首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A sensitive and convenient method for the determination of trace europium ions using an oscillating chemical reaction involving Ce(IV) - KBrO3 - acetone - oxalic acid - H2SO4 was proposed. The results indicated that the changes in oscillating period (T) was linearly proportional to the negative logarithmic concentration of Eu3+ (-log C) in the range of 1.41 × 10−8 ˜ 1.41 × 10−4 mol L−1 (r = 0.9982) with a detection limit of 1.04 × 10−9 mol L−1. The recoveries were limited to the range of 99.5% to 100.8%. Under the same conditions, other rare earth ions did not interfere with the determination of Eu3+. In addition, a perturbation mechanism was also discussed briefly.   相似文献   

2.
A convenient and sensitive method for determination of sulfanilamide (SNA) was described based on the Mn(II)-catalyzed oscillating chemical reaction. Under optimum conditions, a linear relationship existed between the changes of oscillating period or amplitude and the negative of logarithm of SNA concentration in the range of 4.27 × 10−8 mol ·L−1 ∼ 7.41 × 10−6 mol ·L−1 (RSD, 0.85%) and 9.33 × 10−8 mol ·L−1 ∼ 3.02 × 10−6 mol ·L1 (RSD, 1.08%), respectively. The lower limit of detection was found to be 2.69 × 10−8 mol ·L−1 and 6.03 × 10−8 mol ·L−1, respectively.   相似文献   

3.
A new all plastic sensor for Co2+ ions based on 2-amino-5 (hydroxynaphtyloazo-1′)-1,3,4 thiadiazole (ATIDAN) as ionophore was prepared. The electrode exhibits a low detection limit of 1.5 × 10−6 mol L−1 and almost theoretical Nernstian slope in the activity range 4.0 × 10−6–1 × 10−1 mol L−1 of cobalt ions. The response time of the sensor is less than 10 s and it can be used over a period of 6 months without any measurable divergence in potential. The proposed sensor shows a fairly good selectivity for Co(II) over other metal ions. The electrode was successfully applied for determination of Co2+ in real samples and as an indicator electrode in potentiometric titration of Co2+ ions with EDTA.   相似文献   

4.
The potentiometric response characteristics of a diclofenac selective electrode, based on ion association in different plasticizers, were compared. The sensitivity, working range, detection limit and selectivity of membrane sensors demonstrated significant dependence on the type of plasticizers. The potentiometric unit presented a linear response toward diclofenac concentrations between 1 × 10−5 − 5 × 10−2 mol L−1, with slopes of approximately 60 mV dec−1, and exhibited a response time of 3 s. The potentiometric analysis of sodium diclofenac in pharmaceutical formulations was perfomed by the membrane electrode proposed and compared with the results of potentiometric titration given by the Pharmacopoeia of Ukraine.   相似文献   

5.
Naproxen membrane electrodes based on different plasticizers and the quaternary ammonium salts (QASs) dimethyldidecylammonium bromide, methyltrioctylammonium chloride, or tetraoctylammonium chloride, were prepared. The following basic parameters were investigated for the optimal electrode: measurement range (10−4 − 10−1 mol L−1), slope of the linear range of the calibration curve (−58.3 mV decade−1), limit of detection (6.0 × 10−5 mol L−1), lifetime (2.5 months), dependence of the electrode potential on pH (5.5 − 9.0), reproducibility of potential (1.2 mV) and selectivity coefficients in relation to selected organic and inorganic anions. The electrode was utilized for determination of naproxen in tablets by the calibration curve method and the standard addition method.   相似文献   

6.
A kinetic spectrophotometric method for hydrazine determination in the range of 9.36×10−7 to 4.37×10−5 mol dm−3, based on the inhibitory effect of hydrazine on the oxidation of Victoria Blue 4- R by KBrO3, was developed and validated. Kinetic parameters are reported for both the indicating and the inhibiting reaction. The detection limit was established as 9.98×10−8 mol dm−3. The selectivity of the proposed method was tested considering the influence of different ions that may be present in real samples. The method was successfully applied for hydrazine determination in various samples (very pure water from the water-steam system of a power plant and Isoniazid tablets, a pharmaceutical product).   相似文献   

