methyl, pyrazosulfuron-ethyl and chlorimuron-ethyl) in water samples. Herbicides were extracted from water by off-line solid-phase extraction (SPE). Different types of absorbents were evaluated: silica-based ODS-C18 and two polymeric sorbents, Cleanert HXN and Oasis HLB. Analyte determination and quantitation was performed by liquid chromatography with electrospray mass spectrometry (LC-ESI-MS) instrumentation, equipped with ion trap mass filter. Confirmatory analysis was carried out by LC/MS/MS. MS data acquisition was performed by a single or two-ion extracted ion monitoring program. The ten herbicides were measured in fortified tap water. Average recoveries of the nine analytes (except for tribenuron) from water samples were in the range of 77–109%, and the RSD ranged from 0.3 to 14.5%. The limit of detections (LODs) varied from 6 to 34.8 ng/L.  相似文献   

7.
A trace analytical procedure was developed to assay the anticancer drugs methotrexate, azathioprine, doxorubicin, doxorubicinol, vincristine, ifosfamide, cyclophosphamide, etoposide, and procarbazine in water samples from sewage treatment plants. After concentration and purification using Oasis HLB solid-phase extraction cartridges and Oasis WAX cartridges, the analytes were separated using ultra-high performance liquid chromatography coupled with the electrospray ionization tandem mass spectrometry operating in the positive ion mode. The method showed good precision and accuracy. Recoveries of all analytes were in the range of 45.3-108.9% with relative standard deviations between 2.4-24.5%. The limits of detection for influent and effluent sewage water were in the range of 0.6-7.0 ng/L and 0.5-3.5 ng/L, respectively. It is expected that this method will be applied to investigate the environmental occurrence of anticancer drugs in sewage water.  相似文献   

8.
To assess the potential risks associated with the environmental exposure of β-lactam antibiotics (BLAs), the monitoring of the occurrence, distribution, and fate of these emerging contaminants in the environment is required. Herein, we demonstrate a molecularly imprinted solid-phase extraction (MISPE) method for selective and reliable screening of trace BLAs in river and tap water. By developing a low-temperature photopolymerization, highly selective molecularly imprinted polymers (MIPs) for five BLAs (penicillin G, amoxicillin, ampicillin, nafcillin and mezlocillin) were synthesized. Nafcillin was chosen as a pseudo template to make the MIP sorbent (Nafc-MIP), which was used in pseudo-template MISPE for preconcentration of the other four BLAs from river and tap water. The application of pseudo-template MISPE overcomes the template bleeding, which significantly elevates the sample background and restricts the application of MIP for detection of the target BLA below 2 μg/L. The average recoveries of BLAs are in the range of 60–90% when Nafc-MIP was adopted as the selective MISPE sorbent. The developed method was validated, and applied to the screening of trace β-lactam antibiotics in river and tap water. The linearity of the calibration curve for each BLA was observed over the range of 0.1–20 μg/L (r > 0.998). The β-lactam antibiotics were found within the range of 0–9.56 μg/L in river water at the downstream of antibiotics manufacturers, and none were detected in the tap water.  相似文献   

9.
Capillary liquid chromatography (cLC) hyphenated with tandem mass spectrometry (MS-MS) was used to separate and quantitate trace concentrations of five estrogens in aqueous samples. New C(18)-based sorption materials bound to the silica support by monomeric and polymeric mechanisms were compared and tested for solid-phase extraction (SPE) of selected analytes with respect to optimization of their preconcentration yield. Application of an endcapped, monomer-bound preconcentration Discovery DSC-18Lt column under the optimized conditions provides yields in the range from 95 to 100% with a high repeatability (n=3, RSD≤7.2%). Using the electrospray ionization in the positive mode (ESI+), the cLC-MS-MS system (the Zorbax SB C18 capillary column and a binary mobile phase of acetonitrile and water containing 0.1% formic acid in both the components) was optimized to attain a sufficient retention of the early eluting estriol, a satisfactory resolution of the analytes and the maximum sensitivity of the determination. Both the isocratic and gradient elution were used and the optimized gradient method permitted analyses of aqueous environmental samples in 14 min within a linearity range from 6.1 to 25.0 (LOQ of analytes) to 500 ng/L and with a very good linearity (r>0.9981) for all the estrogens studied. The detection limits are in the range from 3.0 to 6.8 ng/L (1 μL injection volume). Six environmental water samples were analyzed and the studied estrogens were found in the Vltava river sample collected in Prague (13.2 ng/L for 17β-estradiol) and in the inlet to the wastewater treatment plant in Prague, at an overall concentration of 371.4 ng/L.  相似文献   

