首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 62 毫秒
1.
Since 1980, high-speed counter-current chromatography (HSCCC) has been used for separation and purification of natural and synthetic products in a standard elution mode. In 1991, a novel elution mode called pH-zone refining CCC was introduced from an incidental discovery that an organic acid in the sample solution formed the sharp peak of an acid analyte. The cause of this sharp peak formation was found to be bromoacetic acid present in the sample solution which formed a sharp trailing border to trap the acidic analyte. Further studies on the separation of DNP-amino acids with three spacer acids in the stationary phase revealed that increased sample size resulted in the formation of fused rectangular peaks, each preserving high purity and zone pH with sharp boundaries. The mechanism of this phenomenon was found to be the formation of a sharp trailing border of an acid (retainer) in the column which moves at a lower rate than that of the mobile phase. In order to facilitate the application of the method, a new method was devised using a set of retainer and eluter to form a sharp retainer rear border which moves through the column at a desired rate regardless of the composition of the two-phase solvent system. This was achieved by adding the retainer in the stationary phase and the eluter in the mobile phase at a given molar ratio. Using this new method the hydrodynamics of pH-zone-refining CCC was diagrammatically illustrated by three acidic samples. In this review paper, typical pH-zone-refining CCC separations were presented, including affinity separations with a ligand and a separation of a racemic mixture using a chiral selector in the stationary phase. Major characteristics of pH-zone-refining CCC over conventional HSCCC are as follows: the sample loading capacity is increased over 10 times; fractions are highly concentrated near saturation level; yield is improved by increasing the sample size; minute charged compounds are concentrated and detected at the peak boundaries; and elution peaks are monitored with a pH flow meter for compounds with no chromophore. Since 1994, over 70 research papers on pH-zone-refining CCC have been published with the trends increasing in the recent years.  相似文献   

2.
Alkaloids represent a most widespread group of bioactive natural products. Because of their alkalinity and structural diversity, the fractionation and purification of the alkaloids from herbs can often present a number of practical difficulties using the conventional chromatographic techniques. High-speed counter-current chromatography (HSCCC) is a liquid-liquid partition chromatography with a support-free liquid stationary phase, and is gaining more and more popularity as a viable separation technique for bioactive compounds from natural resources. In the present review, focus is placed on the separation of alkaloids by both conventional HSCCC and pH-zone-refining counter-current chromatography (CCC) techniques from herbs. The review presents the separation of over 120 different alkaloid compounds from more than 30 plant species by the conventional HSCCC and pH-zone-refining CCC. Based on the data from the literature, the proper solvent systems for the separation of alkaloids by the conventional HSCCC and pH-zone-refining CCC are also summarized.  相似文献   

3.
The main components of the color additive D&C Yellow No. 10 (Quinoline Yellow, Color Index No. 47005), 2-(2-quinolinyl)-1H-indene-1,3(2H)-dione-6'-sulfonic acid (6SA) and 2-(2-quinolinyl)-1H-indene-1,3(2H)-dione-8'-sulfonic acid (8SA), were isolated from the dye mixture by pH-zone-refining counter-current chromatography (CCC) in the ion-exchange mode. These positional isomers were separated from a portion of dye using sulfuric acid as the retainer acid and dodecylamine as the ligand (ion exchanger). The added ligand enhanced the partitioning of the hydrophilic components in the organic stationary phase of the two-phase solvent system that consisted of isoamyl alcohol-methyl tert.-butyl ether-acetonitrile-water (3:1:1:5). Thus, separation of 1.8 g of D&C Yellow No. 10 using the above method resulted in 0.6 g of 6SA and 0.18 g of 8SA of over 99% purity. The isolated compounds were characterized by mass spectrometry and proton nuclear magnetic resonance with correlated spectroscopy assignments. The study exemplifies a new field of applications for pH-zone-refining CCC, to the separation of positional isomers of strongly hydrophylic compounds containing sulfonic acid groups.  相似文献   

4.
The effect of solvent system, partition coefficient, retention of stationary phase, column, revolution speed, and flow rate of mobile phase are well known parameters to effect HSCCC (high-speed counter-current chromatography) separations. Temperature effects on chromatographic techniques like HPLC and GC are well studied, but the influence of temperature on CCC solvent systems is hardly investigated. This paper presents the influence of temperature on several key parameters (partition coefficient, settling time, volume ratios) in the hydrophobic HSCCC solvent system hexane:dichloromethane:acetonitrile (30:11:18, v/v/v) used for the isolation of lycopene from tomato paste at 10, 15, 20 and 25 degrees C.  相似文献   

