A method for the direct determination (without sample pre-digestion) of microelements in fruit juice by inductively coupled plasma optical emission spectrometry has been developed. The method has been optimized by a 23 factorial design, which evaluated the plasma conditions (nebulization gas flow rate, applied power, and sample flow rate). A 1:1 diluted juice sample with 2% HNO3 (Tetra Packed, peach flavor) and spiked with 0.5 mg L− 1 of Al, Ba, Cd, Co, Cr, Cu, Fe, Mn, Ni, Pb, Sb, Sn, and Zn was employed in the optimization. The results of the factorial design were evaluated by exploratory analysis (Hierarchical Cluster Analysis, HCA, and Principal Component Analysis, PCA) to determine the optimum analytical conditions for all elements. Central point condition differentiation (0.75 L min− 1, 1.3 kW, and 1.25 mL min− 1) was observed for both methods, Principal Component Analysis and Hierarchical Cluster Analysis, with higher analytical signal values, suggesting that these are the optimal analytical conditions. F and t-student tests were used to compare the slopes of the calibration curves for aqueous and matrix-matched standards. No significant differences were observed at 95% confidence level. The correlation coefficient was higher than 0.99 for all the elements evaluated. The limits of quantification were: Al 253, Cu 3.6, Fe 84, Mn 0.4, Zn 71, Ni 67, Cd 69, Pb 129, Sn 206, Cr 79, Co 24, and Ba 2.1 µg L− 1. The spiking experiments with fruit juice samples resulted in recoveries between 80 and 120%, except for Co and Sn. Al, Cd, Pb, Sn and Cr could not be quantified in any of the samples investigated. The method was applied to the determination of several elements in fruit juice samples commercialized in Brazil.  相似文献   

2.
A 23 factorial design and a CCD (Central Composite Design) were employed to optimize the operational conditions for determining Al, Ba, Ca, Cd, Cr, Cu, K, Mg, Na, Ni, Pb, Sn and Zn in soft drink samples by inductively coupled plasma optical emission spectrometry (ICP OES). Satisfactory parameters of merit were obtained (Plasma stability, linearity, SBR, BEC, LOD and LOQ). The accuracy was evaluated by means of a recovery study. Thirty five soft drink samples were analyzed. The results obtained were used in an exploratory analysis, in which principal component analysis and cluster analysis were applied in order to differentiate the several soft drink classes. Adequate LOQ values were obtained for all elements (0.34 μg L− 1 for Ca to 88.7 μg L− 1 for Mg) and the recovery study results ranged between 80 and 100%. Cluster analysis revealed four sample classes characterized by flavor and other characteristics, such as being light, diet, low calorie or regular beverages. A model with 4 PCs was obtained by means of a principal component analysis, which explained 99.8% of the total variance.  相似文献   

3.
A procedure for partial digestion of bovine tissue is proposed using polytetrafluoroethylene (PTFE) micro-vessels inside a baby-bottle sterilizer under microwave radiation for multi-element determination by inductively coupled plasma optical emission spectrometry (ICP OES). Samples were directly weighed in laboratory-made polytetrafluoroethylene vessels. Nitric acid and hydrogen peroxide were added to the uncovered vessels, which were positioned inside the baby-bottle sterilizer, containing 500 mL of water. The hydrogen peroxide volume was fixed at 100 µL. The system was placed in a domestic microwave oven and partial digestion was carried out for the determination of Ca, Cu, Fe, Mg, Mn and Zn by inductively coupled plasma optical emission spectrometry. The single-vessel approach was used in the entire procedure, to minimize contamination in trace analysis. Better recoveries and lower residual carbon content (RCC) levels were obtained under the conditions established through a 24-1 fractional factorial design: 650 W microwave power, 7 min digestion time, 50 µL nitric acid and 50 mg sample mass. The digestion efficiency was ascertained according to the residual carbon content determined by inductively coupled plasma optical emission spectrometry. The accuracy of the proposed procedure was checked against two certified reference materials.  相似文献   