10.
A method for simultaneous determination of four benzodiazepines (bromazepam (BMZ), carbamazepine (CBZ), diazepam (DZP) and nordiazepam (NDZ)) and four barbiturates (barbital (BTL), pentobarbital (PTB), phenobarbital (PNB) and secobarbital (SCB)) in river water and wastewater using solid-phase extraction (SPE) followed by liquid chromatography-(electrospray) tandem mass spectrometry (LC-(ESI)MS/MS) was developed. LC-(ESI)MS/MS analysis was performed in positive and negative modes for benzodiazepines and barbiturates, respectively, and in selected reaction monitoring (SRM). Limits of detection (LODs) were in the range of 0.2–5 ng/L for benzodiazepines and 2.5–50 ng/L for barbiturates. Precision (repeatability and reproducibility between days) expressed as %RSD (n = 5) was lower than 17% for low concentration (depending on the matrix between 50 and 250 ng/L for barbiturates, and between 5 and 25 ng/L for benzodiazepines), and lower than 15% for high concentration (between 200 and 1250 ng/L for barbiturates, and between 20 and 125 ng/L for benzodiazepines). Low matrix effect was observed for all compounds, except for BTL (75%) and PTB (–48%) in wastewater. The method was applied to water samples from two sewage treatment plants (STPs) and the rivers Ebre, Ter and Llobregat, located in Catalonia. CBZ was the target compound found at the highest concentration in river water (2.1–3.3 ng/L). In both influent and effluent wastewater samples, PNB, BMZ, CBZ, DZP and NDZ were determined at concentration levels ranging from 5.0 to 2337.3 ng/L.  相似文献   

11.
邱盼子  郭欣妍  王娜  孔祥吉  何华 《色谱》2015,33(7):722-729
建立了一种同时测定制药废水中3类10种抗生素的超高效液相色谱-串联质谱分析方法。水样用固相萃取柱富集净化,通过比较在不同的固相萃取柱和洗脱液等条件下水样中目标物的回收率,优化了前处理方法。采用Agilent C18色谱柱(75 mm×2.1 mm, 2.7 μm),以0.2%(v/v)甲酸水溶液和乙腈为梯度洗脱的流动相,在电喷雾-多反应监测模式下进行定性定量分析。实验结果表明:在0.1~1000 μg/L范围内,6种氨基糖苷类抗生素、螺旋霉素及3种氟喹诺酮类抗生素的峰面积与质量浓度的线性关系良好(r2 > 0.995),方法检出限为0.07~4.37 ng/L,定量限为0.22~14.55 ng/L;目标抗生素的加标水平为0.002~40 μg/L时,平均回收率为50.4%~114.1%,相对标准偏差均不高于9.89%(n=3)。基于上述方法,对江苏省某制药厂废水中相关物质进行检测,在各废水处理单元中检出3种目标抗生素,质量浓度范围为0.46~1033.60 μg/L。该方法准确可靠、灵敏度高,适用于制药厂废水中氨基糖苷类抗生素、螺旋霉素和氟喹诺酮类抗生素的检测。  相似文献   