7.
Ibuprofen membrane electrodes based on different plasticizers: diisobutyl phthalate (DIBP), o-nitrophenyloctyl ether (o-NPOE), dioctyl sebacate (DOS) and tetraoctylammonium 2-(4-isobutylphenyl)propionate were prepared. All electrodes show: a near Nernstian slope of characteristic (58.3–60.9 mV decade−1) in the measurement range (10−4–10−1 mol L−1), limit of detection (5.0×10−5 mol L−1), really long lifetime (12 months), dependence of the electrode potential on pH (5.5–9.0), reproducibility of potential (0.6–1.2 mV) and selectivity coefficients in relation to some organic and inorganic anions. The electrodes were applied for the determination of ibuprofen in tablets by the calibration curve method and the standard addition method.   相似文献   

8.
Electrochemical oxidation of methylthiomethyleneisoquinolinium chloride (MTMIQ), the first alkylthiomethyl substituted ammonium salt, which is fully miscible with water has been investigated by voltammetric (SWV) method using glassy carbon electrode. On the electrode, MTMIQ undergoes oxidation at the potential near Ep = 0.07V (vs. Ag/AgCl/3 M KCl). The influence of the pH of buffers, amplitude, frequency, step potential on the received signal was studied. The best results were obtained with a citrate buffer at a pH of 5. The oxidation peak current used for MTMIQ voltammetric determination was in the range of 2–8×10−5 mol L−1, LOD = 3.7×10−6, LOQ = 1.2×10−5. The product of the oxidation was accumulated at the working electrode and was investigated by spectroscopic method. Mechanistic pathways of the oxidation have been proposed.   相似文献   

9.
The optimal process of pre-treatment and activation of gold rotating disc electrode (AuRDE) before voltammetric determination of mercury is proposed. This treatment encompasses polishing of the electrode surface, electrochemical cycling, and activation. This procedure both increases determination sensitivity as well as improves determination reproducibility. The detection limit on the working electrode achieved using this approach amounted to 8.26·10−10 mol L−1for direct mercury determination in water solution (applying 200 s running accumulation). The procedure of the quantitative mercury isolation from complicated sample matrix was developed as well. It provides better selectivity and significant increase of sensitivity of mercury determination. In case of mercury isolation from one liter of water the detection limit is 6.23·10−11 mol L−1 (analyzing a greater sample volume the determined concentration could be lower).   相似文献   

10.
A new amperometric titration method was developed for quantitative determination of ferrate(VI) (FeVIO4 2−) in the 7.06×10−5−5.73×10−3 M concentration range. Chromium(III) hydroxide solution was used as the titrant. The diffusion current (Id) had a linear relationship with the concentration of ferrate(VI) and slopes were dependent on the concentration of NaOH. The amperometric titration could detect a lower concentration of ferrate(VI) than could potentiometric and colorimetric titrations. The method was applied successfully to determine concentrations of ferrate(VI), generated electrochemically, in strong alkaline solutions.   相似文献   

11.
In this study the application of home-made unmodified (GC) and bulk modified boron doped glassy carbon (GCB) electrodes for the voltammetric determination of the linuron was investigated. The electrodes were synthesized with a moderate temperature treatment (1000°C). Obtained results were compared with the electrochemical determination of the linuron using a commercial glassy carbon electrode (GC-Metrohm). The peak potential (E p ) of linuron oxidation in 0.1 mol dm−3 H2SO4 as electrolyte was similar for all applied electrodes: 1.31, 1.34 and 1.28 V for GCB, GC and GC-Metrohm electrodes, respectively. Potential of linuron oxidation and current density depend on the pH of supporting electrolyte. Applying GCB and GC-Metrohm electrodes the most intensive electrochemical response for linuron was obtained in strongly acidic solution (0.1 mol dm−3 H2SO4). Applying the boron doped glassy carbon electrode the broadest linear range (0.005–0.1 μmol cm−3) for the linuron determination was obtained. The results of voltammetric determination of the linuron in spiked water samples showed good correlation between added and found amounts of linuron and also are in good agreement with the results obtained by HPLC-UV method. This appears to be the first application of a boron doped glassy carbon electrode for voltammetric determination of the environmental important compounds.   相似文献   