5.
pH-Zone-refining countercurrent chromatography (CCC) is a recently developed new preparative separation method based on conventional CCC. The method uses a retainer base (or acid) in the stationary phase to retain the analyses in the column and an eluent acid (or base) to elute the analyses according to their pKa values and hydrophobicities. It produces a succession of highly concentrated rectangular peaks with minimum overlap similar to those observed in displacement chromatography. pH-zone-refining CCC has important advantages over the conventional CCC including an over 10-fold increase (up to 10 gram or more) in sample loading capacity, high concentration of fractions, and concentration of minor impurities. pH-zone-refining CCC has been successfully applied to the preparative separation of a variety of compounds including both acidic and basic derivatives of amino acid, hydroxyxanthene dyes, peptides, alkaloids, indole auxins, structural, geometrial and optical isomers.  相似文献   

6.
This paper aims to be an aid to those chemists who are interested in utilizing high-speed counter-current chromatography (HSCCC), which is free of irreversible adsorption and offers high resolution comparable to column chromatography. It explains the selection of HSCCC conditions step by step including the selection of two-phase solvent systems, determination of partition coefficient (K) of analytes, preparation of two-phase solvent system and sample solution, selection of elution mode, flow rate, rotation speed, and on-line monitoring of the eluate. The paper covers both standard HSCCC and pH-zone-refining CCC techniques. Technical terms (italic) unfamiliar to the beginner are comprehensively explained in Glossary. Various examples of two-phase solvent systems used in HSCCC are listed in Appendices A and B. The commercial sources of HSCCC and other CCC instruments are described in detail in the study edited by Berthod [A. Berthod (Ed.), Counter-current Chromatography, Elsevier, Amsterdam, 2003].  相似文献   

7.
Owing to no complications caused by solid supports, such as adsorptive sample loss and deactivation, tailing of solute peaks, and contamination, countercurrent chromatography (CCC) has been an area of intense research since the first introduction of CCC in 1970,[1] and various apparatus and broad applications have been advanced[2,3]. For these developments, the type-J synchronous planet centrifuge has received considerable attention, which relies not only on its relatively simple mechanic design, but also on its high partition efficiency and short elution time caused by mixing and settling for the efficient chromatographic separations. In the past, however, almost all of type-J centrifuges rotated slowly were disposed horizontally due to the original design and some experiments that gravis plays an important role at a low rotary speed as similar to type-V rotating multilayer helical tube in unit gravity[4-9]. In fact,we discovered that the upright apparatus holds more retention of stationary phase than the horiziontal aparatus when large standard tubings were used as mutilayer coil column and the aparatus was operated under same contions. We report here a new coil planet centrifuge with four upright cylindrical columns for large scale countercurrent chromatographic preparation. The design principle and apparatus of UCCC is as samilar to type-J multilayer coil planet centrifuge. Four uptight cylindrical column holders are symmetrically arranged around the centrifuge axis as similar to the type-J HSCCC with three horizontal multilayer coils connected in series[8] . A series of experiments indicat that upright CCC has many advantages over the horizontal CCC when using a large-bore tube as multilayer coil column for large scale countercurrent chromatographic separation.Upright CCC provide a versatile countercurrent chromatographic method for large-scale preparation from very crude sample. It has good preparative capacity and flexible suitability to various sample and two-phase system.The present apparatus not only can be operated at a high speed as similar as commonly used HSCCC for the system having short settling time and but also can be run at a low speed for the system having relative long settling time. Because of automatical control and seal-free flow through device, the uptight CCC apparatus may be readily scaled up to industrial preparation.  相似文献   