12.
A simple and rapid method for the determination of eleven phenols in water samples is presented. The target analytes are isolated by stir membrane liquid-liquid microextraction working under the three-phase mode. An alkaline aqueous solution is used as extractant phase while octanol is selected as supported liquid membrane solvent. The target analytes are separated and determined by liquid chromatography (LC) with ultraviolet detection (UV). All the variables involved in the extraction process have been studied in depth. Low detection limits (in the range from 82.1 ng/L for phenol to 452 ng/L for 2,4,5-trichlorophenol) were obtained. The repeatability, expressed as relative standard deviation (RSD), varied between 1.3% (for 4-nitrophenol) and 8.0% (for 4-chlorophenol). The enrichment factors were in the range from 168 (for 2,4,5-trichlorophenol) to 395 (for 3-chlorophenol). The proposed procedure was applied for the direct determination of the eleven phenols in some real water samples including river, well and tap waters. The accuracy was evaluated by means of a recovery study, the results being in the range of 87-120%.  相似文献   

13.
There is increasing interest and demand for real multi-residue methods able to simultaneously determine pesticides with a broad spectrum of chemical characteristics in environmental and biological matrices. A method based on solid-phase extraction with a Carbograph 4 cartridge and liquid chromatography with electrospray mass spectrometry (LC-ES-MS) enabling simultaneous determination of non-acidic and acidic pesticides in real water samples is described. On repeatedly (n=5) extracting 4 l of drinking water (spike level 50 ng/l), 2 l of ground water (spike level 100 ng/l) and 1 l of river water (spike level 200 ng/l), recovery of 26 base/neutral pesticides and 13 acidic pesticides were equal to or better than 80%, except for carbendazim (67%), butocarboxim (73%), aldicarb (75%) and molinate (77%). Relative standard deviations ranged between 4 and 15%. Final extracts containing acidic and non-acidic pesticides were analyzed in a single chromatographic run while the ES-MS system was operated in both positive and negative ion modes. With the aim of finding the best operating conditions, in terms of sensitivity, the pH of the LC eluent was varied in the 2.9-8.4 range. Altogether, the best results were obtained by using an LC eluent containing 1 mmol/l formic acid. Over the entire pH range considered, well shaped peaks for both basic and acidic analytes were achieved by the use of a new generation LC column. By extracting selected ion current profiles from the total ion current mass chromatogram relative to analysis of 4 l of drinking water spiked with 50 ng/l of each of the 39 analytes, estimated limits of detection ranged between 0.05 and 1.5 ng/l, except for propyzamide (8 ng/l) and 2,4-DB (3 ng/l).  相似文献   

14.
近年来,双酚A、四溴双酚A及烷基酚类化合物由于其对水生生物的内分泌干扰作用受到越来越广泛的关注。污水处理厂是处理这类化合物的重要途径,研究目标物在其中的浓度分布对于探明此类物质在环境中的暴露水平具有重要意义,而建立相应的分析测定方法则是开展上述研究的基础。本研究建立了同时测定污水处理厂水样中双酚A、四溴双酚A及6种烷基酚类化合物的反相液相色谱-电喷雾串联质谱分析方法。结果发现,以ZORBAX Eclipse Plus C18色谱柱(150 mm×2.1 mm,3.5 μm)为分离柱,乙腈和0.02%(v/v)氨水溶液为梯度洗脱的流动相,电喷雾质谱负离子模式下目标化合物在11 min内分离;在1~100 μg/L范围内,双酚A、四溴双酚A及6种烷基酚类化合物的峰面积与质量浓度的线性关系良好(R2≥0.998),方法定量限为2.0~20 ng/L;添加水平分别为0.2、2、20 μg/L时,目标化合物的平均回收率分别为64.3%~118.0%、65.9%~100.5%、70.3%~102.7%,相对标准偏差均小于7.1%。基于上述方法,对江苏省某工业园区污水处理厂水样中相关物质进行检测,出水中检出5种目标化合物,质量浓度范围为11.9~3015.3 ng/L。结果表明,该方法准确可靠、灵敏度高,适用于污水处理厂水样中相关烷基酚类化合物的检测。  相似文献   