12.
Three simple protocols for the extraction of acyclovir from its pharmaceutical creams based on ultrasonication, ultrasonication with heating and magnetic stirring were evaluated and compared. Extraction kinetics were studied at different time intervals (5, 10, 15, 30 and 60 min) and the extraction efficiency was determined by HPLC. The effect of concentration of aqueous NaOH as the extraction medium and the stirring speed were also studied and optimized. Best results were obtained with 50 mL of 0.01 mol L−1 aqueous NaOH with magnetic stirring speed of 500 r.p.m. HPLC analysis involved rapid separation of acyclovir from the cream matrix using a 100 × 4.6 mm i.d. monolithic column and UV detection at 254 nm. Magnetic stirring produced the best results in terms of extraction efficiency with an average extraction yield of 100.8%, n = 16 at an optimum extraction time of 15 min. The selected protocol was validated for within and day-to-day precision and ruggedness.   相似文献   

13.
The goal was to electrospin 2-hydroxyethyl methacrylate — based biocompatible polymers and prepare submicron fibres (nanofibers) for biomedicinal applications. Syntheses of poly(2-hydroxyethyl methacrylate) (HEMA) and its copolymer with 2-ethoxyethyl methacrylate (EOEMA), and their characterization by viscometry and molecular weight are described. Their relation to electrospinning is discussed. Electrospinning of HEMA homopolymer from water-ethanol is successful for molecular weights 6.31 × 105 and 1.80 × 106 g/mol. Electrospinning of HEMA/EOEMA copolymers is feasible from ethanol.   相似文献   

14.
In this paper, a highly selective molecularly imprinted polymer (MIP) for tramadol hydrochloride, a drug used to treat moderate to severe pain, was prepared and its use as solid-phase extraction (SPE) sorbent was demonstrated. The molecularly imprinted solid-phase extraction procedure followed by high performance liquid chromatography with ultraviolet detector (MISPE-HPLC) was developed for selective extraction and determination of tramadol in human plasma and urine. The optimal conditions for molecularly imprinted solid-phase extraction (MISPE) consisted of conditioning with 1 mL methanol and 1 mL of deionized water at neutral pH, loading of tramadol sample (50 μg L−1) at pH 7.5, washing using 1 mL acetone and elution with 3 × 1 mL of 10% (v/v) acetic acid in methanol. The MIP selectivity was evaluated by checking several substances with similar molecular structures to that of tramadol. Results from the HPLC analyses showed that the calibration curve of tramadol (using MIP from human plasma and urine) is linear in the ranges of 6–100 and 3–120 μg L−1 with good precisions (1.9% and 2.9% for 5.0 μg L−1), respectively. The recoveries for plasma and urine samples were higher than 81%.   相似文献   

15.
A simple and sensitive dispersive liquid-liquid microextraction method for extraction and preconcentration of pentachlorophenol (PCP) in water samples is presented. After adjusting the sample pH to 3, extraction was performed in the presence of 1% W/V sodium chloride by injecting 1 mL acetone as disperser solvent containing 15 μL tetrachloroethylene as extraction solvent. The proposed DLLME method was followed by HPLC-DAD for determination of PCP. It has good linearity (0.994) with wide linear dynamic range (0.1–1000 μg L−1) and low detection limit (0.03 μg L−1), which makes it suitable for determination of PCP in water samples.   相似文献   

16.
A new and convenient method for the determination of Alizarin Red S by the perturbations caused by different amounts of Alizarin Red S on a novel B-Z oscillating system is proposed. This new type Belousov-Zhabotinskii involves a macrocyclic copper(II) complex [CuL](ClO4)2 as catalyst and malic acid as the substrate. The ligand L in the complex is 5,7,7,12,14,14-hexamethyl-1,4,8,11-tetraazacyclotetradeca-4,11-diene. It is found that the relationship between the change in the oscillation amplitude and the logarithm of the Alizarin Red S concentration in the range of 1.5 × 10−7 to 1 × 10−3 M fits a polynomial model: ΔA = 659 + 184.2 log [Alizarin Red S]+ 12.9 log2 [Alizarin Red S]. The RSD obtained with ten samples is 4.4%. The probable mechanism involving the perturbation of Alizarin Red S on the oscillating chemical system is also discussed.   相似文献   