8.
Yao LF  He HB  Feng YQ  Da SL 《Talanta》2004,64(1):244-251
The chromatographic performance of a new zirconia stationary phase (DPZ) modified with dodecylamine-N,N-dimethylenephosphonic acid (DDPA) is studied by using positional isomers as probes. The DDPA modified zirconia via one phosphonic group has a polar inner-layer and a non-polar outer-layer on its surface. The alkyl chain of outer-layer provides the hydrophobic interaction, while the polar inner-layer that consists of an amine group and a free phosphonic group provided dipolar and ion-exchange/columbic repellent interaction sites. The effects of methanol content, ionic strength and pH of mobile phase on capacity factors of the solutes are studied in detail, and baseline separations of toluidine, nitroaniline, aminophenol, dihydroxybenzene, and nitrophenol isomers were achieved on the new zirconia stationary phase. In addition, retention mechanism of the isomers on the DDPA-modified zirconia stationary phase is also proposed.  相似文献   

9.
高速逆流色谱研究进展   总被引:56,自引:0,他引:56  
综述了近年来高速逆流色谱(HSCCC)在分析、半制备和制备分离天然产物、蛋白质、抗生素、无机物等领域的研究和应用进展,总结了适用于HSCCC的溶剂体系,并展望了HSCCC与质谱联用、pH区带逆流色谱和离子对逆流色谱新技术的应用前景。  相似文献   

10.
Silver-ion high-performance liquid chromatography (Ag+-HPLC) has been shown to be effective in the resolution of most of the isomers of conjugated octadecadienoic acids (18:2), also known as conjugated linoleic acid (CLA). The CLA isomers identified in natural fats from ruminants are a mixture of numerous positional and geometric isomers from 7,9- to 12,14-18:2. Ag+-HPLC separates both geometric (trans,trans < cis/trans < cis,cis) and positional CLA isomers using the mobile phase hexane/acetonitrile (99.9:0.1). The elution volumes for the CLA isomers were not only affected by the concentration of acetonitrile (in the prepared mobile phase) but also with successive runs during the day using a prepared mobile phase batch, due to the partial solubility of acetonitrile in hexane. However, this drift does not affect the relative resolution of the CLA isomers. The addition of diethyl ether to the mobile phase partly stabilizes the solvent mixture. In order to facilitate the interpretation of Ag-+HPLC chromatograms, the relative retention volumes (RRV) were calculated for each CLA isomer. Toluene was added to all the test portions and served as an estimator of dead volume, whereas the elution of the ubiquitous 9c,11t-CLA isomer was chosen as unity (1.00). Expressing the elution of all the CLA isomers as their RRV greatly helped to standardize each CLA isomer, resulting in relatively small coefficients of variation (% CV) for the trans,trans (<1.5%) and cis/trans (<0.5%) CLA isomers. The identification of the CLA isomers was further facilitated by synthesis of authentic CLA isomers. All the geometric CLA fatty acid methyl esters (FAME) from positions 6,8- to 13,15-CLA were commercially available or synthesized by a combination of partial hydrazine reduction of known polyunsaturated fatty acids followed by alkali isomerization, isolation of products, and further iodine-catalyzed geometric isomerization. Based on expressing the elution volume as RRV and the availability of the synthetic CLA isomers, a unique reversal of the elution order of the c/t CLA isomers was found. It is also proposed that the retention times of CLA isomers by gas chromatography (GC) should be expressed as their relative retention times (RRT) relative to methyl gamma-linoleneate. The availability of CLA reference materials and the application of RRV and RRT to Ag+-HPLC and GC separations, respectively, will greatly improve in the identifications of CLA isomers.  相似文献   

11.
Peng A  Li R  Hu J  Chen L  Zhao X  Luo H  Ye H  Yuan Y  Wei Y 《Journal of chromatography. A》2008,1200(2):129-135
In this paper, high-speed counter-current chromatography (HSCCC) instruments with different gravitational forces were applied for the separation of bioactive compounds from Triperygium wilfordii Hook.f. The critical parameters including sample concentration, sample volume and flow rate were first optimized on an analytical Mini-DE HSCCC system, and then scaled up to a preparative TBE 300A HSCCC system. Although this scale-up process was performed using different CCC instruments with different centrifuges and gravitational forces, the same resolutions were obtained and the elution time could be predictable. Five diterpenoid compounds and one unknown compound were separated from Triperygium wilfordii Hook.f. by HSCCC with a two-phase solvent system composed of n-hexane-ethyl acetate-methanol-water (HEMW) (3:2:3:2, v/v/v/v). This one-step flow gradient separation produced triptonide (25 mg), isoneotriptophenolide (77 mg), hypolide (83 mg), unknown compound (1 mg), triptophenolide (42 mg), triptonoterpene methyl ether VI (37 mg) from 320 mg crude extract with purities of 98.2%, 96.6%, 98.1%, 95.3%, 95.1%, and 96.5%, respectively. Their purities and structures were identified by high-performance liquid chromatography, mass spectrometry and NMR. This paper demonstrates that analytical CCC plays an important role in optimizing parameters and scale-up process when analytical CCC and preparative CCC are supplied by different manufacturers with different gravitational forces, and the scale-up process from analytical CCC to preparative CCC is still predictable.  相似文献   