15.
A sensitive and reliable method using liquid chromatography-electrospray tandem mass spectrometry has been developed and validated for the trace determination of beta-lactam antibiotics in natural and wastewater matrices. Water samples were enriched by solid-phase extraction. The analytes included amoxicillin (AMOX), ampicillin (AMP), oxacillin (OXA), cloxacillin (CLOX) and cephapirin (CEP). Average recoveries of beta-lactams (BLs) in fortified samples were generally above 75% (except amoxicillin) with the standard deviations lower than 10% in water matrices. Amoxicillin was not quantified due to poor recovery (less than 40%) in the investigated water matrices. Matrix effects were found to be minimal when measuring these compounds in water matrices. The accuracy, within- and between-run precision of the assay fell within acceptable ranges of 15% absolute. The method detection limit (MDL) was estimated to range between 8 and 10 ng/L in surface water, 13 and 18 ng/L in the influent and 8 and 15 ng/L in the effluent from a wastewater treatment plant. A large number of actual water samples were analyzed using this method in order to evaluate the occurrence of the beta-lactams in a river and a wastewater treatment plant in northern Colorado. Most of the samples were negative for all analytes. These compounds were found at 15-17 ng/L in the three influent samples and at 9-11 ng/L in three surface water samples out of a total of 200 samples. This indicates that contamination by beta-lactam antibiotics is of minor importance to the small mixed-watershed.  相似文献   

16.
A method for the quantitative determination of seven major antidepressants in surface waters and sewage treatment plant effluents by CE using ESI-MS is presented. Calibration curves for the selected analytes were prepared in Milli-Q purified water and Danube river water extract covering a concentration range of at least one order of magnitude. LODs achieved were between 6 and 13 microg/L for Trazodone and 39 and 53 microg/L for Sertraline in the Milli-Q purified water and Danube river water matrix, respectively. For sample preparation eight different SPE materials were investigated. Best results were obtained for a resin based on hydrophilic divinylbenzene (recoveries from Milli-Q purified water 93-96%; from Danube river water 85-99%). Finally, a series of eight sewage treatment plant effluents were investigated with respect to their content in the selected antidepressants. Six of these samples were tested positive for antidepressants, in particular Venlafaxine, Citalopram and Trazodone in concentrations between 36 and 322 ng/L.  相似文献   

17.
An automated at-line SPE–GC–MS system for the determination of micropollutants in aqueous samples, which is based on the PrepStation and uses large-volume on-column injections, has been redesigned. A cartridge made from stainless steel and polychlorotrifluoroethylene and a 2-needle system was constructed which allow the determination of micropollutants at the low ng/L level without interferences from impurities extracted from the septa of the vials or the commercial cartridges. No time-consuming pre-cleaning of the cartridges or septa is required. The SPE sample extract (300 μL) is transferred from the sample preparation module to the autosampler of the GC–MS and 50 or 100 μL are injected. The analytical characteristics of the integrated procedure such as analyte recovery (typically 80–105%) and repeatability (RSDs, 2–9%), were satisfactory. Several micropollutants were detected in (unfiltered) river water at the 0.2–400 ng/L level using full-scan MS acquisition. The system proved to be robust during the analysis of more than 100 tap and river water samples.  相似文献   