4.
Grigoletto T  Oliveira Ed  Gutz IG 《Talanta》2005,67(4):791-797
The new electrolytic dissolution in batch of aluminum alloys samples as grains or turns and the determination of Fe, Cu, Mn, Mg, Cr, Ni, Zn, Pb and Ti by ICP OES was investigated. In on-line electrodissolution procedures described in the literature, samples were restricted to be in the form of solid blocks or plates with one polished flat face. Here, the sample was loaded in the barrel of a modified disposable syringe (the anodic semi-cell) and pressed with a modified plunger fitted with a platinum disk to establish electrical contact with the analyte. This arrangement was introduced in a beaker containing the electrolyte (1 mol L−1 HNO3) and a platinum wire as the cathode. The resulting solution from electrodissolution (0.6 A) was used for the ICP OES determinations. The influence of the aluminum concentration increase on the determination of the elements was evaluated. Electrodissolution of certified reference materials and commercial samples revealed relative errors lower than 10% for the elements Fe, Cu, Mg, Ni, Cr, Zn and Ti (when their content is above 0.1%). Higher inaccuracies (>10%) were observed for Mn and for Fe in B.C.S. 268/1 reference material certified. The proposed method presented a relative standard deviations (R.S.D.) lower or circa 10% to all of the elements (except Pb). In comparison with traditional acid dissolution, the proposed electrodissolution method is relatively fast (about 30 min), it is clean (there is no projection of solution) and simple (heating and fumes exhaust system were not necessaries).  相似文献   

5.
Matoso E  Cadore S 《Talanta》2011,84(2):335-340
A closed vessel method using a microwave oven was developed for the determination of As, B, Ba, Bi, Cd, Cr, Cu, Fe, Hg, Ni, Pb, Se, Sn and Sb by Inductively Coupled Argon Plasma Optical Emission Spectrometry (ICP OES). The method was applied to samples of polyvinyl acetate-based glue in water emulsions. Parameters such as wavelength, nebulization pressure and RF power were optimized and the residual acidity after the digestion process was determined. The addition of internal standards was evaluated and the accuracy of the proposed method was verified with addition and recovery experiments and also with certified reference materials, achieving good results. Using a nebulization flow rate of 0.73 L min−1and a RF power of 1200 W it was possible to obtain adequate values for limit of detection and limit of quantification as well as recovery values in the range of 80-106%, for all the analytes. The analysis of coloured glue samples (white, black, blue, yellow, red and green), widely used by children, showed no contamination by the elements studied.  相似文献   

6.
Herein, we present the development of a procedure for the determination of total sulfur in petroleum-derived products (gasoline, kerosene and diesel fuel) employing inductively coupled plasma optical emission spectrometry (ICP OES). For this procedure, samples were prepared as emulsions that were made using concentrated nitric acid, Triton X-100, sample, and ultra pure water in proportions of 5/10/7/78% (v/v), respectively. Sample volumes were weighed because of the density differences, and oxygen was added to the sheat gas entrance of the ICP OES in order to decrease carbon deposition in the torch and to minimize background effects. A Doehlert design was applied as an experimental matrix to investigate the flow ratios of argon (sheat and plasma gas) and oxygen in relation to the signal-to-background ratio. A comparative study among the slopes of the analytical curves built in aqueous media, surfactant/HNO3, and by spike addition for several sample emulsions indicates that a unique solution of surfactant in acidic media can be employed to perform the external calibration for analysis of the emulsions. The developed procedure allows for the determination of the total sulfur content in petroleum derivatives with a limit of detection (LOD) and limit of quantification (LOQ) of 0.72 and 2.4 μg g− 1, respectively. Precision values, expressed as the relative standard deviations (% RSD, n = 10) for 12 and 400 μg g− 1, were 2.2% and 1.3%, respectively. The proposed procedure was applied toward the determination of total sulfur in samples of gasoline, kerosene, and diesel fuel commercialized in the city of Niterói/RJ, Brazil. The accuracy of the proposed method was evaluated by the determination of the total sulfur in three different standard reference materials (SRM): NIST 2723a (sulfur in diesel fuel oil), NIST 1616b (sulfur in kerosene), and NIST 2298 (sulfur in gasoline). The data indicate that the methodology can be successfully applied to these types of samples. Spiking tests, conducted with the analyzed samples, indicate that recoveries are between 97 and 103%.  相似文献   

