首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
An in-situ antimony film screen-printed carbon electrode (in-situ SbSPCE) was successfully used for the determination of Cu(II) simultaneously with Cd(II) and Pb(II) ions, by means of differential pulse anodic stripping voltammetry (DPASV), in a certified reference groundwater sample with a very high reproducibility and good trueness. This electrode is proposed as a valuable alternative to in-situ bismuth film electrodes, since no competition between the electrodeposited copper and antimony for surface sites was noticed. In-situ SbSPCE was microscopically characterized and experimental parameters such as deposition potential, accumulation time and pH were optimized. The best voltammetric response for the simultaneous determination of Cd(II), Pb(II) and Cu(II) ions was achieved when deposition potential was −1.2 V, accumulation time 120 s and pH 4.5. The detection and quantification limits at levels of μg L−1 suggest that the in-situ SbSPCE could be fully suitable for the determination of Cd(II), Pb(II) and Cu(II) ions in natural samples.  相似文献   

2.
Polyimide (PI) sheets were laser etched to obtain graphene-based carbon nanomaterials (LEGCNs). These were analyzed by scanning electron microscopy, X-ray diffraction and Raman spectroscopy which confirmed the presence of stacked multilayer graphene nanosheets. Their large specific surface and large number of edge-plane active sites facilitate the accumulation of metal ions. A glassy carbon electrode (GCE) with an in-situ plated bismuth film was modified with the LEGCNs to give a sensor with satisfactory response for the simultaneous determination of cadmium(II) and lead(II) by means of square wave anodic stripping voltammetry. It appears that is the first report on an electrochemical sensor based on the use of laser etched graphene for determination of heavy metal ions. Figures of merit for detection of Cd(II) include (a) a low and well separated working potential of ?0.80 V (vs. Ag/AgCl), (b) a wide linear range (from 7 to 120 μg·L?1), and a low detection limits 0.47 μg·L?1. The respective data for Pb(II) are (a) -0.55 V, (b) 5 to 120 μg·L?1, and (c) 0.41 μg·L?1. The modified GCE displays remarkable repeatability, reproducibility, selectivity and stability. The sensor was applied to the simultaneous determination of Cd(II) and Pb(II) in spiked real water samples. The results confirm that the laser etching technique is an efficient tool for the preparation of carbon nanomaterials with high quality and great sensing performance.
Graphical abstract Bismuth film and laser etched graphene-modified glassy carbon electrode (BF-LEGCN/GCE) for the simultaneous determination of cadmium(II) and lead(II) by square wave anodic stripping voltammetry.
  相似文献   

3.
This study presents a method for the selective determination of Hg(II) using electromembrane extraction (EME), followed by square wave anodic stripping voltammetry (SWASV), using a gold nanoparticle-modified glassy carbon electrode, (AuNP/GCE). By applying an electrical potential of typically 60 V for 12 min through a thin supported liquid membrane (1-octanol), Hg(II) ions are extracted from a donor phase (i.e., the sample solution) to an acidic acceptor solution (15 μL) placed in the lumen of a hollow fiber. The influences of experimental parameters during EME were optimized using face-centered central composite design. The calibration plot, established at a working voltage of 0.55 V (vs. Ag/AgCl), extends from 0.2 to 10 μg.L?1 of Hg(II). The limit of detection, at a signal to noise ratio of 3, is 0.01 μg.L?1 and the relative standard deviations (for 5 replicate determinations at 3 concentration levels) are between 7.5 and 8.7 %. The method was successfully applied to the determination of Hg(II) in spiked real water samples to give recoveries ranging from 89 to 97 %. The results were validated by cold vapor atomic absorption spectroscopy.
Graphical abstract Hg(II) ions were extracted from a donor phase into an acidic acceptor phase (15 μL) placed in the lumen of a hollow fiber using electromembrane extraction. The acceptor phase was then analyzed using anodic stripping voltammetry.
  相似文献   