12.
Preparative HSCCC (high-speed counter-current chromatography) could be applied for the isolation of 9'-cis-neoxanthin from a crude carotenoid extract of fresh spinach leaves. The separation was performed on a Pharma-Tech Research Corp. CCC 1000 with a solvent system composed of hexane:ethanol:water at a volume ratio of 5:5:4.5 at a flow rate of 3 mL/min and at 850 rpm, using the lower phase as mobile phase. 9'-cis-neoxanthin with a purity of up to 94% could be obtained with a single HSCCC purification step of the crude carotenoid extract.  相似文献   

13.
The 1,3-alternate 25,27-bis-[p-chlorobenzyloxy]-26,28-bis-[3-propyloxy]-calix[4]arene-bonded silica gel stationary phase was synthesized, structurally characterized, and used as a selector in high performance liquid chromatography. Selectivity studies on that phase used aromatic positional isomers, alkylbenzenes, polynuclear aromatic hydrocarbons, sulfonamides, and non-steroidal anti-inflammatory drugs as analytes. The effects of organic modifier content and pH of the mobile phase on retention and selectivity of selected aromatic positional isomers were studied. Selectivity comparisons of the novel phase vs. 1,3-alternate 25,27-di-[benzyloxy]-26,28-bis-[3-propyloxy]-calix[4]arene phase and commercially available RP-Phenyl phases were performed. The retention mechanism was also discussed. The results indicated that the calixarene stationary phase behaves like a reversed-phase packing; however, other retention mechanisms seem to be involved in the separation process.  相似文献   

14.
To isolate atropine and scopolamine from Daturae metelis Flos, three different elution modes have been applied in pH-zone-refining counter-current chromatography. These separations were performed with a two-phase solvent system composed of ethyl acetate/n-butanol/water (4:1:5 v/v) with 0.50% triethylamine in the organic phase and 0.15% hydrochloric acid in the aqueous phase. As a result, the best separation was obtained by counter-rotation and dual-mode elution procedure. In this new separation mode, the mobile phase and stationary phase were exchanged when the rotation direction was reversed. The two purified alkaloids (purity over 98% as determined by HPLC) were identified by ESI-MS, (1)H-NMR and (13)C-NMR.  相似文献   

15.
We developed a n-hexane/surfactant-containing water solvent system in counter-current chromatography (CCC) in order to separate hydrophobic compounds. By using the upper phase as the mobile phase, we have separated steroid samples. Retention times of steroids progesterone and delta4-androstene-3,17-dione increased slightly by increasing the concentration below the critical micellar concentration (CMC) of surfactant sodium 1-heptanesulfonate. However, the retention times increased drastically while the SHS concentrations were above the CMC. The partition of these two steroids in the two phases was significantly dependent on the interaction with micelles. Aromatic hydrocarbons were not retained by the lower phase no matter what the surfactant concentrations were. Their hydrophobic interaction with n-hexane greatly exceeded that with the micellar solution. The retention times of esters, however, were only slightly affected by the surfactant addition even above the CMC. The weaker interaction between esters and the micellar solution was probably due to their higher polarity. The micellar solvent systems provide an alternative way for hydrophobic sample separations in CCC, but the performance is limited.  相似文献   

16.
Counter-current chromatography (CCC) is a form of liquid–liquid partition chromatography. It requires two immiscible solvent phases; the stationary phase is retained in the separation column, generally by centrifugal force, while the mobile phase is eluted. We recently replaced the mobile phase with supercritical fluid carbon dioxide (SF CO2). Since the solvent strength of SF CO2 can be varied by changing the temperature and pressure of the system, separation adjustments are thus more versatile. We investigated the pressure and temperature effects on resolution using water and low-carbon alcohol mixtures as the stationary phases. It was demonstrated that these special properties of SF CO2 were indeed beneficial to the optimization of separations. In addition, the phase retention ratio was examined in terms of separation resolution. The results appeared very similar to those obtained from conventional traditional CCC. This study should be helpful for the future development of SF applications in CCC.  相似文献   