7.
Inductively coupled plasma optical emission spectrometers (ICP OES) allow fast simultaneous measurements of several spectral lines for multiple elements. The combination of signal intensities of two or more emission lines for each element may bring such advantages as improvement of the precision, the minimization of systematic errors caused by spectral interferences and matrix effects. In this work, signal intensities for several spectral lines were combined for the determination of Al, Cd, Co, Cr, Mn, Pb, and Zn in water. Afterwards, parameters for evaluation of the calibration model were calculated to select the combination of emission lines leading to the best accuracy (lowest values of PRESS–Predicted error sum of squares and RMSEP–Root means square error of prediction). Limits of detection (LOD) obtained using multiple lines were 7.1, 0.5, 4.4, 0.042, 3.3, 28 and 6.7 µg L− 1 (n = 10) for Al, Cd, Co, Cr, Mn, Pb and Zn, respectively, in the presence of concomitants. On the other hand, the LOD established for the most intense emission line were 16, 0.7, 8.4, 0.074, 23, 26 and 9.6 µg L− 1 (n = 10) for these same elements in the presence of concomitants. The accuracy of the developed procedure was demonstrated using water certified reference material. The use of multiple lines improved the sensitivity making feasible the determination of these analytes according to the target values required for the current environmental legislation for water samples and it was also demonstrated that measurements in multiple lines can also be employed as a tool to verify the accuracy of an analytical procedure in ICP OES.  相似文献   

8.
In this study, microwave-induced combustion (MIC) of extra-heavy crude oil is proposed for further chlorine and sulfur determination by inductively coupled plasma optical emission spectrometry (ICP OES). Combustion was carried out under oxygen pressure (20 bar) in quartz vessels using ammonium nitrate (50 µl of 6 mol l− 1 solution) as ignition aid. Samples were wrapped with polyethylene film and placed on a quartz holder positioned inside the quartz vessels. The need for an additional reflux step after combustion and the type and concentration of absorbing solution (water, 0.02 to 0.9 mmol l− 1 H2O2, 10 to 100 mmol l− 1 (NH4)2CO3 or 0.1 to 14 mol l− 1 HNO3) were studied. The influence of sample mass, O2 pressure and maximum pressure attained during the combustion process were investigated. Recoveries from 92 to 102% were obtained for Cl and S for all absorbing solutions. For comparison, Cl and S determination was also performed by ion chromatography (IC) using 25 mmol l− 1 (NH4)2CO3 as absorbing solution. Using MIC with a reflux step the agreement was better than 95% for certified reference materials of similar composition (crude oil, petroleum coke, coal and residual fuel oil). Microwave-assisted digestion and water extraction in high pressure closed vessels were also evaluated. Using these procedures the maximum recoveries were 30 and 98% for Cl and S, respectively, using microwave-assisted digestion and 70% for Cl and less than 1% for S by water extraction procedure. Limits of detection by ICP OES were 12 and 5 µg g− 1 for Cl and S, respectively, and the corresponding values by IC were 1.2 and 8 µg g− 1. Using MIC it was possible to digest simultaneously up to eight samples resulting in a solution suitable for the determination of both analytes with a single combustion step.  相似文献   