18.
A trace analytical method based on high performance liquid chromatography coupled to quadrupole time-of-flight high resolution mass spectrometry was developed for simultaneous determination of perfluoroalkyl phosphonates (PFPAs, carbon chain lengths C6,8,10), perfluoroalkyl carboxylates (PFCAs, C5-12), and perfluoroalkyl sulfonates (PFSAs, C4,6,8,10) in drinking water (tap water). Analytes were enriched on a mixed mode co-polymeric sorbent (C8+quaternary amine) using solid phase extraction. Chromatographic separation was achieved on a Zorbax Extend C18 reversed phase column using a mobile phase gradient consisting of water, methanol, and acetonitrile containing 2mM ammonium acetate and 5 mM 1-methyl piperidine. The mass spectrometer was operated in electrospray negative ion mode. Use of 1-methyl piperidine in the mobile phase resulted in a significant increase in instrument sensitivity for PFPAs through improved chromatographic resolution, background suppression, and increased ionization efficiency. Method detection limits for extraction of 500 mL tap water were in the ranges of 0.095-0.17 ng/L, 0.027-0.17 ng/L, and 0.014-0.052 ng/L for PFPAs, PFCAs, and PFSAs, respectively. Whole method recoveries at a spiking level of 0.5 ng/L to 500 mL HPLC grade water were 40-56%, 56-97%, and 55-77% for PFPAs, PFCAs, and PFSAs, respectively. A matrix effect (signal enhancement) was observed in the detection of PFPAs in tap water extracts, leading to calculated recoveries of 249-297% at a 0.5 ng/L spiking level. This effect resulted in an additional improvement of method sensitivity for PFPAs. To compensate for the matrix effect, PFPAs in tap water were quantified using matrix-matched and extracted calibration standards. The method was successfully applied to the analysis of drinking water collected from six European countries. PFPAs were not detected except for perfluorooctyl phosphonate (PFOPA) at close to the detection limit of 0.095 ng/L in two water samples from Amsterdam, the Netherlands. Highest levels were found for perfluorobutane sulfonate (PFBS, 18.8 ng/L) and perfluorooctanoate (PFOA, 8.6 ng/L) in samples from Amsterdam as well as for perfluorooctane sulfonate (PFOS, 8.8 ng/L) in tap water from Stockholm, Sweden.  相似文献   

19.
Takino M  Daishima S  Nakahara T 《The Analyst》2001,126(5):602-608
A method for the determination of six chlorinated phenoxy acid herbicides in river water was developed using in-tube solid-phase microextraction (SPME) followed by liquid chromatography/electrospray ionization-mass spectrometry (LC/ESI-MS). In-tube SPME is an extraction technique for organic compounds in aqueous samples, in which analytes are extracted from a sample directly into an open tubular capillary by repeated draw/eject cycles of the sample solution. Simple mass spectra with strong signals corresponding to [M-H]- and [M-RCOOH]- were observed for all herbicides tested in this study. The best separation of these compounds was obtained with a C18 column using linear gradient elution with a mobile phase of acetonitrile-water containing 5 mmol l-1 dibutylamine acetate (DBA). To optimize the extraction of herbicides, several in-tube SPME parameters were examined. The optimum extraction conditions were 25 draw/eject cycles of 30 microliters of sample in 0.2% formic acid (pH 2) at a flow rate of 200 microliters min-1 using a DB-WAX capillary. The herbicides extracted by the capillary were easily desorbed by 10 microliters acetonitrile. Using in-tube SPME-LC/ESI-MS with time-scheduled selected ion monitoring, the calibration curves of herbicides were linear in the range 0.05-50 ng ml-1 with correlation coefficients above 0.999. This method was successfully applied to the analysis of river water samples without interference peaks. The limit of quantification was in the range 0.02-0.06 ng ml-1 and the limit of detection (S/N = 3) was in the range 0.005-0.03 ng ml-1. The repeatability and reproducibility were in the range 2.5-4.1% and 6.2-9.1%, respectively.  相似文献   

20.
In recent years, an increasing concern has risen about the presence of pharmaceuticals in the aquatic environment. Despite their toxicity, increasing consumption and release into the municipal sewage, only a few studies have been focused on cytostatic drugs, mainly due to the lack of methods for their simultaneous analysis. In this work, a method, based on solid-phase extraction prior to high-performance liquid chromatography-triple quadrupole mass spectrometry determination, was optimized and validated for the simultaneous determination of some (14) of the most widely used cytostatic drugs in river water, influent and effluent wastewater. Process efficiency was in the range between 41 and 99% in real samples, except for cytarabine (24%), docetaxel (17%) and methotrexate (30%), due to suppression effects; precision values were <11%, except for gemcitabine (up to 19%); and detection limits were in the range between 0.1 and 38 ng/L. Cytarabine, doxorubicin, etoposide, gemcitabine, iphosphamide and vinorelbine were found at concentration levels up to 14 ng/L in influent and effluent wastewater, showing an insignificant decrease during sewage treatment; cytarabine and gemcitabine were found in effluent wastewater and were also detected in river water associated with effluent discharges.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号