17.
Countercurrent chromatography (CCC) is a separation technique which may be described as a combination of a great number of liquid–liquid distributions of analytes in a two-phase solvent system with liquid chromatography (LC) features. Even optimized CCC separations currently provide a lower number of theoretical plates when compared to LC. For this reason, instrumental advancements are indispensable to, at least partly, overcome this drawback. Recently, we found that improvement of the classic CCC coil, that is using a long hollow tubing, may be achieved by the introduction of tubing crimpings which increase the stationary phase retention. In this study, we systematically investigated the effects of three geometrical parameters (crimping depth, distance between two crimpings as well as partial or complete crimping of the tubing) on the stationary phase retention by a factorial design of experiments approach. Separation efficiency tests were performed with two groups of analytes: fatty acid methyl esters (FAME) in the n-hexane/acetonitrile (HAcn) and alkyl p-hydroxybenzoates in the n-hexane/tert-butylmethylether/methanol/water solvent system. The most narrow crimping distance and the deepest crimping of the tubing were the best configurations in the examined flow rate range.  相似文献   

18.
This work involves the preparative separation of some isomeric dicarboxylic acids using pH-zone-refining counter-current chromatography (CCC), a relatively new preparative technique for the separation of ionizable compounds. The paper concentrates especially on the separation of a synthetic mixture of closely related cis and trans pairs of 1-methyl- and 1,3-dimethyl-1,3-cyclohexanedicarboxylic acids. The elution sequence of the isomers is discussed in terms of their relative acidities (pK(a) values) in solution and gas phase, hydrophobicities, and steric configuration. Two possible explanations are suggested for the mechanism of separation. They both involve the amount of retainer acid used, as it affects the separation and plays a role in the chemohydrodynamic equilibrium of the dicarboxylic acids in the column.  相似文献   

19.
Chlorogenic acid, an ester formed between caffeic acid and quinic acid, is a major phenolic compound in the traditional Chinese medicinal herb Flos Lonicerae. The separation and purification of chlorogenic acid from the crude extract of Flos Lonicerae was achieved by high-speed counter-current chromatography (HSCCC). A high acid, highly polar two-phase solvent system containing n-butanol-acetic acid-water (4:1:5) was run on a preparative scale. The upper phase was used as the mobile phase in the head to tail elution mode. A 300-mg quantity of the crude extract containing 5.97% chlorogenic acid was loaded on a 342-ml HSCCC column. Double separations were performed with the same solvent system yielding 16.9 mg chlorogenic acid at 94.8% purity with approximately 90% recovery.  相似文献   

20.
The amphiphilic polymer‐grafted silica was newly prepared as a stationary phase in high‐performance liquid chromatography. Poly(4‐vinylpyridine) with a trimethoxysilyl group at one end was grafted onto porous silica particles and the pyridyl side chains were quaternized with 1‐bromooctadecane. The obtained poly(octadecylpyridinium)‐grafted silica was characterized by elemental analysis, diffuse reflectance infrared Fourier transform spectroscopy and Brunauer–Emmett–Teller analysis. The degree of quaternization of the pyridyl groups on the obtained stationary phase was estimated to be 70%. The selective retention behaviors of polycyclic aromatic hydrocarbons including some positional isomers were investigated using poly(octadecylpyridinium)‐grafted silica as an amphiphilic polymer stationary phase in high‐performance liquid chromatography and results were compared with commercially available polymeric octadecylated silica and phenyl‐bonded silica columns. The results indicate that the selectivity toward polycyclic aromatic hydrocarbons exhibited by the amphiphilic polymer stationary phase is higher than the corresponding selectivity exhibited by a conventional phenyl‐bonded silica column. However, compared with the polymeric octadecylated silica phase, the new stationary phase presents similar retention behavior for polycyclic aromatic hydrocarbons but different retention behavior particularly for positional isomers of disubstituted benzenes as the aggregation structure of amphiphilic polymers on the surface of silica substrate has been altered during mobile phase variation.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号