9.
In the present paper a procedure for preconcentration and determination of vanadium and copper in seawater using inductively coupled plasma optical emission spectrometry (ICP OES) is proposed, which is based on solid-phase extraction of vanadium (IV), vanadium (V) and copper (II) ions as 1-(2-pyridylazo)-2-naphthol (PAN) complexes by active carbon. The optimization process was carried out using two-level full factorials and Doehlert matrix designs. Four variables (PAN mass, pH, active carbon mass and shaking time) were regarded as factors in the optimization. Results of the two-level full factorial design 24 with 16 runs for vanadium extraction, based on the variance analysis (ANOVA), demonstrated that the factors pH and active carbon mass, besides the interaction (pH×active carbon mass), are statistically significant. For copper, the ANOVA revealed that the factors PAN mass, pH and active carbon mass and the interactions (PAN mass×pH) and (pH×active carbon mass) are statistically significant. Doehlert designs were applied in order to determine the optimum conditions for extraction. The procedure proposed allowed the determination of vanadium and copper with detection limits (3σ/S) of 73 and 94 ng l−1, respectively. The precision, calculated as relative standard deviation (R.S.D.), was 1.22 and 1.37% for 12.50 μg l−1 of vanadium and copper, respectively. The preconcentration factor was 80. The recovery achieved for determination of vanadium and copper in the presence of several cations demonstrated that this procedure improved the selectivity required for seawater analysis. The procedure was applied to the determination of vanadium and copper in seawater samples collected in Salvador City, Brazil. Results showed good agreement with other data reported in the literature.  相似文献   

10.
An analytical method for separation and pre-concentration of lead in seawater for determination by inductively coupled plasma optical emission spectrometry has been investigated. Lead was retained in the solid phase (0.5 g) composed of co-precipitated naphthalene and alizarin red. The solid phase quantitatively sorbs Pb(II) at pH 8–9, and the metal was eluted using 5.0 ml of 2 mol l−1 nitric acid. The effect of NaCl, KCl, BaCl2, CaCl2, Na2SO4, MgCl2 and Na3PO4 on the sorption of Pb(II) in the solid phase was studied. A set of solutions containing varying amounts of electrolytes (0.5; 1.0; 3.0 and 5.0% m/v) with Pb (50 μg) was prepared and the recommended procedure applied. The Na3PO4 was found to interfere; the other electrolytes did not interfere up to 5% m/v. A pre-concentration factor of 40 was obtained in this analytical procedure. The limit of detection and limit of quantification for Pb(II) were 53 and 176 μg l−1, respectively. Lead was determined in seawater samples collected in Salvador city, Bahia, Brazil. The precision, expressed as R.S.D., was 1.8–4.6%, and the recovery of lead added to seawater samples was 95–97%.  相似文献   

11.
A system for on-line preconcentration and determination of platinum by ultrasonic nebulization (USN) coupled to inductively coupled plasma optical emission spectrometry (ICP-OES) was studied. It is based on the chemical sorption of platinum on a column packed with polyurethane foam loaded with thiocyanate reagent. The optimization step was carried out using two level full factorial design. Three variables (pH, loading flow rate (LFR) and eluent concentration) were regarded as factors in the optimization. Results of the two level factorial design 23 with three replicates of the central point for platinum preconcentration, based on the variance analysis (ANOVA), demonstrated that the factors and their interactions are not statistically significant. The proposed procedure allowed the determination of platinum with a detection limit of 0.28 μg l−1. The precision for 10 replicate determinations at 10.0 μg l−1 Pt level was 3.8% relative standard deviation (R.S.D.), calculated from the peak heights obtained. A total enhancement factor of 100 was obtained with respect to ICP-OES using pneumatic nebulization (10 for USN and 10 for preconcentration). A sampling frequency of 50 samples per hour was obtained. The effect of other ions in concentrations agreeing with water samples was studied. The addition/recovery experiments in the samples analyzed demonstrated the accuracy and applicability of the system developed for platinum determination in spiked water samples.  相似文献   