4.
A molecularly imprinted polymer (MIP) and a nanocomposite prepared from gold nanoparticles (AuNP) and poly(3,4-ethylenedioxythiophene)/poly(styrene sulfonate) (PEDOT:PSS) were deposited on a screen-printed carbon electrode (SPCE). The nanocomposite was prepared by one-pot simultaneous in-situ formation of AuNPs and PEDOT:PSS and was then inkjet-coated onto the SPCE. The MIP film was subsequently placed on the modified SPCE by co-electrodeposition of o-phenylenediamine and resorcinol in the presence of the antibiotic nitrofurantoin (NFT). Using differential pulse voltammetry (DPV), response at the potential of ~ 0.1 V (vs. Ag/AgCl) is linear in 1 nM to 1000 nM NFT concentration range, with a remarkably low detection limit (at S/N?=?3) of 0.1 nM. This is two orders of magnitude lower than that of the control MIP sensor without the nanocomposite interlayer, thus showing the beneficial effect of AuNP-PEDOT:PSS. The electrode is highly reproducible (relative standard deviation 3.1% for n?=?6) and selective over structurally related molecules. It can be re-used for at least ten times and was found to be stable for at least 45 days. It was successfully applied to the determination of NFT in (spiked) feed matrices and gave good recoveries.
Graphical abstract Schematic representation of a voltammetric sensor for the determination of nitrofurantoin. The sensor is based on a screen-printed carbon electrode (SPCE) modified with an inkjet-printed gold nanoparticles-poly(3,4-ethylenedioxythiophene):poly(styrene sulfonate) nanocomposite and a molecularly imprinted polymer.
  相似文献   

5.
A simple procedure for the chemical synthesis of bismuth nanoparticles and subsequent adsorption on commercial screen-printed carbon electrodes offer reliable quantitation of trace zinc, cadmium and lead by anodic stripping square-wave voltammetry in nondeareated water samples. The influence of two hydrodynamic configurations (convective cell and flow cell) and the effect of various experimental variables upon the stripping signals at the bismuth-coated sensor are explored. The square-wave peak current signal is linear over the low ng mL−1 range (120 s deposition), with detections limits ranging from 0.9 to 4.9 ng mL−1 and good precision. Applicability to waste water certified reference material and drinking water samples is demonstrated. The attractive behaviour of the new disposable Bi nanoparticles modified carbon strip electrodes, coupled with the negligible toxicity of bismuth, hold great promise for decentralized heavy metal testing in environmental and industrial effluents waters.  相似文献   

6.
A glassy carbon electrode (GCE) modified with internal-electrolysis deposited gold nanoparticles (AuNPsied) was applied to sensitively and selectively detect As(III) by anodic stripping linear sweep voltammetry (ASLSV). The AuNPsied/GCE was prepared based on the redox replacement reaction between a supporting-electrolyte-free aqueous HAuCl4 and a copper sheet in saturated KCl separated by a salt bridge. Under optimum conditions (0.5 M aqueous H2SO4, 300-s preconcentration at − 0.4 V), the ASLSV peak current for the As(0)–As(III) oxidation responded linearly to As(III) concentration from 0.02 to 3 μM with a limit of detection (LOD) of 0.9 nM (0.07 μg L 1) (S/N = 3), while that for the As(III)–As(V) oxidation was linear with As(III) concentration from 0.02 to 1 μM with a LOD of 4 nM (0.3 μg L 1) (S/N = 3). An appropriate high-scan-rate for ASLSV can enhance both the sensitivity and signal-to-noise ratio. This method was applied for analyses of As(III) in real water samples.  相似文献   

7.
Yang HY  Chen WY  Sun IW 《Talanta》1999,50(5):977-984
A Tosflex-mercury film electrode (TMFE) was prepared by spin-coating a solution of the perfluorinated anion exchange polymer Tosflex onto a glassy carbon electrode surface followed by electrodeposition of mercury film on this electrode. This electrode was used for the determination of trace bismuth(III) which was preconcentrated onto the TMFE as anionic bismuth(III) complexes with chloride in a chloride medium. The preconcentration was carried out at a potential of-0.2 V, and the preconcentration of the bismuth(III) was enhanced significantly by the anion-exchange feature of Tosflex. The accumulated bismuth(III) was then determined by anodic square-wave stripping voltammetry (SWSV). Various parameters influencing the determination of bismuth(III) were examined in detail. With 2 min accumulation, the analytical signal versus concentration dependence was linear up to 50 ppb, and the detection limit was 0.58 ppb. This modified electrode showed good resistance to the interferences from surface-active compounds and common ions.  相似文献   