17.
The influence of EDTA, carboxylic acids, amino-and hydroxocarboxylic acids, monosaccharides and humic substances on the generation of arsines in hydride generation atomic absorption spectrometry (HGAAS) was investigated. EDTA (0.02 mol L−1), ascorbic acid (0.02 mol L−1) and glucose or fructose (0.2 mol L−1) are useful additives for levelling sensitivities for As(III), monomethylarsonate (MMA) and dimethylarsinate (DMA). The presence of glycine, malonic, tartaric acids, BICIN and soil humin extracts leads to differences in analytical signal response between these arsenic species. An analytical application to the determination of the sum of As(III), monomethylarsonate (MMA) and dimethylarsinate (DMA) as well as the sum of toxicologically relevant hydride forming arsenic fraction As(III) + As(V) + MMA + DMA in EDTA soil/sediment extracts using continuous flow HGAAS was demonstrated. The limit of detection was 0.2 mg kg−1 As. Within-day and between-day precision were in the range 3–7% and 4–10%, respectively, for arsenic contents of 0.7–25 mg kg−1, with recoveries 95–103%.   相似文献   

18.
This work presents a nano-Al2O3 solid phase extraction technique for the determination of ultra-trace amounts of inorganic selenium species in aqueous systems using ion chromatography inductively coupled plasma-mass spectrometry (IC-ICP-MS). In this experiment, the inorganic selenium species were successfully extracted on a nano-Al2O3 solid phase column and then quantitative eluted with a 100 mmol L−1 NaOH solution. Extraction conditions such as solvent identity, solvent concentration, solvent volume, solvent pH and salt addition were optimized. Under the optimum extraction conditions (elute solvent: 100 mmol L−1 NaOH, solvent volume: 4 mL, pH: 7.0), low detection limits (Se (IV): 6 ng L−1, Se (VI): 11 ng L−1; RSD<5.0%) and good linear range (0.5–100 ng mL−1, R2 > 0.999) were obtained for all of the analytes. Good spiked recoveries over the range of 80–98% were obtained by applying the proposed method on real environmental water samples. These results indicated that this method is very sensitive and reliable when monitoring trace levels of inorganic selenium species in aqueous samples.   相似文献   

19.
The kinetics of base hydrolysis of glycine, histidine, and methionine methyl esters in the presence of [Pd(pip)(H2O)2]2+ complex, where pip is piperazine, is studied in aqueous solutions, at T = 25°C, and I = 0.1 mol dm−3. The rate of ester hydrolysis for glycine methyl ester is studied at different temperature and dioxane/water solutions of different compositions. The kinetic data are fit under the assumption that the hydrolysis proceeds in one step. The activation parameters for the base hydrolysis of the complexes are evaluated   相似文献   

20.
A solid phase extraction technique for the determination of platinum(IV) at trace levels by inductively coupled plasma mass spectromA solid phase extraction technique for the determination of platinum(IV) at trace levels by inductively coupled plasma mass spectrometry (ICP-MS) was developed. The method was based on retention of platinum in a sample on silica gel modified with aminepropyl groups. The retention of platinum(IV) from the sample solution and the recovery of platinum with 1.0 mol L−1 thiourea solution were quantitative. The relative standard deviation (RSD) was calculated as 5% (n = 7) at the 10 ng L−1 level. The enrichment factor was found to be (50-fold) for 250 mL of water sample. Under optimum conditions, the method detection limit (MDL) was found to be 1 ng L−1 for platinum in water matrices. Recoveries of Pt from spike addition to atmospheric water samples were quantitative (80–95%). The present method was used for the determination of platinum in precipitation, throughfall and runoff water samples.   相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号