12.
In this present work a method for the determination of Ca, Fe, Ga, Na, Si and Zn in alumina (Al2O3) by inductively coupled plasma optical emission spectrometry (ICP OES) with axial viewing is presented. Preliminary studies revealed intense aluminum spectral interference over the majority of elements and reaction between aluminum and quartz to form aluminosilicate, reducing drastically the lifetime of the torch. To overcome these problems alumina samples (250 mg) were dissolved with 5 mL HCl + 1.5 mL H2SO4 + 1.5 mL H2O in a microwave oven. After complete dissolution the volume was completed to 20 mL and aluminum was precipitated as Al(OH)3 with NH3 (by bubbling NH3 into the solution up to a pH ~ 8, for 10 min). The use of internal standards (Fe/Be, Ga/Dy, Zn/In and Na/Sc) was essential to obtain precise and accurate results. The reliability of the proposed method was checked by analysis of alumina certified reference material (Alumina Reduction Grade-699, NIST). The found concentrations (0.037% w w−1 CaO, 0.013% w w−1 Fe2O3, 0.012% w w−1 Ga2O3, 0.49% w w−1 Na2O, 0.014% w w−1 SiO2 and 0.013% w w−1 ZnO) presented no statistical differences compared to the certified values at a 95% confidence level.  相似文献   

13.
The acid interferences in inductively coupled plasma atomic emission spectrometry (ICP OES) were studied in a multivariate way, considering the simultaneous presence of four mineral acids (hydrochloric, nitric, sulfuric and perchloric acid) with their concentrations ranging from 5 to 80% (w/w). A low power ICP OES was used, after optimization of operating parameters in order to achieve both plasma robustness and maximum signal to background ratios, favorable for trace element determinations in real samples. In order to investigate the interference mechanism, the combined effects of mineral acids on several parameters (solvent transport rate, analyte transport rate, excitation temperature, electron number density and magnesium ionic to atomic line intensity ratio) were evaluated and discussed. It was found that the combined effects of inorganic acids in ICP OES are, in general terms, more complex than the simple addition of the single effects. The more relevant interactions are between hydrochloric and nitric acids and those with sulfuric acid. Owing to these interactions, the resulting effects on the analytical signals are lower than the expected ones. The extent of any interaction depend on the nature of the interference. For the physical effects which are related with a change in the viscosity of the solution, an attenuation of the acid effect due to the presence of another acid at high concentration was evident. On the contrary, for the interferences related with a change in the plasma excitation conditions, the combined effects are higher than the addition of the single ones.  相似文献   

14.
A new synthesized modified mesoporous silica (MCM-41) using 5-nitro-2-furaldehyde (fural) was applied as an effective sorbent for the solid phase extraction of uranium(VI) and thorium(IV) ions from aqueous solution for the measurement by inductively coupled plasma optical emission spectrometry (ICP OES). The influences of some analytical parameters on the quantitative recoveries of the analyte ions were investigated in batch method. Under optimal conditions, the analyte ions were sorbed by the sorbent at pH 5.5 and then eluted with 1.0 mL of 1.0 mol L−1 HNO3. The preconcentration factor was 100 for a 100 mL sample volume. The limits of detection (LOD) obtained for uranium(VI) and thorium(IV) were 0.3 μg L−1. The maximum sorption capacity of the modified MCM-41 was found to be 47 and 49 mg g−1 for uranium(VI) and thorium(IV), respectively. The sorbent exhibited good stability, reusability, high adsorption capacity and fast rate of equilibrium for sorption/desorption of uranium and thorium ions. The applicability of the synthesized sorbent was examined using CRM and real water samples.  相似文献   

15.
Mercury and lead were determined in an extraction solution applied to compact fluorescent lamps by axial view inductively coupled plasma optical emission spectrometry (ICP OES). The solution contained 50% v/v HNO3 and 10% v/v H2O2. The compact fluorescent lamps were treated by removing the socket and breaking the rest of the lamp inside the solution, followed by placing the mixture in an ultrasonic bath for 1 h. The mixture was filtrated in a coarse paper filter and the resulting extraction slurry was analyzed. The determination of Pb in the slurry required calibration by the analyte addition technique, while for Hg, external calibration was adequate. The quantification limits (10 s, n = 7), for Hg (194.164 nm) and Pb (220.353 nm) were, respectively, 10 and 30 µg per lamp. Analysis of spiked samples demonstrated reasonable accuracy of the method, with recoveries in the range from 99 to 120% for Hg and from 91 to 107% for Pb. Fifteen analyzed samples showed Hg masses per lamp in the range from 1.6 to 27 mg, and six samples were above the limit allowed by the European Community that is 5 mg per compact lamp. The values for Pb were between 0.07 and 0.75 mg per lamp. By filtrating the slurry in a membrane filter, and analyzing the resulting solution, it was found that all Hg was extracted to the liquid phase of the slurry, while a fraction of about 40% m/v of Pb is retained in the solid particles. The lamp cover glass, after extraction of the phosphor layer, was also analyzed for Hg and Pb. The concentration of Hg in the glass is quite low; however, the Pb content is high.  相似文献   