8.
Niu X  Zhao H  Lan M 《Analytical sciences》2011,27(12):1237-1241
Integrating the advantages of screen printing technology with the encouraging electroanalytical characteristic of metallic bismuth, we developed an ultrasensitive and disposable screen-printed bismuth electrode (SPBE) modified with multi-walled carbon nanotubes (MWCNTs) for electrochemical stripping measurements. Metallic bismuth powders and MWCNTs were homogeneously mixed with graphite-carbon ink to mass-prepare screen-printed bismuth electrode doped with multi-walled carbon nanotubes (SPBE/MWCNT). The electroanalytical performance of the prepared SPBE/MWCNT was intensively evaluated by measuring trace Hg(II) with square-wave anodic stripping voltammetry (SWASV). The results indicated that the SPBE modified with 2 wt% MWCNTs could offer a more sensitive response to trace Hg(II) than the bare SPBE. The stripping current obtained at SPBE/MWCNT was linear with Hg(II) concentration in the range from 0.2 to 40 μg/L (R(2) = 0.9976), with a detection limit of 0.09 μg/L (S/N = 3) under 180 s accumulation. The proposed "mercury-free" electrode, with extremely simple preparation and ultrahigh sensitivity, holds wide application prospects in both environmental and industrial monitoring.  相似文献   

9.
10.
We have developed a method for the determination of the three catecholamines (CAs) epinephrine (EP), norepinephrine (NE), and dopamine (DA) at sub-nanomolar levels. It is found that the luminescence of the complexes formed between the CAs and Tb3+ ion is strongly enhanced in the presence of colloidal silver nanoparticles (Ag-NPs). The Ag-NPs cause a transfer of the resonance energy to the fluorophores through the interaction of the excited-state fluorophores and surface plasmon electrons in the Ag-NPs. Under the optimized condition, the luminescence intensity of the system is linearly related to the concentration of the CAs. Linearity is observed in the concentration ranges of 2.5–110?nM for EP, 2.8–240?nM for NE, and 2.4–140?nM for DA, with limits of detection as low as 0.25?nM, 0.64?nM and 0.42?nM, respectively. Relative standard deviations were determined at 10?nM concentrations (for n?=?10) and gave values of 0.98%, 1.05% and 0.96% for EP, NE and DA, respectively. Catecholamines were successfully determined in pharmaceutical preparations, and successful recovery experiments are demonstrated for urine and serum samples.
Figure
Schematic presentation of Ag NP-enhanced luminescence of Tb3+-CA complex. (A) Luminescence intensity at 545 nm of Tb3+-EP complex is lower than that of (B) Tb3+-EP-Ag NP system when both are excited at the wavelength of 279 nm.  相似文献   

11.
运用循环伏安法及线性扫描伏安法研究了间苯二胺在金纳米粒子/碳纳米管修饰玻碳电极上的电化学行为,优化并建立了一种直接测定间苯二胺的电化学分析方法。结果表明,与裸玻碳电极相比,金纳米粒子/碳纳米管修饰电极能显著提高间苯二胺的氧化峰电流。在优化条件下,氧化峰电流与间苯二胺浓度在3.0×10-8~1.0×10-6mol/L范围内呈现良好的线性关系,检出限为1.0×10-8mol/L,对1.0×10-7mol/L的间苯二胺溶液平行测定10次的RSD为4.2%。测定了实验室废水中的间苯二胺含量,3次测定结果的平均回收率为99.7%,RSD为2.1%。  相似文献   

12.
We describe a new and promising type of selenium film electrode for anodic stripping voltammetry. This method is based on formation of copper selenide onto an in-situ formed selenium-film carbon electrode, this followed by Osteryoung square-wave anodic stripping voltammetry. Copper(II) is also in-situ electroplated in a test solution containing 0.01 mol L-1 hydrochloric acid, 0.05 mol L?1 potassium chloride and 500 µg L?1 Se(IV) at a deposition potential of ?300 mV. The well-defined anodic peak current observed at about 200 mV is directly proportional to the Cu(II) concentration over the range from 1.0 to 100 µg L?1 under the optimized conditions. The detection limit (three sigma level) is 0.2 µg L?1 Cu(II) at 180 s deposition time. Relatively less interferences are shown from most of metal ions except for antimony(III). The method can be applied to analyses of river water and oyster tissue with good accuracy.  相似文献   