16.
A low-flow air-cooled inductively coupled plasma (ICP) design for optical emission spectrometry (OES) with axial plasma viewing is described and an evaluation of its analytical capabilities in trace element determinations is presented. Main advantage is a total argon consumption of 0.6 L min−1 in contrast to 15 L min−1 using conventional ICP sources.The torch was evaluated in trace element determinations and studied in direct comparison with a conventional torch under the same conditions with the same OES system, ultrasonic nebulization (USN) and single-element optimization. A variety of parameters (x-y-position of the torch, rf power, external air cooling, gas flow rates and USN operation parameters) was optimized to achieve limits of detection (LOD) which are competitive to those of a conventional plasma source.Ionic to atomic line intensity ratios for magnesium were studied at different radio frequency (rf) power conditions and different sample carrier gas flows to characterize the robustness of the excitation source. A linear dynamic range of three to five orders of magnitude was determined under compromise conditions in multi-element mode. The accuracy of the system was investigated by the determination of Co, Cr, Mn, Zn in two certified reference materials (CRM): CRM 075c (Copper with added impurities), and CRM 281 (Trace elements in rye grass). With standard addition values of 2.44 ± 0.04 and 3.19 ± 0.21 μg g−1 for Co and Mn in the CRM 075c and 2.32 ± 0.09, 81.8 ± 0.4, 32.2 ± 3.9 for Cr, Mn and Zn, respectively, were determined in the samples and found to be in good agreement with the reported values; recovery rates in the 98-108% range were obtained. No influence on the analysis by the matrix load in the sample was observed.  相似文献   

17.
The analytical performance of two inductively coupled plasma optical emission spectrometers with axially and radially viewed configurations, equipped with charge coupled device solid-state detectors was evaluated using Ar, Ba, Mg, and Ni as test elements. Both instruments have similar Echelle optical arrangements and radio-frequency generators, differing only in the viewing mode and in the diameter of the central injector tube, i.e. 2.3 for the axially and 1.4 mm for the radially viewed ICP. The figures of merit evaluated were: warm-up time, short- and long-term stabilities, UV and VIS spectral resolution and limit of detection (LOD) for Ni in 0.14 mol l−1 HNO3 and 1000 mg l−1 Cr media, respectively. The influence of residual carbon content on background equivalent concentration (BEC) and sensitivity attained for Al, As, Ca, Cd, Co, Cr, Cu, Fe, Mg, Mn, Se and Zn was also investigated in both viewing modes. The robustness, short- and long-term stabilities, and UV and VIS spectral resolutions were similar for both configurations. For the radially viewed equipment, the warm-up time was at least a factor of 2 shorter than that for the axially viewed configuration. On the other hand, the sensitivity attained for Ni with the axially viewed arrangement was approximately 20 times better than that with the radially viewed. In both viewing modes, and for most of the evaluated elements, the values of BEC and LOD were similar for all studied carbon concentrations (from 10 to 10 000 mg l−1 C) when working with robust plasma conditions. The Mg II/Mg I ratio at an applied power of 1.3 kW and a nebulizer gas flow-rate of 0.90 and 0.70 l min−1 for axially and radially viewed configurations were 10.6 and 13.7, respectively. Quantitative determinations were successfully performed using both systems.  相似文献   