13.
A new type of carbon ceramic electrode modified with bismuth oxide nanoparticles (referred to as Bi-CCE) was fabricated via the sol-gel method. The Bi-CCE was applied to the determination of syringic acid by square wave adsorptive stripping voltammetry. The electrochemical properties of the Bi-CCE and the voltammetric response to syringic acid were investigated by cyclic voltammetry. The effects of the pH value of supporting electrolyte, of accumulation potential, accumulation time, SW mode parameters, and of possible interferents were tested. Under optimized conditions, the oxidation peak current (best measured at 0.8 V vs Ag/AgCl after an accumulation time of 20 s) increases linearly in the 0.4 to 24 μmol·L?1 syringic acid concentration range. Other figures of merit include an LOD of 47 nmol·L?1, a sensitivity of 3.3 μA·μmol?1·L·cm?2, and a relative standard deviation of 4.7% (for n = 5) at 2 μmol·L?1 of syringic acid. The method was successfully applied to the determination of syringic acid in red, white and rose wine as well as water samples.
Graphical abstract Schematic presentation of the preparation of carbon ceramic electrode (CCE) containing Bi2O3 nanoparticles and its application in square wave adsorptive stripping voltammetric (SW AdSV) determination of syringic acid.
  相似文献   

14.
We report on an anodic stripping voltammetric method for the determination of tin using a glassy carbon electrode modified with bismuth and poly(bromophenol blue). After an accumulation time of 60?s at ?1.20?V (vs. SCE), the response of the electrode to tin in 1.0?M HCl is linear in the concentration ranges from 20 nM to 1.0?μM, and from 1.0?μM to 20?μM, with a detection limit of 7.0 nM (at an SNR of 3) and with relative standard deviations in the order of 3.0–3.8%. The method was validated by comparing the results with those obtained by AAS and successfully applied to the determination of tin in canned food.
Figure
Differential pulse stripping voltammetric responses of Sn2+ at Bi/Poly(BPB)/GCE in 1.0 M HCl . Sn2+ concentration (μM): 0.020, 0.10, 0.30, 0.50, 0.70, 1.0, 3.0, 5.0, 7.0, 10.0 and 20.0. Inset: Differential pulse stripping voltammograms of circle portion at low Sn2+ concentration are zoomed in.  相似文献   

15.
In this study, we demonstrated a highly sensitive electrochemical sensor for the simultaneous detection of Pb (II) and Cd (II) in aqueous solution using carbon paste electrode modified with Eichhornia crassipes powder by square wave anodic stripping voltammetry. The effect of modifier composition, pH, preconcentration time, reduction potential and time, and type of supporting electrolyte on the determination of metal ions were investigated. Pre-concentration on the modified surface was performed at open circuit. The modified electrode exhibited well-defined and separate stripping peaks for Pb (II) and Cd (II). Under optimum experimental conditions, a linear range for both metal ions was from 10 to 5000 μg L?1 with the detection limits of 4.9 μg L?1, 2.1 μg L?1 for Cd(II) and Pb (II), respectively. The modified electrode was found to be sensitive and selective when applied to determine trace amounts of Cd (II) and Pb (II) in natural water samples.  相似文献   

16.
The epoxy-impregnated graphite tube electrode bulk modified with 2-mercaptobenzoxazole, employed in a wall-jet configuration, was found to be useful for the continuous flow and flow injection stripping voltammetric determinations of AgI, HgII and BiIII. For continuous flow, detection limits for AgI, HgII and BiIII were 1.8 × 10−10 M, 1.9 × 10−9 M and 9.5 × 10−9 M, respectively (10 min accumulation, S/N = 3). Precisions for 5.00 × 10−9 M AgI, 1.00 × 10−8 M HgII and 1.00 × 10−7 M BiIII were 10.5%, 5.77 % and 7.90% (relative standard deviations, n = 6), respectively. In the case of flow injection stripping, with a 500 μL injection loop, detection limits of 0.59 ng, 2.0 ng and 120 ng were obtained for AgI, HgII and BiIII, respectively (S/N = 3). Selected metal ions, inorganic and organic substances were investigated for interferences. The electrode was tested with a certified sample and then applied to the determinations of the metal ions in a urine and a sea-water sample.  相似文献   

17.
In this article, a study of novel screen-printed electrodes bulk-modified with five potential bismuth precursor compounds (bismuth citrate, bismuth titanate, bismuth oxide, bismuth aluminate and bismuth zirconate) is presented for the determination of Cd(II) and Pb(II) by anodic stripping voltammetry. During the electrolytic deposition step, the precursor was reduced and served as the source of bismuth. Different key parameters were investigated in detail such as the nature of the bismuth precursor compound, the precursor content in the carbon ink, the polarisation range of the sensors, the supporting electrolyte, the stripping waveform, the deposition time, the deposition potential and the long-term stability of the sensors under continuous use. Using bismuth citrate as the precursor, the limit of detection was 0.9 μg L−1 for Pb(II) and 1.1 μg L−1 for Cd(II). The reproducibility on the same sensor (expressed as % relative standard deviation, (n = 8)) was 5.4% for Pb(II) and 7.2% for Cd(II) at the 20 μg L−1 level. Finally, the sensors were applied to the determination of Cd(II) and Pb(II) in water samples.  相似文献   