18.
The use of Saccharomyces cerevisiae as a sorbent material to separate Cd(II) and Cd-metallothionein complex (Cd-MT) has been explored. Solid–liquid phase extractions were carried out in batch mode and the main parameters of the process (pH, temperature, time of incubation, amount of biomass and analyte) were evaluated. Under optimized conditions, the yeast quantitatively retain (94 ± 5%) the Cd(II) while 97 ± 2% of the Cd-MT remain in the supernatant. On base of the findings of this study, a simple method is proposed to determine Cd(II) and Cd-MT in cytosols extracted from mouse kidney and crab hepatopancreas. Inductively coupled plasma optical emission spectrometry was used to quantify the analytes in solid and liquid phase. Determination of Cd in the solid phase was carried out by introducing a slurry of the yeast (0.0625 g/10 mL) directly to the inductively coupled plasma optical emission spectrometer. Mixed standards solutions, which also have been submitted to the extraction procedure, were used to quantify the analytes in the samples. Thus, matrix effects due to nebulization of the slurry were overcame. Limits of detection (3σ) for Cd(II) and Cd-MT were 1.5 and 1.2 μg L−1, respectively. Relative standard deviations of signals were 4.2% for measurements in the slurry of solid phase and 2.1% for measurements in the liquid phase. Recoveries of the analytes in cytosol samples were between 76 and 114%. The concentrations of Cd(II) (2.4 ± 0.5 μg L−1) and Cd-MT (3.0 ± 0.5 μg L−1) found by using the proposed approach were close to those found by tangential-flow ultrafiltration technique (2.6 ± 0.7 μg L−1 for Cd(II) and 3.7 ± 1.7 μg L−1 for Cd-MT).  相似文献   

19.
A simple and fast method for the determination of Se in biological samples, including food, by axial view inductively coupled plasma optical emission spectrometry using on-line chemical vapor generation (CVG–ICP OES) is proposed. The concentrations of HCl and NaBH4, used in the chemical vapor generation were optimized by factorial analysis. Six certified materials (non-fat milk powder, lobster hepatopancreas, human hair, whole egg powder, oyster tissue, and lyophilised pig kidney) were treated with 10 mL of aqua regia in a microwave system under reflux for 15 min followed by additional 15 min in an ultrasonic bath. The solutions were transferred to a 100 mL volumetric flask and the final volume was made up with water. The Se was determined directly in these solutions by CVG–ICP OES, using the analytical line at 196.026 nm. Calibration against aqueous standards in 10% v/v aqua regia in the concentration range of 0.5–10.0 µg L 1 Se(IV) was used for the analysis. The quantification limit, considering a 0.5 g sample weight in a final volume of 100 mL 1 was 0.10 µg g 1. The obtained concentration values were in agreement with the total certified concentrations, according to the t-test for a 95% confidence level.  相似文献   

20.
A sensitive and efficient flow-injection (FI) preconcentration and matrix-separation technique coupled to sector field ICP–mass spectrometry (SF-ICP–MS) has been developed and validated for simultaneous determination of ultra-low levels of uranium (U) and thorium (Th) in human urine. The method is based on selective retention of U and Th from a urine matrix, after microwave digestion, on an extraction chromatographic TRU resin, as an alternative to U/TEVA resin, and their subsequent elution with ammonium oxalate. Using a 10 mL sample, the limits of detection achieved for 238U and 232Th were 0.02 and 0.03 ng L–1, respectively. The accuracy of the method was checked by spike-recovery measurements. Levels of U and Th in human urine were found to be in the ranges 1.86–5.50 and 0.176–2.35 ng L–1, respectively, well in agreement with levels considered normal for non-occupationally exposed persons. The precision obtained for five replicate measurements of a urine sample was 2 and 3% for U and Th, respectively. The method also enables on-line measurements of the 235U/238U isotope ratios in urine. Precision of 0.82–1.04% (RSD) was obtained for 235U/238U at low ng L–1 levels, using the FI transient signal approach.  相似文献   