18.
Various carbon nanomaterials for use in anodic stripping voltammetric analysis of Hg(II), Cu(II), Pb(II) and Cd(II) are screened. Graphene, carbon nanotubes, carbon nanofibers and fullerene (C60), dispersed in chitosan (Chit) aqueous solution, are used to modify a glassy carbon electrode (GCE). The fullerene-chitosan modified GCE (C60-Chit/GCE) displays superior performance in terms of simultaneous determination of the above ions. The electrodes and materials are characterized by electrochemical impedance spectroscopy, cyclic voltammetry, scanning electron microscopy, Raman spectroscopy, X-ray diffraction and X-ray photoelectron spectroscopy. The excellent performance of C60-Chit/GCE is attributed to the good electrical conductivity, large surface area, strong adsorption affinity and unique crystalline structure of C60. Using differential pulse anodic stripping voltammetry, the assay has the following features for Hg(II), Cu(II), Pb(II) and Cd(II), respectively: (a) Peak voltages of +0.14, ?0.11, ?0.58 and???0.82 V (vs SCE); (b) linear ranges extending from 0.01–6.0 μM, 0.05–6.0 μM, 0.005–6.0 μM and 0.5–9.0 μM; and (c), detection limits (3σ method) of 3 nM (0.6 ppb), 14 nM (0.9 ppb), 1 nM (0.2 ppb) and 21 nM (2.4 ppb). Moreover, the modified GCE is well reproducible and suitable for long-term usage. The method was successfully applied to the simultaneous determination of these ions in spiked foodstuff.
Graphical abstract Compared with graphene, carbon nanotubes and carbon nanofibers, an electrode modified with fullerene in chitosan electrode displays superior performance for the simultaneous anodic stripping voltammetric detection of Hg(II), Cu(II), Pb(II) and Cd(II).
  相似文献   

19.
A catalytic adsorptive stripping voltammetric method for the determination of copper(II) on a carbon paste electrode (PCE) in an alizarin red S (ARS)-K2S2O8 system is proposed. In this method, copper(II) is effectively enriched by both the formation and adsorption of a copper(II)-ARS complex on the PCE, and is determined by catalytic stripping voltammetry. The catalytic enhancement of the cathodic stripping current of the Cu(II) in the complex results from a redox cycle consisting of electrochemical reduction of Cu(II) ion in the complex and subsequent chemical oxidation of the Cu(II) reduction product by persulfate, which reduces the contamination of the working electrode from Cu deposition and also improves analytical sensitivity. In Britton-Robinson buffer (pH 4.56±0.1) containing 3.6×10−5 mol L−1 ARS and 1.6×10−3 mol L−1 K2S2O8, with 180 s of accumulation at −0.2 V, the second-order derivative peak current of the catalytic stripping wave was proportional to the copper(II) concentration in the range of 8.0×10−10 to ∼3.0×10−8 mol L−1. The detection limit was 1.6×10−10 mol L−1. The proposed method was evaluated by analyzing copper in water and soil.  相似文献   

20.
Li D  Jia J  Wang J 《Talanta》2010,83(2):332-336
A bismuth-film modified graphite nanofibers-Nafion glassy carbon electrode (BiF/GNFs-NA/GCE) was constructed for the simultaneous determination of trace Cd(II) and Pb(II). The electrochemical properties and applications of the modified electrode were studied. Operational parameters such as deposition potential, deposition time, and bismuth ion concentration were optimized for the purpose of determination of trace metal ions in 0.10 M acetate buffer solution (pH 4.5). Under optimal conditions, based on three times the standard deviation of the baseline, the limits of detection were 0.09 μg L−1 for Cd(II) and 0.02 μg L−1 for Pb(II) with a 10 min preconcentration. In addition, the BiF/GNFs-NA/GCE displayed good reproducibility and selectivity, making it suitable for the simultaneous determination of Cd(II) and Pb(II) in real sample such as river water and human blood samples.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号